Tender For Upgradation Of Existing Package Air Conditioning Cooling System Capacity With Indoor Ducting System Throw & Return Modification, Add-On Fresh Air Intake, Damper Control Arrangement, New Idu & Odu Installation, With Necy. Dismeltation, Rest
Tender Overview
Project Description
Tender for Upgradation Of Existing Package Air Conditioning Cooling System Capacity With Indoor Ducting System Throw & Return Modification, Add-On Fresh Air Intake, Damper Control Arrangement, New Idu & Odu Installation, With Necy. Dismeltation, Restoration And Allied Associated Interior Vent Work & Specified Green Dg Supply At Its Capacity At Hooghly Zilla Parishad For New Building Ac Meeting Hall.Air Conditioning Part (B)
BOQ
| Sl. No. | Item Description |
| 1 | PAC HIGH SIDE PART: |
| 2 | Supplying & delivery (incl. carriage) of 415V 3Ø High efficiency Air Cooled Ductable Floor Mounted R410 refrigerent Based Top Discharge PAC Unit with 1 Nos 11 TR ODU & 1 Nos 5.5 TR ODU/3 Nos 5.5 TR ODU conjugated having Wired Remote & Microprocessor based LCD controller Comprising compressor (Hermetically Sealed Scroll Type) ambient temp. not less than 50 degree C, capable to run upto 90% of its rated capacity & COP not less than 3.6 with Cooling system in following capacity.(Make: BlueStar) or Similar specs. from General/Trane/Mitsubishi Heavy Industries Ltd./ Bosch |
| 3 | 16.5 TR (Cooling Capacity: 58 kW/198000 BTU/Hr; Air Flow: 6600 Rated CFM, Sound Pressure Level < 59dBA; Rated Amps 38A; Rated Power 216800 KW) Capacity |
| 4 | PAC LOW SIDE PART: |
| 5 | Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings and specifications of following sheet thickness complete as required. (DSR E&M 25/Pg228/30.12.2) |
| 6 | Thickness 0.80 mm sheet |
| 7 | Thickness 1.00 mm sheet |
| 8 | Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell 19 mm Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. (DSR E&M 25/Pg230/30.23) |
| 9 | Supplying and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminium sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound in confirmation to SMACNA/IS and as per specifications complete etc.as required.. (DSR E&M 25/Pg229/30.21) |
| 10 | Supplying and fixing Flexible Rexine Canvas Connection to the Grill complete with metal frame clippings suitable to IDU Mouth of min. 400 mm length. |
| 11 | Supply of suitable size G1/G2 Grade Mess filter with Aluminium extruded frame for IDU. |
| 12 | Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required. (DSR E&M 2025/pg229/30.17) |
| 13 | Supplying, Fixing, installation, testing and commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required. (DSR E&M 2025/pg229/30.18) |
| 14 | Supplying, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to SMACNA/IS and as per specifications complete etc. as required (DSR E&M 2025/pg228/30.13) |
| 15 | Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire for integration within AHU room complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to SMACNA/IS and as per specifications complete etc. as required [Dampar Only, without Actuator] (DSR E&M 2025/pg228/30.14) |
| 16 | Supply, installation, testing and commissioning of Mechanical Fire dampers in supply air duct/main branch and return air path with inbuilt mechanism of spring return action with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to SMACNA/IS and as per specifications complete etc. as required [Fire Dampar Only, without Actuator] (DSR E&M 2025/pg351/30.71) with Fixing 3/10 |
| 17 | Lifting, Positioning & Installation of Package Air Conditioners ODU Unit(s) and necy. fixing work and pipeline & electrical connection complete and gas charging by vaccuming etc. done by OEM authorised installer with certificate and one year basic service. |
| 18 | 5.5 Ton ODU |
| 19 | 11.5 Ton ODU |
| 20 | Lifting, Positioning & Installation of Package Air Cooled Ductable Air Conditioners IDU 16.5 TR and necy. fixing work and pipeline, electrical & control circuit connection complete and gas charging by vaccuming etc. done by OEM authorised installer with certificate and one year basic service. |
| 21 | Supply of Longitudual Angle/Wall Bracket/MS Angle with Suitable size (to be fixed to the wall in suitable means) for installationn of specifed IDU . |
| 22 | Supply & installation of in-line cetrifugal low noise (not more 66 dB) duct fan 300/315 mm with necy connection complete with IDU switching contractor. (Astberg/Carryaire/Kruger or similar eqlv as per EIC) |
| 23 | Supplying, Fixing, installation, testing and commissioning of thermal insulated PVC duct of following sizes duly supported at regular interval as per site requirement etc. in confirmation to SMACNA/IS and as per specifications complete etc. as required. (For Fresh Air Intake) |
| 24 | 100 mm dia |
| 25 | 150 mm dia |
| 26 | Supplying & refiiling of R410A/R32 Gas (florene or Good quality as per EIC) for extra refilling. |
| 27 | Supplying of Un Ar Cu Control Cable of 6 Core 1.5 Sq mm Communication Cable between IDU and Remote (RR/Polycab/Havells or eqlv similar) in 20 mm rigid conduit. |
| 28 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : [DSR E&M 25 pg240/31.14] |
| 29 | 28.58 mm dia (OD) (Hard drawn) |
| 30 | 22.2 mm dia (OD) (Hard drawn) |
| 31 | 12.7 mm dia (OD) (Soft drawn) |
| 32 | 9.5 mm dia (OD) (Soft drawn) |
| 33 | Supply & fixing of PVC Medium Duty pipeline for water drainage of ductable AC with necy. Joining Accessories & conceling if required. [S&P SOR PWD 19(I) a/ pg 12] |
| 34 | 32 mm dia |
| 35 | Applying Nitrile insulation tube on above PVC Pipe incl necy end wrapping tapping etc comeplete. |
| 36 | For 32 mm dia |
| 37 | RCC Core Cutting with 60 mm dia upto 400 mm depth and finishing to the original condition etc to complete. |
| 38 | Ducting Supports different suitable size MS Angles: M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requsite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816-1969 & IS: 1995 using electrodes of approved make and brand conforming to IS: 814- 2004, haulage, hoisting andn erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental changes such as electricity charges, labour insurance charges etc. ii) For Structural Works in Roof Trusses etc. using joists, channels and angles of specified section weighing less than 22.5 kg/m (Ref. Item No. 1 of Page 99 of PWD Schedule of Rates Building Works, Vol I, 2017 & Corrigendam 2018 considerred) |
| 39 | (i) Priming one coat on steel or other metal surfa Electrical Work ce with synthetic oil bound primer of approved quality including sommthening surfaces by sand papering etc. (WRIDD Schedule Rate 4.8.21 pg 4) |
| 40 | (ii) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : with super gloss (hi-gloss) - (iv) Two coats (with any shade except white)(WRIDD Schedule Rate 4.8.21 pg 4) |
| 41 | Testing, Inspection & Commisioning (with required consultation as needed) of Whole PAC System (incl. AC Unit & Duct Design) Certification may be obtained by OEM in specified standard norms & category to Safe Run & Break Down Service if needed with PMS for 12 months. |
| 42 | Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge: (PWD bldg sch pg 23/Sl-3) |
| 43 | a) 3.90 metre height |
| 44 | b) Extra for additional 3.6 mtr height or part there of |
| 45 | BACK UP POWER GENERATION UNIT: |
| 46 | Supply & delivery at site (on pre-made foundation) of 60 KVA, 415 V, 50 Hz, 3Ø silent new Diesel Green Engine driven Alternator set, comprisng of engine compliants CPCB IV+ having suitable Lead Acid battery for self priming with Auto Start-Stop feasibility & battery tickle charging SMPS incorporated etc complete inside a Accoustic approved quality Canopy (which is subject to withstand outside climate condition at least for 10 years) having following specifcations: |
| 47 | Make: Ashok Layland Laypower/Volvo-Eicher//Caterpillar/Perkins/Force-mtu/M |
| 48 | Engine Type: 4 stroke; Displacement: 3.8 L or Higher;CR: 16.5:01;Pollution Norms: CPCB IV+;Cylinders: 4 in-line;Aspiration: Turbo Charged, Liquid Cooled;RPM: 1500; Rated Engine Output: 72 bhp or higher;Governor: Mechanical/Electronic; Class A0/A1/G2;Fuel Consumption: 12 lit/hr @100% rated load, 8.4 lit/hr @75% rated load & 6.3 lit/hr @50% rated load;Duty Type: Prime;Fuel Tank (HSD) Capacity: 140 lit or higher;Ignition: Self, 12V DC system; |
| 49 | Alternator (3Ø) Make: Stamford/Leroy Somer (Nidec)/MitsubishiElectric/Bosch/CG/Hitachi/Siemens/ABB;Type: Brushless & Self excited; 1500 rated RPM;Insulation: Class: H; Voltage regulation: ±1%;Minimum Unbalaced Load Across Phases: 20% or higher;Weather protection: IP23 or higher;Power factor: 0.80 lagging or higher;winding: Star with NeutralRated Output: Current: 83.4 A or higher;Voltage: 400-415V Phasse to Phase & 220-240V Phase to Neutral; Frequency: 50 Hz; |
| 50 | Overload Capaity: 10% overload for 60 minutes for every 12 hrs continuous running;Waveform Distortion: No load < 1.5 %, Non distorting balanced linear load < 5 %;Safety Contol: Emergency Stop Switch External; Lube oil & Fuel Warning/Shut down & Indicator; Battery Charging, Over heat, RPM, Sensor Check Indiactor on board Display or LED. |
| 51 | a) Rate is inclusive of all applicable taxes and Duty etc.b) All materials, equipments & accessories must conform to relavent IS /EC specifications. The DG Set to be supplied must be from the authorized OEM of the respective Engine Manufacturer.c) Nacessary manufacturer's test certificate for Deisel Engine, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.d) Copy of \\"Type Approval Certificate\\" and Certificate of \\"COP\\" must be produced at the time of delivery issued from competant Authority (As per CPCB-IV+).e) The entire set must be warlifted atleast 60 months from the date of Delivery/ 7000 running Hrs from the date of Cornmissioning whichever is earlier. However Engine & Alternator should be warranted of 5 years/7000 Hrs, whichever is earlier. |
| 52 | First Year PMS Service with necy consumabes & Spare Parts like Air Filters, Oil Fiters etc inc PMS labour Cost & Any Break Down Call in a year for 60 KVA CPCB IV+ Green Generator Set. |
| 53 | Total Amount before Taxes |
| 54 | Add GST 18% |
| 55 | Add Labour Cess 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender