Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #58641055

Tender For Repair/Cleaning Of Septic Tank, Soakage Well And Other Allied Work In Domestic And Tech Area At Mil Stn Dappar Under Age(I) Dappar.

Issued by Statutory Bodies & Commissions/Committees · S.a.s Nagar, Punjab
Tender Value
Ref. Documents
Estimated cost
Bid Submission
12 Dec 2026
21 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
S.a.s Nagar → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Cleaning Of Septic Tank, Soakage Well And Other Allied Work In Domestic And Tech Area At Mil Stn Dappar Under Age(I) Dappar.

BOQ

Name of Work:- REPAIR/CLEANING OF SEPTIC TANK, SOAKAGE WELL AND OTHER ALLIED WORK IN DOMESTIC AND TECH AREA AT MIL STN DAPPAR UNDER AGE(I) DAPPAR.
Sl. No. Item Description
1Cleaning of sewage lines including manholes of 150mm bore by means of cleaning rods through manholes to manholes, taking out sludge collected in manholes, depositing the same in the pit at a minimum distance of 50m from nearby living accn and covering the sludge in pit with earth and finally spraying unslaked lime, dry, around the manholes and over the pit, complete all as specified and directed by Engr-In-Charge.
2Cleaning of sewage lines including manholes of 200mm bore by means of cleaning rods through manholes to manholes, taking out sludge collected in manholes, depositing the same in the pit at a minimum distance of 50m from nearby living accn and covering the sludge in pit with earth and finally spraying unslaked lime, dry, around the manholes and over the pit, complete all as specified and directed by Engr-In-Charge.
3De-watering of septic tanks and soakage wells by with sewage pump air tight body hired by contractor and draining out the same out of cantt area complete all as directed and to the entire satisfaction of Engr-in-Charge.Note :- (a) Cost of excavation and earth work for pits for burrying the waste/sludge etc shall deemed to be included in the unit rate.(b) Any damage caused during cleaning shall be rectified to satisfaction of Engr-in-Charge by the contractor without any extra cost.
4Taking out sludge from septic tanks including inlet and outlet chambers, removing and depositing the sludge in a pit at out of MOD Land by means of moter pump covering the sludge in the pit with earth and finally spraying unslaked lime, dry, around the septic tank and over the pit, complete all as specified and directed by Engr-In-Charge.Note :- (a) Cost of excavation and earth work for pits for burrying the waste/sludge etc shall deemed to be included in the unit rate.(b) Any damage caused during cleaning shall be rectified to satisfaction of Engr-in-Charge by the contractor without any extra cost.
5Cleaning of blocked Bottle trap, WC-'P' trap/ 'S' trap, Nahani trap, Kitchen-Gully trap etc upto 1st manhole and making the drain pipe of any size full functional by flushing with water to entire satisfaction of Engr-in-Charge.Note :- (a) Cost of excavation and earth work for pits for burrying the waste/sludge etc shall deemed to be included in the unit rate.(b) Any damage caused during cleaning shall be rectified to satisfaction of Engr-in-Charge by the contractor without any extra cost.
6Excavating over areas, not exc 1.5m deep and getting soft/soose soil, complete all as specifed and directed.
7Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and directed.
8All as per ser item No-7.00 here- in- before but depth exc 1.5 m but not exc 3.00 m complete all as specifed and directed.
9Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm. in soft/loose soil in excavated pit or trenches, complete all as specifed and directed.
10Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed.
11Demolition of 150mm bore SGSW drain pipes including PCC haunching and bedding jointed in cement mortar and including removal, complete all as specified and directed.
12Demolition of 200 mm bore SGSW drain pipes including PCC haunching and bedding jointed in cement mortar and including removal, complete all as specified and directed.
13Demolition of 300 mm bore SGSW drain pipes including PCC haunching and bedding jointed in cement mortar and including removal, complete all as specified and directed.
14Material and labour Salt- glazed stoneware drain pipe grade ‘A’ 150mm internal diameter of pipe, ISI marked jointed with cement mortar, laid in trenches and jointed and tested, complete all as specified and directed.
15Supply and fix for providing, lowering and laying HDPE DWCPE (SN8) pipes as per IS : 16098 of 2013, 200mm bore, laid and jointed with and including elastomeric sealing 'O' ring as per manufacturer's instructions, complete all as specified and directed.Note - The rates include for laying pipes level or to falls in trenches, etc. on concrete bed or directly on hard ground as indicated and making joints and testing as specified.The rates include for all necessary extra joints, waste, and cutting etc.
16Supply and fix for providing, lowering and laying HDPE DWCPE (SN8) pipes as per IS : 16098 of 2013, 300m bore, laid and jointed with and including elastomeric sealing 'O' ring as per manufacturer's instructions including dismantling complete all as specified and directed. Note - The rates include for laying pipes level or to falls in trenches, etc. on concrete bed or directly on hard ground as indicated and making joints and testing as specified.The rates include for all necessary extra joints, waste, and cutting etc.
17Material and labour PCC type C-2, 1:3:6 using 40mm graded stone aggregate as in concrete bed to drain pipe including packing under & haunching against sides of pipes after the pipe are laid and tested for 150mm, complete all as specified and directed.
18Material and labour PCC type C-2, 1:3:6 using 40mm graded stone aggregate as in concrete bed to drain pipe including packing under & haunching against sides of pipes after the pipe are laid and tested for 200mm complete all as specified and directed.
19Material and labour PCC type C-2, 1:3:6 using 40mm graded stone aggregate as in concrete bed to drain pipe including packing under & haunching against sides of pipes after the pipes are laid and tested for 300mm complete all as specified and directed.
20Cutting into existing manhole for connecting new drain, making good to pipes and rendering cutting out existing benching for and forming branch channel (½ round of ¾ section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for 150/200 mm bore pipe complete all as specified and directed.
21Demolition of stone or brick masonry built in cement mortar including all quoins, arches etc. but excluding ashlar facing, dressed stone work etc, complete all as specified and directed.
22Material and labour for brick work with fly ash bricks, old size, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar 1:6, complete all as specified and directed by Engineer-in-Charge.
23Material and labour brick work with sub class 'B' burnt bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 but except brick complete all as specified and directed by Engr-in-Charge.Note-serviceble Old bricks shall be reused after cleaning obtained from demolition.
24Material and labour for rendering 15mm thick on brick /concrete surfces in CM 1:4 finished even & smooth without using extra cement, complete all as specified and directed.
25Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position including removing rubbish material from building and thrown in low lying empty area from the site, complete all as specified and as directed by Engineer-in-Charge
26Material and labour for 100mm thick PCC type B-2 (1:2:4) 40mm graded aggregate finished surface even and smooth without using extra cement including necessary form work, complete all as specified and directed.
27Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for (Reinforcement cut as required to facilitate demolition), complete all as specified and directed.
28Material and labour for mild steel TMT bars 6 to 8mm dia & over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.(NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
29Material and labour for Providing, precast cement concrete (1:2:4) Type B1 (20 mm graded aggregate) set in CM (1:6) in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, complete all as specified and directed.
30Material and labour for PCC (1:4:8) type D-2, (using 40mm graded stone aggregate) as in foundation, filling and mass concreting complete all as specified and directed.
31Material and labour for PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate) in surface channel and drain/manhole etc, complete all as specified and directed.
32Material and labour for PCC (1:2:4) type B-0, (using 12.5mm graded stone aggregate) as in benching, kerb, bed plates, coping, drains including necessary formwork etc., complete all as specified and directed.
33Supply and fix 100mm bore cast iron soil waste and vent pipe, sand cast pipes in any length with or without ears jointed with cement mortar (1:3) laid in trenches or in floors or on wall fixed in repair including taking down existing pipes, complete all as specified and directed.
34Supply and fix 75mm bore cast iron soil waste and vent pipe, sand cast pipes in any length with or without ears jointed with cement mortar (1:3) laid in trenches or in floors or on wall fixed in repair including taking down existing pipes, complete all as specified and directed.
35Supply and fix in repair 100mm cast iron bends, complete all as specified and directed.
36Supply and fix in repair 75mm cast iron bends, complete all as specified and directed.
37Supply and fix stack clamps out of 50mmx5mm flat iron and 16mm dia round iron stays including bolts & nuts and securing ends of stay to wall for 100mm bore CI pipes, complete all as specified and directed.
38Supply and fix stack clamps out of 50mmx5mm flat iron and 16mm dia round iron stays including bolts & nuts and securing ends of stay to wall for 75mm bore CI pipes, complete all as specified and directed.
39Taking down rain water pipes/PVC pipes/cemented pipe (any size or pattern) including all fittings, heads, shoes, bends, swan necks, etc.,at any height, any location, any floor including all necessary scaffolding, complete all as specified and as directed by Engineer-in-Charge.
40Supply and fix 110mm dia PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed in wall including GI clamps of approved shape and size approved by AGE(I) at any height, any location, any floor including necessary scaffolding, complete all as specified and as directed by Engineer-in-Charge.
41Supply and fix 110mm dia PVC (SWR) bends/shoes any radius fixed to pipe at any location/height including necessary scaffolding etc, complete all as specified and as directed by Engineer-in-Charge.
42Supply and fix 75mm dia PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed in wall including GI clamps of approved shape and size approved by AGE(I) at any height including necessary scaffolding, complete all as specified and as directed by Engineer-in-Charge.
43Supply and fix 75mm dia PVC (SWR) bends/shoes any radius fixed to pipe at any location/height including necessary scaffolding etc, complete all as specified and as directed by Engineer-in-Charge.
44Supply and fix in repairs for Vitreous china squatting pan, Orissa pattern, size 580 x 440 mm white, with integral foot rests ( excluding flushing cistern and flush pipe) including 'P' or 'S' trap fixed, complete all as specified and directed.
45Supply and fix in repairs for Vitreous china wash down water closet pan, pedestal pattern, white, fixed in repairs complete including connecting to existing cistern including 'P' or 'S' trap fixed, complete all as specified and directed.
46Supply and fix in repairs for plastic water closet seat white closed pattern with flat bottom and cover and mild steel chromium plated hinging device any type (as per site requirement any type any size), ISI marked fixed, complete all as specified and directed.
47Supply and fix in repairs for PVC connection 15mm dia and 45cm long with 2 Nos PTMT nuts, fixed, complete all as specified and directed.
48Supply and fix in repairs for PVC connection 15mm dia and 60 cm long with 2 Nos PTMT nuts, complete all as specified and directed.
49Supply and fix repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall hook incliding making connection and fixed in position, complete in all as specified and as directed.
50Supply and fix in repair grating doom 125mm dia with waste hole of PTMT (Min wt 40g) complete in all as specified and as directed.
51Supply and fix in repairs for vitreous china Urinal, half stall type white standard size (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing urinal spreader of PTMT any colour, grating and Union for discharge pipe, complete all as specified and directed.
52Supply and fix in repairs for urinal spreader of PTMT any colour for fixing with 15mm dia pipe (min weight 60gms) complete all as specified and directed.
53Supply and fix in repairs for PVC valveless, syphonic action type, flushing cistern 10 litres capacity, low level, white, with inlet ball valve , float and handle inlcuding brackets, complete all as specified and directed.
54Supply and fix in repairs for PVC flush pipe/Bend (long bend/short) for low level PVC cistern 40mm bore etc, complete all as specifed and directed.
55Supply and fix in repair Vitreous China premium/1st quality wash down water closet wall hung EWC white/ivory/off whte (Closed patern including all necessary accessories like rag bolts/ gel gasket etcpan (pedestal pattern), white (exluding fixing bolts, flushing cistern and flush pipe) including white seat cover fixed with mild steel chromium plated hinging devices, flushing jet spray & CI P or S trap, complete all as specified and directed.
56Supply and fix factory made precast RCC manhole cover slab with and including frame designation LD 2.5, clear opening of frame size (1.00m x 1.00m x 0.075m/1.20m x 0.60m x 0.075m) thick ISI marked (IS-12592:2002) (As approved by GE/AGE(I)) complete all as specified and directed.
57Material and labour for Glazed coloured ceramic tiles External/Internal in vertical surfaces 300mm x 450mmx7mm thick over & including 10mm thick rendering in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling and removing the debris outside the defence land, complete all as specified and directed.
58Material and labour for Non-skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm over & including 15mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes, set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling and removing the debris outside the defence land, complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58641055
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 12-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Cleaning Of Septic Tank, Soakage Well And Other Allied Work In Domestic And Tech Area At Mil Stn Dappar Under Age(I) Dappar.
Basic Detail
Tender No CA No AGE(I)/DPR/T-19/2026-27
Bidding Type Tender
Location
City S.a.s Nagar
State Punjab
Key Dates
Publish Date 20 Nov 2026
Submission Date 12 Dec 2026
Open Date 14 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 40000
Exemption Available
Document List
aa518ea4-7c07-45cd-bcc5-106b4e4846f9.html
BOQ_897270.xls
Tendernotice_1.pdf
Tendert19.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Dec 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

aa518ea4-7c07-45cd-bcc5-106b4e4846f9.html

xls

BOQ_897270.xls

pdf

Tendernotice_1.pdf

pdf

Tendert19.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender