Defence Statutory Bodies & Commissions/Committees Closing in 12 days TDR #58645673

Tender For Repair/ Replacement And Cleaning Of Sewage Line In Md Accn And Otm Accn Under Zone ‘A And Zone ‘M Under Ge (North) Bathinda At Bathinda Mil Stn

Issued by Statutory Bodies & Commissions/Committees · Bathinda, Punjab
Tender Value
25 Lakhs
Estimated cost
Bid Submission
04 Dec 2026
12 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bathinda → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Replacement And Cleaning Of Sewage Line In Md Accn And Otm Accn Under Zone ‘A And Zone ‘M Under Ge (North) Bathinda At Bathinda Mil Stn

BOQ

Name of Work:- REPAIR/ REPLACEMENT AND CLEANING OF SEWAGE LINE IN MD ACCN AND OTM ACCN UNDER ZONE ‘A AND ZONE ‘M UNDER GE (NORTH) BATHINDA AT BATHINDA MIL STN
Sl. No. Item Description
1Material and Labour for cleaning and removing blockages from bathroom, kitchen, wash-hand basin (WHB), European water closet (EWC), Indian water closet (IWC), etc., including connected nahani traps, gully traps, floor traps, gratings, waste pipes and drainage pipes up to the first manhole, of any length, choked with mud, sludge or other accumulated deposits, at any location and on any floor, by rodding, mechanical choke remover, high-pressure water jetting, manual cleaning or any other approved method, to the complete satisfaction of the user. The item shall include opening, cleaning and thoroughly washing the traps, pipes and connected drainage system; removing and refixing oval access door covers with new nuts and washers, wherever required; opening and refixing manhole covers; collecting, removing and transporting all waste materials, including solid and liquid sludge, to a suitable pit excavated in an open/empty area at a distance exceeding 50 metres from the building, at the location directed by the Engineer-in-Charge. The item shall also include excavation of a suitable-sized pit, depositing the sludge therein, treating it with bleaching powder by spreading uniformly to reduce foul gases and covering the deposited sludge with excavated earth, including all necessary excavation, earthwork, washing, cleaning, labour, tools, tackles and equipment, complete all as specified and as directed by the Engineer-in-Charge.
2Material and Labour for cleaning and desilting existing underground sewage systems/sewer pipelines of 100 mm, 150 mm and 200 mm diameter, in lengths between manholes not exceeding 20 metres, including cleaning of all connected manholes of any shape (rectangular, square or circular) and situated at any location or site. The work shall include carefully removing the existing manhole covers (CI or RCC), placing them back in their original positions after cleaning, and removing all liquid, solid and semi-solid sludge, silt, mud and other accumulated deposits from the manholes and sewage pipelines by manual rodding or mechanically operated sewage suction pump, as required depending upon site conditions and at the discretion of the contractor. The entire sewage system shall be thoroughly cleaned and restored to proper working condition, ensuring free flow of sewage without any blockage or obstruction, to the complete satisfaction of the Engineer-in-Charge. The item shall also include collecting, removing and transporting all extracted waste, including solid and liquid sludge, in closed containers to a suitable pit excavated in an open/empty area at any distance up to 200 metres from the sewer line/colony area, at the location directed by the Engineer-in-Charge; excavating a suitable-sized pit, depositing the sludge therein, treating it with bleaching powder by uniform spreading to reduce foul gases and covering the deposited sludge with excavated earth, including all necessary excavation, earthwork, labour, tools, tackles, machinery and equipment, complete all as specified and as directed by the Engineer-in-Charge.
3Notes for BOQ Items No. 01 to 02(i) The contractor shall deploy a minimum of four (04) labourers daily for execution of the works.(ii) The contractor or his authorised representative shall report daily at 0900 hours, except on Sundays and National Holidays, to the office of the Engineer-in-Charge/Complaint Cell to receive complaint slips and necessary instructions. Complaints received through telephonic messages from the JE/Engineer-in-Charge shall also be attended to on the same day. The contractor shall report completion of the work to the JE/Engineer-in-Charge by 1700 hours on every working day.(iii) In case of failure by the contractor to attend to any complaint against BOQ Items No. 01 and 02 on the same day, a penalty of Rs. 200/- per complaint per day shall be imposed.(iv) The cost of all necessary tools, plants and equipment (T&P), including green female bamboo strips, iron rods, sewage rodding machines, buckets, ropes, ladders, safety masks, bleaching powder and all other materials required for satisfactory execution of the work, shall be deemed to be included in the quoted unit rates. No extra payment shall be admissible on this account.
4Excavation in trenches in soft / loose soil not exceeding 1.5 meter wide & not exceeding 1.5 meter in depth for foundations of manholes, sewerage pipe lines etc including getting out complete all as specified and as directed by Engineer-in-Charge .
5All as per serial item No 3 here-in-before but exceeding 1.5 meter and not exceeding 3.00 meter in depth. complete all as specified and as directed by Engineer-in-Charge .
6Demolition of ( PCC) cement concrete of any description in any position not exceeding 15 cm thickness complete all as specified and as directed by Engineer-in-Charge .
7Demolition of brick work built in cement mortar including all quoins, pillars etc. but excluding pre-cast cement concrete articles complete all as specified and as directed by Engineer-in-Charge .
8Demolition and breaking up drain pipes SGSW,AC or reinforced concrete pip up to and incl 150mm bore pipes all as specified and directed by Engineer-in-Charge.
9Material and labour for PCC (1:4:8) type D-2 using 40 mm graded stone aggregates as in concrete bed for DWCPE pipes of 150 mm bore, laid to required slope including packing under and haunching against the sides of pipes after they are laid and tested including form work complete all as specified and as directed by Engineer-in-charge. Note :- (i) Thickness of concrete bed below the barrel of pipe shall be 10 cm. (ii) Width of concrete bed shall be outer diameter of drain pipes (not of sockets / collar) plus 30cm.(iii) Excavation , earth work , returning filling shall be measured and paid seperately under appropriate items of schedule 'A' BoQ.
10Material and labour for PCC (1:4:8) type D-2 using 40 mm graded stone aggregates as in concrete bed for DWCPE pipes of 200 mm bore, laid to required slope including packing under and haunching against the sides of pipes after they are laid and tested including form work complete all as specified and as directed by Engineer-in-charge. Note :- (i) Thickness of concrete bed below the barrel of pipe shall be 10 cm. (ii) Width of concrete bed shall be outer diameter of drain pipes (not of sockets / collar) plus 30cm.(iii) Excavation , earth work , returning filling shall be measured and paid seperately under appropriate items of schedule 'A' BoQ.
11Supply , Fixing and testing for providing ,lowering , laying DWCPE (SN 8) pipe of 150mm internal bore as per IS-16098 of 2013, laid in trench and jointed with and including elastomeric sealing 'O' ring and fittings complete all as per manufacturer's instructions , complete all as speified and as directed by Engineer-in-charge. Note:- Excavation , earth work, returning filling , removal ,bedding and pedestal / anchorage if required shall be measured and paid separately under appropriate item of BOQ/ Sch 'A'
12Supply , Fixing and testing for providing ,lowering , laying DWCPE (SN 8) pipe of 200 mm internal bore as per IS-16098 of 2013, laid in trench and jointed with and including elastomeric sealing 'O' ring and fittings complete all as per manufacturer's instructions , complete all as speified and as directed by Engineer-in-charge. Note:- Excavation , earth work, returning filling , removal ,bedding and pedestal / anchorage if required shall be measured and paid separately under appropriate item of BOQ/ Sch 'A'
13M&L Brick work with sub class ‘B’ bricks old size straight or curved on plan exceeding 6 meter mean radius built in CM 1:4 complete all as specified and as directed by Engineer-in-Charge .
14Material & labour for cement concrete 1:4:8 type C-2 using 40 mm graded crushed stone aggregate for foundations, fillings & mass concrete complete all as specified and as directed by Engineer-in-charge.
15Material & labour for cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate for manhole benching and coping complete all as specified and as directed by Engineer-in-charge.
16Material & labour for 15 mm thick cement plaster in CM 1:4 on faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
17Returning/filling in including spreading, leveling , watering & well ramming in layers not exceeding 25 cm thick each all as specified and as directed by Engineer-in-Charge.
18Removal of excavated material to distance not exceeding 1.5 meter above the starting point complete all as specified and as directed by Engineer-in-Charge .
19Cutting into existing manholes for 150 mm dia pipe for connecting new drains, making good to pipe and rendering, cutting out existing benching for and foeming branch channel (1/2 round or3/4 section) in cement concret 1:2:4 type B-1 smooth finished and reforming benching complete all as specified and directed.
20Supply & Fixed in repair SFRC (Steel fibre reinforced concrete) cover and frame (heavy duty HD-20 grade designation) size of cover area not exeeding 0.85 Sqm conferming to IS 12592, fixed in cement cocrete 1:2:4, complete all as specified and directed by Engineer-inCharge.
21M&L for Cleaning of 150 mm dia DWCPE /SGSW / PVC pipe sewage line cleaning with only by pressure with mechanically and removal blockage and foreign material.
22M&L for Cleaning of 200 mm dia DWCPE /SGSW / PVC pipe sewage line cleaning with only by pressure with mechanically and removal blockage and foreign material.
23Dismantling and disconecting of existing cast iron soil vent pipe fixed to wall or laid in trenches incl all fitting accessories including removal of shrubs as directed by Eng-in-charge.
24Supply and fix PVC (SWR) pipe single socketed, in any length with rubber ring joints and fixed to walls and similar work etc 110mm dia bore of pipe incl fittings, complete all as specified and directed.
25Supply and fix PVC (SWR) pipe single socketed, in any length with rubber ring joints and fixed to walls and similar work etc 75 mm dia bore of pipe incl fittings, complete all as specified and directed.
26S&F in repair PVC (SWR) floor trap with CP grating including jointing with solvent cement of 75 mm dia fixing and making good with PCC 1:2:4 type B1
27S&F in repair PVC (SWR) floor trap with CP grating including jointing with solvent cement of 100 mm dia fixing and making good with PCC 1:2:4 type B1
28S&F in repair stack clamps 50mm by 5mm flat iron round including bolts and nuts for fixing of pipe any size dia upto 110mm and securing ends of stays to wall etc complete all as specified by Engr-in-charge.
29S&F in repair stack clamps 50mm by 5mm flat iron round including bolts and nuts for fixing of pipe any size dia upto 75 mm and securing ends of stays to wall etc complete all as specified by Engr-in-charge.
30S&F in repair PVC (SWR) bend 75 mm dia.
31S&F in repair PVC (SWR) bend with access door 75 mm dia.
32S&F in repair PVC (SWR) bend 110 mm dia.
33S&F in repair PVC (SWR) bend with access door 110 mm dia.
34S&F in repair PVC (SWR) junction single ( single T) equal or unequal 75mm dia
35S&F in repair PVC (SWR) junction single ( single T) equal or unequal 100/110 mm dia
36Removing man hole cover including earth soil spread over the cover if any from the frame of septic tanks and receiving chambers remove all night soil, sediments waste materials of any size etc irrespective of its height clear off upto the bottom floor mechanically using super jetting machine or by suitable means as ordered anf dispose off the materials out side of MD land from the septic tank using mechanical vehicle (Tanker) to pit suitably excavated to contain night soil placing back the main hole cover to its orignal position and removing all vegetable roots if any and making good surrounds complete all as directed.
37Removal of sludge/ earth soil ,sediments ,waste materials of any size manholes not exceeding 1.5 mtr in deapth
38Removal of sludge/ earth soil ,sediments ,waste materials of any size manholes exceeding 1.5mtr and not exc 3.00 mtr Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58645673
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25 Lakhs
LAST DATE 04-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Replacement And Cleaning Of Sewage Line In Md Accn And Otm Accn Under Zone ‘A And Zone ‘M Under Ge (North) Bathinda At Bathinda Mil Stn
Basic Detail
Tender No 8941/NIT-65/26-27/E8
Bidding Type Tender
Location
City Bathinda
State Punjab
Key Dates
Publish Date 20 Nov 2026
Submission Date 04 Dec 2026
Open Date 07 Dec 2026
Finance
Tender Value 25 Lakhs
Tender Fee 500
EMD 50000
Exemption Available
Document List
5c44fd7e-70a6-4b06-aed0-afa0fe12e987.html
BOQ_897176.xls
tenderdocuments65.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

5c44fd7e-70a6-4b06-aed0-afa0fe12e987.html

xls

BOQ_897176.xls

pdf

tenderdocuments65.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender