Public Administrative Department Government Departments Closing in 20 days TDR #58645422

Tender For Development Of Approach Road Of Jhakarkati Modern Bus Terminal.

Issued by Government Departments · Kanpur, Uttar Pradesh
Tender Value
29.55 Crore
Estimated cost
Bid Submission
19 Dec 2026
20 days left
EMD
1.70 Crore
Bank guarantee accepted
Document Fee
42126
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Development Of Approach Road Of Jhakarkati Modern Bus Terminal.

BOQ

Name of Work:- DEVELOPMENT OF APPROACH ROAD OF JHAKARKATI MODERN BUS TERMINAL.
Sl. No. Item Description
1ROAD DEVELOPMENTEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil
2Construction of granular sub base (GSB) by providing coarse graded material, spreading in uniform layer with mortar grader on prepared surface, mixing by mix in place method with rotovator at OMC & compacting with vibratory roller to achieve the desired density as per clause 401. Close graded granular sub- base Material as per table 400-1. Grading- I Material.
3P/L spreading compacting graded stone aggregates to wet mix macadam specification including premixing the material by tipper to site laying in uniform layers with pavers in sub base course on well prepared surface and compacting with vibratory roller inclunding labour material T&P etc all complete.
4Providing and laying cement concrete in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, Including cost of form work. In Foundation and floors.
5CONSTRUCTION OF PCC ROAD: Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M40 grade with minimum cement content of 400 kg /cum
6Solar Power road marker (Solar Studs)The solar studs shall be made of Aluminium alloy and poly carbonate material which shall be absolutely weather resistant and strong enough to support a load of 13,635 kg tested in accordance with ASTM D4280. Its colour may be white, red, yellow, green or blue or combination as directed by the Engineer, Its water resistance shall meet the requirements of IP 65 in accordance with 15:12063:1987 category 2 for protection against water ingress. The dimensions of solar studs shall not be less than 100 mm X 100 mm X 10 mm, it shall have super bright LEDs so as to provide long visibility from a distance of more than 800 m. Its flashing rate shall not be less than 1 Hz Its should be able to give the prescribed performance in the temperrature range of 40°C to +55°C. Its life shall be not less than 3 Years. The rate shall include all materials, labour, equipments, fabrication, transportation, erection, installation and incidentals all complete as per direction of the Engineer-in-Charge.
7Reflective Raised Pavement Markers (Cat Eye/ Road Stud):-Supply and fixing of raised pavement marker with Made of Plastic body of RPM/ Road Stud shall be moulded from ASA (Acrylic Styrene Acrylonitrite) or HIPS (High-Imoact Polystyrene) or Acryloniitrite Butadien Styrene (ABS) or Any other suitable material approved by the Engineer. The Marker shall support a load of 13,635 kg tested in accordance with ASTM D4280. The Reflective panels shall consist of number of lenses contatning single or dual prismatic cubes capable of providing total internal reflection of the light entring the lens face. Lenses shall be mouled of methyl methecrylate conforming to ASTM D788 of equivalent. The slop or retro-reflecting surface shall preferably be 35+/-5 degree to base and the area of each retro-reflecting surface shall not be less than 13.00 sq.cm. the marker height shall not be less than 10 mm and shall not exceed 20 mm & Width shall not exceed 130 mm. The base of the marker shall be flat within 1.3 mm all road studs shall be legibly marked with the name, trade or other means of identification of the manufacture, epoxy installations, excess adhesive around the edge of the marker, excess adhesive on the pavement and adhesive on the exposed surfaces of the markers shall be immediately removed. The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer. In addition, a two year warranty for satisfactory infield performance of the finished road marker shall also be given by the contractor who carries out the work of fixing of reflective road markers. In case the markers are displaced, damaged get worn out or lose their reflectivity compared to stipulated standards, the contractor would be required to replace all such markers within 15 days of the intimation from the Engineer, at his own cost. The rate shall include all materials, labour, T&P, transportation, installation and incidentals all complete as per direction of the Engineer-in-Charge.RPM (with shank)
8Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50 m x2.00 m made of 40x40x6 mm angle iron or 50x50x3 mm hollow MS tube posts/horizontal members/bracings covered with 1.63 mm thick MS sheet. The sheet shall be fixed with 30x5 mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5 m. MS channel ISLC 75 @ 5.70 kg/m, 50 cm long shall be provided at the bottom having oval shaped holes of size 50x25 mm at both ends with 50 cm long MS angle 40x40x6 mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250 mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site forday and night, glow lamps, reflective signs, marking, flags, caution tapeas directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously including shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenanc for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work including shifting. The barricading provided shall remain to be the property of the contractor on completion of the work).
9TABLE TOPS AND RAISED INTERSECTION : Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M40 grade with minimum cement content of 390 kg /cum
10Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads onBituminous Surface. Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35-2015 The finished surface to be level, uniform and free from streaks and holes.
11Providing, installing, maintaining and dismantling temporary steel sheet pile cofferdam for execution of foundation works in water body, comprising supply on hire of steel sheet piles of minimum 20 m length, driving by vibratory hammer/impact hammer to the required depth, providing all necessary guide frames, walers, struts, tie rods, bracing, cutting shoes, lifting arrangements and all ancillary materials, including mobilization and demobilization of cranes, piling equipment, generators and accessories, dewatering, maintenance of a dry working area throughout the construction period, extraction of sheet piles after completion of foundation work, backfilling of voids, disposal of surplus material and restoration of the site to its original condition, complete in all respects as per the approved drawings, specifications and directions of the Engineer-in-Charge.
12FOOT PATH DEVELOPMENTDismentaling cement concrete or brick work or granolithic floor including stacking of dismantaled material as directed by Engineer-in- Charge within s distance of 60 meter.
13Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil
14Providing and laying in position cement concrete of specified grade 1:4:8 (1 Cement : 4 coarse sand derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources
15Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineerin-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge)
16Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge.
17Supply and fixing Gully Grates RED 048 GRH-300 750 mm D.I. GULLY GRATE & FRAME IN D400 LOAD CLASS, as per BS EN 124 Black Bitumen Paint, all complete as per direction of Engineer-in-charge, (For Storm Water On Road Grating)
18Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M30 grade with minimum cement content of 350 kg /cum
19Applying stamping finish to the top surface of freshly laid plain/reinforced cement concrete of specified grade in porticos, sidewalks, driveways, pool decks and open yards as per direction of the Engineer-in-Charge. The process shall include the following:- • The concrete shall be placed and screeded to the finished grade, and floated to a uniform surface by using standard finishing techniques. The approved color hardener @ 2.7 kg/sqm shall be applied evenly to the surface of the fresh concrete by the dry shake method by sprinkling in two or more shakes, floated after each shake and trowelled only after the final floating. The approved release agent @ 0.113 kg/sqm shall be applied evenly to the trowelled surface before stamping or the said release agent can be applied to the flexible polyurethane stamp moulds of approved design and in required sizes to achieve final stamped pattern. These stampings shall be placed on the surface of concrete in three to four pieces at a time and tapped gently with rammers of sufficient size & weight to leave proper stamp marks and the process repeated for the remaining concrete surface till the whole surface to be stamped is completed within the time while concrete is in plastic stage of setting. • After stamping, the curing shall be done as per manufactures specifications. After initial curing the imprinted joints shall be grouted using cement slurry mixed with color hardener as per the requirement. The surface shall be sealed by applying acrylic based sealer not less than 0.167 litre/sqm.on finished surface. • The construction joints shall be provided by groove cutting of size 4 mm x 20 mm in panel size 3m x 3 m or lesser as per the site conditions and filling the same with 10 mm baker rod and providing and laying (PU) Polyurethane based joint sealer of approved make as per manufacturer’s specifications and finished by applying Polyurethane resin based top protective clear coat of minimum 80 micron applied with rollers on properly cured and dry clean surface. (Cost of concrete for flooring is not included in this item which shall be paid separately.)
20Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
21Finishing walls with exterior emulsion paint (Apex) of approved brand and manufacture and of required shade on undacorated well surface to give even shade over 1.25 Ltr/10sqm including one coat of primer applid 0.75Ltr/10sqm coat curing and cost of all material, labour, T&P etc. required for proper completion of work for two coat.
22Precasting and placing in position 125 mm dia Bollards 600 mm high of in specified spacing. cum 8514.85 cum cum cum Recycled required shape including providing M.S. Pipe Sleeve 50 mm dia 300 mm long in the Bollard and M.S. Pipes 40 mm dia and 450 mm long with 150x150x6 mm M.S. plate welded at bottom and embedded 150 mm cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-lll) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources), including necessary excavation of size 250x250x450 mm deep for the same in bitumen/concrete pavement at
23Steel work welded in built up sections/ framed work, Including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required,in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
24Painting or Varnishing on iron works in small areas or new wood work with one coat of ready mixed priming paint & one coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials labour and T&P etc. required for proper completion of the work paint to be used should confirm.
25Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. cum Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying
26EARTH FILLINGExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
27R.C.C RETAINING WALL (LENGTH &7.5 MT DEPTH)Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
28Providing and laying cement concrete in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, Including cost of form work. In Foundation and floors.
29Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Concrete of M30 grade with minimum cement content of 350 kg /cum UPTO PLINTH LVL
30Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) : 1000 mm dia piles
31P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
32Providing weep holes in reinforced concrete abutment, wing wall, return wall with 100mm dia AC pipe extending through the full width of the structure slope of 1 (V) 20 (H) towards drawing face complete.
33Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600mm with snaller size towards the wall and providing over the entire surface behined abutment, wing wall return wall to the full height compacted to firm condition complete as per drawing and technical specification clauses 1204.3.8.
34Brick work with common burnt clay F.P.S. (non modular) bricks of class 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
3512 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. On plinth.
36Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
37Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
38Steel work welded in built up sections/ framed work, Including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required,in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
39Painting or Varnishing on iron works in small areas or new wood work with one coat of ready mixed priming paint & one coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials labour and T&P etc. required for proper completion of the work paint to be used should confirm.
40Centering and shuttering(i) Foundations, footings, bases of columns, etc. for mass concrete
41Centering and shuttering(ii) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
42R.C.C RETAINING WALL (LENGTH & 9.0 MT DEPTH)Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
43Providing and laying cement concrete in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, Including cost of form work. In Foundation and floors.
44Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Concrete of M30 grade with minimum cement content of 350 kg /cum UPTO PLINTH LVL
45Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) : 1000 mm dia piles
46P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
47Providing weep holes in reinforced concrete abutment, wing wall, return wall with 100mm dia AC pipe extending through the full width of the structure slope of 1 (V) 20 (H) towards drawing face complete.
48Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600mm with snaller size towards the wall and providing over the entire surface behined abutment, wing wall return wall to the full height compacted to firm condition complete as per drawing and technical specification clauses 1204.3.8.
49Brick work with common burnt clay F.P.S. (non modular) bricks of class 150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
5012 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. On plinth.
51Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
52Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
53Steel work welded in built up sections/ framed work, Including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required,in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
54Painting or Varnishing on iron works in small areas or new wood work with one coat of ready mixed priming paint & one coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials labour and T&P etc. required for proper completion of the work paint to be used should confirm.
55UTILITY DUCTEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil
56Providing and laying in position cement concrete of specified grade 1:4:8 (1 Cement : 4 coarse sand derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources
57Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. (PN-6: Class PE-100)63mm dia (OD-63mm & ID-51mm Nominal
58Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. (PN-6: Class PE-100)90mm dia (OD-90mm & ID-76mm Nominal
59STORM WATER DRAINAGE WORKEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil
60Providing and laying in position cement concrete of specified grade 1:4:8 (1 Cement : 4 coarse sand derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources
61Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. 600 mm dia RCC pipes. 600 mm dia RCC pipes.
62Supplying and fixing D.I. cover without frame for manholes : D.I. cover (medium duty) D.I. cover B125 class. maximum load rating of 20.00 tonnes.
63Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete
64Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class
65Construction of granular sub base (GSB) by providing coarse graded material, spreading in uniform layer with mortar grader on prepared surface, mixing by mix in place method with rotovator at OMC & compacting with vibratory roller to achieve the desired density as per clause 401. Close graded granular sub- base Material as per table 400-1. Grading- I Material.
66Construction of R.C.C. Storm water Chamber for 600mm RCC pipe with cover.
67Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. cum Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying
68LANDSCAPING AND HORTICULTURE WORK ON DIVIDERUprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts
69Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
70Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm.
71Spreading of sludge, dump manure or/and good earth in required thickness (cost of sludge dump manure or/and good earth to be paid separately).
72Carrigae of manure upto 5 K.M.
73Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.
74Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)
75Supplying & Stacking of Selection No.1/doob grass at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge.
76Cutting of Hedge/Edge including removing of cut material, cleaning, hoeing of hedge/edge bed watering, manureing and applying insecticides and fungicides etc.(excluding the cost of material which shall be supplied by Per Sqm the department) and as per direction of officer in charge.
77Plantation of Flowers:Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35- 40 cm well developed in big size HDPE bags as per direction of the officer-in-charge.
78Anemone hybrid (3 in one) variety well developed with fresh & healthy Flower in full bloom in 25 cm Earthen Pot/Plastic Pot.
79Polyalthia pendula (Ashok Pendula) height 180-195 cm. in gunny bag size 30 cm
80Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.
81Supply, transportation, and fixing of precast reinforced concrete tree gratings of approved design, shape, and size as per drawings and instructions of the Engineer-in-Charge. The tree gratings shall be manufactured using M-30 grade concrete with adequate reinforcement to ensure durability and load-bearing capacity. Surface shall be finished smooth, edges chamfered, and openings accurately formed for proper fit around the tree trunk and aeration/irrigation. The gratings shall be factory-cast, cured for a minimum of 14 days, and free from cracks, honeycombs, or other defects. Installation shall include proper leveling, alignment, and setting over a compacted sand/cement bed or as directed.
82COST OF BORING PUMP SUBMERSIBLE
83STREET LIGHT WORK:Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length each ) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.
84S/F of LED Street light fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 watt. Confirming to IP-66 protection complete in all respects. CAT-AAA
85Supply & fixing of 4.5 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length each ) on RCC foundation including the cost of 15 to 25 watt LED Light, foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.
86S/L of aluminium conductor PVC insulated armoured served shethed cable 1100 volts grade at a depth of 750 mm below ground level over cushion of 75 mm thick sand all around and protected with burnt bricks on sides and top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or directed by the E/I complete in all respect,the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 10 sq mm 2 core.
87Supply and fixing following capicity of autometic street light cubical cntrol panel with anticorrosive alkali and acid proof paint consisting of time swich TSO 100 series with contactors. HRC fuses solating switch metering instrument & instrument box with CTs etc in case of TPN. Complete in all respect (25 A TNP).
88Supply and burying of 40mm dia x 4.5mtr long G.I. pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 mtr. form the bottom complete with earthing lead of no. 6 to 8 SWG G.I. wire in GI pipe up to apron (and from apron to switch board the cost of GI wire and pipe will be extra) upto switch board 30cm sq. G.I. box with hinged over masonry enclosure, foundation at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-incharge complete in all respects as per drawing.
89Numbring of EL pole 6''x4'' size black enamel paint and around thr number white enamel pain comp in all respects.
90Supply and wiring of submain with two number 4 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with one number 14 SWG copper earth continuity wire including matching colour wash etc. complete in all respect. for connection of LED Fitting
91S&F of 6 Amp to 32 Amp. SP MCB (10 KA) C Curve CAT-A
92Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as perdirection of the Engineer-Incharge. 10sq.mm.
93Cutting & Repairing of footpath.
94HIGHMAST LIGHTS/F of Steel Tubular pole 9.5 meter long designated 410 SP-39 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect.
95S/E of D clamp of 50x6 mm flat iron steel tubular poles/rail poles with nut bolts etc. complete in all respects. including painting with aluminium paint.
96S/F of 75x90 mm shackle insulator/ 100x 65 mmpin insulator including G.I.bolt spindles nuts etc . complete in all respect.
97S/E of stay set at 3.5 Meter away from thepole complete with galvanized 19 mm diax1.80 Meter long stay rod 30 cmx30x6.3 mm anchor plate,thimble stay clamps ,stay insulator,19 mm 600mm double screw tightener, 7/3.5 mmG.I. stay wire etc. in 1:3:6 cement concrete. complete in all respect.
98Painting of electric pole with 2 coat of aluminium paint over red oxide primer complete in all respect
99S/F of 800 watt Algoritham based Automatic high mast Tower switch I.P 67 Box water Proof. Complete in all respect
100Numbring of EL pole 6''x4'' size black enamel paint and around thr number white enamel pain comp in all respects.
101S/L ofaluminium conductor PVC insulated armoured served shethed cable 1100 volts grade at a depth of 750 mm below ground level over cushion of 75 mm thick sand all around and protected with burnt bricks on sides and top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or directed by the E/I complete in all respect,the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 10 sq mm 2 core.
102Supply and burying of 40mm dia x 4.5mtr long G.I. pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 mtr. form the bottom complete with earthing lead of no. 6 to 8 SWG G.I. wire in GI pipe up to apron (and from apron to switch board the cost of GI wire and pipe will be extra) upto switch board 30cm sq. G.I. box with hinged over masonry enclosure, foundation at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-incharge complete in all respects as per drawing.
103s/f of 4/6 arm bracket complete in all respect.
104S/F of factory wired integral L.E.D. Flood Light Luminaires with dia cast Al body built with driver set suitable for 170 watt to 200 watt confirming IP 66 protection complete in all respect.CAT-AA ISI Mark
105Add 2% Contingencies Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58645422
AUTHORITY Government Departments
TENDER VALUE 29.55 Crore
LAST DATE 19-12-2026
Authority
Authority Name Kanpur Municipal Corporation
Work Description Tender for Development Of Approach Road Of Jhakarkati Modern Bus Terminal.
Basic Detail
Tender No 74/EE/P/26-27
Bidding Type Tender
Location
City Kanpur
State Uttar Pradesh
Key Dates
Publish Date 20 Nov 2026
Submission Date 19 Dec 2026
Open Date 19 Dec 2026
Finance
Tender Value 29.55 Crore
Tender Fee 42126
EMD 1.70 Crore
Exemption Not Available
Document List
8610df52-23e3-478c-baa8-4e9f15ceb876.html
BOQ_2300700.xls
DevelopmentofApproachRoad_1.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Dec 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

8610df52-23e3-478c-baa8-4e9f15ceb876.html

xls

BOQ_2300700.xls

pdf

DevelopmentofApproachRoad_1.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender