Tender for Repair And Maintenance Of Summer Appliances In Domestic & Tech Area At Af Stn Halwara Under Ge (Af) Halwara
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully window / Split AC unit of any size, any type, any capacity from the fitting/mountings, disconnecting power cables, drain pipes & accessories etc for repairs and refixing the AC unit and connecting up complete after carrying out necessary repairs to the entire satisfaction of the engineer in charge including transportation, complete all as specified and directed. Note : Spare parts will be measured and paid separately under relevent items. |
| 2 | M&L for servicing and cleaning of window / split type AC unit of any size, any capacity by removing dust with suitable method, cleaning of air filters, tightening of loose wire, nuts, bolts, washers, servicing of condenser motor/blower, by oiling, greasing, required welding/bracing, replacement of worn out rubber bushes of condensor motor, setting of grill alignment & knobs, Checking for any leakages, provision of thermocoal for air tightness, testing etc, complete all as specified and directed. |
| 3 | M&L for removing the unserviceable blower motor double Shaft, suitable for window type AC 1.0/1.5/2.0 Ton and M&L for rewinding of blower motor, single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush, cleaning, greasing and refixing of motor, connecting up all including testing and refixing, complete all as specified and directed. |
| 4 | M&L for removing the unserviceable Out door fan motor suitable for Split type AC 1.5/2.0/3.0 Ton out door unit and rewinding of out door motor, single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush, cleaning, greasing and refixing of motor, connecting up all including testing and refixing, complete all as specified and directed. |
| 5 | M&L for removing the unserviceable indoor motor suitable for Split type AC 1.5/2.0/3.0 Ton unit and rewinding of indoor door motor, single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush, cleaning, greasing and refixing of motor, connecting up all including testing and refixing, complete all as specified and directed. |
| 6 | S&F in replacement blower motor double Shaft, suitable for window type AC 1.0/ 1.5/2.0 Ton single ended or double ended shaft as per OEM make & size, complete all as specified and directed. |
| 7 | S&F in replacement Out door fan motor suitable for Split type AC 1.5/2.0/3.0 Ton out door unit single ended as per OEM make and size, complete all as specified and directed. |
| 8 | S&F in replacement indoor motor suitable for Split type AC 1.5/2.0/3.0 Ton unit single ended as per OEM make and size, complete all as specified and directed. |
| 9 | Removing the unserviceable rotary compressor from window type AC and supply and fix new compressor suitable for 1.5 Ton window type AC all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube and strainer/filter as per existing size and make, complete all as specified and directed. |
| 10 | Removing the unserviceable rotary compressor from window type AC and supply and fix new compressor suitable for 2.0 Ton window/split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube and strainer/filter as per existing size and make, complete all as specified and directed. |
| 11 | Removing the unserviceable rotary compressor from Split type AC and supply and fix new compressor suitable for 1.5 Ton split type AC all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube and strainer/filter as per existing size and make, complete all as specified and directed. |
| 12 | Removing the unserviceable rotary compressor from Split type AC and supply and fix new compressor suitable for 2.0 Ton split type AC all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube and strainer/filter as per existing size and make, complete all as specified and directed. |
| 13 | Removing theunserviceable compressor from Split type AC and supply and fix new Inverter type compressor suitable for 1.5 Ton split type AC all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube and strainer/filter as per existing size and make, complete all as specified and directed. |
| 14 | Removing the unserviceable compressor from Split type AC and supply and fix new Inverter type compressor suitable for 1.5 Ton split type AC all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube and strainer/filter as per existing size and make, complete all as specified and directed. |
| 15 | Removing the unserviceable compressor from Split type AC and supply and fix new Inverter type compressor suitable for 2.0 Ton split type AC all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube and strainer/filter as per existing size and make, complete all as specified and directed. |
| 16 | Removing the unserviceable compressor from window type AC and supply and fix new Inverter type compressor suitable for 1.5 Ton window AC all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube as per existing size and make, complete all as specified and directed. |
| 17 | Removing the unserviceable compressor from window type AC and supply and fix new Inverter type compressor suitable for 2.0 Ton window AC all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capillary tube as per existing size and make, complete all as specified and directed. |
| 18 | M&L for shifting of air conditoner of any type / any capacity, any make with necessary addition / alteration to window / wall, complete all as specified and directed. |
| 19 | Dismantling of cooling (evaporator) coil for repairs of 1.5/2.0 Ton capacity window / split type AC made up of copper tubing and copper/aluminium cooling fins including brazing, welding etc replacement of copper/ aluminum tubing/fins as per site requirement, refixing in original position and testing etc, complete all as specified and directed. |
| 20 | Dismantling of condenser coil for repairs of 1.5/2.0 Ton capacity window / split type AC made up of copper tubing and copper / aluminium cooling fins including brazing, welding etc replacement of copper/aluminum tubing/fins as per site requirement, refixing in original position and testing etc, complete all as specified and directed. |
| 21 | S&F in replacement of cooling coil for window type AC 1.5 Ton capacity including brazing, welding fixing etc, complete all as specified and directed. |
| 22 | S&F in replacement of cooling coil for window type AC 2.0 Ton capacity including brazing, welding fixing etc, complete all as specified and directed. |
| 23 | S&F in replacement of cooling coil for split type AC 1.5Ton capacity including brazing, welding fixing etc, complete all as specified and directed. |
| 24 | S&F in replacement of cooling coil for split type AC 2.0 Ton capacity including brazing, welding fixing etc, complete all as specified and directed. |
| 25 | S&F in replacement of condenser coil for window type AC 1.5 Ton capacity including brazing, welding fixing etc, complete all as specified and directed. |
| 26 | S&F in replacement of condenser coil for window type AC 2.0 Ton capacity including brazing, welding fixing etc, complete all as specified and directed. |
| 27 | S&F in replacement of condenser coil for split type AC 1.5 Ton capacity including brazing, welding fixing etc, complete all as specified and directed. |
| 28 | S&F in replacement of condenser coil for split type AC 2.0 Ton capacity including brazing, welding fixing etc, complete all as specified and directed. |
| 29 | S&F in replacement of PVC drain pipe for split AC as per existing size, complete all as specified and directed. |
| 30 | S&F in replacement of starting capacitor of 50+6 Mfd 50 Hz, suitable for 1.5/2 Ton A/C, complete all as specified and directed. |
| 31 | S&F in replacement of starting capacitor of 45+6 Mfd 50 Hz , suitable for 1.5/2 Ton A/C, complete all as specified and directed. |
| 32 | S&F in replacement of capacitor 2.5 to 10 Mfd ,50Hz as per existing suitable for condenser motor of 1.5/2 Ton A/C capacity, complete all as specified and directed. |
| 33 | S&F in replacement over load protector relay suitable for 1.5 /2 Ton A/C, complete all as specified and directed. |
| 34 | S&F in replacement starting relay box type suitable for 1.5/2 Ton capacity, complete all as specified and directed. |
| 35 | S&F in replacement of air filter pad of nylon cleanable/washable type of existing thickness for Split type A/C 1.5/2.0 ton Capacity as per existing, complete all as specified and directed. |
| 36 | S&F in replacement of front grill of window type A/C of capacity 1.5 / 2 Ton as per existing one, complete all as specified and directed. |
| 37 | Material and Labour for replacement of Motor for fan Blade suitable for Window Type AC 1.5/2 TR complete as per existing, complete all as specified and directed. |
| 38 | Supply and fixing in replacement Blower for indoor split AC As per existing, complete all as specified and directed. |
| 39 | Disconnecting of PCB for repair of window type AC 1.5/2.0 TR including refixing in original position and testing etc, complete all as specified and directed. |
| 40 | Disconnecting of PCB for repair of split type AC 1.5/2.0 TR including refixing in original position and testing etc, complete all as specified and directed. |
| 41 | S&F in replacement of PCB with remote for window type AC 1.5/2.0 TR, complete all as specified and directed. |
| 42 | S&F in replacement of PCB with remote for split type AC 1.5/2.0 TR, complete all as specified and directed. |
| 43 | S&F in replacement of indoor unit for split type AC 1.5 Ton capacity including brazing, welding fixing etc, complete all as specified and directed. |
| 44 | S&F in replacement of indoor unit for split type AC 2.0 Ton capacity including brazing, welding fixing etc, complete all as specified and directed. |
| 45 | Material and labour for replacement of copper discharge tube of size 3/8\\" , duly nylon insulated, complete all as specified and directed.Note :- Only weight of copper tube shall be measured and paid. |
| 46 | Material and labour for replacement of copper suction tube of size 5/8\\" duly nylon insulated, complete all as specified and directed.Note :- Only weight of copper tube shall be measured and paid. |
| 47 | Material and labour for replacement of copper discharge tube of size 1/4\\" , duly nylon insulated, complete all as specified and directed.Note :- Only weight of copper tube shall be measured and paid. |
| 48 | Material and labour for replacement of copper discharge tube of size 1/2\\" , duly nylon insulated, complete all as specified and directed.Note :- Only weight of copper tube shall be measured and paid. |
| 49 | S&F Insulation material for any size, complete all as specified and directed. |
| 50 | Material and labour in replacement blade of condensor fan motor (as per sample) for window type AC cap 1.5/2.0 Ton, complete all as specified and directed. |
| 51 | Material and labour in replacement outdoor blade of condensor fan motor (as per sample) for split type AC cap 1.5/2.0 Ton, complete all as specified and directed. |
| 52 | Tracing out leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including bracing, welding, replacement of filter strainer charging line and filling of gas charging as prescribed by manufacturer, leak testing & commissioning of window type A/C Split type A/C of any type, any capacity, any make, complete all as specified and directed. |
| 53 | Supply and fix in replacement of pencil type driers made in brass heavy duty suitable for window / split type AC, complete all as specified and directed. |
| 54 | Supply and fix in replacement of pin Valve /gas charging Valvesuitable for window/split type AC, complete all as specified and directed. |
| 55 | Supply & fixing single pole & neutral enclosure with two pin and earth plug and socket including MCB SP 32A, complete all as specified and directed. |
| 56 | Supply and fix in replacement 4 KVA wall mounting type electronic voltage stabilizer for automatic operation, single phase, naturally air cooled indoor type, complete all as specified and directed. |
| 57 | Supply and fix in replacement 5 KVA wall mounting type electronic voltage stabilizer for automatic operation, single phase naturally air cooled indoor type, complete all as specified and directed. |
| 58 | Supply and fix in replacement MCB DP 32 Amps, 240 volts, complete all as specified and directed. |
| 59 | S&F in replacement Copper capillary tube any size suitable for window/split AC, complete all as specified and directed. |
| 60 | Supply and Fixing in replacement Blower for window AC 1.5/2.0 TR as per existing size, complete all as specified and directed. |
| 61 | S&F in replacement Brass Nuts (1/4\\" Dead Nuts), complete all as specified and directed. |
| 62 | S&F in replacement Flair Brass Nuts (1/2\\" Nuts), complete all as specified and directed. |
| 63 | S&F in repalcement Flair Brass Nuts (3/8\\" Nuts), complete all as specified and directed. |
| 64 | S&F in repalcement Flair Brass Nuts (5/8\\" Nuts), complete all as specified and directed. |
| 65 | S&F in repalcement Butane Cartage 414 ml Gas for Brazing/welding AC, complete all as specified and directed. |
| 66 | S&F in repalcement Bakellitet Connecter (for AC Three Connection), complete all as specified and directed. |
| 67 | S&F in repalcement Brass Thimble for AC compressure (100 Pieces), complete all as specified and directed. |
| 68 | S&F in repalcement Copper Brazing Rod, complete all as specified and directed. |
| 69 | S&F in repalcement thread tape, complete all as specified and directed. |
| 70 | S&F in repalcement self adhesive tape (white Cello Tape) size 50mm X 30 m, complete all as specified and directed. |
| 71 | S&F in repalcement PVC insulation tape 25 mm X 25 m, complete all as specified and directed. |
| 72 | Supply and filling refrigerant mafron Gas R-22, complete all as specified and directed. |
| 73 | Supply and filling refrigerant gas R-410, complete all as specified and directed. |
| 74 | Supply and filling refrigerant gas R-404 complete all as specified and directed. |
| 75 | Supply and filling refrigerant gas R-32, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 76 | Supply and filling refrigerant gas R-32, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysDec 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender