Water Resources and Irrigation Government Departments Closing in 19 days TDR #58642327

Tender For Remodeling Of Kanwari Minor From Rd 0 To 26200

Issued by Government Departments · Bhiwani, Haryana
Tender Value
4.68 Crore
Estimated cost
Bid Submission
10 Dec 2026
19 days left
EMD
9.36 Lakhs
Bank guarantee accepted
Document Fee
15000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bhiwani → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Remodeling Of Kanwari Minor From Rd 0 To 26200

BOQ

Name of Work:- Remodeling of Kanwari Minor from RD 0 to 26200
Sl. No. Item Description
1NS Item -credit of old brick
2NS Item -Supply and fixing installation transportation painting and commisioning of gate and gearing rate approved by CE YWS (N) PKL Letter No. 226/5YWS/2191/2014 Date 14.01.2016
3NS Item -Recovery of Brick Bats @ 880/- per Cum as per already sanctioned estimate from chief engineer/YWS (NORTH), Vide letter no. 1139/4YC dated 16/03/2022 for Estimate of major repair of pump house no. 2 of Siwani canal on item no. 38.
4NS Item -Recovery of old steel @ 30/- per KG as per already sanctioned estimate from chief engineer/YWS (NORTH), Vide letter no. 1139/4YC dated 16/03/2022 for Estimate of major repair of pump house no. 2 of Siwani canal on item no. 39.
5NS Item -Recovery of Brick Bats @ 880/- per Cum as per already sanctioned estimate from chief engineer/YWS (NORTH), Vide letter no. 1139/4YC dated 16/03/2022 for Estimate of major repair of pump house no. 2 of Siwani canal on item no. 38.
6NS Item -Recovery of Brick Bats @ 880/- per Cum as per already sanctioned estimate from chief engineer/YWS (NORTH), Vide letter no. 1139/4YC dated 16/03/2022 for Estimate of major repair of pump house no. 2 of Siwani canal on item no. 38.
7NS Item -Recovery of old steel @ 30/- per KG as per already sanctioned estimate from chief engineer/YWS (NORTH), Vide letter no. 1139/4YC dated 16/03/2022 for Estimate of major repair of pump house no. 2 of Siwani canal on item no. 39.
8NS Item -Recovery of Brick Bats @ 880/- per Cum as per already sanctioned estimate from chief engineer/YWS (NORTH), Vide letter no. 1139/4YC dated 16/03/2022 for Estimate of major repair of pump house no. 2 of Siwani canal on item no. 38.
9NS Item -Recovery of old steel @ 30/- per KG as per already sanctioned estimate from chief engineer/YWS (NORTH), Vide letter no. 1139/4YC dated 16/03/2022 for Estimate of major repair of pump house no. 2 of Siwani canal on item no. 39.
10NS Item -Recovery of Brick Bats @ 880/- per Cum as per already sanctioned estimate from chief engineer/YWS (NORTH), Vide letter no. 1139/4YC dated 16/03/2022 for Estimate of major repair of pump house no. 2 of Siwani canal on item no. 38.
11NS Item -Recovery of Brick Bats @ 880/- per Cum as per already sanctioned estimate from chief engineer/YWS (NORTH), Vide letter no. 1139/4YC dated 16/03/2022 for Estimate of major repair of pump house no. 2 of Siwani canal on item no. 38.
12NS Item -Recovery of old steel @ 30/- per KG as per already sanctioned estimate from chief engineer/YWS (NORTH), Vide letter no. 1139/4YC dated 16/03/2022 for Estimate of major repair of pump house no. 2 of Siwani canal on item no. 39.
13NS Item -Credit for Old 300 mm Dia RCC Pipe
14NS Item -Recovery of Brick Bats @ 880/- per Cum as per already sanctioned estimate from chief engineer/YWS (NORTH), Vide letter no. 1139/4YC dated 16/03/2022 for Estimate of major repair of pump house no. 2 of Siwani canal on item no. 38.
15NS Item -Credit for Old 300 mm Dia RCC Pipe
16NS Item -Recovery of Brick Bats @ 880/- per Cum as per already sanctioned estimate from chief engineer/YWS (NORTH), Vide letter no. 1139/4YC dated 16/03/2022 for Estimate of major repair of pump house no. 2 of Siwani canal on item no. 38.
17NS Item -Providing and Fixing Over Head Water Tank of 750 Ltr.
18HSR Item 14.68.1.2.1-Lining with design mix concrete of grade M-15 with minimum cement content 240kg/cum as per required thickness including I0 mm thick cement plaster 1:5, curing, form work, dressing and preparation of sub grade as per directions of Engineer-in-charge. 1.2.1. 75mm thickness In slope Manually with form work HSR Rate(Rs.) 346.00 Through Rate
19HSR Item 27.5-Plain/Re-inforced cement concrete in substructure complete as per drawing and MoRTandH specifications 1500,1700 and 2200. PCC Grade M15 (with concrete Mixer) Height up to 5m HSR Rate(Rs.) 3985.00 Through Rate
20HSR Item 14.18-Filling expansion joints, with special impervious hot pour, 12.5 mm wide. HSR Rate(Rs.) 1.00 Through Rate
21HSR Item 4.12.1-Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineerin-charge. 1. All kinds of soil HSR Rate(Rs.) 78.00 Through Rate
22HSR Item 4.32-Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR Rate(Rs.) 46.00 Through Rate
23HSR Item 5.7.4-Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 4. In cement mortar HSR Rate(Rs.) 585.00 Through Rate
24HSR Item 5.23.1-Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1. Nominal concrete 1:1.5:3 or richer mix (i/c equivalent design mix) HSR Rate(Rs.) 480.00 Through Rate
25HSR Item 14.71-Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km . HSR Rate(Rs.) 115.00 Through Rate
26HSR Item 27.11.1.2-RCC Grade M30 1.2. With Batching Plant, Transit Mixer and Concrete Pump HSR Rate(Rs.) 4943.00 Through Rate
27HSR Item 27.10.1.2-RCC Grade M25 1.2. With Batching Plant, Transit Mixer and Concrete Pump HSR Rate(Rs.) 4312.00 Through Rate
28HSR Item 6.33.6-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more HSR Rate(Rs.) 66.00 Through Rate
29HSR Item 27.51.3-Filler joint 3. Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement up to 20 mm, covered with sealant complete as per drawing and MoRT&H specifications. HSR Rate(Rs.) 132.00 Through Rate
30HSR Item 15.6.3-Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and Technical Specifications MORTandH clause 1300 3. Cement Mortar1:4 (1cement :4 sand) HSR Rate(Rs.) 3551.00 Through Rate
31HSR Item 11.5.3-12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 113.00 Through Rate
32HSR Item 11.96.1-Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1. New work (Two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR Rate(Rs.) 85.00 Through Rate
33HSR Item 27.44.2-Drainage Spouts complete as per drawing no. SD/205 and MoRTandH MoRTandH specification clause 2705 with 6 meter long GI 100 mm dia drainage GI light grade pipe (For Bridges) 2. For fixing in position HSR Rate(Rs.) 1593.00 Through Rate
34HSR Item 10.34-Providing and laying dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. HSR Rate(Rs.) 474.00 Through Rate
35HSR Item 4.32-Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR Rate(Rs.) 46.00 Through Rate
36HSR Item 34.32.1-Metal Beam Crash Barrier 1. Type - A, \\"W\\" : Metal Beam Crash Barrier Providing and erecting a \\"W\\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 HSR Rate(Rs.) 2875.00 Through Rate
37HSR Item 34.36-Solar RPM/ Stud Providing and installation of solar cat eye produced from an engineered polymer selected for superior impact resistance and weather-ability. The top of the solar stud should be transparent for solar charging and light output in active mode. The base of the body shall be yellow or neutral white as approved by Engineer In-charge. The marker shall incorporate a solar panel (comprising of solar cells) for converting solar energy into electricity, a storage device for storing the energy, LEDs for illumination and a design for providing 360 degree smooth illumination. The Solar stud shall be round in shape for providing illumination in all directions. The solar stud shall also have high reflective polycarbonate/ methyl methecrylate lenses for conspicuity in passive mode and dual shanks for improved road presence. The solar studs are intended for application directly onto pavement surfaces and shall be applied with epoxy resin adhesives designed for use with raised pavement markers and as supplied by the marker manufacturer separately. The solar cat eye shall be of height: 65 ± 2 mm & Maximum Diameter: 136 ± 5 mm. The body of the solar cat eye shall be resistant to dust and water ingress as per IP 65 standards. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280. HSR Rate(Rs.) 2583.00 Through Rate
38HSR Item 34.11.1-Informatory sign board 900x600 rectangular as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4 mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORTandH specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting and a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67-2012 1. Using retro reflective Sheeting Class C as per IRC 67 2012 HSR Rate(Rs.) 6666.00 Through Rate
39HSR Item 5.26-Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. HSR Rate(Rs.) 1971.00 Through Rate
40HSR Item 5.7.4-Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 4. In cement mortar HSR Rate(Rs.) 585.00 Through Rate
41HSR Item 5.23.1-Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1. Nominal concrete 1:1.5:3 or richer mix (i/c equivalent design mix) HSR Rate(Rs.) 480.00 Through Rate
42HSR Item 27.5-Plain/Re-inforced cement concrete in substructure complete as per drawing and MoRTandH specifications 1500,1700 and 2200. PCC Grade M15 (with concrete Mixer) Height up to 5m HSR Rate(Rs.) 3985.00 Through Rate
43HSR Item 17.15.2-Granular Sub-Base with Coarse Graded Material - Grading-I or II or III (Table:- 400-2) Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.of MORTandH specifications 2. Grading II material HSR Rate(Rs.) 1044.00 Through Rate
44HSR Item 4.12.1-Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineerin-charge. 1. All kinds of soil HSR Rate(Rs.) 78.00 Through Rate
45HSR Item 17.75-Demolishing dry brick on end edging pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within any lead. HSR Rate(Rs.) 121.00 Through Rate
46HSR Item 14.71-Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km . HSR Rate(Rs.) 115.00 Through Rate
47HSR Item 27.11.1.2-RCC Grade M30 1.2. With Batching Plant, Transit Mixer and Concrete Pump HSR Rate(Rs.) 4943.00 Through Rate
48HSR Item 27.10.1.2-RCC Grade M25 1.2. With Batching Plant, Transit Mixer and Concrete Pump HSR Rate(Rs.) 4312.00 Through Rate
49HSR Item 6.33.6-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more HSR Rate(Rs.) 66.00 Through Rate
50HSR Item 27.51.3-Filler joint 3. Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement up to 20 mm, covered with sealant complete as per drawing and MoRT&H specifications. HSR Rate(Rs.) 132.00 Through Rate
51HSR Item 15.6.3-Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and Technical Specifications MORTandH clause 1300 3. Cement Mortar1:4 (1cement :4 sand) HSR Rate(Rs.) 3551.00 Through Rate
52HSR Item 11.5.3-12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 113.00 Through Rate
53HSR Item 11.96.1-Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1. New work (Two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR Rate(Rs.) 85.00 Through Rate
54HSR Item 27.44.2-Drainage Spouts complete as per drawing no. SD/205 and MoRTandH MoRTandH specification clause 2705 with 6 meter long GI 100 mm dia drainage GI light grade pipe (For Bridges) 2. For fixing in position HSR Rate(Rs.) 1593.00 Through Rate
55HSR Item 10.34-Providing and laying dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. HSR Rate(Rs.) 474.00 Through Rate
56HSR Item 4.32-Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR Rate(Rs.) 46.00 Through Rate
57HSR Item 34.32.1-Metal Beam Crash Barrier 1. Type - A, \\"W\\" : Metal Beam Crash Barrier Providing and erecting a \\"W\\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 HSR Rate(Rs.) 2875.00 Through Rate
58HSR Item 34.36-Solar RPM/ Stud Providing and installation of solar cat eye produced from an engineered polymer selected for superior impact resistance and weather-ability. The top of the solar stud should be transparent for solar charging and light output in active mode. The base of the body shall be yellow or neutral white as approved by Engineer In-charge. The marker shall incorporate a solar panel (comprising of solar cells) for converting solar energy into electricity, a storage device for storing the energy, LEDs for illumination and a design for providing 360 degree smooth illumination. The Solar stud shall be round in shape for providing illumination in all directions. The solar stud shall also have high reflective polycarbonate/ methyl methecrylate lenses for conspicuity in passive mode and dual shanks for improved road presence. The solar studs are intended for application directly onto pavement surfaces and shall be applied with epoxy resin adhesives designed for use with raised pavement markers and as supplied by the marker manufacturer separately. The solar cat eye shall be of height: 65 ± 2 mm & Maximum Diameter: 136 ± 5 mm. The body of the solar cat eye shall be resistant to dust and water ingress as per IP 65 standards. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280. HSR Rate(Rs.) 2583.00 Through Rate
59HSR Item 34.6.1-Mandatory sign board 900 mm circular as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4 mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORTandH specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting and a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67-2012 1. Using retro reflective Sheeting Class C as per IRC 67 2012 HSR Rate(Rs.) 5791.00 Through Rate
60HSR Item 34.11.1-Informatory sign board 900x600 rectangular as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4 mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORTandH specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting and a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67-2012 1. Using retro reflective Sheeting Class C as per IRC 67 2012 HSR Rate(Rs.) 6666.00 Through Rate
61HSR Item 27.5-Plain/Re-inforced cement concrete in substructure complete as per drawing and MoRTandH specifications 1500,1700 and 2200. PCC Grade M15 (with concrete Mixer) Height up to 5m HSR Rate(Rs.) 3985.00 Through Rate
62HSR Item 17.15.2-Granular Sub-Base with Coarse Graded Material - Grading-I or II or III (Table:- 400-2) Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.of MORTandH specifications 2. Grading II material HSR Rate(Rs.) 1044.00 Through Rate
63HSR Item 4.12.1-Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineerin-charge. 1. All kinds of soil HSR Rate(Rs.) 78.00 Through Rate
64HSR Item 14.71-Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km . HSR Rate(Rs.) 115.00 Through Rate
65HSR Item 17.75-Demolishing dry brick on end edging pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within any lead. HSR Rate(Rs.) 121.00 Through Rate
66HSR Item 27.11.1.2-RCC Grade M30 1.2. With Batching Plant, Transit Mixer and Concrete Pump HSR Rate(Rs.) 4943.00 Through Rate
67HSR Item 27.10.1.2-RCC Grade M25 1.2. With Batching Plant, Transit Mixer and Concrete Pump HSR Rate(Rs.) 4312.00 Through Rate
68HSR Item 6.33.6-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more HSR Rate(Rs.) 66.00 Through Rate
69HSR Item 27.51.3-Filler joint 3. Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement up to 20 mm, covered with sealant complete as per drawing and MoRT&H specifications. HSR Rate(Rs.) 132.00 Through Rate
70HSR Item 15.6.3-Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and Technical Specifications MORTandH clause 1300 3. Cement Mortar1:4 (1cement :4 sand) HSR Rate(Rs.) 3551.00 Through Rate
71HSR Item 11.5.3-12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 113.00 Through Rate
72HSR Item 11.96.1-Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1. New work (Two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR Rate(Rs.) 85.00 Through Rate
73HSR Item 27.44.2-Drainage Spouts complete as per drawing no. SD/205 and MoRTandH MoRTandH specification clause 2705 with 6 meter long GI 100 mm dia drainage GI light grade pipe (For Bridges) 2. For fixing in position HSR Rate(Rs.) 1593.00 Through Rate
74HSR Item 10.34-Providing and laying dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. HSR Rate(Rs.) 474.00 Through Rate
75HSR Item 4.32-Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR Rate(Rs.) 46.00 Through Rate
76HSR Item 34.32.1-Metal Beam Crash Barrier 1. Type - A, \\"W\\" : Metal Beam Crash Barrier Providing and erecting a \\"W\\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 HSR Rate(Rs.) 2875.00 Through Rate
77HSR Item 34.36-Solar RPM/ Stud Providing and installation of solar cat eye produced from an engineered polymer selected for superior impact resistance and weather-ability. The top of the solar stud should be transparent for solar charging and light output in active mode. The base of the body shall be yellow or neutral white as approved by Engineer In-charge. The marker shall incorporate a solar panel (comprising of solar cells) for converting solar energy into electricity, a storage device for storing the energy, LEDs for illumination and a design for providing 360 degree smooth illumination. The Solar stud shall be round in shape for providing illumination in all directions. The solar stud shall also have high reflective polycarbonate/ methyl methecrylate lenses for conspicuity in passive mode and dual shanks for improved road presence. The solar studs are intended for application directly onto pavement surfaces and shall be applied with epoxy resin adhesives designed for use with raised pavement markers and as supplied by the marker manufacturer separately. The solar cat eye shall be of height: 65 ± 2 mm & Maximum Diameter: 136 ± 5 mm. The body of the solar cat eye shall be resistant to dust and water ingress as per IP 65 standards. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280. HSR Rate(Rs.) 2583.00 Through Rate
78HSR Item 34.11.1-Informatory sign board 900x600 rectangular as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4 mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORTandH specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting and a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67-2012 1. Using retro reflective Sheeting Class C as per IRC 67 2012 HSR Rate(Rs.) 6666.00 Through Rate
79HSR Item 27.5-Plain/Re-inforced cement concrete in substructure complete as per drawing and MoRTandH specifications 1500,1700 and 2200. PCC Grade M15 (with concrete Mixer) Height up to 5m HSR Rate(Rs.) 3985.00 Through Rate
80HSR Item 17.15.2-Granular Sub-Base with Coarse Graded Material - Grading-I or II or III (Table:- 400-2) Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.of MORTandH specifications 2. Grading II material HSR Rate(Rs.) 1044.00 Through Rate
81HSR Item 17.75-Demolishing dry brick on end edging pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within any lead. HSR Rate(Rs.) 121.00 Through Rate
82HSR Item 14.71-Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km . HSR Rate(Rs.) 115.00 Through Rate
83HSR Item 4.12.1-Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineerin-charge. 1. All kinds of soil HSR Rate(Rs.) 78.00 Through Rate
84HSR Item 27.11.1.2-RCC Grade M30 1.2. With Batching Plant, Transit Mixer and Concrete Pump HSR Rate(Rs.) 4943.00 Through Rate
85HSR Item 27.10.1.2-RCC Grade M25 1.2. With Batching Plant, Transit Mixer and Concrete Pump HSR Rate(Rs.) 4312.00 Through Rate
86HSR Item 6.33.6-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more HSR Rate(Rs.) 66.00 Through Rate
87HSR Item 27.51.3-Filler joint 3. Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement up to 20 mm, covered with sealant complete as per drawing and MoRT&H specifications. HSR Rate(Rs.) 132.00 Through Rate
88HSR Item 15.6.3-Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and Technical Specifications MORTandH clause 1300 3. Cement Mortar1:4 (1cement :4 sand) HSR Rate(Rs.) 3551.00 Through Rate
89HSR Item 11.5.3-12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 113.00 Through Rate
90HSR Item 11.96.1-Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1. New work (Two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR Rate(Rs.) 85.00 Through Rate
91HSR Item 27.44.2-Drainage Spouts complete as per drawing no. SD/205 and MoRTandH MoRTandH specification clause 2705 with 6 meter long GI 100 mm dia drainage GI light grade pipe (For Bridges) 2. For fixing in position HSR Rate(Rs.) 1593.00 Through Rate
92HSR Item 10.34-Providing and laying dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. HSR Rate(Rs.) 474.00 Through Rate
93HSR Item 4.32-Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR Rate(Rs.) 46.00 Through Rate
94HSR Item 34.32.1-Metal Beam Crash Barrier 1. Type - A, \\"W\\" : Metal Beam Crash Barrier Providing and erecting a \\"W\\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 HSR Rate(Rs.) 2875.00 Through Rate
95HSR Item 34.36-Solar RPM/ Stud Providing and installation of solar cat eye produced from an engineered polymer selected for superior impact resistance and weather-ability. The top of the solar stud should be transparent for solar charging and light output in active mode. The base of the body shall be yellow or neutral white as approved by Engineer In-charge. The marker shall incorporate a solar panel (comprising of solar cells) for converting solar energy into electricity, a storage device for storing the energy, LEDs for illumination and a design for providing 360 degree smooth illumination. The Solar stud shall be round in shape for providing illumination in all directions. The solar stud shall also have high reflective polycarbonate/ methyl methecrylate lenses for conspicuity in passive mode and dual shanks for improved road presence. The solar studs are intended for application directly onto pavement surfaces and shall be applied with epoxy resin adhesives designed for use with raised pavement markers and as supplied by the marker manufacturer separately. The solar cat eye shall be of height: 65 ± 2 mm & Maximum Diameter: 136 ± 5 mm. The body of the solar cat eye shall be resistant to dust and water ingress as per IP 65 standards. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280. HSR Rate(Rs.) 2583.00 Through Rate
96HSR Item 34.6.1-Mandatory sign board 900 mm circular as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4 mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORTandH specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting and a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67-2012 1. Using retro reflective Sheeting Class C as per IRC 67 2012 HSR Rate(Rs.) 5791.00 Through Rate
97HSR Item 34.11.1-Informatory sign board 900x600 rectangular as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4 mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORTandH specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting and a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67-2012 1. Using retro reflective Sheeting Class C as per IRC 67 2012 HSR Rate(Rs.) 6666.00 Through Rate
98HSR Item 5.26-Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. HSR Rate(Rs.) 1971.00 Through Rate
99HSR Item 5.7.4-Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 4. In cement mortar HSR Rate(Rs.) 585.00 Through Rate
100HSR Item 5.23.1-Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1. Nominal concrete 1:1.5:3 or richer mix (i/c equivalent design mix) HSR Rate(Rs.) 480.00 Through Rate
101HSR Item 27.5-Plain/Re-inforced cement concrete in substructure complete as per drawing and MoRTandH specifications 1500,1700 and 2200. PCC Grade M15 (with concrete Mixer) Height up to 5m HSR Rate(Rs.) 3985.00 Through Rate
102HSR Item 17.15.2-Granular Sub-Base with Coarse Graded Material - Grading-I or II or III (Table:- 400-2) Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.of MORTandH specifications 2. Grading II material HSR Rate(Rs.) 1044.00 Through Rate
103HSR Item 4.12.1-Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineerin-charge. 1. All kinds of soil HSR Rate(Rs.) 78.00 Through Rate
104HSR Item 14.71-Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km . HSR Rate(Rs.) 115.00 Through Rate
105HSR Item 5.6-Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : HSR Rate(Rs.) 266.00 Through Rate
106HSR Item 27.11.1.2-RCC Grade M30 1.2. With Batching Plant, Transit Mixer and Concrete Pump HSR Rate(Rs.) 4943.00 Through Rate
107HSR Item 27.10.1.2-RCC Grade M25 1.2. With Batching Plant, Transit Mixer and Concrete Pump HSR Rate(Rs.) 4312.00 Through Rate
108HSR Item 6.33.6-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more HSR Rate(Rs.) 66.00 Through Rate
109HSR Item 27.51.3-Filler joint 3. Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement up to 20 mm, covered with sealant complete as per drawing and MoRT&H specifications. HSR Rate(Rs.) 132.00 Through Rate
110HSR Item 11.5.3-12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 113.00 Through Rate
111HSR Item 11.96.1-Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1. New work (Two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR Rate(Rs.) 85.00 Through Rate
112HSR Item 27.44.2-Drainage Spouts complete as per drawing no. SD/205 and MoRTandH MoRTandH specification clause 2705 with 6 meter long GI 100 mm dia drainage GI light grade pipe (For Bridges) 2. For fixing in position HSR Rate(Rs.) 1593.00 Through Rate
113HSR Item 10.34-Providing and laying dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. HSR Rate(Rs.) 474.00 Through Rate
114HSR Item 4.32-Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR Rate(Rs.) 46.00 Through Rate
115HSR Item 34.32.1-Metal Beam Crash Barrier 1. Type - A, \\"W\\" : Metal Beam Crash Barrier Providing and erecting a \\"W\\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 HSR Rate(Rs.) 2875.00 Through Rate
116HSR Item 34.36-Solar RPM/ Stud Providing and installation of solar cat eye produced from an engineered polymer selected for superior impact resistance and weather-ability. The top of the solar stud should be transparent for solar charging and light output in active mode. The base of the body shall be yellow or neutral white as approved by Engineer In-charge. The marker shall incorporate a solar panel (comprising of solar cells) for converting solar energy into electricity, a storage device for storing the energy, LEDs for illumination and a design for providing 360 degree smooth illumination. The Solar stud shall be round in shape for providing illumination in all directions. The solar stud shall also have high reflective polycarbonate/ methyl methecrylate lenses for conspicuity in passive mode and dual shanks for improved road presence. The solar studs are intended for application directly onto pavement surfaces and shall be applied with epoxy resin adhesives designed for use with raised pavement markers and as supplied by the marker manufacturer separately. The solar cat eye shall be of height: 65 ± 2 mm & Maximum Diameter: 136 ± 5 mm. The body of the solar cat eye shall be resistant to dust and water ingress as per IP 65 standards. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280. HSR Rate(Rs.) 2583.00 Through Rate
117HSR Item 34.11.1-Informatory sign board 900x600 rectangular as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4 mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORTandH specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting and a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67-2012 1. Using retro reflective Sheeting Class C as per IRC 67 2012 HSR Rate(Rs.) 6666.00 Through Rate
118HSR Item 5.26-Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. HSR Rate(Rs.) 1971.00 Through Rate
119HSR Item 5.7.4-Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 4. In cement mortar HSR Rate(Rs.) 585.00 Through Rate
120HSR Item 5.23.1-Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1. Nominal concrete 1:1.5:3 or richer mix (i/c equivalent design mix) HSR Rate(Rs.) 480.00 Through Rate
121HSR Item 27.5-Plain/Re-inforced cement concrete in substructure complete as per drawing and MoRTandH specifications 1500,1700 and 2200. PCC Grade M15 (with concrete Mixer) Height up to 5m HSR Rate(Rs.) 3985.00 Through Rate
122HSR Item 17.15.2-Granular Sub-Base with Coarse Graded Material - Grading-I or II or III (Table:- 400-2) Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.of MORTandH specifications 2. Grading II material HSR Rate(Rs.) 1044.00 Through Rate
123HSR Item 17.75-Demolishing dry brick on end edging pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within any lead. HSR Rate(Rs.) 121.00 Through Rate
124HSR Item 14.71-Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km . HSR Rate(Rs.) 115.00 Through Rate
125HSR Item 4.12.1-Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineerin-charge. 1. All kinds of soil HSR Rate(Rs.) 78.00 Through Rate
126HSR Item 27.11.1.2-RCC Grade M30 1.2. With Batching Plant, Transit Mixer and Concrete Pump HSR Rate(Rs.) 4943.00 Through Rate
127HSR Item 27.10.1.2-RCC Grade M25 1.2. With Batching Plant, Transit Mixer and Concrete Pump HSR Rate(Rs.) 4312.00 Through Rate
128HSR Item 6.33.6-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more HSR Rate(Rs.) 66.00 Through Rate
129HSR Item 27.51.3-Filler joint 3. Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement up to 20 mm, covered with sealant complete as per drawing and MoRT&H specifications. HSR Rate(Rs.) 132.00 Through Rate
130HSR Item 15.6.3-Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and Technical Specifications MORTandH clause 1300 3. Cement Mortar1:4 (1cement :4 sand) HSR Rate(Rs.) 3551.00 Through Rate
131HSR Item 11.5.3-12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 113.00 Through Rate
132HSR Item 11.96.1-Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1. New work (Two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR Rate(Rs.) 85.00 Through Rate
133HSR Item 27.44.2-Drainage Spouts complete as per drawing no. SD/205 and MoRTandH MoRTandH specification clause 2705 with 6 meter long GI 100 mm dia drainage GI light grade pipe (For Bridges) 2. For fixing in position HSR Rate(Rs.) 1593.00 Through Rate
134HSR Item 10.34-Providing and laying dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. HSR Rate(Rs.) 474.00 Through Rate
135HSR Item 4.32-Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR Rate(Rs.) 46.00 Through Rate
136HSR Item 34.32.1-Metal Beam Crash Barrier 1. Type - A, \\"W\\" : Metal Beam Crash Barrier Providing and erecting a \\"W\\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 HSR Rate(Rs.) 2875.00 Through Rate
137HSR Item 34.36-Solar RPM/ Stud Providing and installation of solar cat eye produced from an engineered polymer selected for superior impact resistance and weather-ability. The top of the solar stud should be transparent for solar charging and light output in active mode. The base of the body shall be yellow or neutral white as approved by Engineer In-charge. The marker shall incorporate a solar panel (comprising of solar cells) for converting solar energy into electricity, a storage device for storing the energy, LEDs for illumination and a design for providing 360 degree smooth illumination. The Solar stud shall be round in shape for providing illumination in all directions. The solar stud shall also have high reflective polycarbonate/ methyl methecrylate lenses for conspicuity in passive mode and dual shanks for improved road presence. The solar studs are intended for application directly onto pavement surfaces and shall be applied with epoxy resin adhesives designed for use with raised pavement markers and as supplied by the marker manufacturer separately. The solar cat eye shall be of height: 65 ± 2 mm & Maximum Diameter: 136 ± 5 mm. The body of the solar cat eye shall be resistant to dust and water ingress as per IP 65 standards. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280. HSR Rate(Rs.) 2583.00 Through Rate
138HSR Item 34.6.1-Mandatory sign board 900 mm circular as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4 mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORTandH specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting and a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67-2012 1. Using retro reflective Sheeting Class C as per IRC 67 2012 HSR Rate(Rs.) 5791.00 Through Rate
139HSR Item 34.11.1-Informatory sign board 900x600 rectangular as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4 mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORTandH specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting and a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67-2012 1. Using retro reflective Sheeting Class C as per IRC 67 2012 HSR Rate(Rs.) 6666.00 Through Rate
140HSR Item 5.26-Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. HSR Rate(Rs.) 1971.00 Through Rate
141HSR Item 5.7.4-Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 4. In cement mortar HSR Rate(Rs.) 585.00 Through Rate
142HSR Item 5.23.1-Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1. Nominal concrete 1:1.5:3 or richer mix (i/c equivalent design mix) HSR Rate(Rs.) 480.00 Through Rate
143HSR Item 27.5-Plain/Re-inforced cement concrete in substructure complete as per drawing and MoRTandH specifications 1500,1700 and 2200. PCC Grade M15 (with concrete Mixer) Height up to 5m HSR Rate(Rs.) 3985.00 Through Rate
144HSR Item 17.15.2-Granular Sub-Base with Coarse Graded Material - Grading-I or II or III (Table:- 400-2) Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.of MORTandH specifications 2. Grading II material HSR Rate(Rs.) 1044.00 Through Rate
145HSR Item 4.12.1-Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineerin-charge. 1. All kinds of soil HSR Rate(Rs.) 78.00 Through Rate
146HSR Item 14.71-Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km . HSR Rate(Rs.) 115.00 Through Rate
147HSR Item 17.75-Demolishing dry brick on end edging pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within any lead. HSR Rate(Rs.) 121.00 Through Rate
148HSR Item 27.11.1.2-RCC Grade M30 1.2. With Batching Plant, Transit Mixer and Concrete Pump HSR Rate(Rs.) 4943.00 Through Rate
149HSR Item 27.10.1.2-RCC Grade M25 1.2. With Batching Plant, Transit Mixer and Concrete Pump HSR Rate(Rs.) 4312.00 Through Rate
150HSR Item 6.33.6-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more HSR Rate(Rs.) 66.00 Through Rate
151HSR Item 27.51.3-Filler joint 3. Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement up to 20 mm, covered with sealant complete as per drawing and MoRT&H specifications. HSR Rate(Rs.) 132.00 Through Rate
152HSR Item 15.6.3-Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and Technical Specifications MORTandH clause 1300 3. Cement Mortar1:4 (1cement :4 sand) HSR Rate(Rs.) 3551.00 Through Rate
153HSR Item 11.5.3-12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 113.00 Through Rate
154HSR Item 11.96.1-Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1. New work (Two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR Rate(Rs.) 85.00 Through Rate
155HSR Item 27.44.2-Drainage Spouts complete as per drawing no. SD/205 and MoRTandH MoRTandH specification clause 2705 with 6 meter long GI 100 mm dia drainage GI light grade pipe (For Bridges) 2. For fixing in position HSR Rate(Rs.) 1593.00 Through Rate
156HSR Item 4.32-Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR Rate(Rs.) 46.00 Through Rate
157HSR Item 34.32.1-Metal Beam Crash Barrier 1. Type - A, \\"W\\" : Metal Beam Crash Barrier Providing and erecting a \\"W\\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 HSR Rate(Rs.) 2875.00 Through Rate
158HSR Item 34.36-Solar RPM/ Stud Providing and installation of solar cat eye produced from an engineered polymer selected for superior impact resistance and weather-ability. The top of the solar stud should be transparent for solar charging and light output in active mode. The base of the body shall be yellow or neutral white as approved by Engineer In-charge. The marker shall incorporate a solar panel (comprising of solar cells) for converting solar energy into electricity, a storage device for storing the energy, LEDs for illumination and a design for providing 360 degree smooth illumination. The Solar stud shall be round in shape for providing illumination in all directions. The solar stud shall also have high reflective polycarbonate/ methyl methecrylate lenses for conspicuity in passive mode and dual shanks for improved road presence. The solar studs are intended for application directly onto pavement surfaces and shall be applied with epoxy resin adhesives designed for use with raised pavement markers and as supplied by the marker manufacturer separately. The solar cat eye shall be of height: 65 ± 2 mm & Maximum Diameter: 136 ± 5 mm. The body of the solar cat eye shall be resistant to dust and water ingress as per IP 65 standards. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280. HSR Rate(Rs.) 2583.00 Through Rate
159HSR Item 34.11.1-Informatory sign board 900x600 rectangular as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4 mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORTandH specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting and a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67-2012 1. Using retro reflective Sheeting Class C as per IRC 67 2012 HSR Rate(Rs.) 6666.00 Through Rate
160HSR Item 5.53.1-Removing hume pipes-NP 2/NP 3/NP 4 including excavation and taking out the pipes manually/ by mechanical means and stacking the pipes within standard lead as per direction of Engineer-in-charge 1. up to 600 mm dia HSR Rate(Rs.) 85.00 Through Rate
161HSR Item 5.7.4-Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 4. In cement mortar HSR Rate(Rs.) 585.00 Through Rate
162HSR Item 27.5-Plain/Re-inforced cement concrete in substructure complete as per drawing and MoRTandH specifications 1500,1700 and 2200. PCC Grade M15 (with concrete Mixer) Height up to 5m HSR Rate(Rs.) 3985.00 Through Rate
163HSR Item 17.15.2-Granular Sub-Base with Coarse Graded Material - Grading-I or II or III (Table:- 400-2) Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.of MORTandH specifications 2. Grading II material HSR Rate(Rs.) 1044.00 Through Rate
164HSR Item 4.12.1-Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineerin-charge. 1. All kinds of soil HSR Rate(Rs.) 78.00 Through Rate
165HSR Item 14.71-Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km . HSR Rate(Rs.) 115.00 Through Rate
166HSR Item 10.34-Providing and laying dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. HSR Rate(Rs.) 474.00 Through Rate
167HSR Item 17.75-Demolishing dry brick on end edging pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within any lead. HSR Rate(Rs.) 121.00 Through Rate
168HSR Item 21.95.10-Providing lowering cutting jointing and testing RCC pipe class NP3 as per IS-458-2003 with spigot and socketed joints manufactured with ISI marked sulphate resistance cement as per ISI 12330 with rubber rings ISI marked antiternmite as required at site in to trenches for all depths and laying out the same to correct alignment gradients and levels including dressing and trimming and cutting of concrete beds and side of trenches, if required jointing with rubber rings in trenches and jointing with 1:3/2 cement sand mortar and with end dowels filled with 1:3/2 cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socket joints cutting and finishing the cut surface to a uniform finish etc. as fully described in item No. 21.38, item 21.44, item 21.45, and item 21.46 including cartage loading and unloading complete in all respects. the internal diametric of the sewer being: 10. 1200 mm HSR Rate(Rs.) 6204.00 Through Rate
169HSR Item 27.10.1.2-RCC Grade M25 1.2. With Batching Plant, Transit Mixer and Concrete Pump HSR Rate(Rs.) 4312.00 Through Rate
170HSR Item 6.33.6-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more HSR Rate(Rs.) 66.00 Through Rate
171HSR Item 20.85.4-Supplying and Fixing of PVC water bars for water stops flexible physical plastic for preventing leakage in concrete joints to avoid seepage ( Fixo- stop) with ribs and central bulbs marked as per IS-12200 of 2001 along with bitumen filler complete in all respects. 4. 300 mm x 8 mm thickness of wall HSR Rate(Rs.) 501.00 Through Rate
172HSR Item 28.12-`Providing and applying waterproofing treatment to sound, moisture free concrete surface using liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks up to 2 mm. It shall be applied in two coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. The membrane formed shall confirm to following minimum properties: 1) Elongation : )400% as per ASTM D 412 2) Tensile Strength : 2.5 N/mm2 as per ASTM D 412 3) Adhesion in-peel test : )50 N as per ASTM C- 836 4) Recovery from 350% elongation : 95% as per ASTM D 412 5) Water Vapour Transmission 2.3mm film: 0.6 g/m2/hr 6) Initial Hardness Shore A : min 60 as per ASTM D 2240 7) Root resistant : protection screed required System includes supply , application and termination of coating all complete as per the manufacturer methodology. Clean the RCC slab/screed surface and wall for treatment by removing dust, dirt and layers of concrete over the surface. etc. by mechanical tools and wire brushing. Pressure grouting at construction joints or honeycombs with non shrink cementations grout by mixing shrinkage compensating admixture per bag of cement as per manufacturer’s recommendations. Providing and applying liquid applied single component pitch free polyurethane coating in 2 coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. (Fibre cloth/fleece/reinforcement should not be used in between two coats of PU as it has adverse effect on elongation property and also affects bonding with slab). Termination shall be done 300 mm above vertical wall by providing a groove cut of 30mm x 30mm and seal it with shrinkage compensated polymer modified mortar. Membrane shall be protected using 8mm thick dimple board for protection as per manufacturer`s recommendation followed by backfilling. The rates are inclusive of surface preparation, crack filling, injection grouting at honeycombed areas, coving, priming all complete as per manufacturer methodology but excluding the cost of protection board. ` HSR Rate(Rs.) 719.00 Through Rate
173HSR Item 11.96.1-Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1. New work (Two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR Rate(Rs.) 85.00 Through Rate
174HSR Item 21.28-Providing and fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, rehandling etc., complete in all respect to the satisfaction of Engineer-in-charge HSR Rate(Rs.) 298.00 Through Rate
175HSR Item 34.36-Solar RPM/ Stud Providing and installation of solar cat eye produced from an engineered polymer selected for superior impact resistance and weather-ability. The top of the solar stud should be transparent for solar charging and light output in active mode. The base of the body shall be yellow or neutral white as approved by Engineer In-charge. The marker shall incorporate a solar panel (comprising of solar cells) for converting solar energy into electricity, a storage device for storing the energy, LEDs for illumination and a design for providing 360 degree smooth illumination. The Solar stud shall be round in shape for providing illumination in all directions. The solar stud shall also have high reflective polycarbonate/ methyl methecrylate lenses for conspicuity in passive mode and dual shanks for improved road presence. The solar studs are intended for application directly onto pavement surfaces and shall be applied with epoxy resin adhesives designed for use with raised pavement markers and as supplied by the marker manufacturer separately. The solar cat eye shall be of height: 65 ± 2 mm & Maximum Diameter: 136 ± 5 mm. The body of the solar cat eye shall be resistant to dust and water ingress as per IP 65 standards. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280. HSR Rate(Rs.) 2583.00 Through Rate
176HSR Item 34.6.1-Mandatory sign board 900 mm circular as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4 mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORTandH specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting and a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67-2012 1. Using retro reflective Sheeting Class C as per IRC 67 2012 HSR Rate(Rs.) 5791.00 Through Rate
177HSR Item 5.53.1-Removing hume pipes-NP 2/NP 3/NP 4 including excavation and taking out the pipes manually/ by mechanical means and stacking the pipes within standard lead as per direction of Engineer-in-charge 1. up to 600 mm dia HSR Rate(Rs.) 85.00 Through Rate
178HSR Item 5.7.4-Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 4. In cement mortar HSR Rate(Rs.) 585.00 Through Rate
179HSR Item 27.5-Plain/Re-inforced cement concrete in substructure complete as per drawing and MoRTandH specifications 1500,1700 and 2200. PCC Grade M15 (with concrete Mixer) Height up to 5m HSR Rate(Rs.) 3985.00 Through Rate
180HSR Item 17.15.2-Granular Sub-Base with Coarse Graded Material - Grading-I or II or III (Table:- 400-2) Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.of MORTandH specifications 2. Grading II material HSR Rate(Rs.) 1044.00 Through Rate
181HSR Item 4.12.1-Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineerin-charge. 1. All kinds of soil HSR Rate(Rs.) 78.00 Through Rate
182HSR Item 2.RM079- RM079. Earth Cost or compensation for earth taken from private land HSR Rate(Rs.) 18.00 Rate
183HSR Item 27.5-Plain/Re-inforced cement concrete in substructure complete as per drawing and MoRTandH specifications 1500,1700 and 2200. PCC Grade M15 (with concrete Mixer) Height up to 5m HSR Rate(Rs.) 3985.00 Through Rate
184HSR Item 15.6.3-Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and Technical Specifications MORTandH clause 1300 3. Cement Mortar1:4 (1cement :4 sand) HSR Rate(Rs.) 3551.00 Through Rate
185HSR Item 2.B1546- B1546. S&S Centrifugally (Spun) C.I. Pipe class LA 150 mm dia HSR Rate(Rs.) 919.00 Rate
186HSR Item 11.5.3-12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 113.00 Through Rate
187HSR Item 11.3-Neat cement punning. HSR Rate(Rs.) 29.00 Through Rate
188HSR Item 4.12.1-Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineerin-charge. 1. All kinds of soil HSR Rate(Rs.) 78.00 Through Rate
189HSR Item 27.5-Plain/Re-inforced cement concrete in substructure complete as per drawing and MoRTandH specifications 1500,1700 and 2200. PCC Grade M15 (with concrete Mixer) Height up to 5m HSR Rate(Rs.) 3985.00 Through Rate
190HSR Item 15.6.3-Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and Technical Specifications MORTandH clause 1300 3. Cement Mortar1:4 (1cement :4 sand) HSR Rate(Rs.) 3551.00 Through Rate
191HSR Item 2.B1546- B1546. S&S Centrifugally (Spun) C.I. Pipe class LA 150 mm dia HSR Rate(Rs.) 919.00 Rate
192HSR Item 11.5.3-12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 113.00 Through Rate
193HSR Item 11.3-Neat cement punning. HSR Rate(Rs.) 29.00 Through Rate
194HSR Item 4.12.1-Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineerin-charge. 1. All kinds of soil HSR Rate(Rs.) 78.00 Through Rate
195HSR Item 27.5-Plain/Re-inforced cement concrete in substructure complete as per drawing and MoRTandH specifications 1500,1700 and 2200. PCC Grade M15 (with concrete Mixer) Height up to 5m HSR Rate(Rs.) 3985.00 Through Rate
196HSR Item 15.6.3-Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and Technical Specifications MORTandH clause 1300 3. Cement Mortar1:4 (1cement :4 sand) HSR Rate(Rs.) 3551.00 Through Rate
197HSR Item 11.5.3-12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 113.00 Through Rate
198HSR Item 4.12.1-Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineerin-charge. 1. All kinds of soil HSR Rate(Rs.) 78.00 Through Rate
199HSR Item 27.5-Plain/Re-inforced cement concrete in substructure complete as per drawing and MoRTandH specifications 1500,1700 and 2200. PCC Grade M15 (with concrete Mixer) Height up to 5m HSR Rate(Rs.) 3985.00 Through Rate
200HSR Item 27.10.1.2-RCC Grade M25 1.2. With Batching Plant, Transit Mixer and Concrete Pump HSR Rate(Rs.) 4312.00 Through Rate
201HSR Item 21.24-Brick ballast, well or over burnt broken and screened through a 32mm x 32mm square mesh screen laid consolidated and rammed to a finished thickness of 75mm as above. HSR Rate(Rs.) 732.00 Through Rate
202HSR Item 15.6.3-Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and Technical Specifications MORTandH clause 1300 3. Cement Mortar1:4 (1cement :4 sand) HSR Rate(Rs.) 3551.00 Through Rate
203HSR Item 13.21.1-Supply and fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm and Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets and screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge. 1. Door Frame of size 80mm x 50mm with 37mm wide single rebate for 35mm door shutter HSR Rate(Rs.) 947.00 Through Rate
204HSR Item 13.6.2-Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 2. Using flats 30x6mm for diagonal braces and central cross piece HSR Rate(Rs.) 2598.00 Through Rate
205HSR Item 12.132.1-Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape and size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware`s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing and direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 1. Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area up to 0.75 sqm) HSR Rate(Rs.) 4933.00 Through Rate
206HSR Item 6.33.6-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more HSR Rate(Rs.) 66.00 Through Rate
207HSR Item 9.10.1-Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 1. With residual type petroleum bitumen of grade VG -10 HSR Rate(Rs.) 93.00 Through Rate
208HSR Item 9.14.1-Providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: 1. With common burnt clay non-modular brick tiles of class designation 10 HSR Rate(Rs.) 374.00 Through Rate
209HSR Item 9.17.1-Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase HSR Rate(Rs.) 112.00 Through Rate
210HSR Item 9.18-Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. HSR Rate(Rs.) 147.00 Through Rate
211HSR Item 9.57.2-Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter HSR Rate(Rs.) 200.00 Through Rate
212HSR Item 11.5.3-12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 113.00 Through Rate
213HSR Item 11.20-18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge. HSR Rate(Rs.) 177.00 Through Rate
214HSR Item 11.17-Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-incharge HSR Rate(Rs.) 234.00 Through Rate
215HSR Item 6.13.A-Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling and dressing and finishing the top smooth. A. Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 6 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling & dressing & finishing the top smooth. HSR Rate(Rs.) 286.81 Rate
216HSR Item 11.57-Providing and laying average 6mm thick POP Coating on walls, Ceiling, beams and lintels etc. complete in all respects as approved by the Engineer-In-Charge. HSR Rate(Rs.) 68.00 Through Rate
217HSR Item 11.58-Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete HSR Rate(Rs.) 32.00 Through Rate
218HSR Item 11.96.1-Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 1. New work (Two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) HSR Rate(Rs.) 85.00 Through Rate
219HSR Item 10.69.2-Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 2. Size of Tile 600x600 mm HSR Rate(Rs.) 1081.00 Through Rate
220HSR Item 22.22.1-Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1. White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests HSR Rate(Rs.) 3493.00 Through Rate
221HSR Item 22.171.1-Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. 1. With common burnt clay non-modular bricks of class designation 7.5 HSR Rate(Rs.) 11422.00 Through Rate
222HSR Item 22.86.2-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes HSR Rate(Rs.) 264.00 Through Rate
223HSR Item 22.106.1-Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1. 15 mm nominal bore HSR Rate(Rs.) 457.00 Through Rate
224HSR Item 22.1.1-Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 1. White vitreous chinaware Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps HSR Rate(Rs.) 2027.00 Through Rate
225HSR Item 22.20.2-Providing and fixing in position C.I. plain Nahani Trap conforming to I.S.I. specifications and of self cleaning design with C.P. brass hinged grating with frame complete 2. With 75 mm internal diameter outlet HSR Rate(Rs.) 1170.00 Through Rate
226HSR Item 22.81.2-Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 2. 75 mm dia HSR Rate(Rs.) 147.00 Through Rate
227HSR Item 22.129.2-Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 2. 20 mm nominal bore, weighing not less than 40 gms HSR Rate(Rs.) 65.00 Through Rate
228HSR Item 22.112.2-Providing and fixing PTMT stop cock of approved quality and colour. 2. 20 mm nominal bore, 89 mm long, weighing not less than 88 gms HSR Rate(Rs.) 119.00 Through Rate
229HSR Item 22.124.2-Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 2. 20 mm nominal bore, 120 mm long, weighing not less than 198 gms HSR Rate(Rs.) 178.00 Through Rate
230HSR Item 23.4.1.2-COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.2. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B HSR Rate(Rs.) 572.00 Through Rate
231HSR Item 23.4.4.2-COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.2. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B HSR Rate(Rs.) 830.00 Through Rate
232HSR Item 23.1.6.2-COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.2. Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) HSR Rate(Rs.) 163.00 Through Rate
233HSR Item 23.8.11.1-FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch HSR Rate(Rs.) 41.00 Through Rate
234HSR Item 23.8.11.3-FITTING AND ACCESSORIES 11.3. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch HSR Rate(Rs.) 82.00 Through Rate
235HSR Item 23.8.11.4-FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket HSR Rate(Rs.) 82.00 Through Rate
236HSR Item 23.8.11.5-FITTING AND ACCESSORIES 11.5. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket HSR Rate(Rs.) 124.00 Through Rate
237HSR Item 23.8.11.7-FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt HSR Rate(Rs.) 257.00 Through Rate
238HSR Item 23.22.1.1-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.1. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-incharge of the work. Double pole MCCB 16 to 63 Amp, 25 Ka HSR Rate(Rs.) 1452.00 Through Rate
239HSR Item 4.12.1-Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineerin-charge. 1. All kinds of soil HSR Rate(Rs.) 78.00 Through Rate
240HSR Item 14.71-Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km . HSR Rate(Rs.) 115.00 Through Rate Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58642327
AUTHORITY Government Departments
TENDER VALUE 4.68 Crore
LAST DATE 10-12-2026
Authority
Authority Name Irrigation Department
Work Description Tender for Remodeling Of Kanwari Minor From Rd 0 To 26200
Basic Detail
Tender No 202647B23AAF 4377 43C7 8DFC 16DE3F29ACF1129IRR
Bidding Type Tender
Location
City Bhiwani
State Haryana
Key Dates
Publish Date 20 Nov 2026
Submission Date 10 Dec 2026
Open Date 10 Dec 2026
Finance
Tender Value 4.68 Crore
Tender Fee 15000
EMD 9.36 Lakhs
Exemption Available
Document List
AD0185239.pdf
bb268b40-5ddd-4f59-8b3c-579d86a0c1e1.html
BOQ_641877.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Dec 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
pdf

AD0185239.pdf

html

bb268b40-5ddd-4f59-8b3c-579d86a0c1e1.html

xls

BOQ_641877.xls

pdf

Tendernotice_1.pdf

Disclaimer