Tender For Special Repair To Roof Treatment Of Bldg No P-19, P-20, P-21 And P-22 Of 181 & 203 Pet Pl Asc Under Ge (East) Jalandhar Cantt (Tender Id No 2026_Mes_799571_1)
Tender Value
46.01 Lakhs
Estimated cost
Bid Submission
11 Dec 2026
19 days left
EMD
92030
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jalandhar → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To Roof Treatment Of Bldg No P-19, P-20, P-21 And P-22 Of 181 & 203 Pet Pl Asc Under Ge (East) Jalandhar Cantt (Tender Id No 2026_Mes_799571_1)
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of brick tiles single layer as in roof covering, complete all as directed by Engr-in-charge. |
| 2 | Demolition of Mud in roofs any thickness including plastering and leeping(whether full thickness removed or only a part thereof), complete all as directed by Engr-in-charge. |
| 3 | Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing) and disposal of rubbish outside MD land, complete all as directed by Engr-in-charge. |
| 4 | M&L for 18 to 20 mm thick machine in cut kota stone slab flooring over and incl 15mm thick bedding layer CM 1:6 in roughening of old concrete floor surfaces by picking, sweeping clean and washing down with water to remove dust inc brushing neat cement slurry with 3 kg/sqm with pigments to match the shade of slab including cutting, rubbing and mirror/granite finish polishing including taking down old stone slab, complete all as specified and as directed.Charge. |
| 5 | M&L for PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in benching, roof padding, roof kerbs or mud stops, coping etc rounded or chamfered on edges, complete all as specified and as directed. |
| 6 | M&L Cutting out cracks to V-section in existing RCC roof slabs or terracing , cleaning out & filling solidly with a hot mixture of bitumen and clean dry sand 1:1 ( by weight) , complete all as specified and as directed. |
| 7 | M&L 10mm thick cement plaster in cement mortar (1:3) on concrete roof surfaces finished even and fair, including cleaning the roof top by water etc , complete all as specified and as directed. |
| 8 | Cleaning the surface and made free of dirt, foreign particle, laitance followed by grinding all all protrusion to make surface modulated. Thereafter, inspection for cracks on the surface caused by thermal expiation contraction. Cutting the grooves with suitable cutter machine in V groove filled with repairs mortar/ microconcrate / general purpose grout as recommended proportionally as per recommendation of manufacture. Making of Gollas at all the corners with polymer modified mortar (1:4) cement sand with 3.5% acylic of cement weight, complete all as directed by Engr-in-charge. |
| 9 | supply and applying high build elastomeric waterproofing coating based on pure hydrophobic polyurethane cold appliId of spray/brush applied, membrane with an elongation of 280% and tensile strength of 2.7N/mm2 as per ASTM D 2370, crack bridging ability of 3mm, no leakage upto 5 bars of water pressure as per DIN 1048, min 88% solid content. The system includes final base preparation, epoxy primer 1:1 (Resin; harder) application with 100% water dilution and Pure polyurethane application in 2 coats with a total min consumption of 1.25 kg per Sqm incl fiber mesh Application should be done with Graco sprayer by a company authorised applicator ”, complete all as specified and as directed. |
| 10 | M&L Galvanised iron water tubing 15 mm bore, medium grade with & including all fittings fixed to wall, ceilings and or laid in floors etc including taking down the existing tubing, complete all as specified and as directed. |
| 11 | M&L Galvanised iron water tubing 20 mm bore, medium grade with & including all fittings fixed to wall, ceilings and or laid in floors etc including taking down the existing tubing, complete all as specified and as directed. |
| 12 | M&L Galvanised iron water tubing 15 mm bore, medium grade with & including all fittings fixed to wall, ceilings and or laid in floors etc including taking down the existing tubing, complete all as specified and as directed. |
| 13 | S&F for 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed,, complete all as specified and as directed. and directed. |
| 14 | Disconnecting existing tanks 1000 Ltrs setting aside (or lowering if required) for repair, cleaning and hoisting if required reconnecting and refixing in position, complete all as directed by Engr-in-charge. |
| 15 | S&F 500 ltr rotational moulded polythylene anti microbial water storage tank (Cylindrical vertical with closed top) hosted and fixed in position incl dismantling of existing tank of any description, complete all as specified and as directed..ISI marked. |
| 16 | S&F 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight-210gms.), complete all as specified and as directed. |
| 17 | Demolition and braking up drain pipes AC/PVC pipe in event n.exc 150 mm dia including all fittings, complete all as directed by Engr-in-charge. |
| 18 | S&F for 110 mm PVC (SWR) Rain water pipes single socketed in any length with rubber ring joints fixed to walls), complete all as specified and as directed. |
| 19 | PVC (SWR) bends 110 mm, complete all as specified and as directed. |
| 20 | Demolition of brick work built in cement mortar incl all quions, arches pillars etc but excludding precast concrete articles, complete all as directed by Engr-in-charge. |
| 21 | M&L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6 M mean radius built in CM (1:6, complete all as specified and as directed. |
| 22 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc and removing surplus spoil out of Defence Land where directed at a level not exc 1.5 m above the starting poin, complete all as directed by Engr-in-charge. |
| 23 | M&L 15mm thick cement plaster in cement mortar 1:4 on external surface brick or concrete surface finished even and fair, complete all as specified and as directed. |
| 24 | M&L for prepration of new surfaces of walls including cornices, plasters etc (Plastered or unplastered surfaces) and applying two coats of cement base paint over a coat of primer, complete all as specified and as directed. |
| 25 | M&L complete removal of the existing tratement on walls for Preparation of wall surfaces by scrapping (any No of layers), rubbing down, washing, etc as directed and apply two coats of cement base paint all as directed and specified. |
| 26 | M&L complete removal of the existing tratement on walls for Preparation of wall surfaces by scrapping (any No of layers), rubbing down, washing, etc as directed and apply a uniform layer of wall care putty as approved after that let the surface dry then apply two coats of oil bound distemper white or tinted, complete all as specified and as directed. |
| 27 | M&L for prepration of old surfaces of walls including scraping down smoke soots, moulds, moss and trading oil and greasy spots etc including cornices, pilasters etc( Plastered or un plastered surfaces) and applying two coat of white (lime) wash on ceiling, complete all as specified and as directed. |
| 28 | M&L for dismantling of existing Solar Water Heating System capacity 1000 LPD complete with all connected accessories, installed, and depositing to MES store yard without damage for refunctioning and reinstalling back after completion of roof treatment at same location along with all necessary electrical connection, complete all as specified and as directed. |
| 29 | M&L for dismantling of existing Solar Water Heating System capacity 500 LPD complete with all connected accessories, installed, and depositing to MES store yard without damage for refunctioning and reinstalling back after completion of roof treatment at same location along with all necessary electrical connection after completion of roof treatment at same location along with all necessary electrical connection, complete all as specified and as directed. |
| 30 | M&L for sub main wiring in replacement with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 4.0 Sqmm drawn through in and including new PVC rigid non metallic conduit (medium grade) with all fittings including earth continuity single wire FRLS PVC insulated unsheathed multistranded copper conductor cable 4.0 Sqmm (green insulation) with any type of civil work including making good to disturbed surfaces to match existing surface, complete all as specified and as directed.. NOTE: Two run of 4.0 sqmm wire and one run of 4.0 sqmm wire as earth wire including PVC conduit shall be measured as one unit, complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysDec 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender