Tender For New Office Building Bda, Bharatpur.
Tender Value
42.22 Crore
Estimated cost
Bid Submission
10 Dec 2026
19 days left
EMD
84.44 Lakhs
Bank guarantee accepted
Document Fee
2500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bharatpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for New Office Building Bda, Bharatpur.
BOQ
| Sl. No. | Item Description |
| 1 | RCC WorkSurface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish lead up to 50 Mtr. and lift up to 1.5 Mtr. : All kinds of soilAll site campus area Cleaning levealing surounding |
| 2 | Carriage of Materials: Earth, Sand, Lime, Morrum manure or sludge and Building Rubbish Stone metal (Grit and ballast etc.) For 5 Km.All site campus area Cleaning levealing surounding L=(216.98+192.995)/2Excavated |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soilRaft & FoundationGrid-1-5 & 10-14, A-LPorch 3-side Col. FoundationsRamp retain Wall RCC Foundation Grid-5-10, E-KAddDedLift & Sump pitLift & Sump Raft |
| 4 | Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof in. All kinds of soilFor Excavation Below 1.5m, 3 Addition LiftDed 1 liftDed upto 1.5mtr. |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift.Ramp Base For road & plinth Lvl. +600mmBuilding AreaSides Foundation |
| 6 | Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) .Basement Under FloorPorch 3-side Col. FoundationsWall |
| 7 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% Emulsion |
| 8 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. . M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).Raft & FoundationGrid-1-5 & 10-14, A-LPorch 3-side Col. FoundationsRamp retain Wall RCC Foundation Grid-5-10, E-KAddDedLift & Sump pitLift & Sump RaftLift & Sump Side Below RaftRamp BasePB BelowPlinth Beam/Connecting Beam at NGLBoth Side Porch Col.Front Entry Side Porch Col.Misc. |
| 9 | Random rubble dry stone Kharanja under floor.Raft & Foundation Bottom raftGrid-1-5 & 10-14, A-LPorch 3-side Col. FoundationsRamp retain Wall RCC Foundation Grid-5-10, E-KAdd DedLift & Sump pitLift & Sump RaftRamp Base |
| 10 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix Col. RCCBasement to NGL 0.00 Lvl.C-101,104,109,112, C-501,504,509,512 Size 500x500mmC-102,103,105,108,110,111,C-201,202,203,204,209,213,215,224,227,228,229,230,231,C-309,312,313,317,319,323,324,329,330,335,C-401,402,403,404,409,413,415,424,427,428,429,430,431,C-502,503,505,508,510,511, Size 500x750mmC-106,107,C-205,206,207,208,210,211,212,216,217,218,219,220,221, 222,225,226,C-331,332,333,334,C-405,406,407,408,410,411,412,416,417,418,419,420, 421,422,425,426,C-506,507 Size 500x900 mmC-310,311,314,316,320,321,322,325,326,327,328 Size 500x1200mmC-315,318 Size 500x1500 mmPorch Col. Foundation to Plinth Lvl.C-214,223,C-301,302,303,304,305,306,307,308,C-414,423 Dia=600 mmShare wallSW-301,302,303,306,307,308 Size 230x3460mmPlinth Beam/Connecting Beam at NGLSW-304,305 Size 230x3230Both Side Porch Col.Front Entry Side Porch Col.Basement Sump Pit SlabMisc. |
| 11 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design MixCol. RCCNGL 0.00 Lvl.to Basement SlabC-101,104,109,112, C-501,504,509,512 Size 500x500mmC-102,103,105,108,110,111,C-201,202,203,204,209,213,215,224,227,228,229,230,231,C-309,312,313,317,319,323,324,329,330,335,C-401,402,403,404,409,413,415,424,427,428,429,430,431,C-502,503,505,508,510,511, Size 500x750mmC-106,107,C-205,206,207,208,210,211,212,216,217,218,219,220,221, 222,225,226,C-331,332,333,334,C-405,406,407,408,410,411,412,416,417,418,419,420, 421,422,425,426,C-506,507 Size 500x900 mmC-310,311,314,316,320,321,322,325,326,327,328 Size 500x1200mmC-315,318 Size 500x1500 mmPorch Col.C-214,223,C-301,302,303,304,305,306,307,308,C-414,423 Dia=600 mm Share wallSW-301,302,303,306,307,308 Size 230x3460mmSW-304,305 Size 230x3230Basement Slab to GF SlabC-101,104,109,112, C-501,504,509,512 Size 500x500mmC-102,103,105,108,110,111,C-201,202,203,204,209,213,215,224,227,228,229,230,231,C-309,312,313,317,319,323,324,329,330,335,C-401,402,403,404,409,413,415,424,427,428,429,430,431,C-502,503,505,508,510,511, Size 500x750mmC-106,107,C-205,206,207,208,210,211,212,216,217,218,219,220,221, 222,225,226,C-331,332,333,334,C-405,406,407,408,410,411,412,416,417,418,419,420, 421,422,425,426,C-506,507 Size 500x900 mmC-310,311,314,316,320,321,322,325,326,327,328 Size 500x1200mmC-315,318 Size 500x1500 mmPorch Col. C-214,223,C-301,302,303,304,305,306,307,308,C-414,423 Dia=600 mmShare wallSW-301,302,303,306,307,308 Size 230x3460mmSW-304,305 Size 230x3230GF Slab to 1stC-101,102,103,104,109,110,111,112,C-201,202,203,204,228,229,230,231,C-313,317,319,323,324,329,330,335,C-401,402,403,404,428,429,430,431,C-501,502,503,504,509,510,511,512 Size 500x500mmC-105,108,C-205,206,207,208,209,210,211,212,213,215,216,217, 218,219,220,221,222,224,225,226,227,C-309,312,331,332,333,334,C-405,406,407,408,409,410,411,412,413,415,416,417, 418,419,420,421,422,424,425,426,427,C-505,508 Size 500x750mmC-106,107,C-310,311,314,316,320,321,322,325,326,327,328,C-506,507 Size 500x900 mmC-315,318 Size 500x1200mmPorch Col. Foundation to Plinth Lvl.C-214,223,C-301,302,303,304,305,306,307,308,C-414,423 Dia=600 mmShare wallSW-301,302,303,306,307,308 Size 230x3460mmSW-304,305 Size 230x32301st to 2nd F SlabC-101,102,103,104,109,110,111,112,C-201,202,203,204,205,208,209,212,213,215,218, 219,222,224,227,228,229,230,231,C-309,312,313,317,319,323,324,329,330,331,332,333,334,335,C-401,402,403,404,405,408,409,412,413,415,418,419, 422,424,427,428,429,430,431,C-501,502,503,504,509,510,511,512 Size 500x500mmC-105,106,107,108,C-206,207,210,211,216,217,220,221,225,226,C-310,311,320,321,322,325,326,327,328,C-406,407,410,411,416,417,420,421,425,426,C-505,506,507,508 Size 500x750mmC-314,315,316,318 Size 500x900 mmShare wallSW-301,302,303,306,307,308 Size 230x3460mmSW-304,305 Size 230x32302nd F to 3rd F SlabC-101,102,103,104,109,110,111,112,C-201–213,215–231,C-309,312,313,317,319,323,324,329–335,C-401–413,415–431,C-501–504,509–512 Size 500x500mmC-105,106,107,108,C-310,311,314,316,320,321,322,325,326,327,328,C-505,506,507,508 Size 500x750mmC-315,318 Size 500x900 mmShare wallSW-301,302,303,306,307,308 Size 230x3460mmSW-304,305 Size 230x3230Above Terrace C-101,102,103,104,109,110,111,112,C-201–213,215–231,C-309,312,313,317,319,323,324,329–335,C-401–413,415–431,C-501–504,509–512 Size 500x500mmC-105,106,107,108,C-310,311,314,316,320,321,322,325,326,327,328,C-505,506,507,508 Size 500x750mmC-315,318 Size 500x900 mmShare wallSW-301,302,303,306,307,308 Size 230x3460mmSW-304,305 Size 230x3230MummtyC-102,103,104,C-225,226,227,C-229,230,231,C-502,503,504,C-429,430,431 Size 500x500mmC-425,426,427, Size 500x750mmOH-TC-226,227,C-230,231, C-430,431 Size 500x500mmC-426,427, Size 500x750mmWall L=6.55*2+(5.23-0.23*2)*2Misc. |
| 12 | Providing and laying in position Ready mix concrete manufactured in fully automatic Batching Plant and transported to site in transit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. All works upto floor V floor M20 grade Design Mix by using cement as per codal provision.Raft & FoundationGrid-1-5 & 10-14, A-LPorch 3-side Col. FoundationsRamp retain Wall RCC Foundation Grid-5-10, E-KAddDedLift & Sump pitLift & Sump RaftCol. PedestalC-101,104,109,112, C-501,504,509,512 Size 500x500mmC-102,103,105,108,110,111,C-201,202,203,204,209,213,215,224,227,228,229,230,231,C-309,312,313,317,319,323,324,329,330,335,C-401,402,403,404,409,413,415,424,427,428,429,430,431,C-502,503,505,508,510,511, Size 500x750mmC-106,107,C-205,206,207,208,210,211,212,216,217,218,219,220,221, 222,225,226,C-331,332,333,334,C-405,406,407,408,410,411,412,416,417,418,419,420, 421,422,425,426,C-506,507 Size 500x900 mmC-310,311,314,316,320,321,322,325,326,327,328 Size 500x1200mmC-315,318 Size 500x1500 mmC-214,223,C-301,302,303,304,305,306,307,308,C-414,423 Dia=600 mmRamp Steching SlabReatin wall Basement L=(20.465+5.03+40.785+16.03+22.655+20.985+16.27)*2 +(9.87+8.27)*2+25.26+45Ramp Inside Basement side wallDed Col. Common AreaBasement Floor BelowLift Walls Basement FloorLift Walls Sump Wall Below RaftBasement SlabDed Shaft El.LiftBeamGF SlabDHDed Shaft El.LiftBeam1st, 2nd & 3rd Slab1st Floor CantileverDed Shaft El.LiftBeamPeragola Area BeamsMummty Area SlabOH TBeamsLift Room Area SlabBeamAdd For Slab Thick VerryMisc. |
| 13 | Providing M-35 grade concrete by using cement as per codal provision instead of M-20 grade design mix. M35 Concrete Raft & Col./Retain wall |
| 14 | Providing M-30 grade concrete by using cement as per codal provision instead of M-20 grade design mix. M30 Concrete Slab/Beam |
| 15 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. Raft & FoundationGrid-1-5 & 10-14, A-LPorch 3-side Col. FoundationsRamp retain Wall RCC Foundation Grid-5-10, E-KAddDedLift & Sump pitLift & Sump RaftCol. PedestalC-101,104,109,112, C-501,504,509,512 Size 500x500mmC-102,103,105,108,110,111,C-201,202,203,204,209,213,215,224,227,228,229,230,231,C-309,312,313,317,319,323,324,329,330,335,C-401,402,403,404,409,413,415,424,427,428,429,430,431,C-502,503,505,508,510,511, Size 500x750mmC-106,107,C-205,206,207,208,210,211,212,216,217,218,219,220,221, 222,225,226,C-331,332,333,334,C-405,406,407,408,410,411,412,416,417,418,419,420, 421,422,425,426,C-506,507 Size 500x900 mmC-310,311,314,316,320,321,322,325,326,327,328 Size 500x1200mmC-315,318 Size 500x1500 mmC-214,223,C-301,302,303,304,305,306,307,308,C-414,423 Dia=600 mmMisc |
| 16 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Columns, pillars, posts and struts etc. Col. RCCBasement to NGL 0.00 Lvl.C-101,104,109,112, C-501,504,509,512 Size 500x500mmC-102,103,105,108,110,111,C-201,202,203,204,209,213,215,224,227,228,229,230,231,C-309,312,313,317,319,323,324,329,330,335,C-401,402,403,404,409,413,415,424,427,428,429,430,431,C-502,503,505,508,510,511, Size 500x750mmC-106,107,C-205,206,207,208,210,211,212,216,217,218,219,220,221, 222,225,226,C-331,332,333,334,C-405,406,407,408,410,411,412,416,417,418,419,420, 421,422,425,426,C-506,507 Size 500x900 mmC-310,311,314,316,320,321,322,325,326,327,328 Size 500x1200mmC-315,318 Size 500x1500 mmPorch Col. Foundation to Plinth Lvl.C-214,223,C-301,302,303,304,305,306,307,308,C-414,423 Dia=600 mmCol. RCCNGL 0.00 Lvl.to Basement SlabC-101,104,109,112, C-501,504,509,512 Size 500x500mmC-102,103,105,108,110,111,C-201,202,203,204,209,213,215,224,227,228,229,230,231,C-309,312,313,317,319,323,324,329,330,335,C-401,402,403,404,409,413,415,424,427,428,429,430,431,C-502,503,505,508,510,511, Size 500x750mmC-106,107,C-205,206,207,208,210,211,212,216,217,218,219,220,221, 222,225,226,C-331,332,333,334,C-405,406,407,408,410,411,412,416,417,418,419,420, 421,422,425,426,C-506,507 Size 500x900 mmC-310,311,314,316,320,321,322,325,326,327,328 Size 500x1200mmC-315,318 Size 500x1500 mmPorch Col.C-214,223,C-301,302,303,304,305,306,307,308,C-414,423 Dia=600 mmBasement Slab to GF SlabC-101,104,109,112, C-501,504,509,512 Size 500x500mmC-102,103,105,108,110,111,C-201,202,203,204,209,213,215,224,227,228,229,230,231,C-309,312,313,317,319,323,324,329,330,335,C-401,402,403,404,409,413,415,424,427,428,429,430,431,C-502,503,505,508,510,511, Size 500x750mmC-106,107,C-205,206,207,208,210,211,212,216,217,218,219,220,221, 222,225,226,C-331,332,333,334,C-405,406,407,408,410,411,412,416,417,418,419,420, 421,422,425,426,C-506,507 Size 500x900 mmC-310,311,314,316,320,321,322,325,326,327,328 Size 500x1200mmC-315,318 Size 500x1500 mmPorch Col. C-214,223,C-301,302,303,304,305,306,307,308,C-414,423 Dia=600 mmGF Slab to 1stC-101,102,103,104,109,110,111,112,C-201,202,203,204,228,229,230,231,C-313,317,319,323,324,329,330,335,C-401,402,403,404,428,429,430,431,C-501,502,503,504,509,510,511,512 Size 500x500mmC-105,108,C-205,206,207,208,209,210,211,212,213,215,216,217, 218,219,220,221,222,224,225,226,227,C-309,312,331,332,333,334,C-405,406,407,408,409,410,411,412,413,415,416,417, 418,419,420,421,422,424,425,426,427,C-505,508 Size 500x750mmC-106,107,C-310,311,314,316,320,321,322,325,326,327,328,C-506,507 Size 500x900 mmC-315,318 Size 500x1200mmPorch Col. Foundation to Plinth Lvl.C-214,223,C-301,302,303,304,305,306,307,308,C-414,423 Dia=600 mm1st to 2nd F SlabC-101,102,103,104,109,110,111,112,C-201,202,203,204,205,208,209,212,213,215,218, 219,222,224,227,228,229,230,231,C-309,312,313,317,319,323,324,329,330,331,332,333,334,335,C-401,402,403,404,405,408,409,412,413,415,418,419, 422,424,427,428,429,430,431,C-501,502,503,504,509,510,511,512 Size 500x500mmC-105,106,107,108,C-206,207,210,211,216,217,220,221,225,226,C-310,311,320,321,322,325,326,327,328,C-406,407,410,411,416,417,420,421,425,426,C-505,506,507,508 Size 500x750mmC-314,315,316,318 Size 500x900 mm2nd F to 3rd F SlabC-101,102,103,104,109,110,111,112,C-201–213,215–231,C-309,312,313,317,319,323,324,329–335,C-401–413,415–431,C-501–504,509–512 Size 500x500mmC-105,106,107,108,C-310,311,314,316,320,321,322,325,326,327,328,C-505,506,507,508 Size 500x750mmC-315,318 Size 500x900 mmAbove Terrace C-101,102,103,104,109,110,111,112,C-201–213,215–231,C-309,312,313,317,319,323,324,329–335,C-401–413,415–431,C-501–504,509–512 Size 500x500mmC-105,106,107,108,C-310,311,314,316,320,321,322,325,326,327,328,C-505,506,507,508 Size 500x750mmC-315,318 Size 500x900 mmMummtyC-102,103,104,C-225,226,227,C-229,230,231,C-502,503,504,C-429,430,431 Size 500x500mmC-425,426,427, Size 500x750mmOH-TC-226,227,C-230,231, C-430,431 Size 500x500mmC-426,427, Size 500x750mmMisc. |
| 17 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Walls (any thickness) including attached pilasters, buttresses plinth and string course.RCC WallBasement to NGL 0.00 Lvl.Share wallSW-301,302,303,306,307,308 Size 230x3460mmSW-304,305 Size 230x3230NGL 0.00 Lvl.to Basement SlabShare wallSW-301,302,303,306,307,308 Size 230x3460mmSW-304,305 Size 230x3230Basement Slab to GF SlabShare wallSW-301,302,303,306,307,308 Size 230x3460mmSW-304,305 Size 230x3230GF Slab to 1stShare wallSW-301,302,303,306,307,308 Size 230x3460mmSW-304,305 Size 230x32301st to 2nd F SlabShare wallSW-301,302,303,306,307,308 Size 230x3460mmSW-304,305 Size 230x32302nd F to 3rd F SlabShare wallSW-301,302,303,306,307,308 Size 230x3460mmSW-304,305 Size 230x3230Above Terrace Share wallSW-301,302,303,306,307,308 Size 230x3460mmSW-304,305 Size 230x3230MummtyWall L=6.55*2+(5.23-0.23*2)*2Reatin wall Basement L=(20.465+5.03+40.785+16.03+22.655+20.985+16.27)*2 +(9.87+8.27)*2+25.26+45Ramp Inside Basement side wallDed Col. Common AreaBasement Floor BelowLift Walls Basement FloorLift Walls Sump Wall Below RaftMisc. |
| 18 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. Basement Lvl.Plinth Beam/Connecting Beam at NGLBoth Side Porch Col.Front Entry Side Porch Col.Basement Sump Pit SlabBasement SlabDed Shaft El.LiftBasement Slab FaceShaftEl.LiftBeamGF SlabDHDed Shaft El.LiftGF Slab FaceDHShaftEl.LiftBeam1st, 2nd & 3rd Slab1st Floor Cantilever Ded ShaftEl.Lift1st, 2nd & 3rd Slab Face1st Floor Cantilever ShaftEl.LiftBeamPeragola Area BeamsPeragola Area Beams BottomMummty Area SlabOH TMummty Area Slab FaceOH T BeamsLift Room Area SlabLift Room Area Slab FaceBeamAdd For Slab Thick VerryMisc. |
| 19 | Add extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan are is to be measured)Addition Height Above 3.5 Mtr |
| 20 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786). Thermo-mechanically Treated bars (Conforming of relevent IS code)RCC Steel |
| 21 | Finishing WorkProviding and laying M30 grade controlled cement concrete pavements including mixing and vibrations concrete with necessary needle vibrators and surface with screed board vibrating complete in all respect with 20/25 mm stone aggregate (crusher broken) including anti-skid textured finish to required camber/ super elevation and grade including curing etc. as per specification with cement concrete M-30 grade including cost of Steel frame work for sides of C.C. pavement consisting of M. S. channels flats and angles with required steel pegs ( some of them may left embedded in concrete/ including providing frame work)Basement Parking & Ramp VDC BasementRampDed PedastelLiftEl/ ShaftMisc. |
| 22 | Extra for vacuum processed concrete including cost of equipments labour etc.Basement Parking & Ramp VDC BasementRampDed PedastelLiftEl/Shaft |
| 23 | Cutting of construction joint/ longitudinal joint 4 to 6 mm. wide using mechanical concrete cutter including cost of diamond bit cutting wheel and filling of bitumen sealing compound in groove including cost of sealing compound. 50 mm depthBasement Parking & Ramp VDC BasementMisc. |
| 24 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:4 ( 1-Cement : 4-Sand).Foundation Step Side Entry Front EntryBack Side Entrys |
| 25 | Brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth with bricks Cement mortar 1 : 4 (1 cement : 4 coarse sand)Lift and Supt Pit wall Inside FaceFoundation Step Side Entry Front EntryBack Side EntrysDedBasement Internal WallsLift WallDedD-LiftStep |
| 26 | Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 25mm thick .Plaster Basement Retain wall External & internal FaceRam Side Lift Pit WallExternalPit FaceAdd misc. |
| 27 | Supplying and applying bituminous solution primer on roofs or on wall surface at 0.24 litre per sqm.Plaster Basement Retain wall External FaceLift Pit WallExternalPit FaceBaseAdd misc. |
| 28 | Add extra over item of brick work with class designation 100 in substitution of class designation 75 : Quantity in Cum.Below Plinth wall |
| 29 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand)Ground Floor External WallCanteen/Kitchen Portion to Front to Back L =(4.22+5.46+4.25)*2+(15.46-0.5)*2*2+4.23*2+5.555*2+1.03*2+2*2+5.03*2+4.77+1.17+4.99*2+(6.48-0.5)*2+(3.735+4.23+5.28)*2+(15.5*2+10.225-3*0.5)*2+9.82*2+9*2*2+(7.45+7.23)*2+45-0.5*4+1+5.23+1.495+4.23+3.735+5.28+5.03+4.23+6DedD-LiftDRamp GateWStep1st Floor1-A, Back side toward fronts face L=14.955*2+15.5*2*2-0.5*4*2+4.23*2+5.94*2+5.98*2-0.5*2+3.98-0.5+1.03+2+5.065+11.765-0.5+5.035+2.28+2*3.735+1.73+1.63+3.43+4.23+15.55*2*2-0.5*2*2+14.955*2-0.5*2+9+9.87+6.27+7.5*2+7.23*2+9.3+9+9.8+45-0.5*4+2*4*2+2.77*2StepDedD-LiftDW2nd & 3rd Floor 1-A, Back side toward fronts face L =14.955*2-0.5*2*2+15.5*2*2-0.5*2*2+4.23*2+6.055*2+4.23*2+45+(0.53+2+5.065)*2+6+5.265+2+3.735+1.5+15.5*2*2+14.955*2+9*2+9.87*2+17-0.5+14.27-0.5+7.23*2+5.265+3.43+16.1+3.735+4.23+2*4*2+2.77*2StepDedD-LiftDWTerrace FloorPerapet -Mummty L=(16.03+40.785+20.465+20.985-4.5+16.27+9.87+8.27+22.655+4.23+0.635*2+4.23)*2+45+25.26MummtyLift RoomDedD-MSW-FixedAdd misc. |
| 30 | Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75 Cement mortar 1 : 4 (1 cement : 4 coarse sand)Ground Floor External WallBack Side Saft Masonry L=0.315*2*2*3*2+0.27*8*3*21st-3rd Floor Corridor SideMisc. |
| 31 | Add extra providing and placing in position 2 Nos. ,6mm Ø M.S. bar at every third course of half brick masonry .Wall Work |
| 32 | Add extra over item of brick work with class designation 100 in substitution of class designation 75 : Quantity in Sqm. |
| 33 | Providing and laying Autoclaved Aerated Concrete (AAC) blocks masonary 150mm/230mm/300mm thick with Grade-I AAC blocks in superstructure above plinth level upto floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-charge. (The payment of RCC band and reinforcement shall be made for seperately).Ground Floor Internal WallsBack Side Male/Female toilet L =2.25+7.75*2+1.66*3*3+3.545*2+0.9*2+3.31+2.28+1.28Canteen/Kitchen/Pantry L=(1+2)*4.23+7.5+4.865+2.855Electrical room L=2.23+4.425H.T/Jaintory/Pantry L=(7.115*3+2.93*2+3.205*2)Electrical/Fire Shaft L=4*0.75+4.23*2+1.315+1.5H.Constable/DI/Constble rooms L=4*5.595+34.63-3*0.5Sigle W Registration/Pro Staff/Add PS PI roomElectrical/ Fire Shaft L=1+4.23+5*2+1.2+0.555M/F toilet wall L==6.615-0.5+6.885*2+1.66*2+6.25+3.555+1.54-0.5+6.135+1.885*2+1.69+3.83+1.91*2230mmM/F toilet wall L=6.25+6.48+4.23+1.25+4.48-0.5*2+1.66DedDDWDCutout WallDWDShaft DD Shaft D D 1st FloorStore/Pantry/DW area L=14.955*2+7.345*(2+1)+6.25+6.25*2Garden Sup./IP-I-II-III L=5.595*6+2*7.2+8.8DC /Tehsildar rooms L=(4.23+0.75*2+1.135*2+25.77*2+4.135*2+1.73+1.135+2.5+6.25*6+0.365+4.845+3.965)*2+1.5+1.53+5+1.53*2+3+6.135L=8.23+0.635*2+5.115+0.635*2+0.75+17-0.5+7.885+3+7.5+ 2.32+5.2+6.655+ 7.73*2230mmCutout Side wall L=6.25+6.48+4.23+1.25+4.48-0.5*2+1.66W=(0.41+0.715)/2W=(0.8+1.1)/2ToiletDedDWCutout WallDShaft DoorDDWW2nd & 3rd FloorJen/Aen Room L=14.955*2-0.5*2*2+16.155*2+5.865Male/Female T L=2.23+1.135+1.885*3+5.955+1.45+5.055+7.345+6.365+6.885+1.69+6.135+1.91*2+3.83+1.885*2Meeting/Director Rooms L=((5.595+0.635)*2+23.33+7+2.84*2+5.8)*2+6Mid Area L =8.23+0.635*4+0.75+17+10.38+7.885+1.8+2.615+16.78+7.885+3.775+2.885DTP/Xen Room L =(0.75*2+0.635*2+1.53+3.965+4.23+1.135+25.77*2+4.135*3-5+1.5+6.135*6)*2230mmToilet Side Wall L=2.23+1.135+6.25+7DedDWCutout WallDDShaft DoorDWAdd misc. |
| 34 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.. Rajasthan Black. Above 3601 Cm2 SlabsGFMale/Female T Counter Urinal PartationJaintoryDrinking water sink Counter W=0.75*2+0.45*2+0.6PantryKitchen Male/Female T Counter Pantry1st FloorJaintoryDrinking water sink Counter W=0.75*2+0.45*2+0.6PantryT Counter PantryUrinal Partation2nd & 3rd FloorT Counter PantryUrinal PartationT Counter PantryFor Design StripsMisc. |
| 35 | Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite/Kota Stone Work. Full Edge moulding |
| 36 | Providing and fixing Marble stone flooring table rubbed, 15-18 mm thick over 20mm (Av.) thick base of CM 1:4 (1 cement : 4 coarse sand) jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Makrana 'Adanga'. Above 3601 Cm2 SlabsCounter Top/ Vertical GFMale/Female T CounterUrinal PartationJaintoryDrinking water sink Counter W=0.75*2+0.45*2+0.6PantryKitchen Male/Female T Counter Pantry1st FloorJaintoryDrinking water sink Counter W=0.75*2+0.45*2+0.6PantryT Counter PantryUrinal Partation2nd & 3rd FloorT Counter PantryUrinal PartationT CounterPantryGFMale/Female T Counter JaintoryDrinking water sink Counter W=0.75*2+0.45*2+0.6Pantry Kitchen Male/Female T Counter Pantry1st FloorJaintoryDrinking water sink Counter W=0.75*2+0.45*2+0.6PantryT Counter Pantry2nd & 3rd FloorT Counter PantryT Counter Pantry |
| 37 | Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges : Kota stone minimum 30mm thick.GF1stAdd misc. |
| 38 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick.Masonry Wall Internal wallsCC Col.SWBeam Portion |
| 39 | 6 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand)Ceiling Basement & Terrace PortionDed False ceiling area |
| 40 | Providing and Applying ACRYLIC emulsion polymer waterproofing chemical coating, on over roof on over roof slabs/terrace/balconies/parapet wall etc.with following method/specification:Paint the surface with regular paint brush so as to obtain approximately 0.3mm thickness coating. apply the 2nd coat next day at right angles to the 1st coat so that total thickness of the coating should be approximately 0.6mm coverage by using above formulation will be 40 ft2/ litre of chemical. painted surface does not require any external water curing since chemical will hold sufficient water for curing.After the primer coat Apply 2 coats of modified acrylic emulsion polymer water proofing compound having solar heat reduction properties coating @ 0.330 KG/SQM on the surface of the interval of 3-4 hours. Undulation on the surface is repair before the waterproofing work.Terrace & open SlabWall AbovePillersCentiliver SlabsAdd for |
| 41 | Grading roof for water proofing treatment with water proffing compound .Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Terrace & open SlabCentiliver Slabs Ded |
| 42 | P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. size 600 mm X 600 mmTerrace & open SlabWall AboveCentiliver SlabsDedMisc. |
| 43 | Precast terrazzo tiles of approved make 20mm thick with marble chips of size upto 6mm in skirting & risers, treads of steps and dados 12mm thick cement plaster 1:3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of :. Light shade using white cement.Terrace & open Slab |
| 44 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : Terrace & open Slab |
| 45 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : Ist course of applying cement slurry @ 4.4 Kg/sum mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.IInd course of 20mm cement plaster 1:3 (1 cement: 3 coarsesand) mixed with water. proofing compound in recommendedproportion including rounding off junction of vertical andhorizontal surface.IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg per sqm. of area.IVth course of 400 micron thick PVC sheet .(Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.)Lift Pit Floor/WallSumpWallsToilets GFJaintoryDW areaPantryM/FT1stJaintoryDW areaPantryM/FTPantry Attache T2ndM/F TPantry Attache TAttache T3rdM/F TPantry Attache TAttache TWallGFJaintoryDW areaPantryM/F T1stJaintoryDW areaPantryM/F TPantryAttache T2ndM/F TPantryAttache TAttache T3rdM/F TPantry Attache TAttache T |
| 46 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades ceramic glazed vitrified tiles with water absortion less than or equal to 0.08% confirming to IS:13753 & IS : 15622 on walls, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). Size 600mm x 1200mmWall Tile |
| 47 | Providing and fixing 1st quality MAT & GLOSSY finished ceramic tile confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). Size 600mm x 600mmFloorCanteen AreaMisc. |
| 48 | Providing and fixing 18–20 mm thick Kandla Autumn Brown/Grey natural stone granite finish cladding/flooring/paving of approved quality, colour and texture, machine cut and dressed to required size and shape as per approved design, drawings and directions of the Engineer-in-Charge, fixed with cement mortar (1:4), white cement slurry mixed with approved pigment to match the stone shade, including necessary backing mortar, cutting, edge dressing, moulding, grooves, joints, pointing, curing, polishing/finishing, transportation, loading, unloading, lifting, scaffolding, all tools and plants, labour, materials, hardware and all incidental works complete in all respects as directed by the Engineer-in-Charge.Flooring_Khandala Brown /Grey/Black shadeWall Dedo_Khandala Brown /Grey/Black shadeStepMisc. |
| 49 | Providing, Dressing, Carving and Fixing Kandka Brown Sandstone Door Frame with RebateProviding and fixing approved quality Kandka Brown Sandstone door frame of required section and profile, having single side or double side rebate as per approved architectural drawings and site requirements, machine cut from selected stone blocks and finely dressed on all exposed faces, edges and arrises.The work shall include cutting, dressing, moulding, rebating, grooving, edge finishing, polishing/rubbing of exposed surfaces where required, making holes, notches and recesses for fixing of shutters, hardware and accessories, providing necessary dowels, SS pins, cramps, anchors and mechanical fixing arrangements complete.The stone frame shall be fixed in position with approved non-shrink grout, cement mortar, stainless steel dowels, cramps, anchor fasteners and fixing accessories including packing, alignment, leveling, plumbing and joint treatment complete.The item shall include all leads and lifts, loading, unloading, transportation, handling, scaffolding, staging, labour, tools & plants, safety measures, wastage, curing and all incidental works required for proper completion of work as per approved DPR drawings, specifications and directions of Engineer-in-Charge.The frame shall be provided with single rebate or double rebate as shown in drawings. No extra payment shall be made for cutting, dressing, grooves, rebates, holes, lifting arrangements, dowels, cramps, anchors, fixing accessories and finishing operations. Complete in all respects. Size upto 125mmx75mmDoor FrameGround Floor D1st FloorD2nd & 3rd Floor DGround FloorDDDDD1st FloorDD2nd & 3rd FloorDD |
| 50 | Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side.Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-E weather seal gaskets alongwith 6mm thick ISI make plain float glass. Mesh shutter shall be made of 39w x 69h mm Extruded 3 box multi-chamber UPVC Window profile section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5 mm thick GI section duly mitered cut & thermal welded at all corners and fitted with nylon/polymer mesh and rollers/pully.WindowSite Use |
| 51 | Providing & Laying Tactile tile (for vision impaired persons is standard of size 300x300x20mm and confirming to IS 1231 of 1980 (Re affirmed in 2006) in all colours & sheds further product should confirm ASTM 303 for shad resistance and DIN51099 for colour fastness etc. laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 course sand) in all shapes & patterns including grouting the joint which white cement mixer) will matching pigments etc complete is per direction of Engineer-in-charges. Grade M 30 |
| 52 | Add extra for Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477 , using 5kg. adhesive per sqm of tile area, in average 3mm thickness instead of cement mortar. |
| 53 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide Site Use Grill MS Work Jaali FrameStair case and rampRampInside Cooridors |
| 54 | Extra if square,rectangular hollow tubelar sections are used or grill made by flats only MS Work |
| 55 | Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of T-iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension).Ramp |
| 56 | Providing and fixing of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80x25 mmx 1.25 mm thick with 1.00 mm MS sheet to spot welded including holdfasts of 15x3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts and twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate and spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer In ChargeStaircase Mummty |
| 57 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work Steel Work |
| 58 | Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete. |
| 59 | For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Polyester Powder coating aluminum ( minimum thickness of powder coating 50 micron) Ground Floor W1st Floor W2nd & 3rd Floor WTerrace FloorW-FixedGround Floor DWDWShaft DShaft D1st FloorDWShaft DoorDWW2nd & 3rd FloorDWShaft DoorDWFor Reception & Entry gate use/Peragolla |
| 60 | Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.) With float glass panes of 8 mm thickness Ground Floor W1st Floor W2nd & 3rd Floor WTerrace FloorW-FixedGround Floor DWDWShaft DShaft D1st FloorDWShaft DoorDWW2nd & 3rd FloorDWShaft DoorDWFor Reception & Entry gate use/Peragolla |
| 61 | 10 mm thick glass |
| 62 | Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Grade 304For Sky Light work Frame work |
| 63 | Extra for providing toughened glass panes instead of ordinary float glass panes in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). For 10mmEntry gates |
| 64 | Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. Door Closser |
| 65 | Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.) With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm)For Reception & other use |
| 66 | Providing and fixing Structural glazing work with toughened glass of 6mm thick and reflective colour as approved in dark shade like Blue/Dark Blue etc. with frame work of curtain section 65x60mm (Weight 1.64 kg/m min.) made of aluminium with chrome plating. Internal frame work will also be of curtain section 65x60mm of chrome plated aluminium section with20x20mm aluminium tube section and structural spacer made of rubber. The aluminium frame work size as per instruction of Engineer-in-charge and including openable panels with all necesary sections and fitting.The work include silicon structural adhesive for complete gripping of glass with framing members and silicon weather seal sealant to prevent moisture/water through joints. Glass will be fixed in plumb and with uniform spacing of 10-12mm wide duly filled with silicon weather seal sealant. The work includes all labour,scaffolding , structural aluminium work, toughened glasses,silicon weather seal sealant, silicon structural adhesive structural spacer, all accessories like handles, peg stays, M-15 grade cement concrete for fixing holdfast .(Face area of glass shall be measured)For Enty Exit |
| 67 | Providing and fixing ornamental stone jali of approved quality Dholpur White Sand Stone, 50 mm thick, machine cut and hand carved in approved decorative patterns as per DPR, approved drawings and directions of the Engineer-in-Charge, including all cutting, carving, dressing, edge finishing, lifting, hoisting and fixing on walls, frames, columns, screens, parapets or at any required location with approved epoxy adhesive, SS 304 cramps/dowels, anchor fasteners, grouting and pointing complete. The item shall include all materials, labour, scaffolding, staging, tools and plants, hardware, fixtures, transportation, loading, unloading, safety arrangements, cleaning and all incidental works required for complete installation in all respects as directed by the Engineer-in-Charge.GFFront Both of Entry PortionBack Both Side 1st to 3rd floorAdd misc. |
| 68 | Providing & fixing door, window, chowkhats and other frames, including antitermite treatment, M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade :Nigeria teak wood Grade - I.Staircase Railing Handrail toopAdd misc. |
| 69 | Providing and fixing 300C Aluminium Panel with perforation of 2mm diameter and 5mm centre to centre to give 15% open area with Non woven textile False Ceiling system of approved colour consisting of Panel 300 mm wide X 30 mm deep X 0.7 mm thick with bevelled edges having panel length upto 6 mtrs, Coil Coated on a Continuous Paint Line, Double baked and roll formed for higher strength and good roll forming characteristics. The panel ends will be raised upto 29mm. Panel shall be clipped to a baked enamelled aluminium panel carrier of 41.5mm wide x 62mm deep x 0.95 mm thick in standard length of 5 mtrs. made of double baked stove enamelled aluminium magnesium alloy AA3005 black with cut outs to hold the panels. The Carrier shall be suspended by means of G.I. threaded rod of 6-mm diameter directly fixed to the Carrier. The Carrier tabs to be bent down to secure the panels at all Panel Carrier intersections. The panels will be installed in a module of 300MM. (Tensile strength of suspension-344/413 mpa and fastner strength-110kg) All Ceiling Panels shall adhere to GreenPro Certifications.ACP work Basement Col Edge |
| 70 | Providing and fixing 150 mm wide sheet covering over expansion joints with iron screws as per design to match the colour / shade of wall treatment. Aluminum fluted strips 2 mm thickExpansion Joint work |
| 71 | Supplying and providing of two components poly sulphide sealant containing solid contents, confirming to standard specification and approved compatible primer, for priming vertical faces prior to application of poly sulphide sealant including all labour charges for sealing of expansion joints after drill mixing of two components sealing compound. Cleaning and preparation of expansion joint using wire brush sand papering with emery paper and filing with suitable mechanical means. The work includes racking and cleaning of joints, sticking, debonding tape on bottom of joint, applying primer on edges, using masking tape on edges, providing of sealant and removal of masking tape immediately after providing sealant in joint. To vertical joint between RCC columns, bricks & stone masonry in size 40 mm width and 12 mm depth, including providing back up material (Thermocol foam) if required. Expansion Joint work |
| 72 | To joints in flooring, as per drawing with first layer of poly sulphide sealant in size 20 mm width and 10 mm depth over PE Foam and then providing polyethylene foam back up rod 25 mm dia size and finally providing another layer of poly sulphide sealant in size 20 mm width and 10 mm depth over P.E. back up rod as per application procedure and direction of Engineer-in-charge.Expansion Joint work |
| 73 | Providing and fixing in position bitumen impregnated fiberboard confirming to IS: 1838 in expansion joints including the cost of primer sealing compound. 12 mm. thick Expansion Joint work |
| 74 | Providing, hoisting and fixing up to floor five level precast reinforced concrete work in Nominal M20 grade mix including cost of required centering, shuttering, finishing, smooth with 6 mm thick cement plaster 1:3 (1 cement: 3 fine sand) on exposed surface complete excluding cost of reinforcement String courses, copings, bed plates, anchor blocks, plain window sills etcFor window sill and lintel |
| 75 | Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric membrane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 100 grouted with cement mortar 1:3 (1cement:3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat which shall be paid for separately.Below Raft |
| 76 | External Stone CladdingProviding and Fixing Dholpur White Stone Veneer Cladding on Plain Wall SurfaceProviding and fixing Dholpur White Sandstone Veneer Cladding of 40 mm to 50 mm thickness on plain wall surfaces, conforming to approved drawings, specifications and architectural details, using approved quality Dholpur White Stone, machine cut and finely dressed on exposed surfaces and edges. The stone shall be fixed with SS-304 cramps, dowels, pins, brackets, anchor fasteners and stainless-steel anchoring system complete as required. The work shall include cutting, shaping, dressing, drilling, grooving, edge finishing, making openings and holes, providing and applying polymer modified mortar/grout, joint treatment, pointing, approved sealant filling, alignment, leveling, plumbing, curing, scaffolding, staging, hoisting, loading, unloading, transportation, labour, tools & plants, safety measures and all incidental works necessary for proper completion of the work.The rate shall include all materials, labour, equipment, wastage, handling, fixing arrangements and all operations required for satisfactory completion of the work up to 5th floor level, complete in all respects as per approved DPR drawings, technical specifications and directions of Engineer-in-Charge.External wallWindow JambGround Floor W1st Floor W2nd & 3rd FloorWWTerrace FloorW-FixedGround Floor DWDW Shaft DShaft D 1st Floor DWShaft DoorDWW2nd & 3rd FloorDWDW Lift 3 side Basement internal wall |
| 77 | Providing, Carving, Dressing and Fixing Decorative Architectural Elements in Dholpur White StoneProviding and fixing approved quality Dholpur White Sandstone decorative architectural elements of 100 mm to 300 mm thickness comprising traditional motifs, floral motifs, animal figures, human figures, heritage patterns, girdana, dasa, mouldings, cornices, bands, borders, jharokha elements, pilasters, decorative panels, brackets, chhajja fascia treatment and other ornamental architectural features as per approved drawings, elevations and architectural details.The work shall include procurement of stone blocks/slabs, machine cutting, hand dressing, manual carving, CNC carving wherever required, shaping, profiling, chamfering, moulding, edge finishing, engraving, relief carving, preparation of templates, sample approval, marking, cutting, grooving, drilling, rebates, notches, polishing of exposed surfaces where required, transportation, loading, unloading, stacking, handling and protection of finished stone work.The decorative stone members shall be fixed on RCC, masonry or structural surfaces using approved stainless steel (SS-304) cramps, dowels, anchor fasteners, pins, brackets and mechanical anchoring system complete with polymer modified mortar, non-shrink grout, sealants, joint filling, alignment, leveling and plumbing complete.The rate shall include cost of all materials, labour, skilled stone carvers, artisans, scaffolding, staging, lifting, hoisting, tools and plants, templates, machinery, consumables, wastage, safety arrangements, testing, curing, protection of finished surfaces and all incidental works required for satisfactory completion of work up to 5th floor level as per approved drawings and directions of Engineer-in-Charge.Nothing extra shall be paid for intricate carving, edge finishing, templates, grooves, holes, lifting, scaffolding, transportation, wastage, fixing accessories and all leads and lifts.External wall Face designer AreaDesign |
| 78 | Plumbing Work Part -1Providing & Fixing Premium Quality white glazed vitreous china Sanitary Wares (IS:2556 Mark) of approved make as per direction of Engineer-in-charge including cutting and making good the wall and floor..Wall Mounting European type W.C. |
| 79 | Health focet (Premium heavy Quality) as approved by Engineer-in-Charge |
| 80 | P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. Flat Back (large) or half stall size 610x400x80mm. |
| 81 | P & F W.V.C. Urinal Partition Plate of approved standard make of size 630x315mm including making good the wall. |
| 82 | P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :. Size 630 mm x 500 mm dia for counter top |
| 83 | P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor :Mosaic fine polished kitchen sink size 450 x 450 x 200mm. |
| 84 | Providing & Fixing Premium quality Bottle trap internal portion 32mm, size 250mm long wall connection pipe & wall flange as per approved by Engineer in Charge. |
| 85 | P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. . Other sizes |
| 86 | P & F Liquid Soap Container with brackets complete of approved make:C.P. brass |
| 87 | P & F Toilet Paper Holder with rod of approved quality/make:C.P. brass heavy & Superior quality. |
| 88 | P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. |
| 89 | Providing & fixing C.P.flange for 15mm dia taps. |
| 90 | P & F C.P. brass Urinal Spreader for Large Urinal of heavy duty of approved make as per direction of Enginner-in-Charge |
| 91 | Providing & Fixing Concealed cistern with Floor mounting frame and flush plate of superior quality and approved sample by Engineer-in-charge. |
| 92 | P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:C.P. Brass Long body, 15mm nominal bore weight not less than 690 gm |
| 93 | P & F Stop Cock (IS :8931 Mark), superior quality & of approved make:C.P. Brass 1350gm. 25 mm nominal bore. |
| 94 | P & F Sink Cocks of superior quality & approved made :C.P. Sink cock swinging spout 15mm. |
| 95 | P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked) |
| 96 | P & F 15 mm. Dia Connection Pipe of approved quality/make :(-do-) 600mm. |
| 97 | P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :(-do-) 25mm nominal bore. |
| 98 | (-do-) 32mm nominal bore. |
| 99 | (-do-) 40mm nominal bore. |
| 100 | (-do-) 50mm nominal bore. |
| 101 | (-do-) 65mm nominal bore. |
| 102 | P & F Gun-metal Non-return Valve or Check Valve (IS : 778 Make) of approved make, superior quality:40mm nominal bore.Horizontal |
| 103 | Vertical |
| 104 | 50mm nominal bore.Horizontal |
| 105 | Vertical |
| 106 | P & F foot valve of superior quality and approved make with fittings :Brass 25 mm. |
| 107 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall)20mm nominal size |
| 108 | 25 mm nominal size |
| 109 | 32mm nominal size |
| 110 | 40 mm nominal size |
| 111 | 50 mm nominal size |
| 112 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)20mm nominal size |
| 113 | 25 mm nominal size |
| 114 | 32mm nominal size |
| 115 | Providing & fixing C.I. Saddle pieces 100mm dia with nut & bolt & washer & Rubber Gasket complete as per direction of engineer in charge |
| 116 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make75 mm dia |
| 117 | 110 mm dia |
| 118 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /makeCoupler75mm dia |
| 119 | 110mm dia |
| 120 | Repair Coupler75mm dia |
| 121 | 110mm dia |
| 122 | Single Push Fit Coupler75mm dia |
| 123 | 110mm dia |
| 124 | Bend 87.5 Dg.75mm dia |
| 125 | 110mm dia |
| 126 | Bend 45 Dg.75mm dia |
| 127 | 110mm dia |
| 128 | Door Bend 87.5 Dg.75mm dia |
| 129 | 110mm dia |
| 130 | Single 'Y'75mm dia |
| 131 | 110mm dia |
| 132 | Single 'Y' with Door75mm dia |
| 133 | 110mm dia |
| 134 | Double 'Y'75mm dia |
| 135 | 110mm dia |
| 136 | Double 'Y' with Door75mm dia |
| 137 | 110mm dia |
| 138 | Socket Plug75mm dia |
| 139 | 110mm dia |
| 140 | Pipe Clip75mm dia |
| 141 | 110mm dia |
| 142 | Double tee with Door75mm dia |
| 143 | 110mm dia |
| 144 | W.C. Connector110mm dia |
| 145 | W.C. Connector (Bend) with ring110mm dia |
| 146 | Single Tee75mm dia |
| 147 | 110mm dia |
| 148 | Single Tee with Door75mm dia |
| 149 | 110mm dia |
| 150 | Double Tee (4 Ways)75mm dia |
| 151 | 110mm dia |
| 152 | Multi floor trap110mm dia |
| 153 | Offset110mm dia |
| 154 | Extra Square Jali110mm dia |
| 155 | Extra Round Jali110mm dia |
| 156 | Extra 4 SWR Ring75mm dia |
| 157 | 110mm dia |
| 158 | Gully Trap 110mm dia |
| 159 | Nahni Trap with Jali 4”110mm dia |
| 160 | Nahni Trap without Jali 4”110mm dia |
| 161 | Nahni Trap with Jali 3”75 mm dia |
| 162 | Nahni Trap without Jali 3”75 mm dia |
| 163 | Vent Cowel 75 mm |
| 164 | Vent Cowel 110mm dia |
| 165 | Providing, Laying & Jointing R.C.C. class NP-2 Non-Pressure pipes (IS : 458mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexiblerubber rings joint including testing of joints etc. complete :150 mm dia Internal |
| 166 | 200 mm dia Internal |
| 167 | 250 mm dia Internal |
| 168 | 300mm dia Internal |
| 169 | Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring,ferro Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M |
| 170 | Add extra over item 3.19.1 for every additional 0.10m depth above 0.5 m depth. |
| 171 | Construction of Man hole, in all types of soil, inner size 1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C. flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design :Depth up to 1.5 M |
| 172 | Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floatingneat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtrInside size 450 x 450mm depth upto 0.5 M Cement cover with frame |
| 173 | Inside size 600 x 450mm depth upto 0.5 M to 1.0 M Cement cover with frame. |
| 174 | P & F M.S. Foot Rests in with C.M.,1:3, standard design in 20mm square M.S. bar 50 mm embedded in wall & 10 cms. projected out complete |
| 175 | Supplying and fixing Ferro- cement cover with C.I. frame for chambers & man holes of size.Rectangular shape 600 x 450 mm, to withstand 3 MT center point load & minimum unfractured load of 1 MT. (Light duty) |
| 176 | Supplying & Fixing R.C.C. Manholes covers with frame of approved make (Light duty).Size 450 X 450mm |
| 177 | P & F Square-mouth gully trap `A` grade (IS 651-1992 :marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as perapproved design & typeTrap size 150 X 100mm, ferrow cement cover with frame, Internal Chamber size 300 X 300mm |
| 178 | Trap size 225 X 150 mm, ferrow cement cover with frame Internal Chamber size 450 X 450mm. |
| 179 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. |
| 180 | Fixing water meter (IS: 779 mark) and stop cock in G.I. pipe line including making chamber of approved size excluding cost of water meter & stop cock. |
| 181 | Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete |
| 182 | Plumbing Part 2Providing & Fixing of IP51 direct or CT operated, 1x240 / 3x240 volts , 50 Hz static watt-hour meter (kwh) as per PWD specification for electrical Works, ISI marked (IS :13010-2002 ) having resolution 0.1 / 0.01 kwh , accuracy class 1 as per IS:13779, LED indicators for tamper operation ( Reverse &/or earth connection) , pulsating LED indicator for meterology , LCD Display, cover plate for body and terminal sealing , push button for all standard parameters, including making connection ,testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 3ph, 4W Trivector Meter,240 V(L-N) 5A |
| 183 | Supplying and Fixing of PN 16 Cast Iron Dual Plate Wafer Type Check Valve / Non return valve with SS / Bronze flap complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 80 mm dia |
| 184 | Supplying, Installation, Testing & Commissioning of submersible type dewatering pump of stainless steel casing and Cast iron impellor of discharge and head given below complete with all accessories suitable for operation on 230 V, single phase/415 V /3 phase, 50 Hz. AC supply complete with starter for automatic operation including water level sensing device / float switch inter connection with submersible cable etc. as required. 180 LPM with 10 mtr head |
| 185 | SITC of Radial / mixed flow water and anti-corrosive liquid filled submersible motor pump sets suitable for 100/150mm dia borewell. The size of adopter fixed on top of the motor should exceed the top of coupler , for safegaurd the coupler. The job includes labour part of lowering of riser pipe G.I./ H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to Starter. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect. 100 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively. 5.0 HP, 1-Ø, (56 - 236)Mtr, (90 - 25) LPM Copper wound |
| 186 | SITC of Drain Sewage pump Non-clog fully floodable submersible pump suitable to handle raw sewage suitable for up to 40 mm solid with Cast iron CED coated Impellor, CI body & housing, SS shaft, Mechanical seal etc. as required. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. Appropriate type test certificate / OEM test report shall be submitted.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 3.0 HP, 3-Ø, (8 - 20)Mtr, (590 - 220) LPM |
| 187 | SITC of Pressure boosting pump with 24 Ltr. MS Tank, pressure switch, pressure gauge, and all standard fittings fully automatic ON / OFF system, 2900 RPM with stainless steel casing, & impellor suitable for following capacity complete in all respect. Appropriate type test certificate / OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 1.0 HP ( 25 - 15 ) Mtr, (30 - 48 ) LPM |
| 188 | SITC of MNRE approved & confirming to IS:12933 P-1,2,3 & 5 Flat Plate Collector type solar hot water system having collector with Zincalum sheet outer body , Glass - line / Titanium Enamel coated Inner tank with Metal rust proof PUF insulated Body including electrical back up, Thermostat, Powder coated / Hot dipped galvanized MS stand for Collector & Tank etc. as required. of following capacity complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 500 litre/ day |
| 189 | Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap action adjustable thermostat , Dual indicating lamps Injected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloy connection, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 50 Ltr. |
| 190 | Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler with hermetically sealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick) and tank (0.5 mm thick) , stainless steel water tray,minimum two nos Brass Chrome plated faucets and suitable drainage system complete in all respect with required height MS fabricated and Painted Angle iron frame ( Cost of frame to be paid Extra )complete in all respect of the following capacity. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs |
| 191 | SITC of Contactor OEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Cordinatiom Chart and made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps etc. suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . For Three phase Submersible / Mono block pump 7.5 HP to 10.0 HP ( Star / Delta starter ) |
| 192 | Tubewell Construction of tube-well from ground levels and upto 100 Meter depth and above to accommodate housing and assembly pipe of following sizes in all types of alluvium strata by percussion/ rotary drilling method and with gravel as per IS:4097-1967 and packing as per IS:2800 (Part I -& II) 1979 as amended upto date (the work includes the cost of gravel & its primary packing and packing during development, lowering of housing & strainer assembly pipes, with supply and wrapping of coir-rope, wherever necessary, for arresting fine sand particles. The work will not include cost of housing pipe and strainer pipe assembly and development work, but work would be completed after obtaining sand free water).250mm –do-.Tube well |
| 193 | Supply of ERW M.S. black casing pipe ISI marked (IS:4270/1992) of grade Fe410 of following sizes at site of work.200 mm Nominal bore of pipeTube well |
| 194 | Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985.200mm-do-.Tube well |
| 195 | S & F tube well cover of M.S.sheet (6mm thick) with nuts and bolts complete for casing size:250mm diaTube well |
| 196 | S & F M.S. clamp, set of 50 ×6mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set.Tube well |
| 197 | Installation of submersible motor pump set in Tube-well/open well complete ( labour charges only) including transportation of tripod, chain pulley block & any other material required for lowering purpose.Tube well |
| 198 | Providing & Fixing of HDPE pipe Confirming to IS:4984:2021 for water supply suitable for submersible & jet pump with required fittings ie socket, elbows, tee etc. complete in all respect. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .for vertical installation90 mm OD 10 kg / cm2Tube well |
| 199 | Providing & Fixing of HDPE pipe Confirming to IS:4984:2021 for water supply suitable for submersible & jet pump with required fittings ie socket, elbows, tee etc. complete in all respect. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . for Horizontal installation75 mm OD 4 kg/ cm2Tube well |
| 200 | Supply and Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , Children free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required.6.0 Sq.mm 3 core flat / RoundTube well |
| 201 | SITC of Radial / mixed flow water and anti-corrosive liquid filled submersible motor pump sets suitable for 100/150mm dia borewell. The size of adopter fixed on top of the motor should exceed the top of coupler , for safegaurd the coupler. The job includes labour part of lowering of riser pipe G.I./ H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to Starter. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect.150 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively.7.5 HP, 3-Ø, (85-165)Mtr, (300-100) LPMTube well |
| 202 | SITC of IP 54 OEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Coordination Chart and made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection(for three phase pumps), Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps, 2P/4P MCB etc. suitable for following rating motors complete in all respect. For Three phase Submersible / Mono block pump12.5 HP to 15.0 HP ( Star / Delta starter )Tube well |
| 203 | UG, STP and Harvesting Tank Civil WorksAdd extra for providing richer mixes respectively at all floor levels Providing M-25 grade concrete by using cement as per codal provision instead of M-20 grade design mix. RCC Work |
| 204 | Providing and fixing 1st quality standard Marble printed/ Granite Shade or Light/dark shad glazed tiles confirming to IS : 13753 & IS :15622 of size 300mm x 600mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).Wall & FloorMisc |
| 205 | Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Serrated with central bulb (225 mm wide, 8-11 mm wide) |
| 206 | P & F M.S. Foot Rests in with C.M.,1:3, standard design in 20mm square M.S. bar 50 mm embedded in wall & 10 cms. projected out complete. |
| 207 | Supplying and fixing C.I. Cover with frame, C.I. gratings for chambers & man holes. |
| 208 | Parking & RoadsEarth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods watering, rolling each layer with 1/2 tonne roller, or stone or steel rammers and rolling every 3rd and top- most layer with power roller of minimum 8-10 tonne capacity and dressing up in embankment for roads, flood banks marginal banks and guide banks or filling up ground depressions, lead up to 50 Mtr. and lift up to 1.5 Mtr.: All kinds of soilRoad and ParkingConcrete PavementBack SideBuiling Both sides in back insidesFrontEntry/Exit RampPath ways InterlockingFront SideBack Side Garden & buildingOuter Pathway |
| 209 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils Landscape Area Edge Kerb Stone |
| 210 | Granular Sub-Base with Close Graded Material (Table:- 400-1Plant Mix MethodProviding laying spreadingand compacting specifiedgraded sand, gravel (crushed stone) asper Table 400-1,400-2 or any other course material as per design mix,as per CBR in sub base course including premixing thematerial atOMC inwetmixplant, carriageofmixed material spreading in uniform layers with motor grader F.E loader on a prepared base and compacting with vibratory roller to achieve desired density (as per I.S.2720) including all material, labor, machinery, lighting guarding, barricading and maintenance of diversion complete.[MoRTH specification : Clause 401]. By mechanical means.For Grading-I MaterialRoad and ParkingConcrete PavementBack SideBuiling Both sides in back insidesFrontEntry/Exit RampPath ways InterlockingFront SideBack Side Garden & buildingOuter Pathway |
| 211 | Dry Lean Cement Concrete Sub- baseConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.Road and ParkingRoad and ParkingConcrete PavementBack SideBuiling Both sides in back insidesFrontEntry/Exit RampPath ways InterlockingFront SideBack Side Garden & buildingOuter PathwayMisc |
| 212 | Cement Concrete PavementConstruction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 602.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using water finishing to lines and grade as per drawing and MoRTH Specification Clause 602 including vaccum dewatering process with all required equipmentsRoad and ParkingConcrete PavementBack SideBuiling Both sides in back insidesFrontEntry/Exit RampMisc |
| 213 | Construction of Embankment with Material Obtained from Borrow PitsConstruction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300-1 and 300-2 with a lead upto 50 m as per MoRTH Specification Clause 305.3Road & Paking Leveling Bad Work From available sand Basement |
| 214 | M-50 100mm thick to be used in heavy-traffic ( Heavy traffic is defined as a daily traffic of 450-1500 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 2.0 to 5.0 MSA for a design life of 20 years.) like Bus terminals, industrial complexes, mandi houses roads on expansive soils, factory floor , service station, industrial pavements.etc. Category A Denated units to key into each other on four faces zigzag shape as per IRC SP 63:2004Interlocking Work Path ways InterlockingOuter PathwayMisc |
| 215 | Providing and laying of paver block as per IS 15658 : 2006 (Indian standard for precast concrete block for paving- specification) and IRC : SP:63-2004 (guidelines for the use of interlocking concrete block pavement) M-30, 60 mm thick to be used in non traffic areas like building premises, monument premises, land scapes, public gardens/ park, domestic drives, paths and patios, Embankment slopes, sand stabilization Area etc.( As per table 1 of IS 15658:2006. Category A Denated units to key into each other on four faces zigzag shape as per IRC SP 63:2004Interlocking Work Front SideBack Side Garden & buildingMisc |
| 216 | Add extra over rates of item No. 11.38, A to C if colored paver blocks are usedsInterlocking Work |
| 217 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand).Road and ParkingLandscape Area Edge Kerb Stone |
| 218 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge).Road and ParkingLandscape Area Edge Kerb StoneMisc |
| 219 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: New work (Two or more coats applied @ 3.84 kg/10 sqm). Kerb Below and Kerb Stone |
| 220 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).Planters |
| 221 | Marking Centre Line and stop lines etc. on road as per IRC pattern with thermoplastic paint of approved quality and make without glass beads laid on the road surface at temperature 160\\" C with a special applicator machine complete with a special applicator machine complete with labour material and traffic diversion arrangements. Road Work |
| 222 | Raised Payment Marker (Cats Eye) : Supplying and Fixing of Molded Shank Raised Pavement Markers made of ABS Moulded body and Polycarbonate Reflective panel swith Micro Prismatic Lens capable of providing total internal reflection of the light enter ing the lens face and shall support a load of 35000 Kilogram tested in accordance to ASIMD 4280 & ASTMD 788. The Height of Road Studis 20mm, Width 100mm, Length 100mm and minimum reflective are a of 13 sqcm one ach side.The Strength of detachment of the integrated cylender shank not less than 14+/-2mm (Thickness) and height not less than 30+2 mm from the body. Fixing will beby drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesiveRoad Work |
| 223 | Providing and fixing PVC Bump Speed Breakers size 350 mm x 250 mm x 50 mm fitted with key hooks complete with labour material and traffic diversion arrangements. Road Work |
| 224 | Providing and fixing Iron Automatic Boom Barriers With Rf Id, For Parking in all respect as per EI.Site Entry /Exit |
| 225 | Boudary Wall Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix Boundary Wall Top Beam |
| 226 | roviding and Fixing Dholpur White Stone Veneer Cladding on Plain Wall SurfaceProviding and fixing Dholpur White Sandstone Veneer Cladding of 40 mm to 50 mm thickness on plain wall surfaces, conforming to approved drawings, specifications and architectural details, using approved quality Dholpur White Stone, machine cut and finely dressed on exposed surfaces and edges. The stone shall be fixed with SS-304 cramps, dowels, pins, brackets, anchor fasteners and stainless-steel anchoring system complete as required. The work shall include cutting, shaping, dressing, drilling, grooving, edge finishing, making openings and holes, providing and applying polymer modified mortar/grout, joint treatment, pointing, approved sealant filling, alignment, leveling, plumbing, curing, scaffolding, staging, hoisting, loading, unloading, transportation, labour, tools & plants, safety measures and all incidental works necessary for proper completion of the work.The rate shall include all materials, labour, equipment, wastage, handling, fixing arrangements and all operations required for satisfactory completion of the work up to 5th floor level, complete in all respects as per approved DPR drawings, technical specifications and directions of Engineer-in-Charge.Boundaryy wallOn Brick AreaWall in 230mm 350mm thickCutoutPB & BeamFront Entry to Surrounding L=1*2*2+4.6*4+31.645*2+20.605+14.14*2+4.115*2*2+1.095*4+65.395*2+5.24*2+1.585*2+98.4+6*5Top BottomRailing WallMisc |
| 227 | Providing, Carving, Dressing and Fixing Decorative Architectural Elements in Dholpur White StoneProviding and fixing approved quality Dholpur White Sandstone decorative architectural elements of 100 mm to 300 mm thickness comprising traditional motifs, floral motifs, animal figures, human figures, heritage patterns, girdana, dasa, mouldings, cornices, bands, borders, jharokha elements, pilasters, decorative panels, brackets, chhajja fascia treatment and other ornamental architectural features as per approved drawings, elevations and architectural details.The work shall include procurement of stone blocks/slabs, machine cutting, hand dressing, manual carving, CNC carving wherever required, shaping, profiling, chamfering, moulding, edge finishing, engraving, relief carving, preparation of templates, sample approval, marking, cutting, grooving, drilling, rebates, notches, polishing of exposed surfaces where required, transportation, loading, unloading, stacking, handling and protection of finished stone work.The decorative stone members shall be fixed on RCC, masonry or structural surfaces using approved stainless steel (SS-304) cramps, dowels, anchor fasteners, pins, brackets and mechanical anchoring system complete with polymer modified mortar, non-shrink grout, sealants, joint filling, alignment, leveling and plumbing complete.The rate shall include cost of all materials, labour, skilled stone carvers, artisans, scaffolding, staging, lifting, hoisting, tools and plants, templates, machinery, consumables, wastage, safety arrangements, testing, curing, protection of finished surfaces and all incidental works required for satisfactory completion of work up to 5th floor level as per approved drawings and directions of Engineer-in-Charge.Nothing extra shall be paid for intricate carving, edge finishing, templates, grooves, holes, lifting, scaffolding, transportation, wastage, fixing accessories and all leads and lifts.Boundaryy wallCol. & BeamColTop Beam SidesSidesRailing WallMisc |
| 228 | Electrical S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 20 mm |
| 229 | 25 mm |
| 230 | 32 mm |
| 231 | P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 232 | LT PANELSSITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- (a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra ). (d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. (f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra ) (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 233 | Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade |
| 234 | Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .Three phase Ammeter with Inbuilt Selector Switch |
| 235 | Three phase Voltmeter with Inbuilt Selector Switch |
| 236 | Three phase AMP+HZ+PF+KW+KVA+KVAR+T.ENERGY+THD-I, THD-V & RUN HRS |
| 237 | Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Resin cast wound type CT C T Class 1, Ratio upto 150/5, Burden 5 VA |
| 238 | C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA |
| 239 | C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA |
| 240 | C T Class 1, Ratio 1600/5 to 3000/5, Burden 15 VA |
| 241 | Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .Red/yellow/Green colour |
| 242 | Blue / white Colour |
| 243 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .3.3 KV, class A 2 mm thick with proof voltage 10 KV AC (rms) and Break Down Voltage 30 KV AC (rms) |
| 244 | 11 KV, Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage 45 KV AC (rms) |
| 245 | Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs (temp class - 25 D) in 440 V/480 V Capacitor and for 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D) including making connections, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .Heavy duty Three phase 440 V, 50 Hz cylindrical type capacitor (Bank) |
| 246 | Providing & Fixing of IP54 microprocessor based 3 CT’s for all 3 phase sensing compensation power factor correction relay Size 139mm x 139 mm, Operating Voltage 415/440 V , IEC / EN 61000-6-(2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and 3 no. Class- 0.5 Cast Resin CT ( refer CT specs in this chapter )for sensing the relay including making coonection with 1.5 Sq.mm copper wire etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .12 to 16 stage |
| 247 | Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 3 pole Power contactors with following AC 3 Rating.. 300 Amp |
| 248 | 4 pole Power contactors with following AC 1 Rating.40 Amp |
| 249 | 63 Amp |
| 250 | Providing & Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per PWD specification for electrical Works, IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .upto 6 KVAR |
| 251 | 10 KVAR |
| 252 | 25.0 KVAR |
| 253 | 50.0 KVAR |
| 254 | 100 KVAR |
| 255 | SITC of Draw out type 3/4 pole door interlock Air Circuit Breaker (ACB) as conforming to IS/IEC 60947 P - 2 :2003 in existing LT panel suitable for LT installation 440 V, 50 Hz and having adjustable over load short-circuit, Instantaneous , earth fault (LSIG) with separate LED indication for each type of fault shall confirm to EMI/ EMC test , LCD/LED display, last 10 trip history, provision of ZSI, Communication, Power metering module, Thermal memory , trip free mechanisum , suitable for ambient 50 degree and utilization catagary B. In built electrical & mechanical anti pumping feature , 100% rated neutral . ACB shall have separate indication for service, test, isolation & maintenance position, Breaking capacity Icu = Ics = Icw ( 1 sec ) , U imp - 12 KV, break time not more then 25 ms. Provision for electrical & mechanical interlock between ACBs, Min.electrical operation 10000 upto 2000 A rating and 5,000 for 2500 A to 4000 A. including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. Microprocessor based release Draw out type ( Motorised charging type ) 4 Pole800 A Rating ,50 kA |
| 256 | 1000 A Rating , 50 kA |
| 257 | 1250 A Rating ,50 kA |
| 258 | 2000 A Rating ,50 kA |
| 259 | Supply and fixing of following accessories for Air circuit breaker (ACB) compatible with MAin ACB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .Shunt Trip Release |
| 260 | Under voltage Release |
| 261 | Microswitch for Indication |
| 262 | Auxiliary Contact 4 NO + 4 NC |
| 263 | Breaker Control Switch (TNC) |
| 264 | Supply and fixing of following accessories for Moulded case circuit breaker (MCCB) compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .Extended Rotary Handle |
| 265 | Spreaders for 160A, 4 Pole MCCB |
| 266 | Spreaders for 250A, 4 Pole MCCB |
| 267 | Spreaders for 400A, 4Pole MCCB |
| 268 | Spreaders for 630A, 4Pole MCCB |
| 269 | Spreaders for 800A, 4Pole MCCB |
| 270 | Phase Barriers up to 630A, 3/4Pole MCCB |
| 271 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR.4 pole MCCB With Thermal Magnetic release125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 272 | 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 273 | 250 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 274 | 400 Amp , 35 kA, adjustable O/L & adjustable S/C setting, |
| 275 | 630 Amp ,50 kA, adjustable O/L & adjustable S/C setting, |
| 276 | 800 Amp , 50 kA, adjustable O/L & adjustable S/C setting, |
| 277 | 4 pole MCCB With Microprocessor based release with adjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection.630 Amp , 50 kA |
| 278 | LT CABLESProviding & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR6.0 Sq. mm. 4 core |
| 279 | 10.0 Sq. mm. 4 core |
| 280 | 16.0 Sq. mm. 4 core |
| 281 | 25.0 Sq. mm. 3.5 core |
| 282 | 70.0 Sq. mm. 3.5 core |
| 283 | 95.0 Sq. mm. 3.5 core |
| 284 | 120.0 Sq. mm. 3.5 core |
| 285 | 150.0 Sq. mm. 3.5 core |
| 286 | 185.0 Sq. mm. 3.5 core |
| 287 | 240.0 Sq. mm. 3.5 core |
| 288 | 300.0 Sq. mm. 3.5 core |
| 289 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 6.0 Sq. mm3 core |
| 290 | 4 core |
| 291 | 10.0 Sq. mm 4 core |
| 292 | 16.0 Sq. mm. 4 core |
| 293 | 25.0 Sq. mm.4 core |
| 294 | CABLE TERMINATIONSupplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .3.5 x 25.0 sq.mm |
| 295 | 3.5 x 70.0 sq.mm |
| 296 | 3.5 x 95.0 sq.mm |
| 297 | 3.5 x 120.0 sq.mm |
| 298 | 3.5 x 150.0 sq.mm |
| 299 | 3.5 x 185.0 sq.mm |
| 300 | 3.5 x 240.0 sq.mm |
| 301 | 3.5 x 300.0 sq.mm |
| 302 | 4 x 6.0 sq.mm |
| 303 | 4 x 10.0 sq.mm |
| 304 | 4 x 16.0 sq.mm |
| 305 | Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty Copper lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tape for following size of PVC insulated & PVC sheathed/ XLPE copper conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .3 x 6.0 sq.mm |
| 306 | 4 x 6.0 sq.mm |
| 307 | 4 x 10.0 sq.mm |
| 308 | 4 x 16.0 sq.mm |
| 309 | 4 x 25.0 sq.mm |
| 310 | Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .100mm x 50mm x 1.6mm |
| 311 | 150mm x 50mm x 1.6mm |
| 312 | 300mm x 50mm x 1.6mm |
| 313 | 450mm x 50mm x 2.0mm |
| 314 | Supply and fixing following size of Hot dipped Galvanized (275 GSM) floor raceways / Under floor trunking with/ without partion, including common cover, joint sleeve, cross over junction Box etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .100 mm x 38 mm x 1.5 mm |
| 315 | 150 mm x 38 mm x 1.5 mm |
| 316 | 300 mm x 38 mm x 1.5 mm |
| 317 | LANDSCAPE DB & MCBProviding & Fixing of Recessed/surface mounting heavy duty Flexi / Row type Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (metal or Glazed) complete with 100 Amp. copper shorting link , neutral link, earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. Double door IK-09 & IP-43 with metal End box3 Row 42 Module(14 module per row) with provision of 160 Amp. MCCB |
| 318 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. Single pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating |
| 319 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 4 pole MCCB With Thermal Magnetic release125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 320 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR2 x 2.5 sq. mm. + 1x1.5sqmm |
| 321 | TRANSFORMERSSupply installation testing & Commissioning of Copper wound distribution Transformer of following rating and % Impedance, 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled losses as per IS 1180 part I 2014 (Fourth Revision) Level-1, with boltless core design including standard accessories like conservator with prismatic oil level gauge , silica gel breather, Bucholz relay, pressed steel radiator fins, Radiator Valve(above 800 Kva) Suitable size HT cable box, LT cable box with Busbar connection for outgoing cables, Off -LTC (+/- 2.5%, +/- 5% to - 7.5% ), temperature rise of 40 degree C in oil / 45 degree C in winding , drain valve, Air release device, Dial type Oil & Winding Temperature gauge with alarm & trip contacts, first filling of transformer oil as per IS :335-1953 , Epoxy primer and PU based paint as Top coat, Unidirectional rollers for rating upto 800 kva & bi- directionalabove 800 Kva rollers with locking arrangement etc. as required. The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including Temperature rise test in OEM's own lab shall be witnessed by Department engineer Physically. Transformer shall be tested from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor)Following tests shall be carried out on each transformer at site by OEM enginer in presence of department authorised representative:- a) Ratio test on each tapping.b) Resistance of windings at principal and all tapings.c) Insulation resistance of the winding between HV to earth / HV to LV / LV to earth.d) Vector group test.e) Magnetic Balance test. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 1250 KVA with % Impedance 5 |
| 322 | HT SIDE EQUIPMENTSSITC of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, outdoor duty (IP54) , Extensible / Non extensible type Ring main unit (RMU) manually operated in combination of VCB modules and Load Break switch consisting of Copper busbar in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFL classification for gas tank. Vacum Interrupter of VCB should be RMU Manufacturer’s own make. Each feeder of RMU should have voltage presence indicator. . and compring of followings:- 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. - 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB.- 1 No. Manometer for each tank,- 1 nos. Fault Passage indicator,-Right angle boots for all the feeder Modules All the type test certificates as per IEC from Third party NABL / CPRI / ERDA accrediated lab to be submitted. (Cost of RCC Foundation / Steel Structure to be paid Extra) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR Extensible 2 way RMU with 1 no. VCB & 1 No. Load Break Switch |
| 323 | Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .3 core 185.0 Sq.mm |
| 324 | Add Extra for Laying of one number additional XLPE power cable of 11/33 KV (Earthed) voltage grade direct in ground in the same trench in one tier horizontal formation including excavation of trench of size additional 20 cm in width, with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay another cable in middle of trench in such manner that spacing between another cable is 20 cm, (c) Provide sand bed of height 125 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.) (e) Backfill the excavated soil leaving 300 mm from the Ground level. (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth |
| 325 | Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. including testing etc. as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 11 KV End Termination Kit Indoor type3 core 120/150/185 Sq.mm |
| 326 | 11 KV End Termination Kit Outdoor type. 3 core 120/150/185 Sq.mm |
| 327 | 11 KV Straight Through Joint Kit .3 core 120/150/185 Sq.mm |
| 328 | Providing and laying Non Pressure NP-3 class R.C.C. pipes confirming to IS:458 including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) etc. as required. (Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra).200 mm Dia. |
| 329 | 300 mm dia |
| 330 | SITC of HT metering cubical panel (as approved By DISCOMs) fabricated from 20 SWG CRCA sheet steel having two compartments & MS angle of size 60mmX 6mm. It should have provision for Following: (i) fixing Trivector / Import - Export Meter (To be supplied by DISCOMs) (ii) fixing of combined CT PT Set with Copper strip for Connection (To be supplied by DISCOMs), (iii)Test terminal Block, (iv) 6mm thick Bakelite sheet on all sides, (V) 3/6 corex 1.5 / 2.5 Sq.mm copper cable for interconnections, etc. as required. . |
| 331 | EARTHING Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 332 | Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 333 | Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 25mm x 3mm copper strip |
| 334 | 30mm x 5 mm copper strip |
| 335 | 25mm x 3mm G.I. ( Hot Dipped ) Strip |
| 336 | 25mm x 6mm G.I. ( Hot Dipped ) Strip |
| 337 | 8 SWG copper Wire |
| 338 | 8 SWG G.I. ( Hot Dipped ) Wire |
| 339 | SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H & IA) 1500 RPM Diesel Engine conforming to BS:649/5514 of suitable BHP (up to 82.5 kVA 6 cylinder or Below required, 125 kVA & Above ratings 6 cylinder or above required ) capable of taking 10% over loading for one hour after 12 hours of continuous operation., Dry exhaust mainfold with Hospital grade silencer and catalytic convertor(isolated from main DG chamber), up to 3 M exhaust piping (with LRB insulation & Alum. cladding ) as required .B) AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS/IEC 60034-1. . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled C) CPCB / ARAI approved Standard canopy with Weatherproof, powdercoated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with sidewall fabricated from 1.6 mm CRCA sheet & filled with glasswool (96Kg/m3) / Foam. as per IS8183 the doors of 28/40/50/85mm thick as perrating and fabricated from 1.6mm CRCA sheet packed with accoustic material, All doors/opening are sealed with neoprene /EPDNgaskets. The DG Set has Inbuilt / External in fuel tank to run 6 to 8 Hrs as per OEM standard, with protection and tripping of DG set against temperature of more than 50 degree centigrade.D) Electronic / Mechanical governor, Manual & electric Start ,Batteries with battry charger, Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Panel mounted MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity :E) (i) Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA. (ii).Accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA. (iii)Accoustic glass wool wall thickness should not be less then 100mm for rating above 250 KVA.F) First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department.G) Servicing Contract of DG Set from OEM's Authorised Service Dealer as per OEM guidelines during the DLP period shall be done by contractor including all consumables, actual charges shall be reimbursed to the contractor by End User Department.H) Manufacturer / OEM must have its authorized service dealer in Rajasthan. Which can provide service within 6 Hours of compalint registration. I) DG set will be offered for Inspection and Testing at Manufacturer's Works in presence of Departmental Engineers. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 250 KVA at 0.8 pf 415V 50Hz 3-ǿ |
| 340 | 750 KVA at 0.8 pf 415V 50Hz 3-ǿ |
| 341 | PANEL EQUIPMENTLIGHTNING PROTECTION (NON-BSR)Rates shall also include the following : All fixing accessories such as brass saddles, brass screws rawl plugs etc. Jointing by rivetting and brazing after rivetting in case of copper and by welding / bolting in case of GI. Cutting chases, holes and making good the same wherever required.. Effecting adequate and proper interconnections. Use of copper thimbles. Lightning protection system shall comply to IEC/ IS: 2309 - 1989. All earthing pits shall be interconnected.LIGHTNING PROTECTION: SUPPLY, INSTALLATION, TESTING AND COMISSIONING OF ESE LIGHTENING PROTECTION SYSTEM. Lightning Protection AirterminalEarly Streamer Emission (ESE) Lightning protection Airterminal - should be complies with NFC - 17-102 standards. The Airterminal should be capable to collect the ambient electric field and to should emit the upward streamer with the defined Gain in time. Model to be selected for class I coverage for 58 m of radius |
| 342 | Mounting Mast (Pole) .3 m high GI pipe fabrication support structure providing with suitable base plate, should have provision for Guy wire clamping system, termination arrangement for the Down-Conductor |
| 343 | Lightning Strike Counter .Lightning Flash counter working electro mechanically without any power supply. Equipment should count lightning strokes of 0.4KA to 220 KA. |
| 344 | Down Conductor & Accessories. Supply and fixing of down conductor with complete fixing accessories and termination (1 x 70 Sq. mm copper with high voltage isolator supports). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysDec 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender