Tender For Construction Of Underground Ducting Arrangement Of Cesc Main Cable Line For Whole Campus And Laying Of Cable From Main Bus Bar To Each Flat Of 06 Nos Block I.E Block A1 & A2, D1 & D2 And E1 & E2 Of Bidhan Shishu Udyan Police Housing Estate
Tender Overview
Project Description
Tender for Construction Of Underground Ducting Arrangement Of Cesc Main Cable Line For Whole Campus And Laying Of Cable From Main Bus Bar To Each Flat Of 06 Nos Block I.E Block A1 & A2, D1 & D2 And E1 & E2 Of Bidhan Shishu Udyan Police Housing Estate, Kolkata.
BOQ
| Sl. No. | Item Description |
| 1 | Civil Works Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and inany floor including removing rubbish within alead of 75m as directed. |
| 2 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](i) With 1:6 cement mortar(c) 15 mm thick plaster |
| 3 | Brick work with 1st class bricks in cement mortar (1:6)(a) In foundation and plinth |
| 4 | Cutting holes and subsequent mending gooddamages.(ii) In concrete work (plain or R.C.)[Cement-4.6 Kg/Mtr](b) Diameter exceeding 150 mm. but notexceeding 300 mm. |
| 5 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. |
| 6 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receiveDistemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification andas per direction of the EIC. (In Ground Floor)(b) Two Coatsii) Solvent based interior grade Acrylic Primer |
| 7 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats)ii) Luxury Quality |
| 8 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 9 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) |
| 10 | (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sandpapering etc. |
| 11 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface : With super gloss (hi-gloss) -(ii) Two coats (white in shade) |
| 12 | Earth work in excavation of foundation trenches ordrains, in all sorts of soil (including mixed soil butexcluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm |
| 13 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation |
| 14 | Removal of rubbish,earth etc. from the workingsite and disposal of the same beyond thecompound, in conformity with the Municipal /Corporation Rules for such disposal, loading intotruck and cleaning the site in all respect as perdirection of Engineer in charge |
| 15 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as perrelevant IS codes.Pakur variety |
| 16 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in 1st floor as perrelevant IS codes.Pakur variety |
| 17 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in 2nd floor as perrelevant IS codes.Pakur variety |
| 18 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in 3rd floor as perrelevant IS codes.Pakur variety |
| 19 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in 4th floor as perrelevant IS codes.Pakur variety |
| 20 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in 5th floor as perrelevant IS codes.Pakur variety |
| 21 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in 6th floor as perrelevant IS codes.Pakur variety |
| 22 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in 7th floor as perrelevant IS codes.Pakur variety |
| 23 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in 8th floor as perrelevant IS codes.Pakur variety |
| 24 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in 9th floor as perrelevant IS codes.Pakur variety |
| 25 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in 10th floor as perrelevant IS codes.Pakur variety |
| 26 | Cement concrete with graded jhama khoa (30 mm size) excluding shutteringIn ground floor and foundation.(a) 1:3:6 proportion |
| 27 | Controlled Cement concrete with well graded stone chips (20 mm graded nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of jobmix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be lessthan 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]M 20 Grade |
| 28 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 29 | Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in allrespect with all labour and material.[Border concrete if necessary to be paid separately].Note: Sub-grade CBR should not be less than 5.a) 25 mm thick Tiles as per IS: 1237-2012 forfootpath,ramp,staircase of public building(over 25 mm thick (Avg) Cement mortar (1:3) & Cement Slurry @ 4.4 kg/Sq.m at back side of Block. Cement for Mortar & Slurry to be supplied by Department).(ii) Coloured Decorative |
| 30 | Dismantling all types of plain cement concreteworks, stacking serviceable materials at site andremoving rubbish as directed within a lead of 75m.In ground floor including roof.(a) upto 150 mm. thick |
| 31 | A) Filling in foundation or plinth by silver sand inlayers not exceeding 150 mm as directed andconsolidating the same by thorough saturation withwater, ramming complete including the cost of supplyof sand. (payment to be made on measurement offinished quantity)B) Do - by fine sand |
| 32 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking andbending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 mI. SAIL/ TATA/RINL |
| 33 | Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes conforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with Ring Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIRvalue not more than 10% including necessary jointing materials for nonpressure underground Drainage, Sewerage & Cross drainage application.(i) 150mm internal dia. |
| 34 | Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides,bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to insidewalls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as perdirection, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcementsupto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved makesupplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoilsafter work complete in all respect with all costs of labour and materialsi) With Pakur variety. (SAIL/TATA/RINL) |
| 35 | Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes conforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with Ring Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIRvalue not more than 10% including necessary jointing materials for nonpressure underground Drainage, Sewerage & Cross drainage application.(vi) 500mm internal dia |
| 36 | Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes conforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with Ring Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIRvalue not more than 10% including necessary jointing materials for nonpressure underground Drainage, Sewerage & Cross drainage application.(iv) 300mm internal dia. |
| 37 | Electrical Works (Schedule Work) S & F 415V 315A TPN Switch fuse Unit with SS enclosure on Angle frame (make L & T) on wall with nuts bolts etc. incl. S & F 3 no DIN type HRC fuse. (PWD SOR D-3/4-a) |
| 38 | S & F 415V 125A TPN Switch fuse Unit with SS enclosure on Angle frame (make L & T) on wall with nuts bolts etc. incl. S & F 3 no DIN type HRC fuse. (PWD SOR D-3/4-a) |
| 39 | S & F 415V 63A TPN Switch fuse Unit with SS enclosure on Angle frame (make L & T) on wall with nuts bolts etc. incl. S & F 3 no DIN type HRC fuse. (PWD SOR D-3/4-a) |
| 40 | S & F 415V 6-10A perway (2+4 way) SPN MCBDB with SS enclosure double door with IP 42/43 protection with 2 pole 32 Amp isolator as incomer & 4 nos SPMCB C curve 10KA SPMCBs as outgoing concealed in wall after wall cutting & mending good the damages to original finish including interconnection with suitable size of Cu wire neutral link & earthing attachment (Make Legrand). [PWD Sor, Page D-9/13, D-5/6 & D-6/7] |
| 41 | Distn. wiring in 3 x 1.5 sqmm single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Gloster/Finolex/Havells) in 20 mm size PVC rigid conduit 'FR' (Precision make) in (for ceiling portion only) and in 19 mm bore, 3 mm thick polythene pipe (for horizontal & vertical run embedded in wall, with 1x1.5 sq.mm single core stranded 'FR'PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points complete with 2 no. \\"Ph & N\\"copper bar with Modular type switch (Legrand/Crabtree) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish (Ave run 8 mtr )[PWD Sor, Page E-15/5(c)] |
| 42 | Laying of XLPE/A cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed a) upto 35 sq mm [ PWD SOR, page-F-2, 1 ( a ) ] |
| 43 | Laying of 95 sq mm XLPE/A cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. [PWD SOR, Page F-2, 1 ( b) ] |
| 44 | Laying of upto 35 sq.mm PVC /A Cable after cutting of wall at an averagedepth of 75 mm and mending good the damages to original finish incl. Removing the rubbish. [ PWD SOR,Page F-3, 5 ( i ) ] |
| 45 | Laying of upto 25 sq.mm PVC /A Cable on wall/surface incl. S&F saddles with earthing attachment in 10 SWG GI (Hot dip) wire,making hole etc. as necy. mending good the damages and painting. [PWD SOR, Page F-1, 2 ( a ) ] |
| 46 | Laying of 95 sq.mm PVC /A Cable through existing RCC/Hume/GI Pinpe/ Open masonary trench for single, 2, 3, 3.5 and 4 core. [PWD SOR, Page F-1, 3 ( b ) ] |
| 47 | S & F compression type cable gland complete with brass gland, brass ring, rubber ring for dust & moisture proof entry of PVC armoured cable & finishing end of the same as per GS a)3.5 core 95 sqmm PVC/A cable [PWD SOR, Page F-4/7 ( d), F-5/8 ( b/xiii ) ] |
| 48 | S & F compression type cable gland complete with brass gland, brass ring, rubber ring for dust & moisture proof entry of PVC armoured cable & finishing end of the same as per GS a)3.5 core 35 sqmm PVC/A cable [PWD SOR, Page F-4/7 (d ), F-5/8 ( b/xv ) ] |
| 49 | Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable: a) 2 core 16 Sqmm PVC/A Cable [PWD SOR, Page F-4/7(a), F-5/8(b)(iv)] |
| 50 | S & F compression type cable gland complete with brass gland, brass ring, rubber ring for dust & moisture proof entry of PVC armoured cable & finishing end of the same as per GS a)2 core 10 sqmm PVC/A cable [PWD SOR, Page F-4/7 ( a ), F-5/8 ( b/iii ) ] |
| 51 | Laying of 2 core 16 Sqmm PVC/A Cable incl. 1 x 10 SWG G.I. Earth continuity conductor on wall by S/F MS saddles, making holes etc. as necy. Mending good damages and painting. [PWD SOR, Page F-1/2(a)] |
| 52 | Laying of 2 core 16 Sqmm PVC/A armoured cable incl. 1 x 10 SWG G.I. Earth continuity conductor recessed in wall & mending good the damages to original finish:- [PWD SOR, Page F-3/5(i)] |
| 53 | Fixing only Single/twin LED light fittings complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastner. [PWD SOR, Page C-2/14(b) |
| 54 | Earthing the the Installation by 50 mm dia G.I. Pipe (ISI -M) 3.64 mtr long & 1x4 SWG G.I.(Hot dip) wire (4 mtr long) with suitable nuts, bolts & washer etc. Incl S/F 15 mm dia GI protection pipe (1 mtr long) to be filled with bitumen partly under ground level & partly under ground level driven to an depth of 3.65 mtr below the ground level. [PWD SOR, Page G-1/2(a) |
| 55 | Supply & fixing earth busbar of galvanised (Hot dip) MS flat 25mm x 6mm on wall having clearance of 6mm from wall Incl providing drilled holes onthe busbar complete with nuts, bolts & washers spacing insulator etc. as required [PWD SOR, Page G-2/4(a) |
| 56 | S & drawing different size copper wire partly in polythine pipe embedded in wall & partly in rigid conduit pipe on wall for different power plug & A.C. points etc. a ) 2x6sq mm & 1x4 sq mm (for meter loop connection.. [PWD SOR, Page E-9/19, E-16/7(a)] |
| 57 | Fixing only Single/twin LED light fittings suspended 25 cm below the ceiling with 2 nos 20 mm dia EI conduit (14 SWG) supports fixed with \\"L\\"type MS clamp whose one side fixed on ceiling with suitable size 4nos fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, \\"L\\"type (125mm x 125 mm) 6mm thick and 25 mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5 sqmm) flexible copper wire of 1.10 mt. length. [PWD SOR, Page C-2/17] |
| 58 | Supply & Fixing of perforated GI cable tray with perforation notmore than 17.5% suspended from ceiling incl. S&F GI connector,6mm dia MS suspender, bolts & nuts, steel fastener etc. Incl. Al painting of MS support.(ii) With 25x25x3mm angle iron support 200x50x1.25mm (18SWG) [PWD SOR, Page D-14/34-a(ii)] |
| 59 | Electrical Works (Non-Schedule Work) Supply & Delivery of 4' 20W single LED Tube light fittings with mounting rail (make Crompton Cat. No -CCS-100-20-65-HL2-DP-NWH / philips/ Panasonic). |
| 60 | Supply & Delivery 4' 40 W LED batten tube light ( Make Philips CAT No. BN170C LED40S-6500 PSU L120 or equivalent product by Legero/Panasonic) |
| 61 | Supply & delivery of 1.1 Kv grade XLPE Aluminium armoured cable (make Gloster/KEI/Havells) a) 3.5 x 95 sq mm |
| 62 | Supply & delivery of 1.1 Kv grade XLPE Aluminium armoured cable(make Gloster/KEI/Havells) a) 3.5 x 35 sq mm |
| 63 | Supply & delivery of 1.1 Kv grade XLPE Aluminium armoured cable(make Gloster/KEI/Havells) a) 2 x 16 sq mm |
| 64 | Supply & Delivery of 1.1 kv grade XLPE Aluminium armared cable ( make Gloster/Havells/KEI) a) 2 x 10 sq. mm |
| 65 | Supply & fixing Metering panel of 19mm 3/4\\" inch water proof ply wood (Green ply) & 5mm Hylam sheet of size (8'ft x 4'ft) fixed on frabricated angle/flat iron frame on wall, comprising of the following switches & necy. wiring arrangement. a) 230V 40A D. pole MCB in suitable SS enclo.(Legrand) earthing attachment (Qr-20 nos, Commmon service - 1) -----21 nosb) Earth continuity wire by 2x4 sq mm(FR) PVC insulated single core stranded copper wire from earth bus bar to MCB eclosure by link clip on ply board --------- 63 mtr. The above board, MCB boxes & energy meters etc. are to be guarded with 12 SWG GI box type wire mesh on suitable angle iron structural frame having hinged doors with mechanical locking arrangement incl S/F pad lock & keys as per direction of the EIC. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender