Name of Work:- Rate contract for Day to Day Electrical work at Psychiatric Hospital Jaipur
Sl. No. Item Description
1Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminum round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required.
2Short point (up to 3 mtr.)
3Medium point (up to 6 mtr.)
4Long point (up to 10 mtr.)
5Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal,2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required.
6Short point (up to 3 mtr.)
7Medium point (up to 6 mtr.)
8Long point (up to 10 mtr.)
9Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.
10On board
11S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required.
1220 mm
1325 mm
1432 mm
1540 mm
1650 mm
17Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 1.2 mm thick Hot dipped Galavanized MS box with earth terminal, 6 A switch, 3 pin ceiling rose/holder / 3 way connector , 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
18Short point (up to 3 mtr.)
19Medium point (up to 6 mtr.)
20Long point (up to 10 mtr.)
21Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 2 Nos 1.2 mm thick Hot dipped Galavanized MS box with earth terminal, 2 Nos 6 A two way switch,3 pin ceiling rose / holder/ 3 way connector, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
22Short point (up to 3 mtr.)
23Medium point (up to 6 mtr.)
24Long point (up to 10 mtr..)
25Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, 1.2 mm thick Hot dipped Galavanized MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
26On board
27Short point (up to 3 mtr.)
28Medium point (up to 6 mtr.)
29Long point (up to 10 mtr..)
30S&F of following sizes of polypropelene corrugated flexible conduit including gland on both side of flexible conduit as required.
3116 mm OD
3220 mm OD
3325 mm OD
3432 mm OD
3540 mm OD
36Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal/Surface mounted UPVC molded modular box, 6 A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required.
37Short point (up to 3 mtr.)
38Medium point (up to 6 mtr.)
39Long point (up to 10 mtr.)
40Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, 2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required.
41Short point (up to 3 mtr.)
42Medium point (up to 6 mtr.)
43Long point (up to 10 mtr.)
44Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.
45On board
46S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required on surface including heavy duty saddles with base at spacing of 0.60 mtr. etc as required.
4720 mm
4825 mm
4932 mm
5040 mm
5150 mm
52Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot dipped Galvanized MS box with earth terminal of required size , 6 A switch, 3 pin ceiling rose/holder / 3 way connector , 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
53Short point (up to 3 mtr.)
54Medium point (up to 6 mtr.)
55Long point (up to 10 mtr.)
56Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos 1.2 mm thick Hot dipped Galvanized MS box with earth terminal of required size, 2 Nos 6 A two way switch,3 pin ceiling rose / holder/ 3 way connector, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
57Short point (up to 3 mtr.)
58Medium point (up to 6 mtr.)
59Long point (up to 10 mtr..)
60Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, 1.2 mm thick Hot dipped Galvanized MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
61On board
62Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked ( IS:14927 P - II ) uPVC trunking & it's accessories, Hot Dipped Galvanized Modular box 1.2 mm thick with earth terminal/ Surface mounted UPVC molded modular box, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose/holder /3 way Connector, screws, making connections, testing etc. as required.
63Short point (up to 3 mtr.)
64Medium point (up to 6 mtr.)
65Long point (up to 10 mtr.)
66Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) of approved make on surface ISI marked ( IS:14927 P - II ) uPVC trunking & it's accessories, 2 No. Hot Dipped Galvanized Modular box 1.2 mm thick with earth terminal/ 2 No. Surface mounted UPVC molded modular box, 2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder/3 way Connector , Modular face plate with grid plate, screws, making connections, testing etc. as required
67Short point (up to 3 mtr.)
68Medium point (up to 6 mtr.)
69Long point (up to 10 mtr..)
70Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked ( IS:14927 P - II ) uPVC trunking & it's accessories, Hot Dipped Galvanized Modular box 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, modular 6 A switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required
71On board
72Short point (up to 3 mtr.)
73Medium point (up to 6 mtr.)
74Long point (up to 10 mtr..)
75S&F following sizes of ISI marked ( IS:14927 P - II ) uPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners etc. as required.
7620 mm x 12 mm
7725 mm x 12 mm
7832 mm x 12 mm
7925 mm x 16 mm
8038 mm x 16 mm
8138 mm x 25 mm
8238 mm x 38 mm
8350 mm x 16 mm
8450 mm x 50 mm
8575 mm x 50 mm
8675 mm x 75 mm
87100 mm x 50 mm
88100 mm x 100 mm
89150 mm x 50 mm
90150 mm x 100 mm
91Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required.
921 x 1.5 sq.mm
932 x 1.5 sq.mm
943x 1.5 sq.mm
954 x 1.5 sq.mm
961 x 2.5 sq.mm
972 x 2.5 sq.mm
982 x 2.5 sq. mm. + 1x1.5sqmm
993 x 2.5 sq.mm
1004 x 2.5 sq.mm
1011 x 4.0 sq.mm
1022 x 4.0 sq.mm
1033 x 4 sq. mm.
1044 x 4.0 sq.mm
1052 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
1061 x 6.0 sq.mm
1072 x 6.0 sq.mm
1083 x 6.0 sq. mm.
1094 x 6.0 sq.mm
1102 x 6.0 sq. mm. + 1 x 2.5 sq. mm.
1112 x 6.0 sq. mm. + 1 x 4.0 sq. mm.
1121 x 10.0 sq.mm
1132 x 10.0 sq.mm
1144 x 10.0 sq.mm
1151 x 16.0 sq.mm
1162 x 16.0 sq.mm
1174 x 16.0 sq.mm
118Supplying and Laying coaxial cable 75 ohm impedance with foam PE insulated solid bare copper inner conductor, and Ist outer conductor of bonded alum. tape and second outer conductor of alum. alloy braid in existing surface or recessed conduit/casing capping including making connections as required.
119RG - 6
120RG -11
121Supplying and Laying PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 & confirming to TEC specification GR / WIR/06-03 March 2002 in existing surface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required.
1222 pair
1234 pair
1245 pair
12510 pair
12620 pair
12750 pair
128100 pair
129200 pair
130Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specifications GR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size.
1315 pair
13210 pair
13320 pair
13450 pair
135100 pair
136200 pair
137Supply and Laying of PE Insulated jelly filled Armoured Telephone Cable. with 0.6 mm thick Solid Annealed Bare Copper Conductor and confirming to TEC specifications confirming. to DOT GR/CUG-01/Aug.2003 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size.
1385 pair
13910 pair
14020 pair
14150 pair
142100 pair
143200 pair
144Supply & laying service connection with ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required.
1452.5sq.mm
1464.0 sq.mm
1476.0 sq.mm
14810.0 sq.mm
149Supply and Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required.
1501.5 Sq.mm 3 core flat / Round
1512.5 Sq.mm 3 core flat / Round
1524.0 Sq.mm 3 core flat / Round
1536.0 Sq.mm 3 core flat / Round
15410.0 Sq.mm 3 core flat / Round
15516.0 Sq.mm 3 core flat / Round
156Supply and laying following size twin parallel type Speaker cables made with multi wire, bright annealed flexible bare electrolytic grade copper conductor, insulated with specially formulated transparent grade PVC compound, red strip for identification in existing conduit etc. as required.
1570.75 sq.mm
1581.0 Sq. mm
1591.5 Sq.mm
1602.5 Sq.mm
161Supply and laying speaker cable of following size 2 core twin twisted multi stranded electrolytic grade copper conductor, overall PVC insulated and armoured cable (Blue colour) on surface/ above false ceiling including cost of GI spacers, saddles etc. as required.
1620.75 sq.mm
1631.0 Sq. mm
1641.5 Sq.mm
1652.5 Sq.mm
166Supply and laying PVC Insulated and PVC Round Sheathed Multi Core copper conductor (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing pipe / open trench / Cable tray / on surface including making connection etc. as required.
1671.5 sq.mm x 3 core
1681.5 sq.mm x 4 core
1691.5 sq.mm x 6 core
1701.5 sq.mm x 8 core
1712.5 sq.mm x 3 core
1722.5 sq.mm x 4 core
1732.5 sq.mm x 6 core
1742.5 sq.mm x 8 core
1754.0 sq.mm x 3 core
1764.0 sq.mm x 4 core
1774.0 sq.mm x 6 core
178P & F 1.2 mm thick Hot dipped galvanized boxes with brass earthing terminal of following sizes (nominal size) in recessed/surface as required.
17975mm x 75mm x 60mm
180100mm x 100mm x 60mm
181150mm x 75mm x 60mm
182175mm x 100mm x 60mm
183150mm x 150mm x 60mm
184225mm x 100mm x 60mm
185200mm x 150mm x 60mm
186200mm x 125mm x 75mm
187200mm x 250mm x 75mm
188200mm x 250mm x 100mm
189250mm x 300mm x 75mm
190250mm x 300mm x 100mm
191300mm x 375mm x 75mm
192300mm x 375mm x 100mm
193250mm x 100mm x 60mm
194300mm x 100mm x 60mm
195300mm x 300mm x 75mm
196P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required.
1973.0 mm thick
1985.0 mm thick
1996.0 mm thick
2008.0 mm thick
20110.0 mm thick
20216.0 mm thick
20320.0 mm thick
204P & Fixing Powder coated CRCA sheet enclosures on existing Structure by means of nuts and bolts and making holes , Din rail etc. as required.
2051.2 mm thick
2061.6 mm thick
2072.0 mm thick
2082.5 mm thick
209P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.
21075 mm dia
211100 mm dia.
212P & F P.V.C. sheet 2.0 mm thick of following size Including screws, cup washer as required.
21375 mm dia.
214100 mm dia.
215P & F Aluminium sheet 1.0 m thick of following size dia. Including screws, cup washer as required.
21675 mm dia.
217100 mm dia.
218P & F 1.2 mm thick M.S. Recessed concealed box, round of size 150 mm dia, depth 100 mm complete as required.
219Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required.
220Single pole MCB (With B / C curve tripping characteristics)
2210.5 A to 5 A rating
2226 A to 32 A rating
22340 A rating
22450/63 A rating
22580 A rating
226100 A rating
227125 A rating
228Double pole MCB (With B / C curve tripping characteristics)
2290.5 A to 5 A rating
2306 A to 32 A rating
23140 A rating
23250/63 A rating
23380 A rating
234100 A rating
235125 A rating
236Triple pole MCB (With B / C curve tripping characteristics)
2370.5A to 5 A rating
2386 A to 32 A rating
23940 A rating
24050/63 A rating
24180 A rating
242100 A rating
243125 A rating
244Four pole MCB (With B / C curve tripping characteristics)
2450.5A to 5 A rating
2466 A to 32 A rating
24740 A rating
24850/63 A rating
24980 A rating
250100 A rating
251125 A rating
252Triple pole MCB (With D curve tripping Characteristics)
2530.5 A to 5 A rating
2546 A to 32 A rating
25540 A rating
25650/63 A rating
257Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 25 sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required.
258Two pole 30 mA sensitivity
2596A-32 A rating
26040 A rating
26163 A rating
262Two pole 100/300mA sensitivity
2636A-32 A rating
26440 A rating
26563 A rating
266Four pole 30 mA sensitivity
2676A-32 A rating
26840 A rating
26963 A rating
270Four pole 100/300 mA sensitivity
2716A-32 A rating
27240 A rating
27363 A rating
274P&F 240/415 V AC Change Over Miniature circuit breaker with three positions (I-O-II) which allows supply change over from one source to second source & vice- versa, conforming to IS/ IEC 60947-3 in existing board/sheets including making connections, testing etc. as required.
275Double Pole
27625 Amp, 2 Module
27740 Amp, 2 Module
27863 Amp,3 Module
279FourPole
28040 Amp, 4 Module
28163 Amp, 6 Module
282Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating and 5000 for 100 A rating and minimum phase termination capacity of 25 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required.
283Two pole 30 mA sensitivity
28416/25 A rating
28532/40 A rating
28663A rating
287100 A rating
288Two pole 100/300mA sensitivity
28916/25 A rating
29040 A rating
29163 A rating
292Four pole 30 mA sensitivity
29325 A rating
29440 A rating
29563 A rating
296100 A rating
297Four pole 100/300 mA sensitivity
29825 A rating
29940 A rating
30063 A rating
301100 A rating
302Providing & Fixing of din rail mounting surge protection device confirming to IEC 61643-11 for Type 1 + 2 protection and Maximum discharge current 50 kA with following configuration in existing distribution board / sheet including making connections, testing etc. as required.
3031P + N
3043P + N
305Providing & Fixing of din rail mounting contactor and accessories confirming to IEC 61095 with following description and configuration in existing distribution board / sheet including making connections, testing etc. as required.
306Modular contactor 25A - 1NO
307Modular contactor 25A - 2NO
308Modular contactor 40A - 2NO
309Modular contactor 40A - 3NO
310Modular contactor 40A - 4NO
311Modular contactor 63A - 2NO + 2 NC
312Modular contactor 63A - 3NO
313Modular contactor 63A - 4NO
314Auxilary contact, 2 NO
315Auxilary contact, 1 NO + 1 NC
316Under voltage Release
317Shunt Trip Release
318Providing & Fixing of din rail mounting LED Indicating Lights with following description and configuration in existing distribution board / sheet including making connections, testing etc. as required.
319Red / Yellow / Blue / Green
320Red-yellow-Blue
321Providing & Fixing of Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. complete with din rail making internal DB terminations with copper lugs, detachable gland plate, including making connections, testing etc. as required.
322Suitable for Two / Three / Four module for MCB
323Suitable for Six / Eight module for MCB/ RCCB
324Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (Metal / Glazed / Acrylic) Distribution board with Metal end box made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, complete with 100 amp. insulated copper bus bar/shorting link , brass neutral link with shrouds, brass earth link , door earthing arrangement, color coded interconnecting wire set of minimum 10.0 sqmm size and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required.
325Metal door (single phase) IK-09 and IP-43 with Metal end box
3264 Way
3276 Way
3288 Way
32912 Way
33016 Way
331Glazed / Acrylic door (single phase) IK-09 and IP-43 with Metal end box
3324 Way
3336 Way
3348 Way
33512 Way
33616 Way
337Metal door (Three phase) IK-09 and IP-43 with Metal end box
3384 Way (8 incomer + 12 Outgoing)
3396 Way (8 incomer + 18 Outgoing)
3408 Way (8 incomer + 24 Outgoing)
34112 Way (8 incomer + 36 Outgoing)
342Glazed / Acrylic door (Three phase) IK-09 and IP-43 with Metal end box
3434 Way (8 incomer + 12 Outgoing)
3446 Way (8 incomer + 18 Outgoing)
3458 Way (8 incomer + 24 Outgoing)
34612 Way (8 incomer + 36 Outgoing)
347Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box
3484Way {8 Incomer + 6 Sub Incomer (2+2+2) + 12 out going }
3496Way {8 Incomer + 6 Sub Incomer (2+2+2) + 18 out going }
3508Way. {8 Incomer + 6 Sub Incomer (2+2+2) + 24 out going }
35112 Way {8 Incomer + 6 Sub Incomer (2+2+2) + 36 out going }
352Providing & Fixing of Recessed/surface mounting heavy duty Flexi / Row type Distribution board with Metal end box made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3 complete with 100 Amp. copper shorting link , brass neutral link with shrouds, brass earth link , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules detachable gland plate, including making connections, testing etc. as required.
353Double door IK-09 & IP-43 with metal End box
3544 Row 32 Module(8 module per row)
3554 Row 40 Module(10 module per row)
3564 Row 56 Module(14 module per row)
3573 Row 42 Module(14 module per row) with provision of 160 Amp. MCCB
358Glazed / Acrylic door IK-09 & IP-43 with Metal End Box
3594 Row 32 Module(8 module per row)
3604 Row 40 Module(10 module per row)
3614 Row 56 Module(14 module per row)
362P&F metal clad / Polyamide industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. (without MCB) including making connections, testing etc.as required.
36320 amp, (2P + E), 1 Module
36420 amp, (2P + E), 2 Module
36520 amp, (2P + E), 3 Module
36632 amp, (3P + E), 3 Module
36732 amp, (3P + N + E) 8 Module (with Polyamide Plug & Socket)
36863 amp, (3P + N+ E), 8 Module (with Polyamide Plug & Socket)
369P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd.
370IP -67, IK - 09 Panel mounted socket
37116 A (2P+E)
37232 A (2P+E)
37332 A (3P+N+E)
37463 A (3P+N+E)
375IP -67, IK-09 Surface/Wall mounted socket
37616 A (2P+E)
37732 A (2P+E)
37832 A (3P+N+E)
37963 A (3P+N+E)
380IP -66, Surface/Wall mounted Interlocked switched socket Outlet with Provision of MCB
38116 A (2P+E) 250 V
38232 A (2P+E), 250 V
38332 A (3P+E), 415 V
38432 A (3P+N +E), 415 V
38563 A (3P+N +E), 415 V
386IP - 67 Plug top
38716 A (2P+E)
38832 A (2P+E)
38932 A (3P+E)
39032 A (3P+N+E)
39163 A (3P+N+E)
392Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for MCB / RCCB/ RCBO up to 63 Amp and SP / TP MCB upto 32 Amp. as outgoing ,made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3 complete with insulated 100 A rating copper bus bar, brass neutral bars with shrouds, brass earth bar , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required.
393Double door IK-09 & IP-43 with Metal end box
3944 Way (8 Incomer +12 Outgoing)
3956 Way (8 Incomer +18 Outgoing)
3968 Way (8 Incomer +24 Outgoing)
39712 Way (8 Incomer + 36 Outgoing)
398Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB up to 63 Amps. as outgoing ,made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. complete with insulated 125/160/200/250 Amp. copper bus bar, brass neutral bars with shrouds, brass earth bar , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required.
399Double door IP-43 & IK-09 with Provision of Incomer MCCB up to 125 A Rating with Metal end box
4004 Way
4016 Way
4028 Way
40312 Way
404Double door IP-43 & IK-09 with Provision of Incomer MCCB 160 A Rating with Metal End Box
4054 Way
4066 Way
4078 Way
40812 Way
409Double door IP-43 & IK-09 with Provision of Incomer MCCB 200/250 A Rating with metal End Box
4104 Way
4116 Way
4128 Way
41312 Way
414P & F Surface mounting IP-65, IK-09 Class-II self extinguishing insulating material weather proof cabinets confirming to EN60439-3 with IP-65 Key lock, fully reversible door and cabinet, removable chasis and face plates, of following size.
4153/4 module
4166 module
4178 module
4181 row 12 module
4192 row 24 module
4203 row 36 module
421P & F ISI marked (IS:3854) 6 amp. flush type non modular switch with CM/L no. printed and made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required.
422P & F ISI marked (IS :3854) 16 amp. flush type non modular switch CM/L no. printed and made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required.
423Providing & Fixing of 6 amp. Combined flush type non modular socket and switch set made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required.
424Providing & Fixing of 16 amp. Combined flush type non modular socket and switch set with indicator and fuse set, made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required.
425Providing & Fixing of ISI marked (IS :3854) non modular 6A bell push surface type CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required.
426Providing & Fixing of ISI marked (IS :3854) twin control non modular 6A switch surface type, CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required.
427Providing & Fixing of ISI marked (IS :3854) non modular 6A bell push flush type CM/L no. printed and made out from industrial grade Polycarbonate materialincluding cutting hole in tile and making connection testing etc. as required.
428Providing & Fixing of ISI marked (IS :3854) twin control non modular 6A switch flush type CM/L no. printed , made out from industrial grade Polycarbonate material, including cutting hole in tile and making connection testing etc. as required.
429Providing & Fixing of non modular 6A hanging bell push/one way switch made out from industrial grade Polycarbonate material including making connection testing etc. as required.
430Providing & Fixing of IS:1293 marked of 3 pin 6 amp. flush type non modular socket CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.
431Providing & Fixing of IS:1293 3/6 pin 16 amp flush type non modular socket CM/L no. printed and made out from Industrial grade Polycarbonate material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.
432Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required.
433Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required.
434Providing & Fixing of ISI marked (IS:1293) 6 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required.
435Providing & Fixing of ISI marked (IS:1293) 16 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required.
436Providing & Fixing of flush type non modular 2 pin telephone socket with plug top made out from industrial grade Polycarbonate material, brass terminals including making connection testing etc. as required.
437Providing & Fixing of flush type non modular single line telephone jack made out from industrial grade Polycarbonate material, including making connection testing etc. as required.
438Providing & Fixing of flush type non modular double line telephone jack made out from industrial grade Polycarbonate materialincluding making connection testing etc. as required.
439Providing & Fixing of flush type non modular coaxial T.V. socket made out from industrial grade Polycarbonate material,including making connection testing etc. as required.
440Providing & Fixing of IS 11037 marked non modular socket size flush type 100 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required.
441P & F ISI marked 32 A D.P. switch with fuse and indicating lamp including making connection testing etc. as required.
442Providing & Fixing of ISI marked (IS:302) gong bell with CM/L no. printed including making connection testing etc. as required.
443Providing & Fixing of Non Modular Neon Light including making connection testing etc. as required.
444Providing & Fixing of single / multi tone electronic call bell / remote bell including making connection testing etc. as required.
445Providing & Fixing of ISI marked (IS:302) ding dong/musical chime bell including making connection testing etc. as required.
446Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant virgin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including making connections, testing etc as required.
4476 A one way switch
4486 A two way switch
4496 A bell push
45010 A one way switch
45110 A two way switch
45216 A one way switch 1M
45320 A one way switch 1M
45420 A one way switch 2M
45516 Amp. 2 Module switch With Led Indicator
45632 Amp. 2 Module switch With Led Indicator
457Providing & Fixing of IS:1293 marked modular type lockable feature socket with CM/L no. printed duly made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required.
4586 A 3 pin shuttered socket
4596/16 A shuttered socket
46013 A flat pin international socket (Non ISI)
461Providing & Fixing of modular type 100W Step Fan regulator duly ISI marked (IS 11037) with CM/L no. printed made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including making connections, testing etc as required.
4625 step fan regulator 2 Module
463Providing & Fixing of 3 M Key card switch with Load capacity 20 amp, Off time delay 30 Sec. made out of unbreakable and fire retardant virgin poly carbonate, including making connections, testing etc as required.
464Providing & Fixing of following modular accessories, made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required.
465RJ-11 telephone jack single line
466RJ-11 telephone jack Double line
467USB Charger 2 A - 1 M with BIS mark
468RJ-45, Cat 6 computer jack with shutter
469T.V. coaxial socket
470Blanking plate
47125 Amp. 2 Module Motor Starter with on / off Push button
472LED Skirting /Foot Light 2 Module
473Electronic Chime/Buzzer 2M
474Modular MCB 6 A to 32 A SP
475Modular MCB 6 A to 32 A DP
476Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.
4771/2 Module
4783 Module
4794 Module
4805 Module
4816 Module
4828 Module
48310 Module
48412 Module
48516/18 Module
486Providing & Fixing of following size cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.
4871/2 Module
4883 Module
4894 Module
4905 Module
4916 Module
4928 Module
49310 Module
49412 Module
49516/18 Module
496Providing & Fixing of Hot dipped Galvanized metal box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.
4971-2 Module
4983 Module
4994-5 Module
5006-8 Module
50110-12 Module
50216/18 Module
503Providing & Fixing of Wiring Accessories OEM fabricated following size virgin material UPVC modular boxes on surface suitable for modular accessories as required.
5041-2 Module
5053 Module
5064/5 Module
5076 / 8 module
50810 / 12 module
50916/18 module
510Providing & Fixing of Multiple socket with surge and spikes protection cartridge not less then 5 KV with minimum four nos. universal 6 A sockets, one 6 A switch and 3 pin company fitted plug top and 3 core multistrand copper lead minimum 1.5 mtr. including making connection etc as required.
511Providing & Fixing of DLP PVC adaptable trunking system for cable management including finishing accessories like corners, tees, adjustable angles, junction etc. as required . The trunking system shall have adaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. OEM have to submit NABL accrediated /CPET lab test reports /EN 50085-2-1 complaince certificate.
51280mm x 50mm
513100/105mm x 50mm
514150/160mm x 50mm
515195/200mm x 50mm
516Providing and fixing of power plug point with non modular accessories with Galvanized box of 1.2 mm thick with earth terminal with suitable size 3.0 mm thick phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required.
517Supplying and fixing of power plug point with Modular accessories on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required.
518P & F Krone module with base frame in the recess / surface made out of 1.2 mm thick sheet steel box, front openable, having locking arrangements duly powder coated ,including dressing, ferruling and punching of telephone cable with krone tool etc. as required.
51910 Pairs
52020 Pairs
52150 Pairs
522100 Pairs
523200 Pairs
524P & F Portable Residual Current Device (PRCD) 3 pin plug top 16 A, 30 mA sensitivity. Plug should have feature of power indicator, test button and reset function etc. as required.
525SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-
526(a) Thickness of CRCA sheet shall not be less than 1.6 mm upto 450 mm length/ width of any compartment and be 2.0 mm above 450 mm, load bearing structure shall be 2.0 mm thick sheet supported by base M.S. channel if required, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided
527(b) complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side(Inner & Outer side) of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.
528[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )
529(d) Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.
530(e) All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.
531(f) Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )
532(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.
533(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI type Test certificates for Temp. rise test, Short circuit test for 50 kA and IP test is to be submitted)
534Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator, with short circuit withstand capacity of 31 MVA for 1 Sec. , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves.
535Electrolytic grade Aluminium bus bar 6010 grade
536Providing & Fixing of IS: 1248(part-1) 2003 confirming Moving Iron panel meter, 90 degree Analog type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter of class 1.0 accuracy of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.
537Voltmeter ( 0 to 500V )
538Ammeter (Direct Reading / CT Operated)
539Providing & Fixing of IS: 13875 & IEC :61326/IEC:62053-22 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT opertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.
540Single Phase Ammeter
541Single Phase Voltmeter
542Three phase Ammeter with Inbuilt Selector Switch
543Three phase Voltmeter with Inbuilt Selector Switch
544Three phase KWH Meter
545Three phase KWH Meter Dual Source
546Frequency Meter
547Three phase AMP+HZ+PF+KW+KVA+KVAR+T.ENERGY+THD-I, THD-V & RUN HRS Meter
548Three phase AMP + HZ + PF + KW + KVA + KVAR + KVARH+KWH+DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS Meter
549Three phase with universal Auxiliary supply + AMP + HZ + PF + KW + KVA + KVAR + KVARH + KWH + DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485 Meter
550Providing & Fixing of Current Transformer confirming IS 2705-I (1992) with secondary terminal and shorting Block , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required .
551Ring type tape wound CT
552C T Class 1, Ratio up to 150/5, Burden 5 VA
553C T Class 1, Ratio 200/5 to 600/5, Burden 10 VA
554C T Class 1, Ratio 800/5 to 1200/5, Burden 15 VA
555C T Class 1, Ratio 1500/5 to 3000/5, Burden 15 VA
556Providing & Fixing of selector switch of 10 A for voltmeter using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range 25 degree C to 55 degree C, frequency upto 10 KHz. Switch life under standard operating conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required .
557Voltage Between Phases with OFF ( 4 Position )
558Voltage Between Phases & Individual Phases to Neutral with OFF ( 7 Position )
559Providing & Fixing of CT linked selector switch of 10 A for Ampere meter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range 25 degree C to 55 degree C, frequency upto 10 KHz. switch life under standard operating conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc. as required .
560Providing & Fixing of 10 A Cam operated rotary (Local- Remote, Auto - manual) switches on existing panel with 1 pole 2 way and off position using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required .
561Providing & Fixing of 25 A TNC ( Trip - neutal - close ) switch to control remotely on existing panel as required.
562Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 27 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required.
563Red/yellow/Green colour
564Blue / white Colour
565Providing & Fixing of flush head push button actuators IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 27 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, including connection etc. as required.
566Non luminous type
567Luminous type Red , Yellow, Green, Amber
568Luminous type Blue , white
569Providing & Fixing of Electrical insulating rubber matts confirming to IS: 15652 / 2006 with one side anti skid aberration marks and pasting the mat with synthetic rubber adhesive as required.
5703.3 KV, class A 2 mm thick with proof voltage 10 KV AC (rms) and Break Down Voltage 30 KV AC (rms)
57111 KV, Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage 45 KV AC (rms)
572Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor confirming to IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required.
5733 pole Power contactors with following AC 3 Rating
574Up to 12 Amp
57516 to 25 Amp
57632 Amp.
57740 Amp
57850 Amp
57970 Amp
58080 Amp
58195 Amp
582140 Amp
583185 Amp
584250 Amp
585300 Amp
586400 Amp
587550 Amp
588630 Amp
5894 pole Power contactors with following AC 1 Rating
59016 Amp.
59125/32 Amp.
59240 Amp
59350/55 Amp
59463 Amp
595100/105 Amp
596160 Amp
597200 Amp
598250 Amp
599325 Amp
600400 Amp
601500 Amp
602600 Amp
603700 Amp
604900 Amp
605P & F of Control relays (Auxiliary Contactor) for AC control standard. 24 V Coil 110, 240 V, 415 V, 50 Hz conforming to IS:13947-4-1/IEC:60947-4-1 with required NO & NC combination including making connections, testing etc. as required.
606P & F of Front / Side mounting Add on Auxiliary Contact Block with required NO & NC combination including making connections, testing etc. as required.
607Providing & Fixing of thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required.
608Up to 14 Amp
60914 to 23 Amp
61020 to 33 Amp
61124 to 40 Amp
61236 to 60 Amp
61345 to 75 Amp
61466 to 110 Amp
615P & F of 240 / 415 V Electronic ON - OFF Timer 3 -30 Sec / 12 - 120 Sec including making Connection etc. as required.
616Providing & Fixing of Electromechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required.
617One day reserve (Electromechanical type )
618One day & week reserve (digital type )
619Providing & Fixing of 110 - 240 V, AC, 1 ph. , 2 W Astronomical time switch with surge suppressor, memory card, Sunrise / Sunset selectable, software for programming including making connection, etc. as required.
620Providing & Fixing of IP54 direct or CT operated, 1x240 / 3x240 volts , 50 Hz static watt-hour meter (kwh) , having resolution 0.1 / 0.01 kwh , confirming to IS:13779/ IS:15959, LED indicators for tamper operation ( Reverse &/or earth connection) , pulsating LED indicator for meterology , LCD Display, cover plate for body and terminal sealing , push button for all standard parameters, including making connection ,testing etc. as required.
621up to 30 ampere single phase meter acc. Cl 1
62210 A to 60 ampere Single phase meter acc. Cl 1
6233ph, 4W KWh CT Operated Base mounting 240 V-/5A acc. Cl 0.5s
6243ph, 4W KWh Direct Base mounting 240 V 10-60 Amp acc. Cl 1
625P & F of Automatic Transfer Switch (ATS) confirming to IEC60947-6-1, Utilization cateogory AC-33B with OEM fabricated enclosure for automatic on load transfer between two source power supply of 415V through Solenoid/Motorised mechanism and integrated with three positions realize fast transfer within 180 ms (for solenoid) and within 2.6 sec.(for motorised). ATS shall have three postions (S1-OFF-S2) , Manual / Auto Override feature, The two sources can be isolated in the off position with a padlock. capability to expand with RS 485 communication module, which can ensure real-time transmission of communication data. ATS shall have automatic generator start & stop control function; Auxillary contacts to indicate mechanical positions. Minimum Electrical operations 6000, of following Current ratings, including making connections etc. as required.
62663 Amps
627125 Amps
628160 Amps
629200 Amps
630250 Amps
631315 Amps
632400 Amps
633630 Amps
634800 Amps
635P & F Earth leakage relay for continuous surveillance of the earth leakage current of Rating 240 VAC at 50/60 Hz, Overload : x2 continuously, x10 for 3 secs as per BS6253, Voltage Tolerance : : - 25% to +10% Operating temp.: : -10 C to +70 C, Setting of trip point : : 0.030, 0.10, 0.30, 0.50, 1.0 ,3.0 ,5.0, 10.0,20.0 & 30.0 ( User Selectable) with Alarm Relay Output, Trip Relay Output etc. as required.
636ELR with 35mm CBCT
637ELR with 70mm CBCT
638ELR with 120mm CBCT
639ELR with 210mm CBCT
640P & F of Direct on line (DOL) / Star - Delta Starter as per IEC type-2 Co-ordination chart of OEM in Existing Panel with circuit breaker having inbuilt overload protection or separate thermal Overload relay , Short circuit, phase loss protection, suitable Contactors, including wiring between switchgears, Indicating lamps for R,Y,B,ON,OFF, Push button for ON, OFF, Volt meter, Ammeter, selector switch for local/remote, auto/manual/OFF operation. Cast resin CT's, provision for potential free contacts making connection, testing etc. as required.
641Direct on line (DOL) Starter with following Motor rating
642Motor rating 0.55 KW
643Motor rating 0.75 KW
644Motor rating 1.5 KW
645Motor rating 2.2 KW
646Motor rating 4.0 KW
647Motor rating 5.5 KW
648Motor rating 7.5 KW
649Motor rating 9.0 KW
650Star - Delta Starter with following Motor rating
651Motor rating 4.0 KW
652Motor rating 5.5 KW
653Motor rating 7.5 KW
654Motor rating 9.0 KW
655Motor rating 11.0 KW
656Motor rating 15.0 KW
657Motor rating 18.5 KW
658SITC of Microprocessor based Draw out type 3/4 pole door interlock Air Circuit Breaker (ACB) as conforming to IS/IEC 60947 P - 2 :2003 in existing LT panel suitable for LT installation 440/415 V, 50 Hz and having adjustable over load, short-circuit, Instantaneous, earth fault (LSIG) with separate LED indication or Fault details on display for each type of fault shall confirm to EMI/ EMC test , LCD/LED display, last 10 trip history, Inbuilt ZSI, Current metering, Provision for Communication, Thermal memory, trip free mechanism, modular design and suitable for ambient 50 degree and utilization catagary B. In built electrical & mechanical anti pumping feature , pollution degree 3, 100% rated neutral . ACB shall have separate indication for service, test, isolation & maintenance position, Breaking capacity Icu = Ics = Icw ( 1 sec ) , U imp - 12 KV, break time not more then 30 ms. Provision for electrical & mechanical interlock between ACB sand other required accessories (Cost of accessories to be paid extra) Min.electrical operation 10000 upto 1600 A rating and 5000 for 2000 A to 4000 A. including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate.
659Manual spring charged type 4 Pole
660630/800 A Rating , 50 kA
6611000 A Rating , 50 kA
6621250 A Rating ,50 kA
6631600 A Rating ,50 kA
6642000 A Rating ,50 kA
665Supply and fixing of following accessories for Air circuit breaker (ACB) in existing ACB including making connection etc complete in all respect.
666Mechanical Interlocking Kit using key & Lock
667Closing Release
668Shunt Trip Release
669Under voltage Release
670External Neutral CT cast resin
671Microswitch for Indication
672Operation Counter
673Door Interlock
674Auxiliary Contact 4 NO + 4 NC
675SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation from 50 to 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle ( to be paid extra) , including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate.
6763 pole MCCB With Thermal Magnetic release
677up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting
678up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting,
679125 Amp , 25 kA, adjustable O/L & fixed S/C setting,
680160 Amp , 25 kA, adjustable O/L & fixed S/C setting,
681200 Amp , 25 kA, adjustable O/L & fixed S/C setting,
682250 Amp , 25 kA, adjustable O/L & adjustable S/C setting,
683250 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
684400 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
685630 Amp , 50 kA, adjustable O/L & adjustable S/C setting,
686800 Amp , 50 kA, adjustable O/L & adjustable S/C setting,
6873 pole MCCB With Microprocessor based release with adjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection.
688250 Amp , 25 kA
689400 Amp , 35 kA
690630 Amp , 50 kA
691800 Amp , 50 kA
6924 pole MCCB With Thermal Magnetic release
693up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting
694up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting,
695125 Amp , 25 kA, adjustable O/L & Fixed S/C setting,
696160 Amp , 25 kA, adjustable O/L & Fixed S/C setting,
697200 Amp , 25 kA, adjustable O/L & Fixed S/C setting,
698250 Amp , 25 kA, adjustable O/L & adjustable S/C setting,
699250 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
700400 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
701630 Amp , 50 kA, adjustable O/L & adjustable S/C setting,
702800 Amp , 50 kA, adjustable O/L & adjustable S/C setting,
7034 pole MCCB With Microprocessor based release with adjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection.
704Upto 160 Amp , 50 kA
705250 Amp , 50 kA
706400 Amp , 50 kA
707630 Amp, 50 kA
708800 Amp , 50 kA
709Supply and fixing of following accessories for Moulded case circuit breaker (MCCB) compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect.
710Shunt Trip Release
711Under Voltage Release
712Extended Rotary Handle
713Direct Rotary Handle
714Mechanical Interlocking kit
715Motor mechanism for 250A MCCB (240V, 50Hz)
716Motor mechanism for 400A MCCB (240V, 50Hz)
717Motor mechanism for 630A MCCB (240V, 50Hz)
718Auxiliary contact
719Trip Alarm contact
720Auxiliary + Trip alarm contact
721Spreaders upto 125A, 3 Pole MCCB
722Spreaders for 160A, 3 Pole MCCB
723Spreaders for 160A, 4 Pole MCCB
724Spreaders for 250A, 3 Pole MCCB
725Spreaders for 250A, 4 Pole MCCB
726Spreaders for 400A, 3Pole MCCB
727Spreaders for 400A, 4Pole MCCB
728Spreaders for 630A, 3Pole MCCB
729Spreaders for 630A, 4Pole MCCB
730Spreaders for 800A, 3Pole MCCB
731Spreaders for 800A, 4Pole MCCB
732Phase Barriers up to 630A, 3/4Pole MCCB
733External Neutral CT with Adaptor Kit
734Current Metering Module
735Providing & Fixing of IK08 and IP-30 Recessed/surface mounting heavy duty Enclosure suitable for mounting 3 / 4 pole MCCB, Inbuilt neutral linkmade out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted complete with din rail making internal DB terminations, detachable gland plate, including making connections, testing etc. as required.
736Suitable to accommodate up to 70 sqmm 3.5 core Al arm. Cable
737Suitable to accommodate above 70 sqmm 3.5 core Al arm. Cable to 185 Sqm , 3.5 core Al Arm. Cable
738SITC of IP-43 surface mounting heavy duty modular Sub main Distribution board (SMDB) fabricated by MCCB OEM in his own factory having short circuit withstand current 35 kA (upto 400 amp.Incomer ) and 50 kA for 630 amp. Incomer with suitable bottom cabling box, 4 no. corner boxes, 2 no. side cabling boxes, metering Extension box with provision of incomer suitable for 3/4 pole MCCB and 3/4 pole MCCB as outgoing, Ammeter, Voltmeter, Indicating lamp, made out from Galvanized steel / CRCA sheet of 1.2/1.6 mm thick conforming to IEC 61439 Part 1 & 2. , U imp 8 KV, form of separation 2b, powder painted complete with insulated suitable rating tinned copper bus bar, neutral bars with shrouds, earth bar , din bar, making internal DB terminations with copper lugs, detachable gland plate, including making connections, testing etc. as required. (Without MCCB, ammeter, voltmeter, selector switch , Indicating lamp)
739SMDB with 250 Amp. Incoming and 4 no. 100 Amps Outgoing
740SMDB with 250 Amp. Incoming and 8 no. 100 Amps Outgoing
741SMDB with 250 Amp. Incoming and 12 no. 100 Amps Outgoing
742SMDB with 400 Amp. Incoming and 4 no. 100 Amps Outgoing
743SMDB with 400 Amp. Incoming and 8 no. 100 Amps Outgoing
744SMDB with 400 Amp. Incoming and 12 no. 100 Amps Outgoing
745SMDB with 630 Amp. Incoming and 4 no. 100 Amps Outgoing
746SMDB with 630 Amp. Incoming and 8 no. 100 Amps Outgoing
747SMDB with 630 Amp. Incoming and 12 no. 100 Amps Outgoing
748SMDB with 630 Amp. Incoming and 6 no. 100 Amps + 2 No. 250 amp. Outgoing
749SMDB with 630 Amp. Incoming and 10 no. 100 Amps + 2 No. 250 amp. Outgoing
750Providing & Fixing of on load change over switch, front handle operated, four pole 415 V confirming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.
751Open execution type
752125 A
753160 A
754200 A
755250 A
756320 A
757400 A
758630 A
759800 A
7601000 A
761With OEM fabricated sheet steel enclosure, powder coated, door locking system allow opening of door in OFF position only with 2 nos external earthing points.
762125 A
763160 A
764200 A
765250 A
766320 A
767400 A
768630 A
769800 A
7701000 A
771Providing & Fixing of Four Pole By pass Change Over Switch confirming to IS:13947(Part 3) : IEC:60947-3-1 and IEC:60947-6-1, Open execution type in the following ratings.
772100 A
773200 A
774320 A
775400 A
776630 A
777800 A
7781000 A
779Providing & Fixing of bus bar chamber housed in sheet metal box Confirming to IEC-60439/ IS-8623 & IEC-60529/ IS-2147 made out from 1.6 mm thick powder coated CRCA sheet,degree of protection IP-31 front openable bus bar made out of aluminium or wrought aluminium alloy suitable for 200 amp. Capacity , bus bar fixed on porcelain/DMC insulators at approved spacing including making connections etc. as required.
780300 mm long , 4 strip
781450 mm long , 4 strip
782600 mm long , 4 strip
783900 mm long , 4 strip
784Providing & Laying XLPE insulated & P.V.C. sheathed Un-Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing commissioning etc. as required of following size.
7854.0 Sq. mm
7862 core
7873 core
7884 core
7896.0 Sq. mm
7902 core
7913 core
7924 core
79310.0 Sq. mm
7942 core
7953 core
7964 core
797Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size.
7986.0 Sq. mm
7992 core
8003 core
8014 core
80210.0 Sq. mm
8032 core
8043 core
8054 core
80616.0 Sq. mm
8073 core
8084 core
80925.0 Sq. mm
8103.5 core
81135.0 Sq. mm
8123.5 core
81350.0 Sq. mm
8143.5 core
81570.0 Sq. mm
8161 core
8173 core
8183.5 core
81995.0 Sq. mm
8201 core
8213.5 core
822120.0 Sq. mm
8231 core
8243.5 core
825150.0 Sq. mm
8261 core
8273.5 core
828185.0 Sq. mm
8291 core
8303.5 core
831240.0 Sq. mm
8321 core
8333.5 core
834300.0 Sq. mm
8351 core
8363.5 core
837400.0 Sq. mm
8381 core
8393.5 core
840500.0 Sq. mm
8411 core
8423.5 core
843Providing & Laying XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing commissioning etc. as required of following size.
8441.5 Sq. mm
8452 core
8463 core
8474 core
8486 core
8498 core
85010 core
85112 core
8522.5 Sq. mm
8532 core
8543 core
8554 core
8566 core
8578 core
85810 core
85912 core
8604.0 Sq. mm
8612 core
8623 core
8634 core
8646.0 Sq. mm
8652 core
8663 core
8674 core
86810.0 Sq. mm
8692 core
8703 core
8714 core
87216.0 Sq. mm
8731 core
8742 core
8753 core
8764 core
87725.0 Sq. mm
8781 core
8792 core
8803 core
8814 core
882Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Copper cable confirming to IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size.
8831.5 Sq. mm
8842 core
8853 core
8864 core
8876 core
8888 core
88910 core
89012 core
8912.5 Sq. mm
8922 core
8933 core
8944 core
8956 core
8968 core
89710 core
89812 core
8994.0 Sq. mm
9002 core
9013 core
9024 core
9036.0 Sq. mm
9042 core
9053 core
9064 core
90710.0 Sq. mm
9082 core
9093 core
9104 core
91116.0 Sq. mm
9121 core
9132 core
9143 core
9154 core
91625.0 Sq. mm
9171 core
9182 core
9193 core
9204 core
92135 Sq. mm
9221 core
9232 core
9243 core
9254 core
92650 Sq. mm
9271 core
9282 core
9293 core
9304 core
931Excavation of trench of size 75 cm (Depth) x 35 cm(Width) for laying of suitable no. of LT cables (Inter spacing between cables should not be less than 2 D) in ground with following procedure :- (a) Make a river sand bed of height 100 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 100 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable, (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth.
932Add Extra in Item no.11.5 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same
933Excavation of trench of size additional 20 cm in width, with procedure as per following points :- (a) Make a river sand bed of height 100 mm along the trench, (b) Lay another cable in middle of trench in such manner that spacing between another cable is 20 cm., (c) Provide river sand bed of height 100 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 /Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically (Longest side is vertical to cable) along the cable , (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth
934Add Extra in Item no. 11.7 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same
935Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
936Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps.
937Above 35 sq. mm and upto 95 sq. mm fixed with 40 mm x 3 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps.
938Above 95 sq. mm and upto 185 sq. mm fixed with 40 mm x 4 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps.
939Above 185 sq. mm and upto 400 sq. mm fixed with 50 mm x 5 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps.
940Add extra in item no. 11.1 to 11.4 for Laying Charges for cable through Manual Boggi by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required.
941Add Extra in item no. 11.1 to 11.4 for Laying Charges for cable through Vermeer machine by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required.
942Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.
9432 x 4.0 sq.mm
9442 x 6.0 sq.mm
9452 x 10.0 sq.mm
9462 x 16.0 sq.mm
9472 x 25.0 sq.mm
9482 x 35.0 sq.mm
9492 x 50.0 sq.mm
9502 x 70.0 sq.mm
9513 x 4.0 sq.mm
9523 x 6.0 sq.mm
9533 x 10.0 sq.mm
9543 x 16.0 sq.mm
9553 x 25.0 sq.mm
9563 x 35.0 sq.mm
9573 x 50.0 sq.mm
9583 x 70.0 sq.mm
9593.5 x 25.0 sq.mm
9603.5 x 35.0 sq.mm
9613.5 x 50.0 sq.mm
9623.5 x 70.0 sq.mm
9633.5 x 95.0 sq.mm
9643.5 x 120.0 sq.mm
9653.5 x 150.0 sq.mm
9663.5 x 185.0 sq.mm
9673.5 x 240.0 sq.mm
9683.5 x 300.0 sq.mm
9693.5 x 400.0 sq.mm
9703.5 x 500.0 sq.mm
9713.5 x 630.0 sq.mm
9724 x 4.0 sq.mm
9734 x 6.0 sq.mm
9744 x 10.0 sq.mm
9754 x 16.0 sq.mm
9761 x 70.0 sq.mm
9771 x 95.0 sq.mm
9781 x 120.0 sq.mm
9791 x 150.0 sq.mm
9801 x 185.0 sq.mm
9811 x 240.0 sq.mm
9821 x 300.0 sq.mm
9831 x 400.0 sq.mm
9841 x 500.0 sq.mm
9851 x 630.0 sq.mm
9861 x 800.0 sq.mm
9871 x 1000.0 sq.mm
988Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty Copper lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tape for following size of PVC insulated & PVC sheathed/ XLPE copper conductor cable of 1100 volt grade as required.
9891 x 16.0 sq.mm
9901 x 25.0 sq.mm
9911 x 35.0 sq.mm
9921 x 50.0 sq.mm
9931 x 70.0 sq.mm
9941 x 95.0 sq.mm
9951 x 120.0 sq.mm
9962 x 4.0 sq.mm
9972 x 6.0 sq.mm
9982 x 10.0 sq.mm
9992 x 16.0 sq.mm
10002 x 25.0 sq.mm
10012 x 35.0 sq.mm
10022 x 50.0 sq.mm
10032 x 70.0 sq.mm
10042 x 95.0 sq.mm
10052 x 120.0 sq.mm
10063 x 1.5 sq.mm
10073 x 2.5 sq.mm
10083 x 4.0 sq.mm
10093 x 6.0 sq.mm
10103 x 10.0 sq.mm
10113 x 16.0 sq.mm
10123 x 25.0 sq.mm
10133 x 35.0 sq.mm
10143 x 50.0 sq.mm
10153 x 70.0 sq.mm
10163 x 95.0 sq.mm
10173 x 120.0 sq.mm
10184 x 1.5 sq.mm
10194 x 2.5 sq.mm
10204 x 4.0 sq.mm
10214 x 6.0 sq.mm
10224 x 10.0 sq.mm
10234 x 16.0 sq.mm
10244 x 25.0 sq.mm
10254 x 35.0 sq.mm
10264 x 50.0 sq.mm
10274 x 70.0 sq.mm
10284 x 95.0 sq.mm
10294 x 120.0 sq.mm
10306 x 1.5 sq.mm
10316 x 2.5 sq.mm
10328 x 1.5 sq.mm
10338 x 2.5 sq.mm
103410 x 1.5 sq.mm
103510 x 2.5 sq.mm
103612 x 1.5 sq.mm
103712 x 2.5 sq.mm
1038Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) confirming to IS 8309 -1993 duly crimped with crimping tool, PVC tape etc of following size.
10391.5 Sq.mm
10402.5 Sq.mm
10414.0 Sq.mm
10426.0 Sq.mm
104310.0 Sq.mm
104416.0 Sq.mm
104525.0 Sq.mm
104635.0 Sq.mm
104750.0 Sq.mm
104870.0 Sq.mm
104995.0 Sq.mm
1050120.0 Sq.mm
1051150.0 Sq.mm
1052185.0 Sq.mm
1053240.0 Sq.mm
1054300.0 Sq.mm
1055400.0 Sq.mm
1056500.0 Sq.mm
1057630.0 Sq.mm
1058800.0 Sq.mm
10591000.0 Sq.mm
1060Supplying and making end termination with heavy duty Copper lugs ( ANY type ) confirming to IS 8309 -1993 duly crimped with crimping tool, PVC tape etc of following size.
10611.5 Sq.mm
10622.5 Sq.mm
10634.0 Sq.mm
10646.0 Sq.mm
106510.0 Sq.mm
106616.0 Sq.mm
106725.0 Sq.mm
106835.0 Sq.mm
106950.0 Sq.mm
107070.0 Sq.mm
107195.0 Sq.mm
1072120.0 Sq.mm
1073Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.
1074100mm x 50mm x 1.6mm
1075150mm x 50mm x 1.6mm
1076225mm x 50mm x 1.6mm
1077300mm x 50mm x 1.6mm
1078375mm x 50mm x 2.0mm
1079450mm x 50mm x 2.0mm
1080600mm x 50mm x 2.0mm
1081300mm x 62.5mm x 2.0mm
1082375mm x 62.5mm x 2.0mm
1083450mm x 62.5mm x 2.0mm
1084600mm x 62.5mm x 2.0mm
1085750mm x 62.5mm x 2.0mm
1086600mm x 75mm x 2.0mm
1087750mm x 75mm x 2.0mm
1088Supply, Fabricating & installing following sizes of perforated Powder coated MS cable tray with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.
1089100mm x 50mm x 1.6mm
1090150mm x 50mm x 1.6mm
1091225mm x 50mm x 1.6mm
1092300mm x 50mm x 1.6mm
1093375mm x 50mm x 2.0mm
1094450mm x 50mm x 2.0mm
1095600mm x 50mm x 2.0mm
1096300mm x 62.5mm x 2.0mm
1097375mm x 62.5mm x 2.0mm
1098450mm x 62.5mm x 2.0mm
1099600mm x 62.5mm x 2.0mm
1100750mm x 62.5mm x 2.0mm
1101600mm x 75mm x 2.0mm
1102750mm x 75mm x 2.0mm
1103Supply, Fabricating & installing following sizes of Hot dipped Galvanized iron Ladder type cable tray ( Galvanized thickness not less then 50 microns) with rungs at span of 250mm including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling/wall with M.S. suspenders etc. as required.
1104100mm x 50mm x 1.6mm
1105150mm x 50mm x 1.6mm
1106225mm x 50mm x 1.6mm
1107300mm x 50mm x 1.6mm
1108375mm x 50mm x 2.0mm
1109450mm x 50mm x 2.0mm
1110600mm x 50mm x 2.0mm
1111300mm x 62.5mm x 2.0mm
1112375mm x 62.5mm x 2.0mm
1113450mm x 62.5mm x 2.0mm
1114600mm x 62.5mm x 2.0mm
1115750mm x 62.5mm x 2.0mm
1116600mm x 75mm x 2.0mm
1117750mm x 75mm x 2.0mm
1118Supplying and fixing of CE certified and UL listed GI wire mesh cable tray made from spot welded steel wire hot dipped galvanised between 60 and 80 microns of zinc as per BS 729 including horizontal and vertical bends, reducers, tees, cross members and other OEM made accessories like wall clamp, hold down clamps, Earthing terminal, brackets as required, and duly suspended from the ceiling with electro-zinc coated TF rods, etc. as required of following sizes.
1119100 mm x 50 mm x 3.5 - 5.9 mm
1120150 mm x 50 mm x 3.5 - 5.9 mm
1121200 mm x 50 mm x 3.5 - 5.9 mm
1122300 mm x 50 mm x 3.5 - 5.9 mm
1123400 mm x 50 mm x 3.5 - 5.9 mm
1124500 mm x 50 mm x 3.5 - 5.9 mm
1125100 mm x 100 mm x 3.5 - 5.9 mm
1126150 mm x 100 mm x 3.5 - 5.9 mm
1127200 mm x 100 mm x 3.5 - 5.9 mm
1128300 mm x 100 mm x 3.5 - 5.9 mm
1129400 mm x 100 mm x 3.5 - 5.9 mm
1130500 mm x 100 mm x 3.5 - 5.9 mm
1131Supply and fixing following size of Pre Galvanized (275 GSM) floor raceways / Under floor trunking with/ without partion, including common cover, joint sleeve, cross over junction Box etc. as required.
113275 mm x 25 mm x 1.5 mm
1133100 mm x 25 mm x 1.5 mm
1134150 mm x 25 mm x 1.5 mm
1135250 mm x 25 mm x 1.5 mm
1136300 mm x 25 mm x 1.5 mm
113775 mm x 38 mm x 1.5 mm
1138100 mm x 38 mm x 1.5 mm
1139150 mm x 38 mm x 1.5 mm
1140250 mm x 38 mm x 1.5 mm
1141300 mm x 38 mm x 1.5 mm
1142150 mm x 38 mm x 2.0 mm with 2 Compartment
1143250 mm x 38 mm x 2.0 mm with 3 Compartment
1144300 mm x 38 mm x 2.0 mm with 3 Compartment
1145Supply and fixing following Pre Galvanized (275 GSM) Adjustable Junction Box for floor raceways / Under floor trunking etc. as required.
1146Junction Box 200 mm x 200 mm x 40-75 mm with Galvanized Lid
1147Junction Box 250 mm x 250 mm x 40-75 mm with Galvanized Lid
1148Junction Box 300 mm x 300 mm x 40-75 mm with Galvanized Lid
1149Junction Box 350 mm x 350 mm x 40-75 mm with Galvanized Lid
1150Junction Box 250 mm x 250 mm x 40-75 mm with stainless steel Lid
1151Junction Box 300 mm x 300 mm x 40-75 mm with stainless steel Lid
1152Junction Box 350 mm x 350 mm x 60-120 mm with stainless steel Lid
1153S & Making Heat shrinkable type Tubular sleeve version outdoor straight through joint for following size of PVC/ XLPE insulated aluminium conductor cable of 1.1 KV grade as required.
11541 x 25 sq.mm-50 sq.mm
11551 x 70 sq.mm-150 sq.mm
11561 x 185 sq.mm-300 sq.mm
11571 x 400 sq.mm
11581 x 500 sq.mm
11593/3.5/4 x 1.5 sq.mm-6 sq.mm
11603/3.5/4 x 10.0-16.0 sq.mm
11613/3.5/4 x 25.0 sq.mm-50 sq.mm
11623/3.5/4 x 70.0 sq.mm-150 sq.mm
11633/3.5/4 x 185.0 sq.mm-300 sq.mm
11643/3.5/4 x 400 sq.mm
11653/3.5/4 x500 sq.mm
1166S/F cable route marker with 10cm x 10cm x 5mm thick or 10 cm dia. G.I.plate with inscription thereon, bolted/welded to 35mm x 35mm x 5mm angle iron, 60cm long and fixing the same in ground in C C ( 1:3:6 ) as required
1167P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra).
116850 mm
116963 mm
117075 mm
117190 mm
1172110 mm
1173120 mm
1174160 mm
1175200 mm
1176Providing and laying Non Pressure NP-3 class R.C.C. pipes confirming to IS:458 including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) etc. as required. (Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra).
1177200 mm Dia.
1178250 mm dia.
1179300 mm dia
1180450 mm dia.
1181Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.
1182Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.
1183Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.
1184SITC of Copper Bonded rod Earthing with high tensile strength (more than 600 N / sq.mm low carbon steel rod molecularly bonded with Copper thickness (250 microns) and confirming to UL 467 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :-
1185(a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole
1186(b)Earth enhancing compound to ensure the moisture content and electrical conductivity, 25 kg for 3000 mm. The compound shall be tested form NABL accredited lab for low resistivity (less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content in accordance with IEC 62561-7
1187© Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt
1188(d) Place Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm.
1189(e) Testing of earth resistance for value of 5 ohms or less as required.
1190(f) Test certificates for confirming above standards from OEM is mandatory.
119117.2 mm thick and 3 Mtr. Long
119225 mm thick and 3 Mtr. Long
1193SITC of Strip in Pipe Earthing using hot-dip galvanized 'B' class G.I. pipe, as secondary conductor. The system shall incorporate a crystalline conductive compound between the primary and secondary conductors to enhance conductivity and long-term stability. of following size and length and as per point mentioned (a), (b), [c), (d), (e) (f) as below
1194(a) Bore a hole of dia. 150 mm of required length, Place the rod in the centre of Hole
1195(b)Earth enhancing compound to ensure the moisture content and electrical conductivity, 30 kg for 3000 mm. 20 Kg. for 2000 mm The compound shall be tested form NABL accredited lab for low resistivity (less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content in accordance with IEC 62561-7
1196© Connect the Strip Terminal (110 mm long) with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt
1197(d) Place Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm.
1198(e) Testing of earth resistance for value of 5 ohms or less as required.
1199(f) Test certificates for confirming above standards from OEM is mandatory.
1200Outer Pipe - 76 mm dia GI pipe , Inner Conductor- GI strip 50x6 mm Length 3meter. Terminal 50x6mm GI.
1201Outer Pipe - 76 mm dia GI pipe , Inner Conductor- GI strip 50x6 mm Length 2 meter.Terminal 50x6mm GI.
1202Outer Pipe - 76 mm dia GI pipe , Inner Conductor- Copper strip 25x3 mm Length 3meter. Terminal 50x6mm Copper.
1203Outer Pipe - 76 mm dia GI pipe , Inner Conductor- Copper strip 25x3 mm Length 2 meter.Terminal 50x6mm Copper.
1204Outer Pipe - 56 mm dia GI pipe , Inner Conductor- GI strip 25x3 mm Length 3meter. Terminal 40x5 mm GI.
1205Outer Pipe - 56 mm dia GI pipe , Inner Conductor- GI strip 25x3 mm Length 2 meter. Terminal 40x5 mm GI.
1206Outer Pipe - 56 mm dia GI pipe , Inner Conductor- Copper strip 25x3 mm Length 3meter. Terminal 40x5 mm Copper.
1207Outer Pipe - 56 mm dia GI pipe , Inner Conductor- Copper strip 25x3 mm Length 2 meter. Terminal 40x5 mm Copper.
1208Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping double the width of strip and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.
120920mm x 3mm copper strip
121025mm x 3mm copper strip
121125mm x 5mm copper strip
121230mm x 5 mm copper strip
121340mm x 6mm copper strip
121450mm x 6mm copper strip
121520mm x 3mm tinned copper strip
121625mm x 3mm tinned copper strip
121725mm x 5mm tinned copper strip
121830mm x 5 mm tinned copper strip
121940mm x 6mm tinned copper strip
122050mm x 6mm tinned copper strip
122120mm x 3mm G.I. ( Hot Dipped ) Strip
122225mm x 3mm G.I. ( Hot Dipped ) Strip
122325mm x 6mm G.I. ( Hot Dipped ) Strip
122432mm x6mm G.I. ( Hot Dipped ) Strip
122550mm x 6mm G.I. ( Hot Dipped ) Strip
1226Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required.
12276 SWG tinned copper Wire
12288 SWG tinned copper Wire
122910 SWG tinned copper. Wire
12306 SWG copper Wire
12318 SWG copper Wire
123210 SWG copper. Wire
12336 SWG G.I. ( Hot Dipped ) Wire
12348 SWG G.I. ( Hot Dipped ) Wire
123510 SWG G.I. ( Hot Dipped ) Wire
123616 Sq.mm Copper coated steel stranded conductor (Wt. 130 Kg/Km)
123725 Sq.mm Copper coated steel stranded conductor ( Wt. 200Kg/Km)
1238Supply & Laying following size' B ' class , G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. (Earth Excavation will be Paid Extra)
123915 mm dia.
124020 mm dia.
124125 mm dia.
124232mm dia
124340 mm dia.
124450 mm dia.
124565 mm dia.
124680 mm dia.
1247100 mm dia.
1248150 mm dia.
1249Mesh earthing as per IS:3043 with Hot dipped galvanized earth strip of size 25 mm x 6 mm to form a mesh of size 1000 mm x 1000 mm in horizontal formation to create equal sections of 200 mm x 200 mm by means of welding and embodying 1 mtr. Below the ground level, refilling the pit by alternative layers of charcoal & salt up to 500 mm with 20 mm dia. GI 'B' class watering pipe, wire mesh funnel and 300 mm x 300 mm size masonary chamber with lockable 6 mm thick MS sheet cover hinged with suitable angle iron frame testing of earth resistance for value of 5 ohms or less as required.
1250P & F of Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm.
1251S & F of Earth Bar with Disconnecting link Made out from 50 mm x 6 mm copper purity purity >95% /GI strip pre fitted on epoxy powder coated metal base mounted on hexagonal SMC Insulators of following Size.
1252400 mm , 6 Way Copper
1253600 mm , 10 Way Copper
1254400 mm , 6 Way GI
1255600 mm , 10 Way GI
1256Providing & Making of Exothermic joint in Tee / Square / Straight through joint in Strip for permanently bonding of copper to copper or copper to GI including required exothermic jointing kit comprising of graphite mould, weld powder, tools etc. as required.
1257Supply, installation, testing & commissioning of following size & Material Lightning protection system accessories meeting requirement of IS/IEC 62305 and tested as per IEC 62561-2 / IS 18925 (Part 1-7) : 2025 as required.
1258100 microns Copper bonded steel Solid round conductor 10 mm dia.
1259Aluminium alloy Solid round conductor 8 mm dia.
1260SS 304 Solid round conductor 10 mm dia.
1261Alluminium alloy Vertical Air termination 16/10 mm with base mounted on 2000 mm 40 mm GI pipe as mast
1262Alluminium alloy Vertical Air termination 16/10 mm with base mounted on 3000 mm 40 mm GI pipe as mast
1263Alluminium alloy Vertical Air termination 16/10 mm with base mounted on 5000 mm 56/40 mm GI pipe as mast
1264Alluminium alloy Vertical Air termination 16/10 mm with base mounted on 5000 mm 76/56/40 mm GI pipe as mast
1265Alluminium alloy Vertical Air termination 16/10 mm with SS 304 Clamp of Size 1000 mm for Wall
1266Alluminium alloy Vertical Air termination 16/10 mm with SS 304 Clamp of Size 2000 mm for Wall
1267Alluminium alloy Vertical Air termination 16/10 mm with SS 304 Holder of Size 1000 mm for Parapet
1268SS 304 Clamp to join Vertical Air terminal and 8/10 mm round conductor
1269SS 304 Clamp to join Vertical Air terminal and 25 mm x 3 mm flat conductor
1270SS 304 holder for 8/10 mm round conductor on Parapet
1271SS 304 holder with Concrete base for 8/10 mm round conductor on Flat roof
1272SS 304 clamp connector for 8/10 mm round conductor on metal structure
1273SS 304 cross connector for 8/10 mm round conductor
1274Alluminium alloy expansion piece with connector for 8/10 mm round conductor
1275Alluminium alloy straight,cross & T connector for 8/10 mm round conductor
1276SS 304 straight connector for 8/10 mm round conductor
1277SS 304 conductor holder for 25 mm x 3 mm Flat conductor
1278SS 304 holder with Concrete base for 25 mm x 3 mm Flat conductor on Flat roof
1279Alluminium alloy expansion piece for 25 mm x 4 mm flat conductor
1280SS 304 cross connector for 25 mm x 3 mm flat conductor
1281SS 304 test joint with Polycarbonate enclosure with copper flat with 4 holes of 8/10 mm dia to connect round conductor
1282SS 304 test joint with Polycarbonate enclosure with copper flat with 4 holes of 8/10 mm dia to connect round conductor
1283SS 304 Earth stud for air terminal and 8/10 mm round conductor
1284SS 304 Equipotential Bonding rail 500 x 50 x 10 mm
1285Lightning Surge Counter designed to record and display lightning strike events. The counter shall feature a 3 digit LCD screen (0-999 events) for clear event tracking and operate on a battery powered system.
1286Supply, installation, and testing of an Early Streamer Emission (ESE) Air Terminal, designed and tested in accordance with NFC 17-102 standards, with Delta T ( Initiation Advance ) time tested and certified by an ILAC-accredited high-voltage test laboratory. The air terminal shall be constructed from corrosion-resistant materials to ensure durability and long-term performance. It shall be installed at the highest point of the structure and mounted on a mast of minimum 5.5 meters or as determined by the initiation advance time (ΔT) calculations, ensuring the required protection radius. The protection radius shall be determined as per NFC 17-102, based on the level of risk protection required (Levels I to IV), with proper Earthings integration for effective lightning dissipation.
1287ES-60 Triggering Advance Time (ΔT) -60µs, Protection Radius (meters) as per Highest Risk 79 Mtr.
1288ES-45 Triggering Advance Time (ΔT) -45µs, Protection Radius (meters) as per Highest Risk 61 Mtr.
1289ES-30 Triggering Advance Time (ΔT) -30µs, Protection Radius (meters) as per Highest Risk 42 Mtr.
1290Supply, fabrication, and installation of a galvanized iron (GI) pipe support structure ( Lightning Mast ) with a 350 mm × 350 mm base plate and 10 mm thickness for secure mounting. The mast shall support the ESE air terminal and include provisions for a guy wire clamping system to ensure stability. It shall provide a secure arrangement for fixing the air terminal and have appropriate termination point / arrangement for connection to the downconductor.
1291Total Mast height : 3-4.5 meter
1292Total Mast height : 5-7.5 meter
1293Total Mast height : 8-10 meter
1294Supply and installation of an 8 mm aluminum down conductor, designed for efficient dissipation of lightning currents. The conductor shall be securely fixed using corrosion-resistant clamps at appropriate intervals, ensuring a continuous, low-resistance path from the air terminal to the earthing system. The conductor length shall be determined based on actual site conditions, with all necessary accessories, including clamps, connectors, and fasteners.
1295Making of hole in wall (brick/stone) of required and placing NP-2 RCC pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size.
1296Up to 457 mm size
1297more than 457 mm & up to 610 mm
1298Supply & Fixing of phenolic laminated board of 6.0 mm thick for fresh air fan/exhaust fan up to size of 300 mm on existing window frame including cost of board, cutting of hole , Nut bolts etc. as required.
1299Installation , testing and Commissioning of ceiling fan (any size) including wiring the down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor, Cotter pin, rubber grommet making connection testing etc. as required.
1300With regulator
1301Without regulator
1302Providing & Fixing BLDC technology step regulator compatible ceiling fan, with aluminium body & aluminium blade, power factor not less then 0.9 , following service value (CMM/W) , with following air delivery , speed 350 RPM ( tolerance as per IS:374 2019 ) THD less then 10%, copper winding with class of Insulation 'F' complete with with secondary support safety cable ( steel rope), down rod up to 30 cm, cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.
13031200 mm sweep with Air delivery >/= 230 CMM and Service Value 8.20
13041400 mm sweep with Air delivery >/= 270 CMM and Service Value 7.70
13051200 mm sweep with Air delivery >/= 215 CMM and Service Value 7.00
13061400 mm sweep with Air delivery >/= 260 CMM and Service Value 6.4
1307Providing & Fixing of of BLDC Technology ventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutter including making connection, testing etc. as required.
1308150 mm sweep with Min. Air delivery 350 Cubic meter/Hr, 2000 RPM
1309200 mm sweep with Min. Air delivery 800 Cubic meter/Hr, 1600 RPM
1310250 mm sweep with Min. Air delivery 1150 Cubic meter/Hr, 1300 RPM
1311Providing & Fixing of 400 mm Sweep BLDC technology Oscillating type Wall mounting / Pedestal type fans with Three speed, ON and OFF position, Double Wall bearing with front and back 120 or more ribs guard; Three no. blades, noise level should be <= 75 dB, including fixing with anchor bolts, making connection testing etc. as required. ( With Remote )
1312Wall mounting type with Service value 2.0 CMM /W, Min. Air Delivery 71 CMM
1313Pedestal Type having Adjustable Height with Service value 2.6 CMM /W, Min. Air Delivery 85 CMM
1314Providing & Fixing of BEE Star rated copper wounded with class of Insulation 'F', double ball bearing capacitor start, aluminium body & aluminium blade ceiling fan conforming to all the performance requirements laid down in IS 374:2019 with down rod up to 30 cm with secondary support safety cable ( steel rope) , cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor and making connection testing etc. as required.
13151200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 )
13161200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 )
13171200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 )
13181400 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 )
13191400 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 )
13201200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) with minimum Air delivery 230 CMM
13211400 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) with minimum Air delivery 230 CMM
1322Providing & Fixing of shackle (iron hook) made from 2mm nominal thick CRCA sheet and bolts (2nos) of 6mm with spring washer nut, checknut & split pin as required.
1323Providing & Fixing of of M.S. J- hook of standard design made out of 16 mm dia. M.S. round bar and fixed with cement concrete mortar with required support as required.
1324P & F 1.2 mm thick M.S. Recessed fan box and top lid screwed on Box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 150 mm length extended on each side as required.
1325P & F 3.0 mm thick Poly propelene plastic polished concealed fan box, squre of size (106x106) mm dia, depth 50 mm , 10 mm dia rod of MS with chrome plated with 55 mm length extended on each side as required.
1326Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core 1.5 Sq.mm copper conductor ,making connections, testing etc. as required.
1327230 mm sweep, Minimum air delivery 750 Cum / hour
1328300 mm sweep Minimum air delivery 1600 Cum / hour
1329Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 marked in existing opening including making connections testing etc. as required.
1330300 mm sweep(900 RPM)
1331380 mm sweep(900 RPM)
1332450 mm sweep(1400 RPM)
1333600 mm sweep(900 RPM)
1334Providing & Fixing of ventilating fans Capacitor start, copper wounded, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required.
1335150 mm sweep Minimum Air Delivery 150 Cum / hour
1336200 mm sweep Minimum Air Delivery 450 Cum / hour
1337250 mm sweep Minimum Air Delivery 750 Cum / hour
1338Providing & Fixing of Wall mounting / Pedestal type Heavy duty Air Circulator , Double ball bearing and with metal sturdy mesh guard; Aluminium alloy one piece blade and conforming to IS:2997, including fixing with anchor bolts, making connection testing etc. as required.
1339450 mm sweep Wall mounting and three speed regulator with Minimum Air Delivery 150 Cum. / Minute
1340450 mm sweep Pedestal type and three speed regulator with Minimum Air Delivery 150 Cum. / Minute
1341600 mm sweep Wall mounting with Minimum Air Delivery 270 Cum. / Minute
1342600 mm sweep Pedestal type with Minimum Air Delivery 270 Cum. / Minute
1343750 mm sweep Wall mounting with Minimum Air Delivery 400 Cum. / Minute
1344750 mm sweep Pedestal type with Minimum Air Delivery 400 Cum. / Minute
1345Providing & Fixing of 450 mm Sweep Oscillating type Wall mounting / Pedestal type fans with Three speed, ON and OFF position, Sintered Iron bush oil impregnated, with metal front and back 120 or more ribs guard; Three no. Aluminium blades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be <= 75 dB, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required.
1346Wall mounting type with Adjustable Vertical Angle
1347Pedestal Type with Adjustable Height
1348Providing & Fixing of extra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe including cutting, threading, drilling, fixing quarter pin etc as required.
1349Numbering of ceiling fans/ fixtures with approved enamel paint etc as required.
1350P & F of Gravity Louver shutter of superior quality made out of frame of 18 swg M.S. sheet & Louvers made from 24 swg MS Sheet with enamel paint including cost of nuts, bolts, etc as required.
1351Up to 380 mm size
1352above 380 mm size
1353P & F of Wall cowl with Bird Screen Suitable for Outside Wall of Exhaust Fan Opening of following size and made out from 24 SWG GI sheet as per instructions of Engineer in charge including fixing with suitable fasteners etc. as required.
1354Suitable for 300 mm sweep Exhaust Fan
1355Suitable for 380 mm sweep Exhaust Fan
1356Suitable for 450 mm sweep Exhaust Fan
1357S & F Extruded Aluminium Fresh Air / External Weather Louver, Small Format type with 38 mm flange width & 50 mm depth. finish - powder coated off white with aluminium mesh of required size.
1358SITC of single phase 230 V, 50 Hz, Permanent Magnet synchronous motorised (PMSM) High volume low speed (HVLS) fan comprising of aviation grade extruded Alluminium alloy 6063-T grade aerofil 5/6 blade, Suitable Hanging bracket with extension tube for suitable clearance from blade to ceiling, Fastners, Nut bolts, PVC coated GI guy Wire rope, VFD control panel, sound level 45-50 dB, suitable cable from control panel to Fan motor of following sizes.
13598' dia, floor to fan blade height 12-15 ft,. Area coverage 4000 sq.ft, air delivery 136000 cfm, 110 RPM
136010' dia, floor to fan blade height 14-17 ft,. Area coverage 5500 sq.ft, air delivery 150000 cfm, 100 RPM
136112' dia, floor to fan blade height 16-18 ft,. Area coverage 7000 sq.ft, air delivery 164000 cfm, 95 RPM
136216' dia, floor to fan blade height 18-22 ft,. Area coverage 10000 sq.ft, air delivery 220000 cfm, 80 RPM
136320' dia, floor to fan blade height 22-27 ft,. Area coverage 13500 sq.ft, air delivery 280000 cfm, 65 RPM
136424' dia, floor to fan blade height 27-30 ft,. Area coverage 18500 sq.ft, air delivery 380000 cfm, 55 RPM
1365Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap action adjustable thermostat , Dual indicating lamps Injected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top , including making inlet, outlet Flexible alloy connection, testing etc. as required.
13666 Ltr.
136710 Ltr.
136815 Ltr.
136925 Ltr.
137035 Ltr.
137150 Ltr.
1372Providing & Fixing of stem type ISI marked (IS 3017 / 85) snap action adjustable thermostat for storage water heater including making connection testing etc. complete in all respect.
1373Providing & Fixing of stem type ISI marked (IS 3017 / 85) , snap action bipolar adjustable thermostat with built in auto thermal cut out for storage water heater including making connection testing etc. complete in all respect.
1374Providing & Fixing 2 / 3 KW nickle plated, mineral filled heating element including making connection testing etc complete in all respect.
1375Providing & Fixing of 2 / 3 KW Glass Line Coated , mineral filled heating element including making connection testing etc complete in all respect.
1376Providing & Fixing of Multi safety valve of 8.5 bar capacity with built in drain, NRV, Vacuum release, Pressure release etc. as required complete in all respect.
1377Providing & Fixing of Twin neon indicating lamp of superior quality for storage water heater complete in all respect.
1378Providing & Fixing of 13 mm Brass with C.P. finished ISI marked angle valve for storage water heater as required complete in all respect.
1379Providing & Fixing of heavy duty flexible alloy pipe for storage water heater for inlet and outlet of suitable length including the cost of nuts, washers etc complete in all respect.
1380450 mm
1381600 mm
1382Charges for descaling of storage water heater including replacement of Multi Function Valve as required.
1383Charges for Fixing of storage water heater including 10/12 mm Anchor fasteners of suitable size, testing, carrying from store to site,etc. as required.
1384Providing & Fixing of 2.0 KW twin ceremic cartridge, Withstands temperatures up to 1000 C long lasting even in hard water including making connection testing etc complete in all respect.
1385SITC of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output only at CW (5700K to 6500K) , internal surge protection of 4.0 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
13861170mm(+/-10%) LED batten with min. lumen output 2200 lm
1387570mm (+/-10%) batten with min. lumen output 1000 lm
13881170mm(+/-10%) LED batten with min. lumen output 4400 lm
1389SITC of IP20 SMD Mid Power LED batten with integrated box (min.1200mmx40mmx60mm including reflector) with replacable driver fixture made from Powder coated Extruded aluminium housing ,Min. lumen output 4800 lm, System lumen efficacy ≥ 120 lm/Watt output nly at CW (5700K to 6500K), internal surge protection of 4.0 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
1390SITC of IP-20 LED Recessed / Surface Mounted, Round / Square backlit & SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS compliance 4.0 KV surge protected Isolated driver, with Short & Open circuit protection input 320VAC-48 hr protection, input 350VAC-2 hr protection), having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt,at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
1391Recessed Mounting
1392Minimum lumen output 600 lm (lumen efficacy ≥ 100 lm / watt)
1393Minimum lumen output 1300 lm
1394Minimum lumen output 1600 lm
1395Minimum lumen output 1950 lm
1396Minimum lumen output 2400 lm
1397Surface Mounting (with extruded alumn. Housing )
1398Minimum lumen output 600 lm (lumen efficacy ≥ 100 lm / watt)
1399Minimum lumen output 1300 lm
1400Minimum lumen output 1600 lm
1401Minimum lumen output 1950 lm
1402Minimum lumen output 2400 lm
1403SITC of IP20, 2'x2' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmissivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V . High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection ( input 320VAC-48 hoursprotection,input 350VAC-2 hours protection) (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
1404Recessed Mounting
1405Minimum lumen output 4320 lm
1406Minimum lumen output 4800 lm
1407Surface Mounting (Driver should be Inside the Luminaire)
1408Minimum lumen output 4320 lm
1409Minimum lumen output 4800 lm
1410SITC of IP20, 1'X1' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution.operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
1411Recessed Mounting
1412Minimum lumen output 2880 lm
1413Minimum lumen output 3600 lm
1414Surface Mounting (Driver should be Inside the Luminaire)
1415Minimum lumen output 2880 lm
1416Minimum lumen output 3600 lm
1417SITC of IP20, 1'x4' LED Surface/ Recessed mounting Mid power SMD type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V. High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
1418Recessed Mounting
1419Minimum lumen output 4320 lm
1420Minimum lumen output 4800 lm
1421Surface Mounting (Driver should be Inside the Luminaire)
1422Minimum lumen output 4320 lm
1423Minimum lumen output 4800 lm
1424SITC of IP20, 1100-1200 mm x 50-60 mm x 70-85 mm size Suspended mounting backlit & SMD mid power type LED linear Light fixture made from Extruded Aluminium housing, PMMA Acrylic/Extruded Polycarbonate push fit type diffuser for uniform light distribution. High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). Lumen Efficacy will be >=100lm/W only at CW (5700K to 6500K) ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating . Luminiare can connect each other through jointer kit (cost of jointer kit is included) as required.
1425Minimum lumen output 2000 lm
1426Minimum lumen output 3000 lm
1427SITC of IP65 IK08 rated Integrated High power LED ( each LED between 3 to 5 watt power with secondary lencs on each LED) Highbay light fixture made from Pressure Die Cast Aluminium housing, UV stabilized PC Cover/ Toughened glass diffuser, potted driver, Eye bolt for mounting, system lumen efficacy ≥150 lm/Watt output , THD < 10% ,p.f.≥0.95,CRI >70 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and . surge protection 4 KV inbuilt & 10 KV external inside fixture as required.
1428Minimum lumen output 12000 lm
1429Minimum lumen output 15000 lm
1430Minimum lumen output 18000 lm
1431Minimum lumen output 22500 lm
1432SITC of Suspended mounting IP66 IK08 rated Integrated High power LED Wellglass light fixture made from Pressure Die Cast Aluminium housing, potted driver, Eye bolt for mounting, PC clear / Opal Diffuser, system lumen efficacy ≥130 lm/Watt output only at CW (5700K to 6500K) , THD < 10% ,p.f.≥0.95,CRI >70 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating surge protection 4 KV inbuilt & 10 KV external inside fixture as required.
1433Minimum lumen output 4550 lm
1434Minimum lumen output 9100 lm
1435SITC of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
14362/3 Watt
14376/7 Watt
14389 Watt
143915 Watt
144018/20 Watt
1441SITC of IP 20 box made out from 1.0 mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tube including side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube).
1442Suitable for 2' LED Tube shape fixture for single rod
1443Suitable for 4' LED Tube shape fixture for single rod
1444Suitable for 4' LED Tube shape fixture for double rod
1445SITC of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt outputonly at CW (5700K to 6500K) , internal surge protection of 2.5 KV,THD < 15% ,p.f.≥0.95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
1446600mm , Min. Lumens output 1800 lm LED Tube rod with Polycarbonate Housing
14471200mm , Min. Lumens output 2000 lm LED Tube rod with Polycarbonate Housing
14481200mm, Min. Lumens output 2000 lm LED Tube rod with Glass Housing
1449SITC of IP65 IK08 rated Integrated SMD Mid power LED bulk head type light fixture made from Pressure Die Cast AL housing suitable with integral driver, system lumen efficacy ≥120 lm/Watt output only at CW (5700K to 6500K) , THD < 15% ,p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
1450Minimum lumen output 1200 lm
1451SITC of IP-20 LED Recessed / Surface Mounted, Round / Sqaure backlit & SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 4.0 KV surge protected Isolated driver, with Short & Open circuit protection input 320VAC-48 hr protection, input 350VAC-2 hr protection), having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt,at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, UGR (unified glare rating)<19, fliker free (current ripple should be below 5%), SDCm (standard deviation colour matching)<5.life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
1452Recessed Mounting
1453Minimum lumen output 1300 lm
1454Minimum lumen output 1600 lm
1455Minimum lumen output 1950 lm
1456Minimum lumen output 2400 lm
1457Surface Mounting (with extruded alumn. Housing )
1458Minimum lumen output 1300 lm
1459Minimum lumen output 1600 lm
1460Minimum lumen output 1950 lm
1461Minimum lumen output 2400 lm
1462SITC of IP20, 2'x2' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V . High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection ( input 320VAC-48 hoursprotection,input 350VAC-2 hours protection) (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , UGR (unified glare rating)<19, fliker free (current ripple should be below 5%), SDCm (standard deviation colour matching)<5 life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
1463Recessed Mounting
1464Minimum lumen output 4320 lm
1465Minimum lumen output 4800 lm
1466Surface Mounting (Driver should be Inside the Luminaire)
1467Minimum lumen output 4320 lm
1468Minimum lumen output 4800 lm
1469SITC of IP20, 1'x4' LED Surface/ Recessed mounting Mid power SMD type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V. High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , UGR (unified glare rating)<19, fliker free (current ripple should be below 5%), SDCM (standard deviation colour matching)<5life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
1470Recessed Mounting
1471Minimum lumen output 4320 lm
1472Minimum lumen output 4800 lm
1473Surface Mounting (Driver should be Inside the Luminaire)
1474Minimum lumen output 4320 lm
1475Minimum lumen output 4800 lm
1476SITC of IP20, 1'X1' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution.operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , UGR (unified glare rating)<19, fliker free (current ripple should be below 5%), SDCM (standard deviation colour matching)<5 life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
1477Recessed Mounting
1478Minimum lumen output 2880 lm
1479Minimum lumen output 3600 lm
1480Surface Mounting (Driver should be Inside the Luminaire)
1481Minimum lumen output 2880 lm
1482Minimum lumen output 3600 lm
1483SITC of IP-20 LED Recessed Mounted, Round backlit & COB type LED Downlighter of Powder Coated diecast/Extruded Aluminium body including trim with aluminium deflector and construction as per IS:10322 with 2.5 KV surge protected Isolated driver with Short & Open circuit protection (Input 320VAC-48 hours protection, Input 350VAC-2 hours protection) having efficiency > 85%, operating voltage 140-270 V AC. System Lumen efficacy of ≥ 100 lm /watt, at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, UGR(Unified Glare Rating)< 19, Fliker free(current ripple should be below 5%), SDCM(Standard Deviation Color Matching) < 5, life time of minimum 50000 Burning Hours with 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
1484lumen output 550 lm to 770 lm
1485lumen output 880 lm to 1100 lm
1486lumen output 1320 lm to 1650 lm
1487Providing & Fixing of IP-65 Protected LED aviation obstruction light luminaire comprising of die cast aluminium alloy housingwith Polycarbonate enclosure having more than 200 No's Low Power LED's having minimum power consumption 15 watts complete in all respect.
1488aviation obstruction LED light luminaire 12/15 Watts
1489Providing & Fixing of IK07 IP65 protected Top/Bottom mounted LED Post top Luminarie top & bottom made of single piece construction powder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser and Aluminium anodised with powder quoted reflector. The System level Luminous efficacy ≥ 80 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . LED Driving output current <750mA as required.
1490Minimum lumen output 2800 lm Post top Luminarie
1491Minimum lumen output 3200 lm Post top Luminarie
1492Minimum lumen output 3600 lm Post top Luminarie
1493Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass with suitable lenses on LED / integrated lens diffuser to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated metal case potted driver as a unique BIS R number (as per IS 15885) having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate(Fitting & driver both have separate BIS R number). The System level Luminaire efficacy >=130 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , LED driving output current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K as required.
1494High Power LED Flood Light Minimum lumen outpu 3900 lm
1495High Power LED Flood Light Minimum lumen output 6500 lm
1496High Power LED Flood Light Minimum lumen output 10400 lm
1497High Power LED Flood Light Minimum lumen output 13000 lm
1498High Power LED Flood Light Minimum lumen output 15600 lm
1499High Power LED Flood Light Minimum lumen output 19500 lm
1500High Power LED Flood Light Minimum lumen output 23400 lm
1501High Power LED Flood Light Minimum lumen output 26000lm
1502High Power LED Flood Light Minimum lumen output 32500 lm
1503High Power LED Flood Light Minimum lumen output 39000 lm
1504High Power LED Flood Light Minimum lumen output 45500 lm
1505High Power LED Flood Light Minimum lumen output 52000 lm
1506High Power LED Flood Light Minimum lumen output 65000 lm
1507Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED/ integrated lens diffuser & should be High power LED of 3 to 5 watt each . The System efficacy >=125 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current <750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs as required.
1508LED Street Light fixture with Minimum lumen output 2500 lm
1509LED Street Light fixture with Minimum lumen output 3750 lm
1510LED Street Light fixture with Minimum lumen output 5625 lm
1511LED Street Light fixture with Minimum lumen output 7500 lm
1512LED Street Light fixture with Minimum lumen output 8750 lm
1513LED Street Light fixture with Minimum lumen output 11250 lm
1514LED Street Light fixture with Minimum lumen output 12500 lm
1515LED Street Light fixture with Minimum lumen output 15000 lm
1516LED Street Light fixture with Minimum lumen output 18750 lm
1517LED Street Light fixture with Minimum lumen output 22500 lm
1518LED Street Light fixture with Minimum lumen output 26250 lm
1519Providing & Fixing of IK08 IP65 protected 600-800 mm height LED Bollard Luminarie with base plate made of powder coated die cast aluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 80 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<20% and input Voltage range of 90-270V AC at 50Hz. System life of 30000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as per engineers choice. LED driving output current <750mA. as required.
1520Minimum lumen output 800 lm Bollard
1521Minimum lumen output 980 lm Bollard
1522Providing & Fixing of IK08 IP66 / IP67 protected Rectangular shape LED Step Luminarie made of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 60 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<20% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . driver current <750mA as required.
1523Minimum lumen output 450 lm Step light
1524Minimum lumen output 630 lm Step light
1525Minimum lumen output 800 lm Step light
1526Providing & Fixing of IK08 IP65 / IP66 protected LED Up - Down Luminarie Wall / Surface mounting made of powder coated die cast alluminium housing with with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 80 Lumen/W. COB LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as per engineers choice. LED driving output current <750mA. as required.
1527Minimum lumen output 800 lm Up-Down Luminary
1528Minimum lumen output 1300 lm Up-Down Luminary
1529Minimum lumen output 2150 lm Up-Down Luminary
1530Providing and fixing of fuse box size 250(H) x 200(W) x 150(D) mm fabricated of 1.6mm MS sheet with hinged cover, dust and vermin proof, rubber gasket, locking arrangement, duly holded with 2 nos pole clamps of 20 mm x 3 mm flat with nut and bolts, complete with anticorrosive treatment, finished with two coat of approved enamel paint. The box shall be provided with 2 / 4 nos copper bus bar 125 x 20 x 3 mm with brass screws suitable supports,earth terminal, inter connection, knock outs for 20 / 25 mm cable gland, 1 no. 6 Amp MCB complete in all respect.
1531Providing and fixing of IP 65 protected Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window, PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0 sq.mm heavy duty connector, earth terminal, complete in all respect.
1532125 mm X 200 mm X 122 mm
1533160 mm X 225 mm X 100 mm
1534200 mm X 200 mm X 122 mm
1535225 mm X 225 mm X 100 mm
1536Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required.
153720 mm Dia.
153825 mm Dia.
153932 mm Dia.
154040 mm Dia.
1541Providing & Fixing of IP - 65 protected impact resistant polycarbonate / Polysterene enclosures with knock out for cable entry/out including fixing with nut, bolt, fatner etc as required complete in all respect of following sizes.
1542180 x 180 x 91 mm
1543250 x 200 x 115 mm
1544300 x 450 x 132 mm
1545320 x 440 x 179 mm
1546320 x 640 x 179 mm
1547Providing & Fixing of IK10/ IP66 protected pole mount LED Post top Luminarie top & bottom made of single piece construction powder coated pressure die cast alluminium housing with High purity PC diffuser, downward illumination to control light pollution. The System level Luminous efficacy ≥ 120 Lumen/W. SMD LEDs is to be used, System CRI>/=70, CCT: 4000/5700 K. Driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.95, THD<10% and with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety, driver should be Phase to phase protection of 440 V for 4 Hrs. System life of 50000 Burning hours with 70% of Initial Lumens maintained . LED driving current <750mA. Mounting pole diameter 060mm, The Luminaire dimension min Dia 450mm x 200mm(H). including making connections etc. as required.
1548Minimum lumen output 5000 lm Post top Luminaire
1549Minimum lumen output 6000 lm Post top Luminaire
1550Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, U/UTP (Unscreened/Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by LSZH Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies ranging from 250 to 500 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect.
1551Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with HDPE, U/UTP (Unscreened/Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Outdoor ECCS armoured Cable as per latest ammendments of ANSI/TIA/EIA-568 C.2 & ISO/IEC 11801 2nd Ed, The copper conductors should be balanced twisted in pairs, seperated by a cross divider & protected by PVC outer jacket of UV resistant. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies ranging from 250 Mhz to 500 Mhz. Should meet IEEE 802.3af & IEEE 802.3at for POE applications. Cable Should support Ethernet 10GBASE-T according to the standards. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required.
1552Supply and Installation of unshielded/360 degree shielded PCB based Information outlets made of high impact plastic body with ABS, Flammability rating UL 94 V-0 with provision for protection against dust in jack or Faceplate, suitable for Cat 6/6A application complying to latest amendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat 6/6A standards at frequencies 250/ 500 MHz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have toolless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA 568 C.2 & ISO/IEC 11801 or latest standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocol (VOIP) Specifications in existing modular/MS Boxes along with necessary connections as required. All as per pre approved by Engineer in charge.
1553Cat 6, Un-sheilded Information Outlet
1554Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture with dust cover, material should be High-impact, flame retardant, thermoplastic, UL listed material, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge.
1555Single Aperture
1556Dual Aperture
1557Supply, Installation, Testing and Commissioning of Rack mounted 19\\" 1U, 24 Port loaded, CRS chasis, powder coated, sheet steel, High-impact, flame retardant, thermoplastic, UL Listed, Modular Patch Panels with Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required. All as per pre approved by Engineer in charge.
1558Modular Patch Panel Loaded with Cat -6 I/O
1559Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).
1560Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord
15610.50 Mtr
15621 Mtr
15632 Mtr
15643 Mtr
1565Supply, Drawing and OLTS Testing, of OM2 Multi mode (50/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1-2 E1, E3,E11, F1/ EN 50173-1/ EN 187 000/ IEC 60974-2, 2-20, 2-21/ ITU G.651 with outer sheath, cable should be used for LAN and WAN back bones, for indoor/outdoor installations these sheathed cable be placed in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect.
15666 fiber
156712 Fiber
1568Supply, Installation, OTDR/OLTS Testing & Fusion Splicing of Fiber OM2 Multimode Pigtail (50/125 µm) made of glass fiber optic, should be fitted at one end with any one type of single SC/LC/SN/CS type connector in acc., as per latest ammendments of TIA/EIA 569 Standard Specification as per requirments complete in all respect.
1569Supply, Installation, & Testing of Indoor duplex OM2 Multimode patch cord (50/125 µm made of glass fiber optic with LSZH jacket, 2.0x4.1 mm, Multimode ITU G 651 Mounted on both sides with SC/LC/SN/CS type Duplex connectors in acc. with IEC 61754-20. Zirconia (ceramic) ferrule with a PC polished endface geometry, connectors should be tuned in accordance with IEC 61755-3-1 and qualified in acc. with IEC 61753-1 for category U (uncontrolled environment, duplex clip and white plastic dust cover, should comply to delta IL < 0.2 dB after 500 mating cycles, there should be an optional Visual coding, mechanical coding and lock protection on the patch cords which can be added on later stage. patch cords's performance should be acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, as per requirements.
15701 Mtr
15712 Mtr
15723 Mtr
15735 Mtr
1574Supply, Installation, & Testing of 19\\" 1U Rack Mounted/ surface mounted aluminum/ CRCA powder coated, OM2 multimode glass Fiber Optic Cable Patch panel/LIU loaded with flangeless/screwable adapters for SC/LC/SN/CS type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleeves, screws, nuts to install the panel for rackmount applications as per requirement. All as per pre approved by Engineer in charge.
1575Multi Mode LIU 6 Ports
1576Multi Mode LIU 12 Ports
1577Multi Mode LIU 24 Ports
1578Supply, Drawing and OLTS Testing, of stranded OS2 Single mode (9/125 µm) glass optic fiber cable G652D as per latest ammendments of TIA/EIA 568/ISO/IEC with outer sheath, cable should be used for LAN and WAN back bones, for indoor/outdoor installations these sheathed cable be placed in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect.
15796 fiber
158012 Fiber
158124 Fiber
1582Supply, Installation, OTDR / OLTS Testing & Fusion Splicing of Fiber Singlemode Pigtail (9/125 µm (OS2) made of glass fiber optic, with semi-tight buffer PA/PBT, Ø 0.9 mm, yellow, singlemode G652.D (9/125 µm (OS2), should have length of min 1.5m, should be fitted at one end with any one type of single SC/LC/SN/CS type connector in acc. with IEC 61754-20, Should be delta IL < 0.2 dB after 500 mating cycles, It should be Zirconia (ceramic) ferrule with a PC polished endface geometry connector qualified in acc. with IEC 61753-1 for category U (uncontrolled environment). and qualified in acc. with IEC 61753-1, Performance acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, Standard Specification as per requirements.
1583Supply, Installation, & Testing of Indoor duplex Singlemode patch cord (9/125 µm (OS2) made of glass fiber optic with LSZH jacket, F8 2.0x4.1 mm, yellow, singlemode G652.D (9/125 µm (OS2) Mounted on both sides with SC/LC/SN/CS type Duplex connectors in acc. with IEC 61754-20. Zirconia (ceramic) ferrule with a PC polished endface geometry, connectors should be tuned in accordance with IEC 61755-3-1 and qualified in acc. with IEC 61753-1 for category U (uncontrolled environment, duplex clip and white plastic dust cover, should comply to delta IL < 0.2 dB after 500 mating cycles, there should be an optional Visual coding, mechanical coding and lock protection on the patch cords which can be added on later stage. patch cords's performance should be acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, as per requirements.
1584Single Mode Patch Cord 1 Mtr.
1585Single Mode Patch Cord 2 Mtr.
1586Single Mode Patch Cord 3 Mtr.
1587Single Mode Patch Cord 5 Mtr.
1588Supply, Installation, & Testing of 19\\" 1U Rack Mounted/ surface mounted aluminum/ CRCA powder coated, OS2 Single mode glass Fiber Optic Cable Patch panel/LIU loaded with flangeless/screwable duplex adapters for SC/LC/SN/CS type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleeves, screws, nuts to install the panel for rackmount applications as per requirement complete in all respect. All as per pre approved by Engineer in charge.
15896 Ports
159012 Ports
159124 Ports
1592Supply & Installation of IP-20 & IK-08 , Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with 'U'Marking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19\\" angles with wall mounting provision on wall. Accessories like: 1 No of 19\\" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19\\" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.
15936 U Rack with Width 600 mm & Depth 400 mm + 100 mm
15949 U Rack with Width 600 mm & Depth 400 mm + 100 mm
159512 U Rack with Width 600 mm & Depth 400 mm + 100 mm
159615 U Rack with Width 600 mm & Depth 400 mm + 100 mm
1597Supply & Installation of IP-20 & IK-08 , Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet,Vertical Mounting Rail 1.6 MM with 'U'Marking, front sturdy sheet steel frame folded from one piece and welded with 5mm toughened glass door, with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, Set of 75 mm height 4 castors, 2 of which have brakes, Accessories like: 5 Nos of 19\\" 1U Horizontal Cable manager, 2 Nos of vertical cable managers, 1 no. Keyboard Tray, 4 Nos of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 2 No of 19\\" 1U, mountable socket strips with 6 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable complete in all respect.
159817 U Rack with Width 600 mm & Depth 800 mm
159922 U Rack with Width 600 mm & Depth 800 mm
160027 U Rack with Width 600 mm & Depth 800 mm
160136 U Rack with Width 600 mm & Depth 800 mm
160242 U Rack with Width 600 mm & Depth 800 mm
160342 U Rack with Width 800 mm & Depth 1000 mm with 3 no. Heavy Duty Sliduing Drawer
1604Supply , Installation, Testing and Comissioning of Unmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100/1000 MBPS auto-negotiation RJ45 ports, IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect.
16058 Port
160616 Port
160724 Port
1608Supplying, installation, Testing and commissioning of following capacity 8 port Non POE Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of -5 0C to +50 0C. Jumbo frame: 10KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping and server screening, IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP, TLS, TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1,v2c, v3 and SNMP Traps. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
1609Supplying, installation, Testing and commissioning of following capacity 8 port PoE Layer 2 Indoor Network Switch having features and specifications etc. as mentioned here under: At least 8 X RJ-45 PoE/PoE+ Gigabit Ethernet Ports and additional 4 X 1G SFP Ports with non-blocking architecture by having Switching capacity of min. 24Gbps and packet forwarding rate of 17Mpps or higher, console port, 16K MAC table, IPv4 and IPv6 ready, IGMP snooping v1, v2, v3, DHCP,DHCP Relay, NTP/SNTP, SNMPv1, v2 C v3, TELNET/ SSH, LACP, STP, RSTP, MSTP, ERPS. VLAN: Port based, Mac based, IP subnet based, tag based, protocol based. Ǫ- in Ǫ, L2/L3 ACL, 1588v2 Precision Time Protocol HW- Based E2E Transparent clock, SNTP, TFTP, SNMP, Radius, Syslog. Dual DC Power input, IP30 rated, DIN Rail, -5° to 70° C operating temperature. Certificate: UL, CE, FCC, NEMA-TS2, IEC/MIL-STD for Shock , Vibration & Drop Certificate. OEM Should have Certificate for Industrial Cyber Security Capability IEC- 62443-4-1:2018, ISO 45001, ISO 27001 and ISO 14001 Certified or Equivalent Indian Certificate. OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
1610Supplying, installation, Testing and commissioning of following capacity 24 port Non POE Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snooping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.0Ǫ,Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snooping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.0P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.0p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.0ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
1611Supplying, installation, Testing and commissioning of following capacity 24 port POE Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snooping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.0Ǫ,Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snooping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.0P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.0p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.0ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
1612Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required.(For Each SM Fiber) all switches & related Fiber modules should be of same make & category for seamless integration with each other of Enterprise class.
16131G SFP Single Mode/Multi Mode
16141G Copper SFP
161510 G SFP + Single Mode/Multi Mode
1616Supply, installation, Testing and Commissioning of 1000 base-LX/LH single mode/Multi mode fibre to 1000 base-T copper giga bit , Media Convertor complete as required complete in all respect.
1617Fiber Fusion Splicing with OTDR/OLTS Testing of Fiber Single/ Multi mode (per splice) of glass Fiber Optic Cable including jointer box and cleaning the cable and making splice as per standard practice complete in all respect.
1618Supplying, Installation, Testing and commissioning of indoor Wireless Access Point for Low Density use having features and specifications etc. as mentioned here under - Dual-band Wi-Fi6 (802.11ax) 574Mbps (2.4GHz) + 1200Mbps (5GHz), WI-FI 6 Certified, 1 x RJ45 console port, 1G LAN POE Port, factory reset, WPA/WPA2/WPA3TM Personal/Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS server, SNMP, Customizable Captive Portal, Auto Channel, Works as Access Point, WDS, WDS with AP, Wireless Client, Web (HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast Roaming/Band Steering, Supports enhanced security – WPA-PSK/WPA2- PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and MAC/ IP ACL for networks, Certifications: MTCTE, CE, FCC. Should also work as Standalone and must be Compatible with S/W & H/W Controller with addtional features like - Real-Time Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role-Based Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF Management and Bandwidth Optimization, Multi-SSID and Captive Portal Authentication.OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
1619Supplying, Installation, Testing and commissioning of indoor Wireless Access Point for High density use having features and specifications etc. as mentioned here under- WiFi6 802.11ax 574Mbps (2.4GHz) + 2402Mbps (5GHz), WIFI 6 Certified, 1 x RJ45 console port, MG 2.5G LAN POE Port, factory reset, WPA/WPA2/WPA3TM Personal/Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS server, SNMP, Customizable Captive Portal, Auto Channel, Works as Access Point, WDS, WDS with AP, Wireless Client ., Web (HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast Roaming/Band Steering, Supports enhanced security – WPA-PSK/WPA2- PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and MAC/ IP ACL for networks, Certifications: MTCTE, CE, FCC. Works as Standalone, Compatible with S/W & H/W Controller with addtional features like - Real-Time Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role-Based Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF Management and Bandwidth Optimization, Multi-SSID and Captive Portal Authentication.OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
1620Supplying, Installation, Testing and commissioning of Outdoor Wireless Access Point having features and specifications etc. as mentioned here under - WIFI 6 Certified, 1 x RJ45 console port, MG 2.5G LAN POE Port, factory reset, 4 x internal antennas, the transmission coverage of shall be minimum 80 meters in radius, AP should have transmission power minimum of 22 dBm, The AP shall provide a minimum of 29 dBm EIRP for both 2.4 GHz and 5 GHz frequencies. Field deployment shall be with EIRP as per regulatory guidelines, AP shall have dual-band Omni-directional Antenna, either internal or external. Field deployment shall be with EIRP as per the WPC guideline, WPA/WPA2/WPA3TM Personal/ Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS server, SNMP, Customizable Captive Portal, Auto Channel, Works as Access Point, WDS, WDS with AP, Wireless Client, Web (HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast Roaming/Band Steering, Supports enhanced security – WPA- PSK/WPA2-PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and MAC/ IP ACL for networks, IP68 water/dustproof standard, 6KV Surge Protection; 4KV ESD Protection (contact), 6KV (air), Operating ambient temperature (-5~50 °C), Grounding point support, IEC 60601-1-2 EMC Medical Electrical Equipment Testing and Certification, EN50121-1 & EN50121-4 for Wireless Application. Certifications:MTCTE, CE, FCC. Works as Standalone, Compatible with S/W & H/W Controller with additional features like - Real-Time Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role- Based Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF Management and Bandwidth Optimization, Multi-SSID and Captive Portal Authentication. OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. as required.
1621Supplying, Installation, Testing and commissioning of indoor Wireless Controller having features and specifications etc. as mentioned here under- The network controller shall be a dedicated hardware appliance designed for centralized management of wireless access points, It must support the management of up to 500 networking devices, The system should be on-premise, ensuring data privacy and complete control over network configurations. It must include an intuitive user interface for real-time monitoring, device discovery, firmware upgrades, scheduling, and mass configuration deployment. Features such as role-based administration, multi-site management. AP to controller communication shall be use of industry standards-based (IEEE or IETF) CAPWAP or any tunneling protocols as per guidelines of DoT.The controller should support Layer 2 and Layer 3 device discovery, VLAN configuration, MAC ACL groups, IGMP snooping, and bandwidth optimization. Automatic radio frequency (RF) management and access policy enforcement are required for reliable wireless performance. The solution must offer a comprehensive dashboard with network topology, floor plan views, client and device lists, and alert notifications. For authentication, it should support a range of methods including local database, external RADIUS, LDAP, and passcode or MAC-based access. It should provide detailed traffic analytics, logs, and customizable reporting for network visibility and planning. Firmware and configuration backup and restoration functions must be available, with USB- based log storage supported. Physical specifications should include a compact form factor with a minimum of one 2.5G Ethernet port and USB 3.0 port, and it must be MTCTE,CE, FCC, and RoHS certified. The controller should operate reliably within a 0°C to 40°C temperature range and 10–90% non-condensing humidity. /Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
1622Supply& laying of 8 core shielded cable for extension cable for contribution unit /control unit interconnection making connection testing etc complete as required.
1623Supply & Laying of 2 Core size 0.5 sqmm copper shielded Cable for connectings Microphones with related conduits / fittings / termination, etc complete as required.
1624Supply, Installation, Testing & Commissioning of 2 input 4 output hdmi splitter complete as required.
1625Supply, Installation, Testing & Commissioning of High−performance 15 meter HDMI male to HDMI male cable Wall plate for the interoperability in all respect to etc complete as required.
1626SITC of BIS approved Line Interactive UPS having 0.6 Output factor, Built In AVR & SMF Batteries. Input Voltage range of 160V-280V, 1 Phase; 50 Hz and Output voltage of 230V±10%; 50Hz±1Hz. UPS should have Under / Over voltage, Spike, Overload, Short circuit protection and give audible alarm during Battery mode, Low battery, Overload, Fault conditions. UPS should be Genset compatible,shall have auto resart & cold start feature and Indian type output sockets. etc. as required.
1627600VA LI UPS with 84 VAH Battery
16281000VA LI UPS with 168 VAH Battery
1629S & F of 12V VRLA Lead Acid Sealed maintenance free (SMF) batteries of following capacity with Warranty of 2 years
16307.0 AH
163112 AH
163218 AH
163326 AH
163428 AH
163534 AH
163642 AH
163765 AH
1638100 AH
1639120 AH
1640150 AH
1641Labour charges for installation of submersible motor pump set including lowering/ delowering of pipes, cables, accessories etc. in tube-well/ open well complete including T&P, transportation of tripod, chain pulley block & any other material required for this purpose complete in all respect.
1642Lowering only
1643Delowering only
1644Delowering and Lowering
1645Providing & Fixing of HDPE pipe Confirming to IS:4984:2021 for water supply suitable for submersible & jet pump with required fittings ie socket, elbows, tee etc. complete in all respect.
1646for vertical installation
164740 mm OD 6 kg / cm2
164850 mm OD 6 kg / cm2
164963 mm OD 6 kg / cm2
165075 mm OD 6 kg / cm2
165190 mm OD 10 kg / cm2
1652for Horizontal installation
165340 mm OD 4kg/ cm2
165450 mm OD 4 kg/ cm2
165563 mm OD 4 kg/ cm2
165675 mm OD 4 kg/ cm2
165790 mm OD 6 kg/ cm2
1658SITC of Single Stage, water cooled, High Speed (2880 RPM), Horizontal, Centrifugal, Openwell Submersible pumps set pre filled with coolent water and fitted with mechanical seal. The motor body of single phase pump shall be of SS and rest of all shall be of cast iron. Shaft of three phase pump shall be of SS 410 grade. All casting parts should be cathod electro deposition (CED) coated. Motor winding shall be 100% copper wire material. Dynamically balanced rotating parts to ensure min. vibration etc. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect.
16590.5 HP, 1-Ø, (7 -18) Mtr, (180 - 20) LPM
16601.0 HP, 1-Ø, (12 -27) Mtr, (200- 30) LPM
16611.5 HP, 1-Ø, (18 -33) Mtr, (160-35) LPM
16622.0 HP, 1-Ø, (9 -21) Mtr, (475 - 130) LPM
16633.0 HP, 3-Ø, (17 -27) Mtr, (680 - 250) LPM
16645.0 HP, 3-Ø, (13 -36) Mtr, (995-200) LPM
1665SITC of Monoblock closed coupled motor pump set with TEFC motor, motor should be IP55-F class and IE2 efficiency for monobloc, with carbon steel /SS-410 shaft, Mechanical seal, Single/Three phase Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively and Dynamically balanced rotating parts to ensure min. vibration etc. complete in all respect.
16660.5 HP, 1-Ø, (8 - 26)Mtr, (50-10) LPM (SS Impellor & SS Body)
16670.5 HP, 1-Ø, (8 - 26)Mtr, (50-10) LPM ( Bronze impeller & CI Body)
16681.0 HP, 1-Ø, (10-30)Mtr, (76-28) LPM ( Bronze impeller & Aluminium Body)
16691.0 HP, 1-Ø, (10-30)Mtr, (76-28) LPM ( Bronze impeller & CI Body)
16701.5 HP, 1-Ø, (15-40)Mtr, (78-15) LPM ( Bronze impeller & CI Body)
16712.0 HP, 1-Ø, (6-27)Mtr, (250-100) LPM ( Bronze impeller & CI Body)
16722.0 HP, 3-Ø, (6-27)Mtr, (250-100) LPM ( Bronze impeller & CI Body)
16733.0 HP, 3-Ø, (12 - 26)Mtr, (470-275) LPM ( Bronze impeller & CI Body)
16745.0 HP, 3-Ø, (19-44)Mtr, (550-300) LPM ( Bronze impeller & CI Body)
1675SITC of Dewatering Submersible Motor Pump set, motor should be IP68/F class/IE3class suitable to handle raw sewage suitable for Minimum 25 mm solid and CI Impellor, CI body & housing ( as per IS-210 standard) and SS shaft, Double mechanical seal etc. as required. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively 10 Mtr cable length etc. complete in all respect. The submersible pumpset shall be suspended with chain for ease of connection and disconnection from discharge pipe assembly.
16761.0 HP, 3-Ø, (5 - 10)Mtr, (350 - 50) LPM
16772.0 HP, 3-Ø, (8 - 15)Mtr, (480 - 50) LPM
16783.0 HP, 3-Ø, (8 - 18)Mtr, (800 - 76) LPM
16795.0 HP, 3-Ø, (10 - 20)Mtr, (940 - 75) LPM
1680SITC of Drain Sewage pump Non-clog, Semi-open, single vane with alloy cutter fully floodable submersible pump motor should be IP68/F class/IE3, suitable to handle raw sewage suitable for Minimum 25 mm solid with CI Impellor, CI body & housing, SS shaft, Double Mechanical seal etc. as required. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively, 10 Mtr cable length etc. complete in all respect. The submersible pumpset shall be suspended with chain for ease of connection and disconnection from discharge pipe assembly.
16811.0 HP, 3-Ø, (4 - 12)Mtr, (400 - 45) LPM
16822.0 HP, 3-Ø, (8 - 16)Mtr, (375 - 40) LPM
16833.0 HP, 3-Ø, (8 - 22)Mtr, (590 - 80) LPM
1684SITC of Pressure boosting pump with MS Tank, pressure switch, pressure gauge, and all standard fittings fully automatic ON / OFF system, 2900 RPM with stainless steel casing, & impellor suitable for following capacity complete in all respect.
16850.5 HP ( 12 - 26 ) Mtr, (50 - 10 ) with 8 Ltr tank
16860.75 HP -0.90 HP ( 10 - 34 ) Mtr, (72 - 5 ) LPM with 24 Ltr Tank
16871.0 HP ( 10 - 38 ) Mtr, (76 - 8 ) LPM with 24 Ltr Tank
16881.5 HP ( 18-44 ) Mtr, (10-78 ) LPM with 35 ltr tank
1689Providing & Fixing of CI foot valve complete in all respect as required.
169050/ 60 mm
169180/ 100 mm
1692Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with socket,elbow,tee, flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect. ( If Pipe Laid Underground Excavation and refilling cost will be paid extra)
169332mm dia
169440 mm dia.
169550 mm dia.
169665 mm dia.
169780 mm dia.
1698100 mm dia.
1699SITC of IP 54 OEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Coordination Chart and made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection(for three phase pumps), Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps, 2P/4P MCB etc. suitable for following rating motors complete in all respect.
1700For single phase Submersible / Monoblock pump
17010.5 HP to 1.5 HP (DOL starter)
17022.0 HP to 3.0 HP (DOL starter)
17035.0 HP (DOL starter)
1704For Three phase Submersible / Mono block pump
1705Upto 3.0 HP ( DOL starter )
17063.0 HP to 5.0 HP ( DOL starter )
17077.5 HP to 10.0 HP ( DOL starter )
17083.0 HP to 5.0 HP ( Star / Delta starter )
17097.5 HP to 10.0 HP ( Star / Delta starter )
171012.5 HP to 15.0 HP ( Star / Delta starter )
171120.0 HP ( Star / Delta starter )
171225.0 HP ( Star / Delta starter )
171330.0 HP ( Star / Delta starter )
1714SITC of Wall mounting cubical type Starter panel made out of 1.6 mm thick sheet steel powder coated enclosure designed as per Switchgear OEM type -2 coordination chart and suitable for operation of following cfm range Air Washer's Blower motor, pump comprising of over load protection relay, short circuit & single phasing protection, ON / OFF push buttons, ammeter, voltmeter, indicating lamps, MCB etc. complete in all respect. All as per pre approved by Engineer in charge.
1715Upto 7500 cfm
1716more than 7500 cfm to 15000 cfm
1717more than 15000 cfm to 25000 cfm
1718more than 25000 cfm to 25000 cfm
1719Supply , Installation, Testing and Comissioning of wall mounted remote ON/OFF Push Button station for AHU/Air washers made out from powder quoted CRCA sheet of 16 SWG , illuminated ON/OFF push button including making connections etc as required complete in all respect. All as per pre approved by Engineer in charge.
1720P & F of Fire retardent flexible canvass connection made of fibreglass weave having silver grey silicon rubber coating, of height 200 mm with sufficient fold to avoid transmission of vibration with GI frame ,Gasket Nut Bolts for air cooling Plants/AHU/FCU etc as required.
1721Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes.
172220 mm
172325 mm
172432 mm
172540 mm
1726Supply, Fixing and testing of following capacity IS:8448 marked wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrial plug top making connection etc complete in all respect.
17273 kVA
17284 KVA
17295 kVA
1730Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia
173150 mm dia per running inch length
1732100 mm dia per running inch length
1733150 mm dia per running inch length
1734200 mm dia per running inch length
1735Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge.
1736Supply & fixing MS powder coated stand suitable for 2.5/3.0/4.0 Tr outdoor type of Split/Ductable/Tower AC. All as per pre approved by Engineer in charge.
1737SITC of Condensate water Drain pump suitable to Install with Existing Split type AC Indoor unit , single phase, 230V, including all acessories of pump like discharge tube, filter, reservoir etc. as required.
1738SITC of Interconnecting refrigerant copper pipe for split/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including class 'O' Nitrile rubber sleeves (size as per item no. 22.43),7 mil Glass Cloth with 3 coats of anti UV paint (on area which is exposed to weather) chase cutting, supports, making good the same with sand cement plaster etc. as required.
1739Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. .
1740Earth work in excavation/ by mechanical means (Hydraulic Excavator) / Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sum on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed:
1741Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement Mortar 1:6 ( 1-Cement : 6-Sand).
1742Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
1743Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level
17441:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
17451:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
17461:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1747Plaster on new surface on wall in cement sand mortar 1:4 including racking of joints etc. complete fine finish :
174820mm thick
174912mm thick
1750Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding:
1751New work (Two or more coats applied @ 3.84 kg/10 sqm).
1752Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more required complete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of size complete in all respect. .
1753Gravelling of Transformer / RMU Yard with 100 mm Height Gravels of Size 20 to 25 mm including leveling, Dressing etc. as Required.
1754SITC of pressure switches of pressure range 3 to 15 Bar for Main, Jockey, Terrace pump and Diesel pumps, Etc. as Required ( Control Cable from Pressure switch to Panel to be Paid Extra ).
1755Providing and fixing 20/25 mm dia. (PN - 1.6, Type-S1, Flanged, ISI marked) air release valve confirming to IS - 14845 : 2000 with Double Flange isolating valve (pressure rating PN 1.6) complete with 1 no. Matching Flanges (Minimum 10 mm thick), nuts, bolts, washers, gaskets etc as required.
1756SITC of UL listed and FM Approved Polyethelene vane type water flow switch with actuation & delay mechanism for sensitivity in the range of 4 to 10 GPM and suitable for installation in following sizes of Sprinkler pipe for a Static pressure rating up to 250 PSI including making connections, making hole in pipe for inserting the vane, steel U bolt for mounting etc. as required.
175780 mm Dia.
1758100 mm Dia.
1759150 mm Dia.
1760SITC of Pressure release valve of 50 mm dia, of CI body, with pressure setting range 7-15 kg/sqcm, on discharge header / Air Vessel, complete in all respect etc. as required.
1761Providing & fixing pressure transducer in M.S. Pipe line (pressure range 0 to 10 kg/cm2) suitable for 12 volts/24 volt DC. Including making connection etc. as required. ( Control Cable from Pressure Transducer to Panel to be Paid Extra ).
1762SITC of UL listed / FM Approved Brass Test and drain valve assembly for sprinkler system comprising of 3-position ( off, test and Drain ) ball valves with drain orifice having K-factor 5.6 and maximum working pressure 300 PSI and Inbuilt sight glass etc. as required of following size.
176325 mm Dia.
176450 mm Dia.
1765Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS 'C ' class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applications including cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick walls and making good the same. complete with painting of one coat of Red Oxide and two or more coat of synthetic enamel paint of Signal red shade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.).
176625 mm dia
176732 mm dia
176840 mm dia
176950 mm dia
177065 mm dia
177180 mm dia
1772100 mm dia
1773150 mm dia
1774200 mm dia, 6.0 mm thick
1775250 mm dia, 6.35 mm thick
1776300 mm dia., 7.0 mm thick
1777Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS 'C' class (Heavy) pipe conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applications in Existing trench with cement concrete block as supports including cutting, welding etc & forged steel fittings like elbows, tees, tapers, reducer with cleaning,wrapping and coating of the pipe with 4 mm thick tar based polymaric corrosion protection tape including applying uniform coat of cold pipekot primer as per IS; 10221 for protection against corrosion complete in all respect. ( Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs. & Excavation of Trench and refilling of trench to be paid extra).
177880 mm dia
1779100 mm dia
1780150 mm dia
1781200 mm dia, 6.0 mm thick
1782Providing and Fixing of 15 mm dia Bronze quartzoid bulb type sprinkler heads with Maximum working pressure 11.6 Kg / Sqcm and suitable for 68 degree centigrade rating standard response (UL Listed) chrome plated complete in all respect of the following type.
1783Pendant/ Upright type
1784Sidewall Sprinklers (ordinary)
1785Extended Throw Sidewall type .
1786Concealed type with Tin alloy fusible metal plate for temperature 57 degree Centigrade
1787Providing & fixing of UL listed 1.5 mm thick chrome plated Dual type MS Escutcheon plates fixed at junction of Sprinkler piping with the false ceiling.
1788Supply & Fixing of Fire Man's Axe with carbon steel head & rubber moulde handle usable upto 20 KV and confirming to IS :926 with length approx 0.4 M & weight min. 1.0 Kg.
1789Providing & fixing Stainless Steel pressure gauge with dial of 150 mm dia size and range 0 to 20 kg/sq.cm with 3 / 8 \\" BSP bottom entry , Ball valve , SS Syphon tube all fittings etc, duly calibrated before installation in MKS and FPS units, Accuracy Level +/- 1% including Making Drilling in Existing MS Pipe Etc. as required.
1790SITC of UL 7th edition/ FM certified Analog addressable Multi criteria photo thermal detector with mounting base & LED etc. as required.
1791SITC of EN 54 / VDS certified Analog addressable Multi criteria photo thermal detector with mounting base & LED etc. as required.
1792SITC of UL 7th edition and FM certified photoelectric Analog addressable Smoke detector with mounting base & LED etc. as required.
1793SITC of EN 54 / VDS certified photoelectric Analog addressable Smoke detector with mounting base & LED etc. as required.
1794SITC of UL 7th edition / FM certified Analouge Addressable type Rate of Rise Heat Detectors with mounting base & LED etc. as required.
1795SITC of EN 54 / VDS certified Analouge Addressable type Rate of Rise Heat Detectors with mounting base & LED etc. as required.
1796SITC of UL 7th edition / FM certified Intelligent Addressable type loop powered auto aligned Beam detector having a coverage area with a distance of min. 5 m and max. 100 m, with auto drift compensation feature including transmitter and receiver unit with remote test features etc including the cost of all accessories, mouting arrangement Etc. as required.
1797SITC of EN 54 / VDS certified Intelligent Addressable type loop powered auto aligned Beam detector having a coverage area with a distance of min. 5 m and max. 100 m, with auto drift compensation feature including transmitter and receiver unit with remote test features etc including the cost of all accessories, mouting arrangement Etc. as required.
1798SITC of UL 7th edition / FM certified Addressable type fault isolator with base for isolating shorted, dewired and loose circuits between two successive fault, isolators with automatic resetting arrangement etc. as required.
1799SITC of EN 54 / VDS certified Addressable type fault isolator with base for isolating shorted, dewired and loose circuits between two successive fault, isolators with automatic resetting arrangement etc. as required.
1800SITC of UL 7th edition / FM certified Addessable Manual Call point (MCP) with LED / FIRE Indication Etc. as required.
1801SITC of EN 54 / VDS certified Addessable Manual Call point (MCP) with LED / FIRE Indication Etc. as required.
1802SITC of UL 7th edition / FM certified Addressable sounder with strobe light, Direct powered from FACP with sound level 90 dB and programmable from the panel etc. as required.
1803SITC of EN 54 / VDS certified Addressable sounder with strobe light, Loop powered from FACP with sound level 90 dB and programmable from the panel etc. as required.
1804SITC of UL 7th edition / FM certified Addressable Control (input/output) modules/ Relay / Monitor Module for shutting down lifts, control of Mechanical ventilation fans, Hooters, AHU's, Acknoledgement of Sprinkler system with potential free contact monitoring Etc. as required.
1805SITC of EN 54 / VDS certified Addressable control (input/output) modules/ Relay / Monitor Module for shutting down lifts, control of Mechanical ventilation fans, Hooters, AHU's, Acknoledgement of Sprinkler system with potential free contact monitoring Etc. as required.
1806SITC of UL 7th edition / FM certified addressable automatic fire detector for monitoring of ventilation ducts which can perform alarm pattern analysis, with even response sensitivity for all fires with smoke development with 1 no outlet tube & with 1 no. analogue addressable Photo Electric type Smoke Detector with mounting base , address switch etc. as required.
1807SITC of EN 54 / VDS certified addressable automatic fire detector for monitoring of ventilation ducts which can perform alarm pattern analysis, with even response sensitivity for all fires with smoke development with 1 no outlet tube & with 1 no. analogue addressable Photo Electric type Smoke Detector with mounting base , address switch etc. as required.
1808SITC of Response Indicator for indicating the activation of the Remotely located Detector for Addressable / Conventional type Detectors Etc. as required.
1809Refilling of following fire Extinguisher including replacement of defective parts like discharge hosepipe, nozzle,Squeeze Grip valve, lock guard or pin,pressure gauge etc.as required complete in all respect.
18102 Kg ABC type
18114 Kg ABC type
18126 Kg ABC type
18139 Kg ABC type
18143.0 Kg CO2 gas type
18154.5 Kg CO2 gas type
181622.5 Kg CO2 gas type
18176.0 ltr foam type
18189.0 ltr foam type
1819Providing Manpower through Contracting agency for Supervision / Execution / Operation of various Electromechanical Installations. (one shift of 8 working Hrs per day for 26 Working Days in a month) on basis of minimum wages + VDA order Dt. 28.03.2025 Ministry of Labour and Employement Govt. of India
1820Engineer with B.Tech and1 Yrs, experience ,/Diploma Engineer with 3 Yrs. Experience in relevant field
1821Wireman, Electrician, Welder, Lineman, AC Mechanic, Fireman, , Supervisor, ELV technician or equivalent professional with ITI or Equivalent course and Experience of 2 years in relevant field )
1822Pump Operator, AC Plant Operator, ELV System Operator, Lift Operator, DG set Operator or any other services operator with experience of 3 years in relevant field )
1823Technical Helper Having basic Knowledge of E&M Services
1824Providing Manpower through Contracting agency for Supervision / Execution / Operation of various Electromechanical Installations. (one shift of 8 working Hrs per day ) on basis of minimum wages + VDA order Dt. 28.03.2025 Ministry of Labour and Employement Govt. of India
1825Engineer with B.Tech and1 Yrs, experience ,/Diploma Engineer with 3 Yrs. Experience in relevant field
1826Wireman, Electrician, Welder, Lineman, AC Mechanic, Fireman, , Supervisor, ELV technician or equivalent professional with ITI or Equivalent course and Experience of 2 years in relevant field )
1827Pump Operator, AC Plant Operator, ELV System Operator, Lift Operator, DG set Operator or any other services operator with experience of 3 years in relevant field )
1828Technical Helper Having basic Knowledge of E&M Services
1829Hire charges for Silent type D.G. Set, including change over switch. Control panel, 2 No. Pipe earthing etc. and excluding POL with skilled operator to operate system as and when etc as required. of following capacity:
1830125 KVA
1831for 1st day
1832From 2nd day onwards
1833250 KVA
1834for 1st day
1835From 2nd day onwards
1836Hire charges of Main service line for 3 phase connection upto 50 mtr. Length (without any joint) including meter board, panel/distribution Board and supports with skilled operator to operate system as and when etc as required.
1837above 25.0 sq.mm & upto 95 Sq.mm PVC insulated and Sheathed cable aluminium Armoured or Un-armoured as required.)
1838for 1st week
1839For 2nd / 3rd day
1840from 4th Day onwards
1841above95.0 sq.mm PVC insulated and Sheathed cable aluminium Armoured or Un-armoured as required.)
1842for 1st week
1843For 2nd / 3rd day
1844from 4th Day onwards
1845Supply and filling of POL for DG sets
1846Hire charges for following type of Airconditioners including copper piping , drain piping and electrical connections with skilled operator to operate system as and when etc as required.
18471.5 TR Split AC
1848for 1st day
18492nd day onwards
18502.0 TR Split AC
1851for 1st day
18522nd day onwards
18533.0 /4.0 TR Tower type split AC
1854for 1st day
18552nd day onwards
18565.0/5.5 TR ductable type Split AC
1857for 1st day
18582nd day onwards
18598.5 TR ductable type Split AC
1860for 1st day
18612nd day onwards
1862Rewinding of ceiling fan motor (starting and running winding) including all necessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. (New model ceiling fan)
1863900/1200 mm sweep (New model ceiling fan)
18641400 mm sweep (New model ceiling fan)
1865All sizes (Old model ceiling fan)
1866Labour charges for removing and refixing of Ceiling fan/ Exhaust fan from site
1867Charges for oiling, overhauling of ceiling fan, table fan, pedestal fan irrespect to the size of fan including removing,refixing of fan from site and testing etc. as required.
1868Fans w/o Removing & Refixing
1869Fans with Removing & Refixing at Suitable Location
1870Providing and Replacement of ball bearing of ceiling/ exhaust fan and refixing the same at suitable location as requiredand as per OEM recommendations. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material shall be retained by the contractor.
1871Provinding & Replacement of M.S. Shaft of ceiling fan. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1872P & Replacement of cover/ bearing seat of ceiling/ exhaust fan. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1873P & F Aluminium Blades (a set of 3 blades) duly painted and well finished 900/ 1200 mm. The material of the fan blade shall be of designation 31500B with condition HX6 aluminium alloy sheet confirming to IS 737/2008
1874P & F Aluminium Blades (a set of 3 blades) duly painted/ powder coated. ( 1400/ 1500 mm) The material of the fan blade shall be of designation 31500B with condition HX6 aluminium alloy sheet confirming to IS 737/2008
1875P & F of rubber gromet (fan insulator)
1876Providing and Replacement of Gun metal bush of ceiling/exhaust/cooler fan/ as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1877P & F 3 Speed rotary switch for Desert Cooler complete with testing etc as required.
1878P & Replacement of M.S. Shaft of fan motor for Desert Cooler/ exhaust fan. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1879P & replacement of supporting legs(4 no.) of vertical pump of desert cooler as required for Desert Cooler/ exhaust fan. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1880P & F of stud with nuts and washer for Desert Cooler/ exhaust fan.All the scrap material should be retained by the contractor.
1881Servicing and overhauling of 20\\" sweep desert cooler including oiling, greasing, painting of tank from inside with rubber paint after properly desmantling each assembly and refixing the same as required.
1882Painting of desert cooler with two coats of rubber paint inside of water tank and two coat of synthetic enamelled paint on both side of cooler body, fan body, grills etc.after cleaning with sand paper, complete in all respect as required.
1883Replacement of cooler pads (heavy) set of 3 no. of size 25\\" x 27\\"
1884P & F Brass float valve of weighing approx. 250 gm, 8\\" long rod,PVC ball of 4\\" dia. For desert coler as required.
1885P & F adjustable M.S.grill 20/22 gauge of size approx. 24\\" x 26\\" including painting etc. as required.
1886P & F aluminiun blade for 20'' desert cooler fan as required.
1887P & F outer/inner threaded PVC nipple 1/2\\" dia and 2\\" long
1888P & Replacement of pvc pipe of 1/2\\" size for vertical pump of desert cooler as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1889P & replacement of shaft for vertical pump of desert cooler as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1890Spray painting of ceiling fan of size 900/1200/ 1400/ 1500 mm with two coats of white/ brown enamelled paint after cleaning with sand paper. Filling etc. as required.
1891P & replacement of 4 nos. supporting legs of 20'' fan motor with rubber pads of desert cooler as required.Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1892P & replacement of high quality pvc distribution ' T 'and 3 no. elbow for cooler
1893P & F ISI marked waterproof plywood 6.0 mm thick including cutting, hardwares etc. as required.
1894P & F of ISI marked vertical pump suitable for 20\\" desert cooler including making connection testing etc. as required.
1895ISI marked vertical pump
1896P & F of submercible pump set suitable for 18/24 \\"Desert coolers.
1897P & F of submercible pump set suitable for 36 \\"Desert coolers.
1898P & F cooler fan motor suitable for 20\\" desert cooler including making connection testing etc. as required.
1899with copper winding Motor ISI Marked
1900with Aluminium winding Motor ISI Marked
1901Rewinding of Heavy duty Exhaust fan motor including all necessary material,The motor is to be wound taking no. of coils,turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1902300/ 380 mm sweep
1903450 mm sweep
1904600 mm sweep
1905Rewinding of 400 mm table fan/pedestal fan motor including all necessary material,The motor is to be wound taking no. of coils,turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1906Rewinding of single phase motor of 1400 RPM including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
19070.25 H.P. To 0.50 H.P.
19080.75 H.P. To 1.0 H.P.
19092.0 H.P.
1910Rewinding of three phase squirrel cage induction motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
19113.0 H.P.
19125.0 H.P.
19137.5 H.P.
191410.0 H.P.
191512.5 H.P.
191615.0 H.P.
1917Rewinding of motor of desert cooler pump with super enamelled copper wire, 'E ' class insulation material including removing,refixing,testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1918Rewinding of motor of desert cooler fan with super enamelled copper wire, 'E ' class insulation material including removing,refixing,testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1919Providing and replacement of heating element of blower type heat convector as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1920Providing and replacement of heating element rod of radiation type heat convector as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1921P & Replacement of overload protection of A.C./ Water cooler as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1922P & Replacement of thermostat of A.C./ Water cooler/fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1923P & Replacement of selector switch of 1.0/1.5/2.0 TR A.C Fan as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1924P & Replacement of starting relay of A.C/water cooler/fridge compressor as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1925P & Replacement of door liner of 165/200 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1926P & Replacement of door liner of 286/310 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1927P & Replacement of main liner of 165/200 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1928P & Replacement of main liner of 286/310 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1929P & Replacement of door gasket of 165/200 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1930P & Replacement of door gasket of 286/310 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1931P & Replacement of PVC/ acrylic vegetable basket of 165/200 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1932P & Replacement of PVC/acrylic vegetable basket of 280/310 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1933P & Replacement of glass/acrylic cover for vegetable basket of 165/200 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1934P & Replacement of glass/acrylic cover for vegetable basket of 286/310 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1935P & Replacement of PVC /acrylic bottle supporter of 165/200/ 286/310 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1936P & Replacement of aluminium bottle supporter of 165/200/ 286/310 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1937P & Replacement of PVC./acrylic freezer door of 165/200 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1938P & Replacement of PVC./acrylic freezer door of 286/310 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1939P & Replacement of door handle of 165/200/286/310 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1940P & Replacement of lamp of Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1941P & Replacement of PVC/acrylic chiller tray of 165/200 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1942P & Replacement of PVC/acrylic chiller tray of 286/310 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1943P & Replacement of fridge lock complete as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1944Spray painting of complete fridge (inside and outside ) of 165/ 200 Ltr. Capacity.
1945Spray painting of complete fridge (inside and outside ) of 286/310 Ltr. Capacity.
1946P & Replacement of fan motor of evaporator/ condensor complete as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1947S & F of capacitor of 230V/ 275V, 50Hz rating of plastic casing and terminals -Lugs or copper wire.
1948Starting capacitor
194920-30 micro farad
195040-60 micro farad
195160-80 micro farad
195280-100 micro farad
1953100-120 micro farad
1954120-150 micro farad
1955Running capacitor
19562.5/3.15 micro farad
19574.0 micro farad
19586.0 micro farad
19598.0 micro farad
196010.0 micro farad
196115.0 micro farad
196220.0 micro farad
196325.0 micro farad
1964P & Replacement of plastic/metallic sheet condensor holder suitable for ceiling fan/ exhaust fan /motor etc complete as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1965Rewinding of single phase/3phase submersible motor including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
19660.5 H.P. To 1.0 H.P.
19672.0 H.P.
1968Above 3.0 HP to 5.0 HP
1969From7. 5 HP to 10.0 HP
1970Repairing of submersible pump of with replacement of broken impellers ,diffuser,bush/bearing set , oil seal complete with testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
19710.5 H.P. To 1.0 H.P.
19722.0 H.P.
1973Above 3.0 HP to 5.0 HP
1974From7. 5 HP to 10.0 HP
1975Add: GST@18% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58636220
AUTHORITY Government Departments
TENDER VALUE 15.38 Lakhs
LAST DATE 28-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Rate Contract For Day To Day Electrical Work At Psychiatric Hospital Jaipur
Basic Detail
Tender No EE_PWD_Medical_NIT_32_2026_27
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 20 Nov 2026
Submission Date 28 Nov 2026
Open Date 30 Nov 2026
Finance
Tender Value 15.38 Lakhs
Tender Fee 500
EMD 30760
Exemption Available
Document List
03Rateconractcondition.pdf
b5278342-2e22-4c9e-afaf-d9bef0e936aa.html
BOQ_1075354.xls
Schedulecover3.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
pdf

03Rateconractcondition.pdf

html

b5278342-2e22-4c9e-afaf-d9bef0e936aa.html

xls

BOQ_1075354.xls

pdf

Schedulecover3.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender