Tender For Renovation Of Dome Structure For Jigyasa Lab At Csir-Serc, Csir Campus, Taramani, Chennai - 600 113
Tender Value
14.30 Lakhs
Estimated cost
Bid Submission
02 Dec 2026
10 days left
EMD
28601
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of Dome Structure For Jigyasa Lab At Csir-Serc, Csir Campus, Taramani, Chennai - 600 113
BOQ
| Sl. No. | Item Description |
| 1 | PART - A (CIVIL): Surface dressing of the ground including removing vegetation and in equalities not exceeding 15 cm deep and disposal of rubbish within CSIR-SERC Campus etc., all as per instruction of Engineer -incharge. |
| 2 | All kinds of soil |
| 3 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 4 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 5 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in |
| 6 | Cement mortar 1:4 (1 cement :4 coarse sand |
| 7 | 12 mm cement plaster of mix : |
| 8 | 1:4 (1 cement: 4 coarse sand) |
| 9 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish etc.,, complete all as per the direction of Engineer-In-Charge. |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 11 | 8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 12 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 13 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level |
| 14 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 16 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 17 | Supplying and filling in plinth with Quarry dust under floors, including watering, ramming, consolidating and dressing etc., complete all as per the instruction of Engineer-incharge. |
| 18 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 19 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 20 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). etc. complete all as per direction of Engineer- incharge. (Make - Johnson, Somany, Kajaria or equvalent) |
| 21 | Size of Tile 600x600 mm |
| 22 | Providing and fixing 1st quality ceramic anti skid floor tiles 600x600 mm of joint free tile conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green,black of any size as approved by Engineer-in-Charge in Staircase skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.(Make - Johnson, Somany, Kajaria or equvalent)) |
| 23 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and coloure:(The rate is inclusive of necessary scrapping and putty wherever is required). |
| 24 | Two or more coats on old and new work |
| 25 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade |
| 26 | New / Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface including water thinnable priming coat with cement primer for new work (The rate is inclusive of necessary touch up Exterior wall care putty and scrapping wherever is required. (Make : Asian, Berger or equvalent) |
| 27 | Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. |
| 28 | Old work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gm/litre :(The rate is inclusive of necessary scrapping and putty wherever is required). (Make : Asian, Berger or equvalent) |
| 29 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 30 | Polished Granite stone slab jet Black, Cherry Red, Lakshmi red, Elite Brown, Cat Eye or equivalent. |
| 31 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 32 | Providing and fixing Polyvinyl Chloride (PVC) pipes, having thermal stability for hot & cold water supply, including all PVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work/ Exposed on wall, including cutting chases and making good the walls etc. (Finolex or equvalent make) |
| 33 | 175mm pvc pipe (6Kg/Sqcm) |
| 34 | 110mm pvc pipe (6Kg/Sqcm) |
| 35 | PART - B (ELECTRICAL): Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 36 | Group B |
| 37 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit with suitable MS clamps to be fixed on the hallow square section purlinas required. |
| 38 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 39 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 40 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 41 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 42 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 43 | a) 5/6 amps switch |
| 44 | b) 15/16 amp switch |
| 45 | c) 3 pin 5/6 amp socket outlet |
| 46 | d) 6 pin 15/16 amp socket outlet |
| 47 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 48 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 49 | a) 4 Module (125mmX75mm) |
| 50 | b) 6 Module (200mmX75mm) |
| 51 | c) 12 Module (200mmX150mm) |
| 52 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board/VTPN DB'S including drilling holes in cubicle panel, making connections, etc. as required. |
| 53 | 100 A,30KA,FP MCCB |
| 54 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 55 | b) 16 way, Double door |
| 56 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 57 | a) 8 way (4 + 24), Double door |
| 58 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 59 | a) Single pole 32A |
| 60 | b) Double pole 32A |
| 61 | c) Triple pole 32A |
| 62 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, SP, MCB, in sheet steel enclosure, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 63 | LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 64 | 40 watt (2 X 20 W) |
| 65 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conducto single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).including |
| 66 | 72 watt |
| 67 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 68 | Above 35 sq. mm and upto 95 sq. mm |
| 69 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 70 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 71 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 72 | 3½ X 70 sq. mm (38mm) |
| 73 | Supply of 3.5C x 70 SQ mm XLPE insulated PVC sheathed, armoured Aluminium conductor, U.G cable of 1.1 kV grade confirming to IS 1554.Part-I. Make:Havells,polycab,Finolex |
| 74 | Supply, Installation, testing and commissioning of Pedestal fan with metal body 450 mm,1500 RPM including overload protection with autostast, pull card machanism for ON & OFF Speedcontrol and also unique oscillation machanismas per site condictions, connections, testing and commissioning etc..,as required |
| 75 | Removing and refixing of Tubelight fitting, Switch boards,DB'S on wall surface including refixing and rewiring and reconnections of existing wiring with suitable wiring materials and accessories complete as required. including removing and rerouting of existing PVC insulated UG cable with necessary clamps including making necessary hole on the wall and terminating at existing 4 pole end closer with reglanding work etc.. complete as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysDec 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender