Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #58641037

Tender For Petty Repairs For Attending Day To Day External Water Supply And Electric Complaints At 17 Shiklhi, Nodal Point-Ii, Naraina Map, Kirby Map Area And Cod Area In The Aor Of Age (U) Water Supply No. 1, Under Ge (U) Water Supply Delhi Cantt-10

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
46 Lakhs
Estimated cost
Bid Submission
05 Dec 2026
13 days left
EMD
92000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Petty Repairs For Attending Day To Day External Water Supply And Electric Complaints At 17 Shiklhi, Nodal Point-Ii, Naraina Map, Kirby Map Area And Cod Area In The Aor Of Age (U) Water Supply No. 1, Under Ge (U) Water Supply Delhi Cantt-10

BOQ

Name of Work:- PETTY REPAIRS FOR ATTENDING DAY TO DAY EXTERNAL WATER SUPPLY AND ELECTRIC COMPLAINTS AT 17 SHIKLHI, NODAL POINT-II, NARAINA MAP, KIRBY MAP AREA AND COD AREA IN THE AOR OF AGE (U) WATER SUPPLY NO. 1, UNDER GE (U) WATER SUPPLY DELHI CANTT-10
Sl. No. Item Description
1Labour only for attending day to day external/treated water supply complaints of all nature including grey water pipe leakage i.e leakage in water supply pipe lines, fitting/fixture, over flow of overhead tank, no water supply in supply tank/direct kitchen tap and grey water supply in various locations & taking out water from trenches during repair including note down the complaints in complaint register complete all as specified and as directed(Note:- Any material required for attending complaints shall be measured and paid separately under respective item herein after as 'Supply only').
2Labour only for attending day to day electric supply complaints of day to day maintenance of existing LT Panels involving replacement of meterials including connecting electrical accessories / spares of water supply installation from 0830 hrs to 1730 hrs and electrical fitting & light, short circuits in pump house including Note down the complaints from various locations in complaints register and distribution to the trademen complete all as directed. (Note:- (i) Any meterial required for atteding complaints shall be measured & paid seperately under respective item here after as 'supply only')(ii) The suitable shift duites as deems fit shall be decision of the Engr-in-charge
3Notes for Item No 1.01 & 1.02 :-(i) Any material required for attending complaints shall be measured & separately under respectvie items here - in- after.(ii) The complaints shall be attended and the defetcs shall be rectified by a team of matric qualified having minimum 03 years experienced electrician/Plumber as applicable assisted with adequate number of helpers as directed by Engineer-in-charge.(iii) The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 50/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues.(iv) In case, after checking & attending the defect, it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Engineer-in- charge is satisfied with contractors view, no recovery will be made.(v) While attending the complaint of water supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A' of BOQ. However, no extra payments shall be made for dewatering.(vi) Cutting of GI pipe in position and threading is also deemed to be included in the job rate (Fittings and fixtures will be measured and paid separetely under respective items of Sch as 'supply only').(vii) All T&P required for attending the Complaints shall be provided by the contractor.)
4(viii) The Pipe Fitter shall always be in possession of die set complete with cutters,Taps, Pipe wrench, Chain wrench, Caulking tools, complete set of spanners and ladders etc as required at site. (ix) The Electrician shall always in possession of all Electrician tools, LT Megger, Earth Tester, Multimeter, Crimpling tool, insulation tape, Hand gloves etc required at site. (x) Rate for taking down/out existing & fittings & fixtures and refixing to make it functional shall be into account. All the fitting & fixtures shall be measured and paid supply only in respective items of BOQ i.e. Ser Item No. 3 to 16, 17, 18.01 to 18.05, 24, 44 to 50 and 54 to 60. (xi) A BOO ordered for material procured by contractor and taken on charge through RV and complaint wise dockets will maintained and USR's duly vetted by AO GE (E/M) for procured materials issued for incorporation in work will be mentioned in BOO. BOO will concorn/approved by Accepting Officer in one time for complete materials to be consumed in work and if any balance quantity of material left with contractor the same will received back on credit USR's & kept on record.
5Supply only GI Socket 'medium grade' ISI Marked superior / standard of a make of following sizes :-
615 mm bore
720mm bore
825mm bore
940mm bore
1050mm bore
11Supply only GI Elbow 'Medium grade', ISI Marked superior / standard of a make of following sizes : -
1215 mm bore
1320mm bore
1425mm bore
1540mm bore
1650mm bore
17Supply only GI Union 'Medium grade', ISI Marked superior / standard of a make of following sizes : -
1815 mm bore
1920 mm bore
2025 mm bore
2140 mm bore
2250 mm bore
23Supply only 'GI Nipple' of suitable length as required at site & ordered by EIC both end screwed 'Medium Grade', ISI marked superior / standard of a make of following sizes:
2415 mm bore
2520mm bore
2625mm bore
2740mm bore
2850mm bore
29Supply only GI Reducing socket 'medium grade' ISI marked superior / standard of a make of the following sizes :-
3020 mm x 15 mm bore
3125 mm x 20 mm bore
3250 mm x 40 mm bore
3325 mm x 15 mm bore
34Supply only GI Solid plug heavy duty ISI Marked superior / standard of a make of following sizes : -
3515 mm bore
3620 mm bore
3725 mm bore
3840 mm bore
3950 mm bore
40Supply only GI Tee 'Medium grade' ISI Marked superior / standard of a make of following sizes : -
4115mm x 15mm x 15mm
4220 mm x 20 mm x 15 mm
4320 mm x 20 mm x 20 mm
4425 mm x 25 mm x 25 mm
4525 mm x 25 mm x 15 mm
4640 mm x 40 mm x 40 mm
4750 mm x 50 mm x 50 mm
4850 mm x 50 mm x 25 mm
49Supply only PTMT float valve of sizes as under, with epoxy coated aluminium rod 250mm length and high density plastic ball of 150mm dia complete all as specified and as directed:-
5015 mm bore
5120 mm bore
5225 mm bore
5350 mm bore
54Supply only Gun metal gate valve, with iron wheel head screwed both ends for iron pipe as per IS-778 complete all as specified and as directed of following sizes:-
5515mm bore
5620 mm bore
5725 mm bore
5840 mm bore
5950 mm bore
60Supply only following items
61Lead pig bar
62Spun yarn
63Labour only for run lead joint by using new lead and new spun yarn including jointing material for CI/DI pipes of following size/bore. (Note: Run lead and spun yarn used for repairing the joints following sizes of pipe will be measured and paid seperately under respective items as supply only.)
6480mm bore
65100 mm bore
66150 mm bore
67Supply only Nuts ,Bolts and Washers 25 to 150 mm long of 6 to 20 mm dia complete all as specified and as directed.
68Supply only 15 mm bore Bib tap of PTMT, any tint, high pressure screwed for male/ female threaded, for pipe of size 15 mm bore complete all as specified and as directed.
69Taking up old GI steel tubing of following sizes with connections from Trenches / floors / walls, complete all as specified and as directed.
7015mm bore
7120 mm bore
7225 mm bore
7340 mm bore
7450 mm bore
75Supply & Laying of GI pipe 'medium grade' ISI mark including all fittings in old/new positions in trenches/wall/floor complete and making good the distributed surfaces as per existing as directed of following sizes. (Note:- Excavation and earth work will be measured and paid separately.)
7615mm bore
7720 mm bore
7825 mm bore
7940 mm bore
8050 mm bore
81Taking up GI/CI/MS/DI Pipe of following sizes including all fittings) with spigot and socketed ends and lead tyton joints including burning out lead joints and recovering lead and making good disturbed surface complete all as specified and as directed.
8280mm bore
83100mm bore
84150 mm bore
85200 mm bore
86Supply, laying jointing,testing DI pipe with class-K-7 spigot socketed ends, conforming to IS-8329 laid in trenches including providing route indicators of suitable height and laying at spacing of @ 50m center to center at GL mentioning name of contractor, date of execution & CA No with name of workof the following sizes complete all as specified and directed by Engineer-in-Charge. (Note : (i) Tyton Joint, Excavation & earth work shall be measured & paid separetely.(ii) Layout for DI Pipe shall be approved by GE before commencement of work.(iii) DI pipe whole quantity of tender shall be procured by contractor in one time and the same will be paid in 1st RAR as material laying at site.(iv) Cost of route indicator shall be deemed included in quoted unit rate.
8780mm bore
88100mm bore
89150 mm bore
90200 mm bore
91Material & Labour for rubber gasket joint including jointing material for CI/DI Pipe of following sizes complete all as specified and as directed .
9280mm bore
93100mm bore
94150 mm bore
95200 mm bore
96Material and labour for DI specials like bends, tapers any type any radius and angle, Tee pieces single branch `Y' junction, double branch, cross (all sockets or socket and spigot) collars, DI connecting pieces one end flanged and other end spigot/socket, reducers/bell mouth pieces one end flanged and other end tapering as bell mouth for the size up to 250 mm dia bore. Please Enable Macros to View BoQ information
97Material and labour for DI specials like bends, tapers any type any radius and angle, Tee pieces single branch `Y' junction, double branch, cross (all sockets or socket and spigot) collars, DI connecting pieces one end flanged and other end spigot/socket, reducers/bell mouth pieces one end flanged and other end tapering as bell mouth for the size up to 250 mm dia bore. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58641037
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 46 Lakhs
LAST DATE 05-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Petty Repairs For Attending Day To Day External Water Supply And Electric Complaints At 17 Shiklhi, Nodal Point-Ii, Naraina Map, Kirby Map Area And Cod Area In The Aor Of Age (U) Water Supply No. 1, Under Ge (U) Water Supply Delhi Cantt-10
Basic Detail
Tender No GE/WS/Token No-36 OF 2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 20 Nov 2026
Submission Date 05 Dec 2026
Open Date 07 Dec 2026
Finance
Tender Value 46 Lakhs
Tender Fee 500
EMD 92000
Exemption Available
Document List
282dade9-4157-4226-b1be-3b3b06b79f17.html
BOQ_897247.xls
tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

282dade9-4157-4226-b1be-3b3b06b79f17.html

xls

BOQ_897247.xls

pdf

tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender