Tender For Repair To Certain E/M Items At Siyot Under Ge (A) Bhuj.
Tender Overview
Project Description
Tender For Repair To Certain E/M Items At Siyot Under Ge (A) Bhuj.1Old U/S copper recd from item no 2 and 8 and 302Old U/S bearing recd from item no 3 and 93Old U/S item recd from 10 to 144Old U/S item recd from 20 to 235Old U/S item GI Pipe6Old U/S item Ball valve any type7Old U/S twin core cable8Old U/S fuel filter/air filter9Old U/S main contactor10Old U/S battery charger11Old U/S battery12Old U/S copper Material received from item No 53 & 5413Old U/S Material received from item No 55 to 5714Old U/S Material received from item No 59 to 6115Old U/S Material received from item No 65 to 6816Old U/S Material received from item No 70,77,8317Old U/S Material received from item No 75.10 to 75.4018Old U/S Material received from item No 77.10 to 77.4019Old U/S Material received from item No 8120Old U/S Material received from item No 87 to 9021Old U/S Material received from item No 8022Old U/S Material received from item No 7823Old U/S Material received from item No 76.10 to 76.4024Old unserviceable point wiring complete.25Old unserviceable Piano flush button, bell push, ceiling rose, fan regulator, swich socket outlets, 5/15 Amp Angular holder.26Old unserviceable tube light fittings/ bulk head fittings.27Old unserviceable MCB DBs.28Old unserviceable SP and TPN SPNS29Old unserviceable submain wiring30Old unserviceable earthing31Old U/s MCCB of any capcity32Old U/S Earthing any type complete.33Old U/S LT cable34Old U/S LED street light35Old U/S junction box36Old U/S service cable
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of defective centrifugal pump set/open well pump set, of any make/Model for repairing and reassembling including replacement of defective spare parts by new one of capacity of 5 HP pump set including required MS stud with nuts and bolts etc all as required. Note: (i) Spare parts of the centrifugal pump sets shall be measured and paid separately under relavent item of schedule. (ii) The rates for above items are deemed to include transportation of pumps/ motors to and from workshop with replacement of oil seal, sand guard, bolt gusket, cable packing ring, water seal, bearing bush upper & lower etc as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at authorised workshop. |
| 2 | M & L rewinding of induction motor after taking out all burnt ,U/s copper winding wire, cleaning and finishing of the casing and slots properly for rewinding the motors with existing SWG super enameled copper wire including varnishing ,baking ,testing including complete all as specified and directed at site etc. of capacity 5 HP Motor. |
| 3 | Supply only suitable size bearing for induction motor of 5 HP, after taking out old unservicable complete all as specified and directed at site etc. |
| 4 | Supply and fix in repairs RO Membranes Brakish Water Spiral (CPA3) type, capacity upto 3000 LPH, pressure 12 Kg/Sqcm, MOC Cellulose Polyamide, of Filteration grade 97-98% Salt Rejection of Size 8040 complete with pressure vessels, RO membrane connectors etc complete all as specified and directed. Make : Toray/LG/ Hydranautics |
| 5 | S&F in repair Bag filter 4\\" x 20\\", type multimedia filter, filtration grade - 5 micron, flow rate not less than 3000 Ltrs / Hr, complete as directed of make Aqualux / Ion exchange / Aqua. |
| 6 | Supply and fix in repairs Cartridge Filter Online wound type of size 2.5\\" Dia x 20\\" long, Pressure 3.5 - 4.0Kg/Sqcm, MOC : PP, Filteration Grade 20 Microns, capacity 2.0m3/hr complete all as specified and directed |
| 7 | Dismantling of defective centrifugal pump set of RO plant , of any make/Model for repairing and reassembling including replacement of defective spare parts by new one of capacity of 1/1.5/2 HP pump set including required MS stud with nuts and bolts etc all as required. Note: (i) Spare parts of the centrifugal pump sets shall be measured and paid separately under relavent item of schedule. (ii) The rates for above items are deemed to include transportation of pumps/ motors to and from workshop with replacement of oil seal, sand guard, bolt gusket, cable packing ring, water seal, bearing bush upper & lower etc as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at authorised workshop. |
| 8 | M & L rewinding of induction motor after taking out all burnt ,U/s copper winding wire, cleaning and finishing of the casing and slots properly for rewinding the motors with existing SWG super enameled copper wire including varnishing ,baking ,testing including complete all as specified and directed at site etc. of capacity 1/1.5 HP Motor. |
| 9 | M & L rewinding of induction motor after taking out all burnt ,U/s copper winding wire, cleaning and finishing of the casing and slots properly for rewinding the motors with existing SWG super enameled copper wire including varnishing ,baking ,testing including complete all as specified and directed at site etc. of capacity 2HP Motor. |
| 10 | Supply only suitable size bearing for induction motor of 1/1.5/2 HP , after taking out old unservicable complete all as specified and directed at site etc. |
| 11 | Disconnecting and taking down old PVC tubing and connections of any description/ grade and in any position in trenches/under floors / on walls etc including all fittings/accessories and fixtures such as bends, union, elbow socket, valves, taps etc, all as directed and specified for 20 mm dia pipe complete all as specified and directed. |
| 12 | All as per item No. 11 here in above but 25 mm dia pipe complete all as specified and directed |
| 13 | All as per item No. 11 here in above but 40 mm dia pipe complete all as specified and directed |
| 14 | All as per item No. 11 here in above but 50 mm dia pipe complete all as specified and directed |
| 15 | All as per item No. 11 here in above but 80 mm dia pipe complete all as specified and directed |
| 16 | Supply and Fixing in any length UPVC pipe 20 mm dia pipe manufactured as per ASTM-D-1785 as per IS-559, Schedule-40 complete with fittings, laid in trenches in required length complete all as specified and directed |
| 17 | All as per item No. 16 here in above but size (25 mm dia) complete all as specified and directed |
| 18 | All as per item No. 16 here in above but size (40 mm dia) complete all as specified and directed |
| 19 | All as per item No. 16 here in above but size (50 mm dia)complete all as specified and directed |
| 20 | All as per item No. 16 here in above but size (80 mm dia) complete all as specified and directed |
| 21 | S & F in repair UPVC Ball valves with operating handle (stop valve) of size 20 mm dia complete suitable for fittings with ASTM - 1785, Schedule 40 UPVC pipes complete all as specified and directed. |
| 22 | All as per item No. 21 here in above but of size (25 mm dia) complete all as specified and directed. |
| 23 | All as per item No. 21 here in above but of size (50 mm dia)complete all as specified and directed |
| 24 | All as per item No. 21 here in above but of size (80 mm dia) complete all as specified and directed |
| 25 | Excavation in trenches in soft / loose soil nexc 1.5 mtr wide and not exc 1.5 m in depth etc complete and getting out in soft soil inciuding trimming sides and bottom of trenches complete all as specified and directed. |
| 26 | Retuning filling in trenches including watering and well ramming in layer not exc 25 cm thick in soft/ loose soil complete all as specified and directed. |
| 27 | Removing excavated surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed |
| 28 | Testing of water for physical bacteriogical analyisi as per standared/IS cod test from any govt approved recognized lab or NABL approved lab or approved by the GE sample should be collected by Ref of lab. Please Enable Macros to View BoQ information |
| 29 | Testing of water for physical bacteriogical analyisi as per standared/IS cod test from any govt approved recognized lab or NABL approved lab or approved by the GE sample should be collected by Ref of lab. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender