Tender For Improvement Of Kulsi- Garubandha-Bangelbila - Baregaon Road By Providing Mitigation Measures Under Sdmf For The Year 2024-25, Palashbari Lac, Kamrup District
Tender Value
14.62 Crore
Estimated cost
Bid Submission
09 Dec 2026
18 days left
EMD
29.25 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup Metro → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Improvement Of Kulsi- Garubandha-Bangelbila - Baregaon Road By Providing Mitigation Measures Under Sdmf For The Year 2024-25, Palashbari Lac, Kamrup District
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in ordinary Rock by manual meansExcavation in ordinary Rock by manual means - Excavation in ordinary rock using manual means including loading in a truck and carrying of excavated material to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3.5. (Manual means should be use where machines can not be deployed due to site condition) |
| 2 | Excavation in Hard Rock - Excavation in Hard Rock (blasting prohibited) Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 m and lead upto 200 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5 (A) Manual Means |
| 3 | Excavation for Structures - Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. II Ordinary rock (not requiring blasting) Upto 3 m depth |
| 4 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 - A With crushed Stone - I P.C.C grade M 10 - Nominal mix 1:3:6 |
| 5 | Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 - III Random rubble masonry - In 1:3 cement mortar |
| 6 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 7 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 |
| 8 | Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204 |
| 9 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 - A With crushed Stone - III P.C.C Grade M20 - Nominal mix (1:2:4) |
| 10 | Supply of Mechanically Woven Double Twisted Hexagonal Shaped Wire Mesh 1m High Gabion Boxes as per IS 16014, MORTH 2013 Boxes as per is specification Clause 2500, of required sizes, Mesh Type , (Zn(..%) + Al (.. %)alloy)+ Polymer (PVC) coated , Mesh Wire dia. - (ID/OD), mechanically edged / selvedged, with partitions at every 1m interval and tying with lacing wire of dia -mm (ID/OD), supplied @3% by weight of gabion boxes (excluding transportation), as per detailed specification conforming to codes in vogue all complete as per directions of engineer in-charge. |
| 11 | Providing and laying one layer of Non-Woven geotextile of minimum mass per unit area of 280gms/sqm having minimum roll width of 5.0m treated with carbon black with physical properties as given in clause no 702.2.3. over 25mm thick compacted sand layer on a prepared subgrade as a filter media with necessary overlaps as per drawing and technical specification and as directed by the Engineer in charge complete. |
| 12 | Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 - ii Sandy material |
| 13 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 - A With crushed Stone - IV R.C.C Grade M20 - Bottom Slab - Stem |
| 14 | Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA Steel/Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 - 12 mm dia bar as Top & Bottom. In Toe @ 110 c/c / 10 mm dia bar as Dist. In Toe @ 150 c/c / 16 mm dia bar as vert. @ 120 c/c / 10 mm dia bar as dist. @ 140 c/c |
| 15 | Supply and installation of BIS Marked Mechanically Woven double Twisted Hexagonal Shaped Wire Mesh Netting of Mesh Type 10x12 with D=100mm tolerance of +-2%. Zn + PVC Coated, mesh wire dia 2.7/3.7mm (ID/OD), mechanically edged/ selveged with galvanisation as per EN 10223-3, and shall have minimum 10 numbers of mesh opening per meter of mesh perpendicular to 107 twist, lacing with wire of diameter 2.2/3.2 mm (ID/OD) at easily accesible location including top and bottom with all leads and lifts, manpower and machinery, material, labour etc. complete and as directed by engineer in-charge. |
| 16 | Supply of High tensile rope net systems having rope diameter of 10mm (steel core) with tensile strength of rope 1960 N/mm2 with the intersection of joints secured by a high resistance clip with dimension of 40mmx40mm confirming to EN 10025, the clip shall be heavily galvanised for corrosion protection confirming to EN 2081. This clip shall be capable of bearing a tear load of not less than 11KN and mesh opening of 300x300mm. The system shall include top and bottom support rope, lacing wire or rope required to connect the panels and all accessories such as U 108 clamps, thimbles as shown in drawings and as per technical specification. It shall have a min. tensile strength of 220 (+/-10 )kN/m and a min, ultimate punch load of 461 (+/-10)kN at easily accessible location including top and bottom with all leads and lifts, manpower and machinery, material, labour etc. complete and as directed by engineer-in-charge. |
| 17 | Supply and installation of biodegradable coir mat (450 GSM) with seeds embedded as per IRC. |
| 18 | Geo Bags - Supplying, filling and laying in loose with Geo-textile bags of Type-A (1.30m x 0.70m) made of Geo textile non woven fabric sheets of 400 GSM manufactured from polyster/ polypropylene conforming to relevant ISO standard filled with specified sand/ silt from flood plain or adjacent char within a distance of 90 m of the work site including excavation, filling Geo bags with sand weighing 126.00 kg after filling, stitching the mouth of the filled bags with polypropylene or polyster complete as per technical specifications and as directed. (b) Without Boat |
| 19 | Supply, Stitching and Laying of Non wooven Geo textile Fabric sheet of 400 gsm |
| 20 | RCC Guard Post - Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to 20mm size) of cement concrete and required reinforcement tied in position with annealed black wire including centering, moulding the top, curing including painting concrete surfaces in 23cm strips upto 0.75m from the top alternately in black and white and having 2 nos. reflective band of desired shade etc. complete as per design and as directed. (b) 15 cm dia. RCC guard post with reinforcement of 4nos. 12mm dia TMT main steel bars and 6mm TMT/ MS stirrups at 15cm c/c. |
| 21 | Excavation for structure - Earthwork in excavation for foundation of structure as per drawing and technical specifications, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottoms and back filling with approved material. (1) Ordinary soil (1) Depth up to 3m ( with dewatering ) |
| 22 | Brick masonry work in 1:4 in foundation of Head Walls complete excluding pointing and plastering, as per drawing and technical specification |
| 23 | Laying 1St. Class Bedding on well graded sand, Moorum as per Technical Specification clause 1105 - ( ii ) With Granular Materials |
| 24 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of grannular material in double row including fixing coller with cement morter 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets as per Clause 1106. Reinforced cement concrete pipe NP3 - B 600 mm dia |
| 25 | Bedding of pipe - Type B (First Class) Bedding - Laying (First Class) bedding on well compacted sand, moorum as per Clause 1105 (ii) |
| 26 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 - With crushed Stone - P.C.C grade M 15 - Nominal mix (1:2.5:5) |
| 27 | Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row - Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. - 1000 mm dia |
| 28 | Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 - I. Sand filling |
| 29 | Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement) (SAI/BISCON/THERMAX or equivalent) in foundation complete as per drawings and technical specification Clauses 1000 and 1202 |
| 30 | Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement) (SAI/BISCON/THERMAX or equivalent) in substructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 |
| 31 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 805, 806, 807, 1010, 1202 and 1204 - (A) With crushed Stone - (III) RCC Grade M-20 - (i) For height upto 5 m |
| 32 | Providing pressure relief pipes 100 mm dia in bottom slab of box cell on a filter media base of 500 mm x 500 mm as per drawing and technical specification Clause 1205.5.7 |
| 33 | Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3 |
| 34 | Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and technical specifications Clause 1301 |
| 35 | Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications |
| 36 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 - A With Natural gravel - I. P.C.C grade M 10 - (i) Nominal mix 1:3:6 |
| 37 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 - A With Natural gravel - IV. R.C.C grade M 20 |
| 38 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - A With crushed Stone - IV. R.C.C. grade M 25 - (i) For height up to 5m |
| 39 | Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications - (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent) |
| 40 | Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications - (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent) |
| 41 | Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face. Complete as per drawing |
| 42 | Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification - A Granular material |
| 43 | Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 - A With crushed Stone - II R.C.C M25 - (a) Height up to 5m |
| 44 | Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications - (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam |
| 45 | Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 |
| 46 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 |
| 47 | Drainage Spouts complete as per drawing and Technical specification |
| 48 | Laying brick soling layer on prepared sub-grade with brick on end edging according to lines, graded and cross-section shown on the drawing filling joints with sand and earth, spreading 25 mm thick layer of earth over brick soling, watering and rolling the same with three wheel road roller 80-100 kN as per Technical Specification Clause 412 |
| 49 | Clearing and Grubbing Road Land - Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (I) By Manual Means (a) In area of non thorny jungle |
| 50 | Dismantling of Cement Concrete Pavements as per Technical Specification Clause 202. - Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately |
| 51 | Construction of Embankment with Material Obtained from Roadway Cutting - Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 |
| 52 | Construction of Embankment with Material Obtained from Borrow Pits - Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (II) Private Land |
| 53 | Construction of Subgrade and Earthen Shoulders - Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (I) Private Land |
| 54 | Granular Sub-base with Well Graded Material (Table 400.1) - Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (A) By Mix in Place Method (II) For Grading II Material |
| 55 | Water Bound Macadam Sub-base/base - (III) WBM Grading 3 Using stone screening Type-B 11.2 mm for Gr.III - Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By Manual Means |
| 56 | Inter locking concrete Block pavement - (I) Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification (I) (a) clause 1504 complete including carriage. a) Including Edge block/ Edge restraints |
| 57 | Traffic Signs - (A) Retro-reflectorised Traffic Signs (I) Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 - (ii) 600mm equilateral triangle |
| 58 | Traffic Signs - (A) Retro-reflectorised Traffic Signs (I) Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 - (iii) 600mm circular |
| 59 | Traffic Signs - (A) Retro-reflectorised Traffic Signs (I) Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 - (iv) 800mm x 600mm rectangular |
| 60 | Traffic Signs - (A) Retro-reflectorised Traffic Signs (I) Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 - (vii) 900mm side octagon |
| 61 | Kilometre Stone - Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 - (i) 5th Kilometre Stone (precast) |
| 62 | Kilometre Stone - Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 - (ii) Ordinary Kilometer Stone (Precast) |
| 63 | Kilometre Stone - Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 - (iii) 200 m stone (precast) |
| 64 | Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 65 | Tree Plantation - Planting of Trees and their Maintenance for three Year (Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge mannure, planting the saplings, backfilling the trenches, watering, fixing the tree guatrd and maintaining the plants for three year. |
| 66 | Providing Non-Structural Measures (like Training, conducting Awareness Program etc.) and as directed by the department Please Enable Macros to View BoQ information |
| 67 | Providing Non-Structural Measures (like Training, conducting Awareness Program etc.) and as directed by the department Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysDec 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender