Tender For Annual Plan-Ekm Dp - Keezhmad Div - Providing Drinking Water Facilities To South Ezhipram Hs In Vazhakkulam Gp.-Providing Water Pump Set For Kwa Ground Water Tank-General Electrical Work
Tender Value
2.55 Lakhs
Estimated cost
Bid Submission
27 Nov 2026
5 days left
EMD
6398
Bank guarantee accepted
Document Fee
565
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Annual Plan-Ekm Dp - Keezhmad Div - Providing Drinking Water Facilities To South Ezhipram Hs In Vazhakkulam Gp.-Providing Water Pump Set For Kwa Ground Water Tank-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | Water pump for KWA water storage tank |
| 2 | OD280377/2026-2027:SITC of Single phase, mono block surface pump 1.5 HP, 180 to 240 Volts single phase, suction/delivery size 50/40 mm, Head 15 to 26 meters, Discharge 1.6 to 2.3 lps, pump/motor body Cast iron, Mechanical seal, carbon steel shaft Kirloskar KDS-1.525+ or equivalent, including mounting of the pump set on existing concrete base using M16 SS bolts, providing electrical conectios from existing wall JB using 3 core 2.5 sqmm copper flexible cable laid through surface clamped 1 inch PVC pipe. |
| 3 | OD280881/2026-2027:Supply of 40 mm PVC Tank MTA Adaptor Set |
| 4 | OD280882/2026-2027:Supply of 40 mm PVC Ball Valve |
| 5 | OD280883/2026-2027:Supply of 50 mm MTA (Male Threaded Adapter) |
| 6 | OD280884/2026-2027:Supply of 40 mm MTA (Male Threaded Adapter) |
| 7 | OD280885/2026-2027:Supply of 40 mm PVC Tee |
| 8 | OD280886/2026-2027:Supply of 40 mm PVC Bend (90°) |
| 9 | OD280887/2026-2027:Supply of 40 mm PVC Coupling |
| 10 | OD280888/2026-2027:Supply of 50×40 mm PVC Reducer |
| 11 | OD281030/2026-2027:Supply of 40 mm PVC Pipe, Sch 40 |
| 12 | OD281016/2026-2027:Plumbing charges for laying 40mm PVC pipe, partially under ground including cost of solvents, teflon tape etc., fitment of PVC fittings, valves, adaptors etc, in line, connections to tank and pump. |
| 13 | OD280598/2026-2027:SITC of automatic water level controller with two float switch-based level sensors for suction and delivery tanks. |
| 14 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 15 | 14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels. |
| 16 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 17 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 18 | 90.6.5.4:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 1.50 sq mm |
| 19 | 90.12.5.1:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 4 sq mm |
| 20 | 90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp |
| 21 | OD281319/2026-2027:Supply of 32 mm dia G.I. Pipe (light class) |
| 22 | 1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm |
| 23 | 1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm |
| 24 | 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm |
| 25 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 26 | 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) |
| 27 | OD281347/2026-2027:Supply and providing 25x3 mm brass nut and bolt etc. as required. |
| 28 | 90.14.28.1:S & F Motor starters of the following ratingsSingle phase DOL starters for 0.25HP to 3HP motor |
| 29 | OD281352/2026-2027:Supply and install SMC junction box Sintax GS-JB-1414-NF or equivalent to existing metal/cement surface |
| 30 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 31 | Water pump for open well |
| 32 | OD284782/2026-2027:Supply and fabrication conveyance and installation of angle iron framework for mounting pump underwater, including painting. |
| 33 | OD293284/2026-2027:Supply of open well vertical submersible pump, 2 Hp, 3 Phase, 415 Volts, 50 Hz, Head 24 to 54 meters, Delivery 80 to 220 lpm, Deccan model/stage 21D6/6, Product code: 6CCMP20155RCS06 |
| 34 | 90.14.28.14:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,TPMCB for three phase 5 to 7.5HP submersible motor pumps (DOL) |
| 35 | OD294313/2026-2027:Supply of 4 SQ.MM BMI 3 CORE SUBMERSIBLE FLAT CABLE |
| 36 | OD294314/2026-2027:Supply of ROPE AQUATEX PRIME 12MM PP ROPE BLUE |
| 37 | OD294283/2026-2027:Supply of GI Hex nipple 2 inches |
| 38 | OD293519/2026-2027:Supply of MS Sheet cutting (Hole patta, Square plate) |
| 39 | OD293520/2026-2027:Supply of Hose collar SS HD 2 inches |
| 40 | OD293521/2026-2027:Supply of Flange GI 2 inches |
| 41 | OD293522/2026-2027:Supply of Check valve brass Flap ORBIT 2 inch |
| 42 | OD293523/2026-2027:Supply of Teflon tape |
| 43 | OD293524/2026-2027:Supply of Shellac 30 ml |
| 44 | OD293525/2026-2027:Supply of Hose clip SS LD 2.5 |
| 45 | OD293526/2026-2027:Supply of HDPE pipe 63 mm 10 Kg (P100)2 inches |
| 46 | OD293527/2026-2027:Supply of Hose Collar SS Hook type 2 inch |
| 47 | OD293310/2026-2027:Installation of 2 HP 3 phase open well submersible pump including erection of pump in well, plumbing pipes and other fittings, including electrical connections, testing and coomissioning. |
| 48 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 49 | 90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 50 | 90.12.39.33:Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm |
| 51 | 90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 52 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 53 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 54 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 55 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 56 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 57 | 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 58 | 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm |
| 59 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 60 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 61 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 62 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 63 | 90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point |
| 64 | 90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point |
| 65 | 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 66 | OD293413/2026-2027:Fabricate, supply and erect mounting bracket for LED streetlight fabricated using 32 mm heavy GI pipe including double coating with primer and enamel paint, using necessary fasteners to the existing wall or metal structure |
| 67 | OD293418/2026-2027:Supply, installation, testing and commissioning of prewired LED Bulkhead light fitting, IP 65, 230VAC, 10 Watts, PVC housing with polycarbonate diffuser Philips WT110W LED10S or equivalent, with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required. |
| 68 | OD294284/2026-2027:Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(with charcoal/ coke and salt) as required |
| 69 | 5.7:Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 70 | OD294285/2026-2027:Supply and providing 25x3 mm brass nut and bolt etc. as required. |
| 71 | OD293419/2026-2027:Supply and providing LED bulb 9/12watts Philips/equivalent |
| 72 | Electrification for water filters |
| 73 | 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm |
| 74 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 75 | 1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) |
| 76 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 77 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 78 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 79 | 14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels. |
| 80 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysNov 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender