Tender For Special Repair To Block No P-04 Under Ge (N) Akhnoor.
Tender Value
44.23 Lakhs
Estimated cost
Bid Submission
11 Dec 2026
20 days left
EMD
88500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Block No P-04 Under Ge (N) Akhnoor.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of AC sheets corrugated or semi-corrugated in roof covering including ridges,hips,valleys and flashings etc complete all as specified and as directed. |
| 2 | Pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.50mm thick of any colour having tensile strength of 550MPA as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and directed. |
| 3 | Pre-painted galvalume aluminium zinc coating GI based plain sheet 0.50mm thick of any colour having tensile strength of 550MPA as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified as directed. |
| 4 | Dismantling structural steel work including doors,gates but excluding framed truss etc.complete all as specified. |
| 5 | Structural steel work as in roof trusses(framed),trussed purlins,crane gantries,rails and fastening and heavy brackets (Beam,tee,angle,channel or hollow steel section) including distance pieces,cleats etc confirming to Fe-410W(Gde-E-250) quality B complete all as specified as directed. |
| 6 | Demolition of brickwork or stone boulder masonary build in cement mortar including all quoins,arches,pillars etc complete all as specified and as directed. |
| 7 | Brickwork with sub class 'B'(old size ) bricks,straight or curved on plan exceeding 6 meter mean radius build in CM 1:6 complete all as specified and directed. |
| 8 | Description all as per item No.07 above, but except bricks, all as specified and directed. |
| 9 | Taking down cement plaster, on brick or stone wall etc including racking out joints for key scrubbing down with water etc to recive new plaster etc. complete all as specified and directed. |
| 10 | Rendering 15mm thick in cement mortar 1:4 on fair facesof brick work or concrete surfaces finished fair and even without using extra cement complete all as specified and directed. |
| 11 | Rendering 10mm thick cement plaster with cement mortar(1:6) on other than fair faces of brickwork or concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed. |
| 12 | Rendering 10mm thick in CM(1:4) as in ceiling finished even and smooth with out using extra cement complete all as specified and directed. |
| 13 | Repairs to balcony/Facia and soffit of chajjas etc by taking down old rendering 15mm thick to match with the existing thickness in CM 1:4 and hacking clearly the edges and corners smooth and rounded for new plastered area exceeding 30 cm in width or grith including preparation of surfacesand applying two coats exterior emulsion weather proof paint(Apex) as required over one coat of primer including scaffolding work upto height of 7.0 Mtr complete all as specified and dierected. |
| 14 | Preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and as directed. |
| 15 | Preparation of newly plastered surface of wall and applying two coats of cement base paint complete all as specified and directed. |
| 16 | Preparation of old surfaces of wall and applying one coats of white wash complete all as specified and directed |
| 17 | Preparation of old painted surface by washing,rubbing down and stopping of plasterd surfaces and applying one coat of cement base paint white or tinted on wall complete all as specified and directed |
| 18 | Demolition of cement concrete (unreinforced) in ground floor and paving not exc 15mm thickness (below or above griound level) complete all as specified and directed. |
| 19 | Providing cement concrete type C-2 1:3:6 (using 40mm graded stone aggregate)75 mm thick as in plinth protection/flooring etc laid in bays n. exc 2 Sqm each and finishing even and fair on top without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plint protection,filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand(all by weight) all as specified and directed. |
| 20 | Dismantling of wall and ceiling boards (fibre,pulp,insulation etc of any type and any thickness including cover fillets/GI grid framework complete all as specified and directed. |
| 21 | 4mm thick prelaminated designer ceiling board over GI snap grid framework (grid size 600mmx600mm) with powder coated GI angle of size 25x25x3mm,main runner 'T' of size 25x40x3mm,Secondary 'T' of size 25x30x3mm suspended with 3mm GI wire @ 1200mm c/c complete all as specified and directed. |
| 22 | Demolition of stone slab and tiles of any description or thickness laid bedded and pointed in any mortar in floors,aprons etc complete all as specified and directed. |
| 23 | Machine cut kota stone slab flooring of size not less than 53x53cm and 20-25 mm thick laid and jointed with grey cement slurry and mixed with pigment to ;match the shade of slab incl rubbing and polishing with mirror cut polishing 100mm wide marble patti/border all around including 15mm thick screed bed in CM (1:4) complete all as specified and directed. |
| 24 | Kota stone as in vertical surfaces such as riser of steps skriting dado and pillar etc including rubbing & Polishing with mirror cut & including 10 mm thick plaster in CM 1:4 complete all as specified.. |
| 25 | Taking down chowkat or frames with shutters w/o taking off shutter from the frame exceeding 1.5 Sqm but n.exc 4.0 sqm each and removing from site complete all as specified and directed.. |
| 26 | Taking down chowkat or frames with shutters w/o taking off shutter from the frame n. exceeding 1.5 Sqm each and removing from site complete all as specified and directed.. |
| 27 | Steel windows/ventilator (Box type) factory made glass glazed shutter with frame,(glass panes shall be measured and paid seperately) including box type hinges withsteel handle 100mm long and steel peg stay dovetailed or welded incl 2 Nos tower bolts 150mm long and 8mm square bar grills complete all as specified & as shown on drg No CEUZ/TD/1302/2009 Sheet No 1/1 to 1/3 |
| 28 | 3mm thick sheet glass ,ordinary quality and glazing with oil putty/wooden beads in square n.exc 0.5 Square metre in each pane complete all as specified and as directed. |
| 29 | Pressed steel frames for doors with one or more rebates including necessary fixing lugs,hinges,lock strike plates complete including one shop coat of red oxide primer ,providing mild steel 6mm dia threshold and filling hollow frame of size bar of sizes of frame -105 x 60mm complete all as specified and directed. |
| 30 | PCC 1:2:4 type C-0 (using 12.5mm graded crushed stone aggregate) as in filling of pressed steel frame and including 50 mm parapet coping all as specified and directed. |
| 31 | 35mm thick II class hard wood plain framed panneled factory made shutters (two panel) with lock rail and panel of 12mm veneerd particle board with commercial veneering on both face.the size of rail and style as per IS 1003 (Part-I) kiln seasoned chemically pressure treated complete all as specified. |
| 32 | 100mm butt hinges,medium weight cold rolled mild steel complete all as specified and directed. |
| 33 | Aluminium handles cast type anodised of size 150mm long ISI marked complete all as specified and directed. |
| 34 | Aluminium anodised barrel tower bolt 200mm,extruded section complete all as specified and directed. |
| 35 | Alumium anodised sliding door bolts with hasp & stapple extruded section or cast aluminium alloy 300mm long complete all as specified and directed. |
| 36 | Preparation of new steel and iron surfaces of any description,over 10 cm in width or grith,not otherwise described and applying with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 37 | Preparation of old steel and iron surfaces of any description ,over 10 cm in width or grith, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed |
| 38 | Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement for smooth finishing of holes, small patches etc. complete as specified and directed. |
| 39 | Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS), and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction suitable for fixing of modular top cover plate as per numbers of switch modules, for modular switches, sockets, fan regulators, red colour indicator, blank plates etc including 1.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (a) One light/fan point controlled by one switch. |
| 40 | One 3 pin 5 amp socket point controlled by one 5 ampes switch on independent board. |
| 41 | One 3 pin 5 amp socket point controlled by one 5 amps switch on same board. |
| 42 | Ditto All as per item 39 above but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for the following:- (a) One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on independent board. |
| 43 | Modular type switch 6 Amps, single pole, 1way, 1/2 module, 240V, ISI Marked complete all as specified and directed. |
| 44 | Modular type switch 16 Amps, single pole, 1way, 1/2 module, 240V, ISI Marked Complete all as specified and directed. |
| 45 | Modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module,240V,AC ISI Marked Complete all as specified and directed |
| 46 | Modular type socket shuttered type 16 Amps, 2/3 Pin combined 2 module, 240V,AC ISI Marked Complete all as specified and directed |
| 47 | Angle lamp holder, insulated body with back plate for bulb complete all as specified and directed. |
| 48 | Ceiling rose, 3 terminal, PVC/polycarbonate body, ISI marked, complete all as specified and directed. |
| 49 | LED Battens surface mounting General purpose in Extruded Aluminium housing with wattage of 20 watt 4 feet light fitting and removing old unserviceable fitting complete all as specified and directed. |
| 50 | LED INVERTER batten 20 W 4 feet with square profile and polycarbonate channel Lithium ion Battery with Charging time 8 hours-10 hours and back time up to 4 hours and including removing old fittings all as specified and directed and approved by GE |
| 51 | LED bulb 12 watts, 240Volts, 50Hz, pin type and including removing old unserviceable item complete all as specified and directed. |
| 52 | LED security light fitting of capacity 35 Watt LED street light fitting in aluminium PDC(Pressure die cast) housing, toughened glass cover with including Gi bracket fixed with clamps and all connected accessories with IP65 protection with suitable inbuilt surge protector and cable connection from ceiling rose to light fitting and including removing of old unserviceable item complete all as specified and directed. |
| 53 | Sheet metal enclosure acrylic door 240 volts AC,SPN double door distribution board 8 way (conforming to IS-8623 as amended) painted with epoxy based powder coated painting suitable copper busbar, neutral bar, earth bar fully insulated and cable ties for pre-wired, door earthing, Corner shield for better protection, pan assembly for ease of installation and complete connecting cable links with top and bottom removable gland plate reversible doors for IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour shade all as specified and as directed. |
| 54 | MCB SP 6 to 32 Amps 10 KA,\\"C\\" series,AC,240Volts,50Hz, ISI marked complete all as specified and directed |
| 55 | MCB SPN 40 to 63 Amps 10 KA,\\"C\\" series,AC,240Volts,50Hz, ISI marked complete all as specified and directed |
| 56 | Supply and fixing, testing and commissioning outdoor weather proof cubical panel board with suitable size as recommended by manufacturer made out of 3.15mm thick CRCA sheet duly powder coated with locking arrangement on both sides opened, mounted over 50x50x6mm angle iron stand at the bottom of height less than 45 cm above ground level and not less than 30cm in ground / floor mounted duly grouted in PCC 1:3:6 type C1( using 20mm graded stone aggregate) factory made duly powder coated and 300amps aluminium bus bar with suitable thickness as recommended by OEM including panel wiring complete comprising of following :- a) Voltmeter 0-415 volts-01 set,b)Ammeter 0-50 Amp - 01 Setc) Indicator lampsd) MCB DP 40/63 A -07 No (As outgoing)e) MCCB 4 pole 250 A -01 NO (as incomer)f) CTs 50/5 ma -1 setg) Aluminium Busbar 300 Amp -1 set (RYB and Nuetral) complete wiring of panel & Installation all as specified. |
| 57 | Taking down old /unsv earthing and Earthing complete with galvanized steel earth plate electrode 600mm x600mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground leel, connecting to the Galvanised earthing lead strip 32x6mm size, by means of bolts, nuts, heck nuts and washers of galvanized iron and earth lead protected by provision of GI medium grade pipe 65mm bore incl provision of concrete pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC 1:2:4 reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape Gl medium grade 40mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt & charcoal filling, test point made out of 40mm x 8mm Fl with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs, all as per electrical plate No 5 of SSR-1991 Part I and connected to earth test point all as specified or indicated incl testing on completion. |
| 58 | Sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as Bend, Tee, Elbow, Short peices etc concealed in wall/roofs/floors and including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FRLS type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface including cutting and chiseling complete including taking down old unserviceable sub main wiring all as specified and directed.Note:Two run of Sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shalll be measured as one unit. |
| 59 | Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including taking down old unserviceable fans all as specified and directed by Engr-in-Charge.Note: old Unsv ceiling Fan shall be deposited to MES Yard Store. |
| 60 | Supply, laying and testing cable XLPE Insulated,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core including suitable size lugs for making necessary connection on Pole and panel etc including taking down oldinserviceable cable complete all as specified and directed. |
| 61 | Supply, laying and testing cable XLPE Insulated,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core including suitable size lugs for making necessary connection to VTPN DBs/pole etc including taking down old unserviceable cable complete all as specified and directed. |
| 62 | Double walled corrugated (DWC) HDPE pipe with outer wall for being corrugated impacts, excellent ring stiffness (compression strength ) and inner wall for smooth allowing easy insertion of Cable in orange colour with and External influence (IP-66/67) with governing Specification IS 16205:Part 24:2017 of size 40 mm dia for protection of Cable in ducts/walls/pole etc complete all as specified and directed. |
| 63 | Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation of pole and laying of LT cable as in soft/loose soil and getting out complete all as specified and directed. |
| 64 | Returning filling in including spreading ,levelling, watering and wall ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed. |
| 65 | Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point |
| 66 | PCC 1:2;4 type B-0 (using 12.5mm graded crushed stone aggregate) as in pcc coping,kerb stone,kneelers,apex stones,bed plates,etc and the like including weathering,slightly rounded or chamfered angles and throating as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysDec 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender