Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #58637996

Tender For Provision Of Static Water Tank With Overhead Water Refilling At installation Kohassa Under Ge (S) Diglipur.

Issued by Statutory Bodies & Commissions/Committees · North and Middle Andaman, Andaman And Nicobar Islands
Tender Value
43 Lakhs
Estimated cost
Bid Submission
11 Dec 2026
19 days left
EMD
86000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
North and Middle Andaman → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of Static Water Tank With Overhead Water Refilling At installation Kohassa Under Ge (S) Diglipur.

BOQ

Name of Work:- PROVISION OF STATIC WATER TANK WITH OVERHEAD WATER REFILLING AT INS KOHASSA UNDER GE (S) DIGLIPUR.
Sl. No. Item Description
1Earthwork in excavation of any kind of soil by mechanical means (Hydraulic excavator) means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m complete all as specified and as directed.
2Ditto all as per item No 1 above but exceeding 1.50m deep and n.exc 3.00m ditto
3Plain Cement Concrete (1:2:4) mix, Type-B2 (using 40mm graded stone aggregate ) in foundation, filling and mass concrete complete all as specified and as directed.
4M&L for Precast Cement Concrete block masonry with solid blocks, exc. 10 cm in width and setting in CM (1:4), type-C1 (1:3:6) (using 20mm graded aggregates) complete all as specified and as directed.
5M&L for RCC M-30 (using 20mm graded stoe aggregate) as in Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
6Providing rough finished curved formwork to sides of concrete foundations, footings, bases of column, raft and raft beams, sides and soffits (if any) of foundation complete all as specified and as directed.
7M&L for Reinforced Cement Concrete in M-30(Design mix) as in walls retaining walls, basement walls ballast walls and like, any thickness, above top of footing including attached pilasters and buttresses complete all as specified and as directed.
8Providing fair finished Formwork to curved faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc., vertical or to batter for fair finished surface complete all as specified and as directed.
9Providing rough finished Formwork to curved faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for fair finished surface complete all as specified and as directed.
10M&L for moorum filling in floors laid in lagers n.exc. 15cm thick spread levelled and rammed including Watering complete all as specified and as directed.
11Surface excavation n.exc. (not exceeding) 30cm deep and averaging 15cm deep and getting out soft / loose soil complete all as specified and as directed.
12Removing excavated soils to a distance beyound 50 m and upto a total distance of 250m and depositing where directed at level n.exc. 1.5m above the starting point complete all as specified and as directed.
13M&L for hard core of broken stone or boulders of gauge n.exc.63mm, deposited, spread, levelled in layers n.exc.15cm thick, watered and rammed to a true surfacecomplete all as specified and directed.
14M&L for 75mm thick PCC (1:3:6), type-C2 (using 40mm graded stone aggregate) as in plinth protection finished even & smooth without using extra cement making 10mm wide joints at every 3m interval and at every corner, filled with hot mix of bitumen complete all as specified and as directed.
15M&L for rendering 10mm thick plaster in CM (1:3) on concrete surfaces without using extra cement with water proofing compound complete all as specified and as directed.
16Supply only integral water poofing compound complete all as specified and as directed.
17M&L for rendering 15mm thick plaster on fair faces of brick /concrete surfaces in CM (1:6) on finished without using extra cement complete all as specified and as directed.
18M&L for applying two coats of exterior grade acrylic emulsion paint over a coat of primer including preparation of new surpaces complete all as specified and as directed.
19M&L for rendering 15mm thick plaster on other than fair faces of brick /concrete surfaces in CM (1:4) on finished without using extra cement complete all as specified and as directed.
20M&L for RCC (1:3:6), Type-B1 (using 20mm graded aggegate) as in coping, bed plates etc., complete all as specified and as directed.
21M&L for RCC M-30 using 20mm graded stoe aggregate as in stairways including steps string pieces, carriages etc complete but excluding landings etc complete all as specified and as directed.
22Providing rough finished formwork to staircaes with sloping or stepped soffits complete all as specified and as directed.
23Providing rough finished flat formwork to concrete flats , trades similar work exc. 10cm but n.exc. 20 cm in wide complete all as specified and as directed.
24M&L for High strength deformed bars( TMT bars) 10 mm dia and over as in reinforcement for concrete cut to length , bent to shape requred, including cranking , bending spirally for columns hooking for columns hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
25S&F framed work such as grills, gratings, etc with ends of bars shouldered and /or reveted, or forged into spikes, framed gurad bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and simlar work conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
26S&F Steel work in tubular trusses, Purlin,Post etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and as directed.
27S&F of Plates (plain or chequered)Channels, square of Fe 290 (Gde E-165) cut or notched (ordinary and counter sunk) forming holes, wihtou any attachement complete all as specified and as directed.
28M&L for preparation of newly steel surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and as directed.
29S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of Blue Sepoy/Ciril coloured, Grade AZ-150 GSM, having tensile strength of 550 MPa, used as roof covering/cladding to wall, fixed with self tapping screws, as per manufacturer's instructions, complete all as specified and directed
30S&F for Non woven geotextiles of minimum 120 gm/sqm placed on backfilling complete all as specified and as directed.
31M&L for sand filling for the road including spreading levelling & ramming in layers n.exc. 25mm thick complete all as specified and as directed.
32Supplying and laying of bi-axial extruded high modulus polypropylene geogrid for base/ sub base reinforcmenet having minimum tensile strength 40 KN/m complete all as specified and as directed.
33Applying evenly tack coat of industrial bitumen 85.25 at the rate of 1.20Kg per sqm including cleaning surfaces complete all as specified and as directed.
34Returning filling in soil including spreading leveling watering and well ramming in layers n.exc. 25mm thick each complete all as specified and as directed.
35Removing excavated soil n.exc. 50m and depositing where directed at a level n.exc.1.5m complete all as specified and as directed.
36Rolling and consolidating formation surfaces in cutting including watering as necessary, filling in the depressions with approved earth which occur during the process, with 8 to 12 tonne power roller, consolidating to required gradient and camber complete all as specified and as directed.
37M&L for moorum / red bajri filling in floors or pavings, laid in layers n.exc 15cm thick , spread, levelled and rammed including watering etc complete all as specified and as directed.(300mm thick)
38M&L for Soling (or sub base) 200mm thick (spread thickness), in two layers of 100mm thickness each, with broken boulders or quarried stone, interstices filled, surface formed and rolled and consolidated with 8 to 10 tonne power roller to required gradient and camber complete all as specified and as directed.
39M&L for 150mm thick WMM in two layer of 75mm (compacted thickness), with coarse aggregates of grading 2 (63 to 40mm size) or of grading 3 (50 to 20mm size), spread, rolled and consolidated to gradient and camber required complete all as specified and as directed.
40Preparing surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc., complete all as specified and as directed.
41M&L for 100mm thick cement concrete (1:4:8) type-D2 (using 40 mm graded stone aggregate) as Sub base of flooring complete all as specified and as directed.
42M&L for Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete all as specified and as directed.Note:- The rate include the cost of formwork up to 250mm thick concrete.
43M&L for finishing concrete roads, pavements by brooming complete all as specified and as directed.
44Forming 20mm thick expansion joints for full depth filled with perforated bituminous filler and top 30mm primed and sealed with sealing compound grade A complete all as specified and as directed.
45Forming construction(Dummy) joints 65mm deep x 10mm wide filled with perforated bituminous filler and top 30mm primed and sealed with sealing compound grade A complete all as specified and as directed.
46S&F for monoblock pump 5 HP, 28 Mtr head, 3 phase, 2 pole, 50 Hz, 6.4 lps, 80x 65mm suction /delivery line including necessary PCC foundation work and cover over the pump complete all as specified and as directed.
47S&F for DOL pump starter for 5 HP monoblock pump set including necessary fixing arrangement and covered from all weather complete all as specified and as directed.
48S&F for openwell submersible pump 5 HP, 14m-26M head, 3 phase, 1050-300 lpm, 80x65mm suction/ delivery line complete all as specified and as directed.
49S&F for DOL pump starter for 5 HP submersible pump set including necessary fixing arrangement and covered from all weather complete all as specified and as directed.
50Supply and laying of 80 mm dia heavy-class GI pipe, including cutting, threading, jointing, necessary fittings, clamps, supports, fixing, testing and all required accessories, complete as specified and as directed
51Supply and laying of 65 mm dia heavy-class GI pipe, including cutting, threading, jointing, necessary fittings, clamps, supports, fixing, testing and all required accessories, complete as specified and as directed
52Supply and fixing of 65 mm dia butterfly valve suitable for water supply pipeline, complete with operating mechanism, body, disc, stem, rubber sealing, necessary gaskets, nuts, bolts, jointing materials, installation, testing and commissioning, complete as specified and as directed
53Supply and fixing of 80 mm dia sluice valve, PN 1.6, suitable for water supply pipeline, flanged type, handwheel operated, complete with body, bonnet, wedge, spindle, gland packing, necessary gaskets, nuts, bolts, jointing materials, installation, testing and commissioning, complete as specified
54Supply and fixing of 80 mm dia foot valve with strainer, suitable for water pump suction pipeline, complete with cast iron/ductile iron body, valve disc, seat, sealing arrangement, perforated strainer, necessary nuts, bolts, gaskets, jointing materials, installation, testing and commissioning, complete as specified
55Providing and fixing gun metal non- return valve of approved quality (screwed end) 80mm dia vertical type complete all as specified and as directed.
56Excavation in trenches, n.exc. 1.5m wide and n.exc. 1.5m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, per ,pier holes, etc. n.exc. 10 sq m on plan and n.exc. 1.5m in depth and getting out any kind of soil complete all as specified and as directed.
57Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and as directed.
58Supplying and laying of DWC HDPE pipe 40 mm outer dia and 32mm inner dia ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required complete all as specified and as directed.
59Supply, laying and testing of XLPE insulated, screened, PVC bedded, galvanized steel strip/wire armoured, PVC sheathed heavy-duty electric power cable, 1100 V grade, with stranded aluminium conductor, 4 Core × 16 Sq.mm, including necessary laying, fixing, cable clamps, identification tags, cable glands, aluminium lugs, termination, testing and all required accessories, complete as specified
60Supply and fixing of 4-way, double-door, SPN sheet steel MCB distribution board, 240 V, surface/recessed mounting, complete with tinned copper busbar, neutral busbar, earth bar, DIN rail, internal interconnections, powder-coated finish, earthing and all necessary accessories, excluding MCB/RCCB/isolator, complete as specified and directed
61S&F 415 volts 10 KA 'C' series MCB TPN 40-100 Amps complete all as specified and as directed.
62M&L for applying epoxy coated water proofing compound to seals concrete pores and cracks, prevent seepage, resists algae etc., including preparation of internal wall surfaces complete all as specified and as directed.
63S&F PVC water bar of 4-6 mm thick of width 150-250 mm as in construction joint either vertical or horizontal direction complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58637996
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43 Lakhs
LAST DATE 11-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Static Water Tank With Overhead Water Refilling At installation Kohassa Under Ge (S) Diglipur.
Basic Detail
Tender No 8250/E8
Bidding Type Tender
Location
City North and Middle Andaman
State Andaman And Nicobar Islands
Key Dates
Publish Date 20 Nov 2026
Submission Date 11 Dec 2026
Open Date 15 Dec 2026
Finance
Tender Value 43 Lakhs
Tender Fee 500
EMD 86000
Exemption Available
Document List
61227620-f841-4be7-99ad-058c2be7d28d.html
8250TENDER.pdf
BOQ_897123.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Dec 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

61227620-f841-4be7-99ad-058c2be7d28d.html

pdf

8250TENDER.pdf

xls

BOQ_897123.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender