Tender For E-Quotation For Rate Estimation For The Work Of Construction Of New District Court Building At Dharashiv Tq. & Dist. Dharashiv.
Tender Overview
Project Description
Tender for E-Quotation For Rate Estimation For The Work Of Construction Of New District Court Building At Dharashiv Tq. & Dist. Dharashiv. , Part - A (Work Portion) , Providing And Fixing Modular Door Assembly Comprising Factory-Made Modular Door Frame Of Approved Size And Section, Including Decorative Moulding Along The Edges Of The Door Frame And Decorative Edge Moulding Along The Edges Of The Door Shutter, Incorporating Bullnose And Round-Over Profiles For Door Frames And Door Shutters, Including Rounded Edge Profiles (Bullnose & Post-Formed) As Per Approved Design. The Door Shall Comprise 36 Mm Thick Solid-Core Flush Door Shutter Finished With Approved Decorative Laminate On Both Faces, Complete With Necessary Lipping And Machine Edge Banding. The Door Shall Be Provided Approved Make 270 Mm Euro 60 Mm Bs Multi-Bolt Mortise Lock Body (Model 7577), Godrej Or Equivalent Approved Make D-Type Tubular Lever Handle With Round Rose (Model 8705), Compatible Euro Profile Cylinder, Including Strike Plate, Keys, Hinges, Screws, Necessary Fixing Arrangements, Fixtures, Fasteners And All Other Required Accessories. Complete In All Respects As Per Approved Drawings, Manufacturers Specifications And As Directed By Engineer-In-Charge. , Providing And Fixing Hydraulic Door Closer Of Approved Make, Suitable For The Specified Door Size And Weight, Complete With Aluminium / Stainless Steel Body, Adjustable Closing And Latching Speed Control, Arm Assembly, Mounting Brackets, Screws, Fasteners And All Necessary Accessories. The Door Closer Shall Be Fixed To The Door Shutter And Frame As Per Manufacturers Recommendations, Including Adjustment, Testing And Commissioning, Complete In All Respects As Per Approved Drawings, Manufacturers Specifications And As Directed By Engineer-In-Charge. , Providing And Fixing Concealed Hydraulic Door Closer Of Approved Make, Suitable For 36 Mm Thick Door Shutter, Complete With Hydraulic Closing Mechanism, Adjustable Closing And Latching Speed Control, Concealed Body, Sliding Arm / Guide Rail, Mounting Brackets, Fixing Screws, Fasteners And All Necessary Accessories. The Door Closer Shall Be Concealed Within The Door Shutter And Frame As Per Manufacturers Recommendations, Including Necessary Cutting, Recessing, Installation, Adjustment, Testing And Commissioning, Complete In All Respects As Per Approved Drawings, Manufacturers Specifications And As Directed By Engineer-In-Charge. , Providing And Fixing Factory-Made Three Track Upvc Sliding Windows Of Approved Make With Wooden Grain Finish, Comprising 2 Glass Sliding Sashes And 1 Insect Mesh Sash, Each Sash Being Half Of The Overall Window Width, Made Out Of Upvc Multi-Chambered Profiles Of Big Series, Having Window Frame Section Of Size 122 Mm × 54 Mm And Sash Section Of Size 64 Mm × 47 Mm, Reinforced With Galvanized Iron (G.I.) Sections Wherever Required, Including Single-Glazed Solar-Control Glass Panes Of Approved Thickness And Performance, Insect Mesh With Suitable Frame, Glazing Beads, Epdm Gaskets, Wool Pile Weather Strips, Sliding Tracks, Rollers, Locking Arrangements, Handles, Interlocks, Drainage Provisions, Necessary Fasteners, Fixtures And Accessories.The Complete Window Assembly Shall Meet The Applicable Thermal Performance Requirements, Including Prescribed U-Value, Solar Heat Gain Coefficient (Shgc), Visible Light Transmittance (Vlt) And Air Infiltration Requirements, In Accordance With The Applicable Griha / Igbc Green Building Rating Criteria. The Window Shall Be Fixed In Position With Suitable Fasteners And Perimeter Sealing With Approved Weatherproof Silicone Sealant. The Manufacturer Shall Provide A Minimum 10-Year Written Warranty For The Wooden-Grain Laminated / Foil-Coated Finish Against Peeling, Cracking, Blistering, Delamination, Fading And Discoloration Due To Uv Exposure And Normal Weather Conditions. The Warranty Certificate Shall Be Submitted To The Engineer-In-Charge. Complete In All Respects As Per Approved Drawings, Manufacturers Specifications And As Directed By Engineer-In-Charge. , Providing And Fixing Factory-Made Upvc Casement Windows Of Approved Make With Wooden Grain Laminated / Foil-Coated Finish, Comprising Multi-Chambered Upvc Frame And Shutter Profiles, Reinforced With Galvanized Iron (G.I.) Sections Wherever Required, Including Single-Glazed Solar-Control Glass Panes Of Approved Thickness And Performance, Glazing Beads, Epdm Gaskets, Weather Seals, Stainless Steel Friction Hinges, Heavy-Duty Handles, Locking Arrangements, Stays, Interlocks, Necessary Fixtures, Fasteners And Accessories. The Complete Window Assembly Shall Meet The Applicable Thermal Performance Requirements, Including Prescribed U-Value, Solar Heat Gain Coefficient (Shgc), Visible Light Transmittance (Vlt) And Air Infiltration Requirements, In Accordance With The Applicable Griha / Igbc Green Building Rating Criteria. The Window Shall Be Fixed In Position With Suitable Fasteners, Including Perimeter Sealing With Approved Weatherproof Silicone Sealant. The Manufacturer Shall Provide A Minimum 10-Year Written Warranty For The Wooden-Grain Laminated / Foil-Coated Finish Against Peeling, Cracking, Blistering, Delamination, Fading And Discoloration Due To Uv Exposure And Normal Weather Conditions. The Warranty Certificate Shall Be Submitted To The Engineer-In-Charge. Complete In All Respects As Per Approved Drawings, Manufacturers Specifications And As Directed By Engineer-In-Charge. , Providing And Fixing Factory-Made Upvc Windows Of Approved Make With Wooden Grain Laminated / Foil-Coated Finish, Comprising Multi-Chambered Upvc Outer Frame And Shutter Profiles With Partly Fixed And Partly Openable Casement Shutters As Per Approved Drawings, Reinforced With Galvanized Iron (G.I.) Sections Wherever Required, Including Single-Glazed Solar-Control Glass Panes Of Approved Thickness And Performance, Glazing Beads, Epdm Gaskets, Weather Seals, Stainless Steel Friction Hinges, Heavy-Duty Handles, Locking Arrangements, Stays, Interlocks, Necessary Fixtures, Fasteners And Accessories. The Complete Window Assembly Shall Meet The Applicable Thermal Performance Requirements, Including Prescribed U-Value, Solar Heat Gain Coefficient (Shgc), Visible Light Transmittance (Vlt) And Air Infiltration Requirements, In Accordance With The Applicable Griha / Igbc Green Building Rating Criteria. The Window Shall Be Fixed In Position With Suitable Fasteners, Including Perimeter Sealing With Approved Weatherproof Silicone Sealant. The Manufacturer Shall Provide A Minimum 10-Year Written Warranty For The Wooden-Grain Laminated / Foil-Coated Finish Against Peeling, Cracking, Blistering, Delamination, Fading And Discoloration Due To Uv Exposure And Normal Weather Conditions. The Warranty Certificate Shall Be Submitted To The Engineer-In-Charge. Complete In All Respects As Per Approved Drawings, Manufacturers Specifications And As Directed By Engineer-In-Charge. , Providing And Fixing Factory-Made Three Track Upvc Sliding Windows Of Approved Make With Wooden Grain Finish, Comprising 2 Glass Sliding Sashes And 1 Insect Mesh Sash, Each Sash Being Half Of The Overall Window Width, Made Out Of Upvc Multi-Chambered Profiles Of Big Series, Having Window Frame Section Of Size 122 Mm × 54 Mm And Sash Section Of Size 64 Mm × 47 Mm, Reinforced With Galvanized Iron (G.I.) Sections Wherever Required, Including Single-Glazed Solar-Control Glass Panes Of Approved Thickness And Performance, Georgian Bars In Approved Pattern And Arrangement, Insect Mesh With Suitable Frame, Glazing Beads, Epdm Gaskets, Wool Pile Weather Strips, Sliding Tracks, Rollers, Locking Arrangements, Handles, Interlocks, Drainage Provisions, Necessary Fasteners, Fixtures And Accessories. The Complete Window Assembly Shall Meet The Applicable Thermal Performance Requirements, Including Prescribed U-Value, Solar Heat Gain Coefficient (Shgc), Visible Light Transmittance (Vlt) And Air Infiltration Requirements, In Accordance With The Applicable Griha / Igbc Green Building Rating Criteria. The Window Shall Be Fixed In Position With Suitable Fasteners And Perimeter Sealing With Approved Weatherproof Silicone Sealant. The Manufacturer Shall Provide A Minimum 10-Year Written Warranty For The Wooden-Grain Laminated / Foil-Coated Finish Against Peeling, Cracking, Blistering, Delamination, Fading And Discoloration Due To Uv Exposure And Normal Weather Conditions. The Warranty Certificate Shall Be Submitted To The Engineer-In-Charge. Complete In All Respects As Per Approved Drawings, Manufacturers Specifications And As Directed By Engineer-In-Charge. , Providing And Fixing Factory-Made Upvc Casement Windows Of Approved Make With Wooden Grain Laminated / Foil-Coated Finish, Comprising Multi-Chambered Upvc Frame And Shutter Profiles, Reinforced With Galvanized Iron (G.I.) Sections Wherever Required, Including Single-Glazed Solar-Control Glass Panes Of Approved Thickness And Performance, Georgian Bars In Approved Pattern And Arrangement, Glazing Beads, Epdm Gaskets, Weather Seals, Stainless Steel Friction Hinges, Heavy-Duty Handles, Locking Arrangements, Stays, Interlocks, Necessary Fixtures, Fasteners And Accessories. The Complete Window Assembly Shall Meet The Applicable Thermal Performance Requirements, Including Prescribed U-Value, Solar Heat Gain Coefficient (Shgc), Visible Light Transmittance (Vlt) And Air Infiltration Requirements, In Accordance With The Applicable Griha / Igbc Green Building Rating Criteria. The Window Shall Be Fixed In Position With Suitable Fasteners, Including Perimeter Sealing With Approved Weatherproof Silicone Sealant, Complete In All Respects As Per Approved Drawings, Manufacturers Specifications And As Directed By Engineer-In-Charge. , Providing And Fixing Factory-Made Upvc Windows Of Approved Make With Wooden Grain Laminated / Foil-Coated Finish, Comprising Multi-Chambered Upvc Outer Frame And Shutter Profiles With Partly Fixed And Partly Openable Casement Shutters As Per Approved Drawings, Reinforced With Galvanized Iron (G.I.) Sections Wherever Required, Including Single-Glazed Solar-Control Glass Panes Of Approved Thickness And Performance, Decorative Georgian Bars In Approved Pattern And Arrangement, Glazing Beads, Epdm Gaskets, Weather Seals, Stainless Steel Friction Hinges, Heavy-Duty Handles, Locking Arrangements, Stays, Interlocks, Necessary Fixtures, Fasteners And Accessories. The Complete Window Assembly Shall Meet The Applicable Thermal Performance Requirements, Including Prescribed U-Value, Solar Heat Gain Coefficient (Shgc), Visible Light Transmittance (Vlt) And Air Infiltration Requirements, In Accordance With The Applicable Griha / Igbc Green Building Rating Criteria. The Window Shall Be Fixed In Position With Suitable Fasteners, Including Perimeter Sealing With Approved Weatherproof Silicone Sealant. The Manufacturer Shall Provide A Minimum 10-Year Written Warranty For The Wooden-Grain Laminated / Foil-Coated Finish Against Peeling, Cracking, Blistering, Delamination, Fading And Discoloration Due To Uv Exposure And Normal Weather Conditions. The Warranty Certificate Shall Be Submitted To The Engineer-In-Charge. Complete In All Respects As Per Approved Drawings, Manufacturers Specifications And As Directed By Engineer-In-Charge. , Providing, Fabricating And Fixing Suspended Direction Signboard Of Approved Size And Design, Made Out Of Aluminium Composite Panel (Acp) / Suitable Approved Material, With Digitally Printed Graphics, Directional Arrows, Lettering And Signage Details As Per Approved Drawings. The Board Shall Be Suspended From The Ceiling / Soffit Using Suitable Stainless Steel Threaded Rods, Brackets, Clamps And Supporting Arrangements, Including Necessary Framework, Fasteners, Fixtures And Accessories, Complete In All Respects As Per Approved Drawings, Specifications And As Directed By Engineer-In-Charge. , Providing, Fabricating And Fixing Wall-Mounted Direction Signboard Of Approved Size, Shape And Design, Made Out Of Aluminium Composite Panel (Acp) Of Approved Thickness, With Digitally Printed Graphics, Directional Arrows, Lettering, Symbols And Signage Details As Per Approved Drawings. The Board Shall Be Fixed To The Wall Using Suitable Aluminium / Stainless Steel Brackets, Screws, Fasteners And Necessary Supporting Arrangements, Including Edge Finishing, Necessary Fixtures And Accessories, Complete In All Respects As Per Approved Drawings, Specifications And As Directed By Engineer-In-Charge. , Providing, Fabricating And Fixing Room Identification Signboard Of Approved Size, Shape And Design, Made Out Of Aluminium Composite Panel (Acp) / Acrylic Sheet Of Approved Thickness, With Digitally Printed / Vinyl-Cut Lettering, Room Numbers, Names, Symbols And Identification Details As Per Approved Drawings. The Board Shall Have Smooth Finished Edges And Approved Colour Combination, Fixed To The Wall Using Suitable Stainless Steel Screws, Concealed Fasteners Or Approved Adhesive, Including All Necessary Fixtures, Fittings And Accessories, Complete In All Respects As Per Approved Drawings, Specifications And As Directed By Engineer-In-Charge. , Providing, Fabricating And Fixing Floor Directory Signage Of Approved Size, Shape And Design, Made Out Of Aluminium Composite Panel (Acp) / Acrylic Sheet Of Approved Thickness, Displaying Floor-Wise Department Names, Room Numbers, Directional Arrows, Symbols, Fire Exit Details And Other Identification Information As Per Approved Drawings. The Signage Shall Have Digitally Printed / Vinyl-Cut Lettering And Graphics With Approved Colour Combination, Smooth Finished Edges And Suitable Supporting Framework Wherever Required. The Signage Shall Include Fire Exit And Floor Identification Details As Per Manufacturers Specifications, Ada-Compliant Design And Modular System. The Board Shall Be Fixed To The Wall Using Stainless Steel Brackets, Screws, Concealed Fasteners And Necessary Accessories, Complete In All Respects As Per Approved Drawings, Specifications And As Directed By Engineer-In-Charge. , Providing, Fabricating, Supplying And Installing In Position Emergency Direction Signage Of Approved Size, Shape And Design, Made Out Of Approved-Grade Acp / Acrylic Sheet, Displaying Emergency Exit Symbols, Directional Arrows, Evacuation Routes And Other Emergency Identification Details As Per Approved Fire And Safety Drawings. The Signage Shall Include Fire Order Board Of Size 3-0 X 4-0, Made Out Of 3 Mm Thick Opaque Pvc Foam Board, With Computerized-Cut Lettering And Graphics Using Non-Reflective, Self-Adhesive Pvc Vinyl, Including Painted Finish To The Foam Board And Displaying The Prescribed Fire Safety Instructions And Information As Per Approved Drawings. The Signage Shall Be Of Ada-Compliant Design And Modular System, With Photoluminescent / Reflective Lettering And Symbols Wherever Required, Including Necessary Supporting Framework, Wall-Mounting Brackets, Stainless Steel Screws, Fasteners, Fixing Arrangements And All Other Necessary Accessories, Complete In All Respects As Per Approved Drawings, Applicable Fire And Safety Requirements And As Directed By Engineer-In-Charge. , Providing, Fabricating And Fixing Internal Directional Signage Of Approved Size, Shape And Design, Made Out Of Aluminium Composite Panel (Acp) / Acrylic Sheet Of Approved Thickness, Displaying Directional Arrows, Department Names, Room Numbers, Floor Details, Symbols And Other Wayfinding Information As Per Approved Drawings. The Signage Shall Have Digitally Printed / Vinyl-Cut Lettering And Graphics With Approved Colour Combination, Smooth Finished Edges And Suitable Supporting Framework Wherever Required, Including Necessary Wall-Mounted Brackets, Stainless Steel Screws, Fasteners, Fixtures And Accessories, Complete In All Respects As Per Approved Drawings, Specifications And As Directed By Engineer-In-Charge. , Providing, Supplying And Fixing Modular Modern 4-Seater Office Cubicle Workstation Of Approved Size, Design And Layout, Arranged In A Cross-Shaped Configuration, Fabricated With 18 Mm Thick Pre-Laminated Particle Board / Mdf Board Of Approved Make And Shade, Comprising Individual Angular Worktops, Side Supports, Modesty Panels And Central Cross-Shaped Intermediate Partitions With Raised Privacy Panels To Provide Separate Workspaces For Four Users. The Workstation Shall Include Integrated Storage Cabinets With Open Shelves, Drawer Units With Locking Arrangements, Handles, Pvc Edge Banding, Suitable Aluminium / Powder-Coated Metal Supporting Framework, Cable Management Provisions, Grommet Holes And All Necessary Hardware, Fasteners, Fittings And Accessories. All Exposed Surfaces Shall Be Finished With Approved Laminate In Selected Colours And Shades, Complete In All Respects As Per Approved Drawings, Specifications And As Directed By Engineer-In-Charge. , Providing And Fixing External Dry Cladding Of Approved Natural Sandstone / Similar Approved Stone Material Of Specified Thickness, Size, Colour And Texture, Including Cutting, Dressing, Edge Finishing, Drilling And Providing Necessary Slots / Holes For Fixing. The Stone Cladding Shall Be Fixed To The External Wall Using Approved Grade Stainless Steel (Ss 304 / Ss 316) Brackets, Anchor Fasteners, Cramps, Clamps And Suitable Supporting Framework, With Necessary Provision For Ventilation And Drainage Behind The Cladding. The Work Shall Include All Necessary Fixtures, Fasteners, Accessories, Joint Treatment, Alignment, Scaffolding And Finishing, Complete As Per Approved Drawings, Manufacturers Specifications And As Directed By Engineer-In-Charge. , Providing, Fabricating And Fixing Three-Dimensional (3D) Metal Letters For Building Name Boards, Logos And Identification Signage, Made Out Of Approved Grade Stainless Steel (Ss 304) Sheet Of Specified Thickness, Duly Laser-Cut, Fabricated And Finished With Approved Brushed / Mirror / Matte / Powder-Coated Finish. The Letters Shall Be Fabricated With Required Depth And Raised Profile, Including Return Edges, Internal Stiffeners Wherever Required, Concealed Mounting Studs, Spacers, Templates, Fasteners And Necessary Supporting Arrangements For Fixing On The Approved Background Surface. The Work Shall Include Alignment, Levelling, Installation And All Necessary Fixtures And Accessories, Complete As Per Approved Drawings, Lettering Details And As Directed By Engineer-In-Charge. , Providing, Fabricating And Fixing Decorative Items Made Out Of Fibre Reinforced Plastic (Frp) Of Approved Design, Shape, Size And Thickness, Including Moulding, Casting, Surface Preparation, Application Of Approved Gel Coat Finish, Colouring And Polishing, Complete With Necessary Supporting Framework, Brackets, Clamps, Fasteners, Fixtures And Accessories For Proper Installation. The Finished Surface Shall Be Smooth, Uniform And Free From Cracks, Air Bubbles And Other Defects, Including All Necessary Cutting, Fitting, Jointing, Finishing And Installation At Designated Locations, Complete As Per Approved Drawings, Manufacturers Specifications And As Directed By Engineer-In-Charge. , Providing And Fixing Wet Wall Cladding With Approved Natural Sandstone / Similar Approved Stone Having Blasted Stone Finish, Of Specified Size, Thickness, Colour And Texture, Including Cutting, Dressing, Edge Finishing And Preparation Of Stone Pieces. The Stone Shall Be Fixed To The Prepared Wall Surface Using Approved Cement Mortar Of Specified Proportion, Including Backing Coat, Necessary Levelling, Alignment, Joint Filling With Approved Matching Cementitious Grout, Cleaning And Finishing. The Work Shall Include All Necessary Scaffolding, Materials, Labour, Tools And Tackles, Complete As Per Approved Drawings, Specifications And As Directed By Engineer-In-Charge. , Providing, Carving And Fixing Decorative Designs, Patterns, Motifs And Ornamental Elements In Natural Sandstone / Approved Similar Natural Stone, Of Approved Size, Thickness, Colour And Texture, With Blasted Stone Finish, Including Cutting, Shaping, Chiselling, Hand Carving / Machine Carving, Dressing, Edge Finishing And Polishing Wherever Required, As Per Approved Drawings And Design Details. The Work Shall Include Preparation Of Stone Surfaces, Intricate Detailing, Matching Of Patterns, Jointing, Fixing In Position Using Approved Cement Mortar / Suitable Mechanical Fasteners Wherever Required, Scaffolding, Cleaning And Finishing, Complete In All Respects As Per Approved Drawings, Specifications And As Directed By Engineer-In-Charge. , Providing, Designing, Fabricating And Installing Structural Glazed Aluminium Curtain Wall System Using Aluminium Extruded Sections Of Approved Make, Size And Design, Comprising Vertical Mullions And Horizontal Transoms With Suitable Thermal Breaks Wherever Required, Including Single / Double-Glazed Glass Panels Of Approved Thickness, Type, Colour And Performance, Fixed By Structural Glazing / Pressure Glazing System Using Approved Structural Silicone Sealant, Epdm Gaskets, Glazing Beads, Aluminium Pressure Plates, Cover Caps, Cleats, Brackets, Anchor Fasteners, Stainless Steel Bolts And Screws, Including Necessary Provisions For Expansion, Drainage And Weatherproofing. The System Shall Be Designed To Withstand Applicable Wind Loads And Shall Satisfy The Specified Air Infiltration, Water Penetration And Structural Performance Requirements. The Complete Curtain Wall Assembly, Including Glazing, Aluminium Framing And Associated Components, Shall Meet The Applicable Thermal And Energy Performance Requirements, Including Prescribed U-Value, Solar Heat Gain Coefficient (Shgc), Visible Light Transmittance (Vlt) And Air Infiltration Requirements, In Accordance With The Applicable Griha / Igbc Green Building Rating Criteria. The Work Shall Include Fabrication, Transportation, Erection, Alignment, Sealing, Testing And All Necessary Fixtures, Fittings And Accessories, Complete As Per Approved Drawings, Manufacturers Specifications And As Directed By Engineer-In-Charge. , Providing, Supplying And Fixing Invisible Safety Grill System For Windows, Balconies And Openings, Comprising High-Tensile Stainless Steel (Ss 316) Wire Ropes Of Approved Diameter, Generally 2 Mm, Arranged Vertically At Specified Spacing, Including Suitable Stainless Steel Top And Bottom Aluminium / Ss Channels, Tensioning Bolts, End Fittings, Locking Arrangements, Clamps, Fasteners, Wall / Slab Anchorages And All Necessary Accessories. The Wires Shall Be Properly Tensioned And Securely Fixed To Provide The Required Safety And Protection Without Obstructing The External View. Including Drilling, Anchoring, Installation, Adjustment And Finishing, Complete In All Respects As Per Approved Drawings, Manufacturers Specifications And As Directed By Engineer-In-Charge. , Providing And Laying Natural Stone Cobblestone Paving Of Approved Type, Colour, Texture, Size And Thickness, Including Hand-Cut / Dressed Stone Cobbles Laid In The Approved Pattern Over A Properly Prepared And Compacted Base With Specified Sand Bedding, Maintaining Uniform Levels, Line, Gradient And Slope. Including Filling Of Joints With Fine Sand / Approved Jointing Material, Compacting And Seating The Cobblestones, Cutting And Dressing At Edges, Curves And Junctions, Providing Necessary Edge Restraints, And All Materials, Labour, Transportation, Tools And Equipment Required To Complete The Work As Per Approved Drawings, Specifications And As Directed By Engineer-In-Charge. , Providing, Designing, Fabricating, Supplying And Fixing 3D Indian National Emblem (Ashoka Emblem) Of Approved Size, Design And Profile, Fabricated From Stainless Steel (Ss 304) Sheet Of Approved Thickness, With Precision-Cut, Formed And Fabricated Components, Including Detailed Ashoka Lion Capital And Base, As Per Approved Design. The Emblem Shall Be Provided With Brushed Hairline Matt Finish / Gloss Finish, As Approved By Engineer-In-Charge, Including Necessary Surface Treatment, Polishing, Edge Finishing, Backing Support, Concealed Mounting Brackets, Studs, Fasteners, Spacers And All Required Fixing Accessories. The Emblem Shall Be Securely Mounted On The Approved Background Surface, Complete In All Respects As Per Approved Drawings, Specifications And As Directed By Engineer-In-Charge.
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender