Tender For Maintenance Of Electrical Installation In Non Residential Building At Chandigarh (Replacement Of Defective Electrical Accessories In Various Buildings I.E. Sports Complex, Pggcg, Dispensaries, Sampark Centre, Library Etc. In Sector-42, Cha
Tender Overview
Project Description
Tender for Maintenance Of Electrical Installation In Non Residential Building At Chandigarh (Replacement Of Defective Electrical Accessories In Various Buildings I.E. Sports Complex, Pggcg, Dispensaries, Sampark Centre, Library Etc. In Sector-42, Chandigarh Under The Jurisdiction Of Sde, E-2, Chandigarh).
BOQ
| Sl. No. | Item Description |
| 1 | DSR item No. 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | DSR item No. 1.17 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 4 | 3 x 1.5 sq. mm |
| 5 | 3 x 2.5 sq. mm |
| 6 | DSR item No. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 7 | 25 mm |
| 8 | DSR item No. 1.23 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 9 | 5/6 amps switch |
| 10 | 15/16 A switch |
| 11 | 3 pin 5/6 A socket outlet |
| 12 | 6 pin 15/16 A socket outlet |
| 13 | DSR item No. 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 14 | 5/6 A switch |
| 15 | 15/16 A switch |
| 16 | 3 pin 5/6 A socket outlet |
| 17 | 6 pin 15/16 A socket outlet |
| 18 | DSR item No. 1.28 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 19 | 3 Module |
| 20 | 6 Module |
| 21 | 12 Module |
| 22 | DSR item No. 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 23 | 100 A,30KA,FPMCCB |
| 24 | 250 A,36KA,FPMCCB |
| 25 | DSR item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 26 | Single pole |
| 27 | Triple pole |
| 28 | Triple pole and neutral |
| 29 | DSR item No. 8.1 LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt )(Please refer DNIT for complete specification of item no.09) |
| 30 | 18 watt |
| 31 | DSR item No. 8.7 LED Panel light 2x2 ft.(System lumen efficacy ≥120 <135 lm/Watt) (Recess/ Surface type)(Please refer DNIT for complete specification of item no.10) |
| 32 | 36 watt |
| 33 | DSR item No. 8.9 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).(Please refer DNIT for complete specification of item no.11) |
| 34 | 24-26 watt |
| 35 | DSR item No. 8.13 LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) (Please refer DNIT for complete specification of item no.12) |
| 36 | 72 watt |
| 37 | DSR item No. 8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt).(Please refer DNIT for complete specification of item no.13) |
| 38 | 100 watt |
| 39 | S/E of 3mm thick white glazed Bakelite sheet on the existing M.S box. The job includes the cost of sheets and making holes and cutting charges of switches & sockets. The job includes the cost of all labour & petty material required to complete the job. The Bakelite sheet should be of Superhylam/ Greenlam/ Formica make only. |
| 40 | Supply and laying of XLPE insulated PVC sheathed Aluminum conductor armoured cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing Trench/RCC/ HUME/ METAL/ DWC pipe / on surface with the help of MS clamp suitable size as required at site. The job includes labour charges of laying the cable and making connections with suitable size aluminium lugs/thimbles etc as required at site to complete the job to the entire satisfaction of Engineer-in-Charge. The cable should be of Havells/ Polycab/ RR Kabel/ KEI/ Finolex make only. |
| 41 | Size 10 sq. mm 4 Core (On Surface) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender