Tender For Repair/ Maintenance Of Cooling Appliances Like Split Acs, Water Coolers, Deep Freezers Etc At installation Dronacharya Under Ge Fort Kochi
Tender Value
14 Lakhs
Estimated cost
Bid Submission
11 Dec 2026
19 days left
EMD
28000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance Of Cooling Appliances Like Split Acs, Water Coolers, Deep Freezers Etc At installation Dronacharya Under Ge Fort Kochi
BOQ
| Sl. No. | Item Description |
| 1 | Material and labour for attending day to day complaints pertains to various capacity of cooling appliances, equipments as and when site requirement and complaints arises. Arrange Highly skilled Mechanic -01No with helper -01No to repair all type of cooling appliances, equipments like all type of ACs, all type of Refrigerators, Deep freezers, Water coolers etc.. It includes repairs, maintenance, timely replacement of spare parts, testing, smooth functioning of equipments. Also provide helper and necessary tools and plants for checking the equipments at existing location, find out the faults of equipments, rectification of minor problems, electric loose connections, compressor control panel resetting with electrical components like replacement of lugs/pin, MCB resetting, electrical wiring connections gas top up (gas shall be measured and paid separately under relevant item), to make the Cooling Appliances, equipments functional complete in all respect all as specified and as directed by the Engineer -In Charge. Notes: 1. Complaints/service schedule list shall be collected from concerned JE/Engineer-In Charge and report back on daily basis. 2. The Serial item Nos of BOQ 02 to 18 of BOQ are outside the scope of this item. 3. A penalty of Rs. 500/- per day will be levied in case breakdown of equipment more than 3 working hours from the time of complaint registration due to non-attending. 4.The Item shall be measured and paid only for detecting the faults and for rectifications works. If any spare replacement needed in the work, the same shall be measured and paid under relevant item. |
| 2 | Supply and fix factory built hermetically sealed compressor unit suitable for 1.5 Ton, single phase,230 V,50Hz capacity split / window type AC, testing the leak of compressor by charging Dry Nitrogen gas, evacuating the system and charging R-22/ 304a / 407a / 134 Refrigerant gas including taking out old unserviceable compressor with connected old material from the split type ACs / window ACs complete all as specified and as directed |
| 3 | `-Ditto- all as per item No- 02 here in above but 2.0 TR |
| 4 | `-Ditto- all as per item No- 02 here in above 2.5 TR up to 3.0 TR |
| 5 | Material and labour for Leak testing of Window / Split type ACs, Water cooler, Refrigerator, Deep freezer etc. including filling of nitrogen gas for pressure testing, finding leaks, Vacuuming the system, necessary brazing work, charging with refrigerant gas (R-22 / R 304 a /R 407a /R 134) of required quantity, testing for proper functioning complete all as specified as directed |
| 6 | Material and labour for onsite servicing 1.5 / 2.0 / 2.5/ 3.0 Ton capacity split / window type AC of any description by cleaning air filter, cooling coil / condenser coil and outer cabinet with pressurised water and detergent solution, applying new insulation to turn/damaged insulation complete all as specified and as directed. |
| 7 | Supply and fixing in repairs of condenser fan motor with capacitor and mounting materials, single phase, 230 Volts, 50 Hz suitable for 1.0/1.5/2.5 /3.0 Ton capacity split type AC including taking out old unserviceable blower motor complete all as specified and as directed. |
| 8 | Supply and fixing in repairs of thermostat cut off switch suitable for 1.5 / 2.0 / 2.5/3.0 Ton capacity split / window type AC complete all as specified and as directed. |
| 9 | Supply and fixing in repairs of overload protective relay suitable for 1.5/2.0/2.5/3.0 Ton capacity window type AC complete all as specified and as directed. |
| 10 | Supply and fixing in repairs of starting relay suitable for 1.5 /2.0/2.5/3.0 Ton capacity window type AC complete all as specified and as directed. |
| 11 | Supply and fixing in repairs of copper, aluminium mixed alloy condenser suitable for up to 1.5 Ton capacity split / window type AC complete all as specified and as directed. |
| 12 | Supply and fixing in repairs of copper, aluminium mixed alloy condenser suitable for 2.0 Ton capacity split type AC complete all as specified and as directed. |
| 13 | Supply and fixing in repairs of copper, aluminium mixed alloy condenser suitable for 2.5 up to 3.0 Ton capacity split type AC complete all as specified and as directed. |
| 14 | Supply and fixing in repairs of 30/ 36 mfd running capacitor suitable for 1.5 / 2.0 / 2.5 Ton capacity split / window type AC complete all as specified and as directed. |
| 15 | Supply and fixing in repairs of PVC fan blade suitable for 1.5/2.0/2.5 Ton capacity split / window type AC complete all as specified. |
| 16 | Supply and fixing in repairs of Prime Control Remote Board and temperature digital display sensor suitable for split type/Window AC of any capacity, make or model all as per site requirement complete all as specified and as directed. |
| 17 | Supply and fixing in repairs of liquid strainer suitable for 1.5 / 2.0 / 2.5 Ton capacity split type AC complete all as specified and as directed. |
| 18 | Supply and fixing in repairs of capillary tube for 1.5 / 2.0 / 2.5 Ton capacity split type AC complete all as specified and as directed. |
| 19 | Supply and fixing in repairs of factory built hermetically sealed compressor unit suitable for 285 / 310 / 340 Ltrs capacity Refrigerator, Deep freezer testing the leak of compressor by charging dry Nitrogen gas, evacuating the system and charging R-134 / R-600 Refrigerant gas including taking out old unserviceable compressor from the Refrigerator complete all as specified and as directed |
| 20 | Supply and fixing in repairs of thermostatic switch suitable for 175 / 205 / 285 / 290 / 310 / 340 Ltrs capacity Refrigerator complete all as specified and as directed. |
| 21 | Supply and fixing in repairs of starting relay suitable for 175 / 205 / 285 / 290 / 310 / 340 Ltrs capacity Refrigerator complete all as specified and as directed. |
| 22 | Supply and fixing in repairs of door switch suitable for 175 / 205 / 285 / 290 / 310 / 340 Ltrs capacity Refrigerator complete all as specified and as directed. |
| 23 | Supply and fixing in repairs of drier filter of size 1/4\\" x 1/4” flare connection suitable for 175 / 205 / 285 / 290 / 310 / 340 Ltrs capacity Refrigerator complete all as specified and as directed. |
| 24 | Supply and fixing in repairs of overload relay suitable for 175 / 205 / 285 / 290 / 310 / 340 Ltrs capacity Refrigerator complete all as specified and as directed. |
| 25 | Supply and fixing in repairs of electronic fan motor, single phase, 230 Volts, 50 Hz suitable for 425 Ltrs capacity Deep freezer complete all as specified and as directed. |
| 26 | Supply and fixing in repairs of thermostatic switch suitable for 425 Ltrs capacity Deep freezer complete all as specified and as directed. |
| 27 | Supply and fixing in repairs of factory built hermetically sealed compressor unit suitable for 40 / 60 / 80 Ltrs capacity water cooler, testing the leak of compressor by charging dry Nitrogen gas, evacuating the system and charging R-134/R-22 Refrigerant gas including taking out old unserviceable compressor from the water cooler complete all as specified and directed |
| 28 | Supply and fixing in repairs of starting relay assembly suitable for 40 / 60 / 80 / 120 Ltrs capacity water cooler complete all as specified and as directed. |
| 29 | Supply and fixing in repairs of running capacitor suitable for 40 / 60 / 80 / 120 Ltrs capacity water cooler complete all as specified and as directed. |
| 30 | Supply and fixing in repairs of overload relay suitable for 40 / 60 / 80 / 120 Ltrs capacity water cooler complete all as specified and as directed. |
| 31 | Supply and fixing in repairs of thermostatic switch suitable for 40 / 60 / 80/ 120 Ltrs capacity water cooler complete all as specified and as directed. |
| 32 | Supply and fixing in repairs of 15mm dia brass chromium plated push cock / lifting cock suitable for 40 / 60 / 80 / 120 Ltrs capacity water cooler complete all as specified and as directed |
| 33 | Supply and fixing in repair 15mm dia PVC high pressure release valve complete all as specified and as directed. |
| 34 | Supply and fixing in repairs of condenser fan motor, single phase, 50 Hz, 230 Volts suitable for 40 / 60 / 80 / 120 Ltrs capacity water cooler complete all as specified as directed. |
| 35 | Supply and fixing in repairs of 15mm dia, 450mm long, PVC connection with brass check nuts, complete all as specified and as directed. |
| 36 | Supply and fixing in repairs of liquid strainer suitable for any capacity of water cooler complete all as specified and as directed. |
| 37 | Supply and fixing in repairs of capillary tube suitable for any capacity water cooler complete all as specified and as directed. |
| 38 | Material and labour for maintenance of water purifier cum water cooler, hot and cold, electrically operated of make Best Water Doctor / Cross Field by servicing parts, attending break down, renewal of parts including checking the equipment by the Service Engineer of OEM complete all as specified and as directed. Notes :- (i) Renewal of spare parts will be measured and paid as supply only under relevant items. (ii) The cost of labour and consumables required for renewal of parts shall deem to be included in the unit rate quoted by the contractor. (iii) The Serial item Nos of BOQ 39 to 50 of BOQ shall be outside the scope of this item. (iv) Complaints/service schedule list shall be collected from concerned JE/Engineer-In Charge and report back on daily basis. |
| 39 | Supply only D2 Main PCB suitable for water purifier cum watercooler. Make: - Best Water Doctor and m/s Cross Field complete all as specified and as directed |
| 40 | Supply only compressor suitable for water purifier capacity up to 10 ltr complete all as specified. |
| 41 | Supply only solenoid valve suitable for water purifier complete all as specified and as directed |
| 42 | Supply only two-way valve suitable for water purifier complete all as specified and as directed |
| 43 | Supply only PF candle (Industrial) suitable for water purifier complete all as specified and as directed |
| 44 | Supply only PF Bowl & cap suitable for water purifier complete all as specified and as directed |
| 45 | Supply only compressor relays suitable for water purifier complete all as specified and as directed |
| 46 | Supply only compressor fan motor suitable for water purifier complete all as specified and as directed |
| 47 | Supply only thermostat (cooler) suitable for water purifier complete all as specified and as directed |
| 48 | Supply only thermostat (heater) suitable for water purifier complete all as specified and as directed. |
| 49 | Supply only heating element suitable for water purifier complete all as specified and as directed. |
| 50 | Supply and fixing in repairs for plug top suitable for industrial socket/normal 16 Amp socket complete all as specified and as directed. Make : Legrand / Standard / Havells/ Anchor |
| 51 | Supply and fix in repairs voltage stabilizer 5 KVA by rewinding the main stabilizing unit and replacing PCB, sensing unit, power relay, connector piece and testing on completion all as specified and as directed. |
| 52 | `-Ditto- all as per item No 51 here in above but of up to 4KVA |
| 53 | Supply and fixing in repairs of copper pipe OD of any size including connecting to split type AC and applying insulation complete all as specified and as directed. |
| 54 | Supply and fixing in repairs of PVC drain pipe one-metre long 32mm dia heavy duty with two Nos of galvanized adjustable clamps complete all as specified and as directed. |
| 55 | Supply and fixing in repairs of PVC float valve suitable for 15 mm dia assembly and comprising valve assembly AL rod, PVC ball for water coolers complete all as specified and as directed. Make :- Paryag/ Polytuff or equivalent |
| 56 | Supply and fixing in repairs of overload protector relay 2613 including taking down existing complete all as specified and as directed. Make: Techemshah/ Hitachi or equivalent. |
| 57 | Opening of Refrigerators freezer of capacity 265/285/310 ltrs refixing the same after flushing out and removal of blockage brazing, renewal of liquid line filter and recharging the refrigerator with freon-12 refrigerant to obtain the desired cooling (Temperature) complete including testing all as specified and as directed. |
| 58 | Supply and fixing in repairs of Prime Control Remote Board and temperature digital display sensor suitable for 3 phase Tower AC of any capacity, make or model all as per site requirement complete all specified and as directed. |
| 59 | Supply and filling of Refrigerant Gas-R-22.in ACs/Water coolers/Refrigerators of any model and capacity including leakage testing complete all specified and as directed. |
| 60 | Supply and filling of Refrigerant Gas-410a (Penta & Di Fluoroethane)/304 a /407a /134 ACs/Water coolers/Refrigerators of any model and capacity including leakage testing complete all specified and as directed. |
| 61 | Supply and filling of Refrigerant Gas R- 32, ACs/Water coolers/ Refrigerators of any model and capacity including leakage testing complete all specified and as directed. |
| 62 | Material and Labour for factory made Sealed compressor unit suitable for 2.5/3 TR capacity 3 phase Tower AC including first filling of refrigerant gas, compressor oil etc. testing and commissioning, including taking down of old unserviceable one complete all as specified and as directed. |
| 63 | Material and Labour for servicing of condenser coil of Tower split AC 2.5/3TR capacity, Cleaning / Pressure washing of choked condenser fins, tubes etc, with water soluble material including leak testing complete all as specified and as directed. |
| 64 | Supply and fixing in repairs of Fan motor suitable for outdoor unit of 3 phase tower AC of any capacity make or model all as specified and as directed. |
| 65 | Writing letters or figures for permanent marking of MES No with anti-corrosive enamel paint not exceeding 03 cm in height as numbers obtained from Engineer-in-charge in window AC/ Split ACs inner and outer unit and water cooler /refrigerator etc with thick approved colour paint complete all specified and as directed. |
| 66 | Supply and fixing in repairs of indoor unit and outdoor unit kit of 1.5 TR split type ACs of any make by dismantling the old indoor unit and outdoor unit connecting up with existing outdoor unit and indoor unit including complete indoor unit items like blower fan, PCB/ Remote controls etc. and excluding out door unit components like compressor, condenser fan motor and condenser unit, copper pipe complete set and necessary brazing as per site requirement etc complete all as specified and as directed. |
| 67 | Supply and fixing in repairs of indoor unit and outdoor unit kit of 2.0 TR split type ACs of any make by dismantling the old indoor unit and outdoor unit connecting up with existing outdoor unit and indoor unit including complete indoor unit items like blower fan , PCB, / Remote controls etc. and excluding out door unit components like compressor, condenser fan motor and condenser unit, copper pipe complete set and necessary brazing as per site requirement etc. complete all as specified and as directed. |
| 68 | Material and Labour for disconnection of the power supply of split ACs and dismantling, taking down split ACs, any make /mode/type of capacity 1.5/ 2.0TR from existing location including indoor units/ outdoor units along with its copper pipes, connecting cables, clamps/ stands, water drain pipes etc including making good the surfaces to match with existing finishes in all respects and re-fixing at new location as directed with all accessories such as clamps, pipes, stand for outdoor unit including top up of refrigerant gas if required and making satisfactory working of AC unit in all respect complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysDec 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 26 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender