Tender For Repair / Maintenance Of Ht Transformer, Ht Cable God, 2 Pole, 4 Pole Structures, Ligntening Arrestors At Chsc, 4 Rmc Qtrs, Alc Qtrs, Eme Qtrs Under Age E/M-Ii Of Ge (South) Pune.
Tender Value
35 Lakhs
Estimated cost
Bid Submission
14 Dec 2026
22 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance Of Ht Transformer, Ht Cable God, 2 Pole, 4 Pole Structures, Ligntening Arrestors At Chsc, 4 Rmc Qtrs, Alc Qtrs, Eme Qtrs Under Age E/M-Ii Of Ge (South) Pune.
BOQ
| Sl. No. | Item Description |
| 1 | M&L for dismantling of HT unserviceable steel poles of any size including taking out of embedded portion of poles from concrete after necessary demolition of concrete foundation and disposal of the same all as specified and directed. |
| 2 | M&L for dismantling cross-arms of MS channel or angle sections etc. complete and setting aside for re-use and removing unserviceable /rusted crossarms and accessories from Site, complete all as specified and directed. |
| 3 | M&L for dismantling air break gang operated swtches vertical/ horizontal mounted including insulators and operating mechanism for repair/replacement of broken/worn out components and insulators etc.and keeping serviceable gang operated switches in safe custody for re-use and removing unserviceable gang operated switch from Site, complete all as specified and as directed. |
| 4 | M & L for dismantling of HT Lightning Arresters of any type/rating with all fittings complete all as specified and directed. |
| 5 | Supply, erecting & fixing Steel tubular swaged pole, 11.0 metres long complete with cast iron base plate, finial taper plug,bolts, nuts and screws as specifed type 410 SP-55 complete all as specified & directed.[Note: Excavation & earthwork, cement concrete, etc. will be measured and paid separately under relevant Items of this Schedule] |
| 6 | S & F Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including two coats of aluminium paint over a coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified & as directed. |
| 7 | Fixing only serviceable Cross arms, bracings, supports, clamps and back plates etc. as obtained from srl item No 02 here-in-before including two coats of aluminium paint over a coat of red oxide zinc chrome primer after necessary preparation of surfaces complete all as specified & as directed. |
| 8 | S & F in replacement aluminium conductor, steel reinforced (ACSR) jumper of length 1.5 mtr to 3 mtr with ends crimped with lugs and necessary nuts, bolts and washers, connectors including straining, binding and fixing to insulators/fuse units and providing PVC sleeves for jumpers where necessary complete all as specified and as directed. |
| 9 | S&F in replacement compression/crimping type sleeve joints for jointing conductors/jumper connections upto 10 mm dia conductor wire including treatment with conducting jelly complete all as specified anmd as directed. |
| 10 | Supply and fix lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amp of rating 11 KV including connecting with earth lid with necessary nuts, bolts etc. complete all as specified and as directed. |
| 11 | S&F switch air break, gang operated, triple pole, 11000 Volts grade and current rating upto 200 Amps, mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level complete all as specified and directed. |
| 12 | Supply & fix in replacement DO fuse element 11 KV ratings, 10-50 Amps Capacity complete all as specified and directed by Engineer In charge. |
| 13 | S & F in replacement drop out expulsion fuse assembly single pole 25 to 50 Amp capacity, 11000 Volts grade including taking down old unserviceable one complete all as specified and directed. Please Enable Macros to View BoQ information |
| 14 | S & F in replacement drop out expulsion fuse assembly single pole 25 to 50 Amp capacity, 11000 Volts grade including taking down old unserviceable one complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysDec 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender