Tender For Repair/ Replacement To Leakage Seepage Roof Treatment, Plastering And Misc Work At Aor Of Age B/R-V Under Ge (Mcte) Mhow
Tender Value
30 Lakhs
Estimated cost
Bid Submission
10 Dec 2026
18 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Indore → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Replacement To Leakage Seepage Roof Treatment, Plastering And Misc Work At Aor Of Age B/R-V Under Ge (Mcte) Mhow
BOQ
| Sl. No. | Item Description |
| 1 | M&L for taking down existing waterproof treatment of tar felt of any description from roof surface and removing rubbish to a distance not exec 100 mtrs complete all as specified and directed. |
| 2 | M&L for PCC 25mm thick (1:2:4) type B0 using 12.50mm graded stone aggregate mixed with integral waterproof chemicals mixed in proportion of 200ML/50KG cement as in padding on roof surface for correcting/ making proper slope on roof/ chajja and roof kerbs/ benching complete all as specified and directed. |
| 3 | M&L for Cement concrete tiles 20cm x 20cm x 20mm thick, machine pressed; set jointed neat cement slurry as on roof surface incl cut and polished etc incl 15mm thick cement plaster in CM 1:4, complete all as specified and directed. |
| 4 | Identify the cracks and construction joints, honeycomb areas in slabs/ beams/ columns, shall be chased open into 'U' groove shape and sealed with High strength, fiber based cementitious mortar, Fosroc Renderoc SP40. Providing and fixing 6-8mm dia nozzle along the joints and honeycomb areas after proper surface preparation. The injection of conbextra EP10 through the nozzle till the refusal of the grouting materials complete all as specified and directed. |
| 5 | Supply & providing water proofing roof treatment with polymeric standard water proofing membrane, having 10 years gurantee for water tightness complete all as specified and described as under:-(a) Preparation of RCC roof surface and applying one coat of polymeric modified bitumen 85/25 @ 1.2Kg/Sqm over a coat of polymeric primer @ 0.30 Kg/sqm including cleaning surface all as per manufaturer's specification complete all as specified and directed. (b) Supply & providing water proofing with 3mm thick APP polymeric proofing membrane of 3Kg/Sqm consisting of 100micron HMHDPE film centre core including coating the surface with compatible primer and torch application of membrane with 10cm overlaps as required thereof, complete all as specified and directed. (c) Aluminium bituminous paint @1.10 Kg/Sqm shall be applied over the APP membrane surface.Note:- The work of water proofing treatment shall be got executed through expert team of manufacturers or authorised applicator of manufacturer. |
| 6 | M&L for water proofing on roof/parapert with the following steps:Step I : Surface Preparation: All loose and de-bonded concrete/ screed, loose particles, dirt & should be removed. Roof substrate must be pressure-washed with water with, a minimum working pressure of 1,400 psi is to be used to and/or remove all dirt, dust, chalking and waster products. Remove algae,mold by using bleach solution or biowash.Step II : Surface Repair:Concrete roof screed more than 0.50mm and not giving hollow sound, should be cut and widenin V shape with mechanical cutter in the size (10mm W x 6mm D). Apply a coat of (Dr. Fixit Pidiprime A/ Equivalent make) on the well-prepared groove; allow the coat to dry for 30 minutes before application of (Dr. Fixit PU/ equivalent) seal and withsuitable gun. Allow sealant to cure a minimum 72 hours.Step III : Screed Repair:Remove loose and damaged concrete roof screed in pockets with mechanical cutter. Clean the concrete screed with high pressure water jetto remove dirt and loose particles. Brush apply abondcoat of (Dr. Fixit Pidicrete URP mix/ equivalent) in the ratio of 1:1 (URP 1: Cement 1) by volume to makeit lump free slurry when applied on in the pre wet surface. Laid to fall roofscreed in correct slope and gradient. Mix Dr. Fixit Pidicrete URP 10%/ equivalent byweight of cement in (M20) concrete in ratio of 1:1.5:3 i.e., one bag of 50kg cements: 1.5 times volume of sand: 3 times volume of aggregates: 25L water. Level the repair mortar and finish with trowel. Moist cure should bedone for 7days. Air cure screed for 7days, before application of roof top coatcoating system.Step IV : Rain water outlets treatmentHacking and chipping the surface around the rainwater drain outlet up to 25mm in depth. Apply bond coat of Dr.Fixit Pidicrete URP/ equivalent in the ratio of 1:1 (URP 1: Cement 1) by volume over the corners and pipe insert outlet gaps. Filling the gaps around drain mouth with (PMM) polymer modified mortar mixed with Dr. Fixit Pidicrete URP 10%/ equivalent by weight of cement in the ratio of 1:3. Providing & fixing 100mm width 45gsm glass fiber mesh all around the periphery of drain mouth of rainwater outlet sand wiched with Dr. Fixit Roof seal Classic/ equivalent. Apply the second coat of Dr. Fixit Roof seal Classic/ equivalent with an interval if 5-6 hoursall over the rain water outlet. |
| 7 | M&L for cutting/ making grooves/ opening to existing tile/ kota stones joints including cleaning the joints completely using high pressure air blower and providing & applying Nitotile EPW or equivalent hygienic, stain-resistant, with a high degree of resistance to chemical attack, abrasion and impact. Nitotile EPW is a grouting material of highest quality that provides aesthetic effect and durability, it perfectly prevents stains, spillage chemical attack to filled joints of tiles & stones (size of joints -2/3/4mm width x thickness of tiles). Compressive strength (ASTM 579)> 75 N/mm2 (7 days),Shrinkage % (ASTM D 955) < 0.1%,Tensile strength (BS 6319) >10 N/mm2 (7 days), Pot life @ 27oC 45 mins. Maximum & Light Foot traffic 24 hrs. |
| 8 | M&L for repair to sunken floor by provide water proofing treatment to sunken floor surfaces of RCC slab by the following specifications as specified and directed.(a) Demolition of old sunken surfaces complete and cleaniong of all loose particles and apply cement slurry @3.00 kg/ sqm on old surfaces by brushing.(b) Provide PCC 1: 1.5:3 type A with using 12.5mm graded stone aggregate in slope of average thickness 50mm on sunken floor slab mixed with and including integral water proofing compound manufactured by Dr FIXIT or equivalent as approved, finish the surface even & smooth without using extra cement. (c) Rendering 15mm thick in CM 1:3 mixed with & including integral water proofing compound on sunken floor and sides of (Vertical surface) sunken portion. (d) After laying of all sewage/ plumbing pipes with fixtures in position, apply two coats of polymeric based chemical pidifin 2k by pidilite as per manufactures instructions over bottom and sides of sunken portion upto 600mm height, complete all as specified and directed. (e) Fill the sunken floor with PCC 1:5:10 type E-2 using stone/ brick aggregate. (h) Fixing of 40mm dia CPVC pipe connecting upto bathroom outlet pipe shall be provided to drain out seepage water if any. (j) Testing of sunken as per specification mentioned in SSR Part-I/ P.S. |
| 9 | M&L for Non Skid ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 10 | M&L for Glazed Coloured ceramic tiles (textured and designed as required) in vertical surfaces size 450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick backing coat in CM 1:3 complete all as specified and directed. |
| 11 | Taking down old GI tubing ISI marked medium grade 15mm bore with all fittings including connection etc, complete all as specified and directed. |
| 12 | Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and directed. |
| 13 | S&F in repairs PVC (SWR) Floor trap/Nahani trap plain or multi with stainless steel grating incl joinig to waste pipe with solvent cement joint dia of outlet 110mm bore complete all as specified and directed. |
| 14 | S&F in repairs 110mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trench complete all as specified and directed. |
| 15 | S&F in repair 110mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed. |
| 16 | S&F in repair 110mm bore PVC (SWR) bend any radius complete all as specified and directed. |
| 17 | S&F in repair 110mm bore PVC (SWR) bend with acess door complete all as specified and directed. |
| 18 | S&F in repairs 75mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trench complete all as specified and directed. |
| 19 | S&F in repair 75mm bore PVC (SWR) bend any radius complete all as specified and directed. |
| 20 | S&F in repair 75mm bore PVC (SWR) bend with acess door complete all as specified and directed. |
| 21 | S&F as in repair 40mm Bottle trap of CP having minimum water seal of 25mm (Minimum weight 32mm-260gms/ 40mm-270 gms) complete all as specified and directed. |
| 22 | S&F in repair Waste coupling of 40mm dia PVC (half or full threaded) (Minimum weight 32mm-45gms/40mm-60 gms) fixed in repair complete all as specified and directed. |
| 23 | S&F in repair LDPE pipe of dia 32mm waste pipe of pressure rating 6 kgf/ cm2 fixed complete to walls, ceilings or in floors etc.fixed to any type of coupling complete all as specified and directed. |
| 24 | M&L for provide PVC spout pipe of 25mm bore & 45cm length in sunken floor including cutting holes in brick walls built in cement mortor and making good the dismantled portion in PCC (1:2:4), type B1 with using 20mm graded stone aggregate with wall finish at the disturbed portion of external surfaces complete all as specified and directed |
| 25 | S&F in repair CP WHB mixer for mixing hot & cold water screwed down for iron pipe 15mm bore complete all as specified and directed. |
| 26 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed. |
| 27 | S&F in repairs Plastic water closet seat cover, white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 28 | S&F in repairs PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed. |
| 29 | S&F in repair Vitreous China wash basin, angle back, size 550 x 400mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed. |
| 30 | S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 31 | S&F in repair angular stop valves, cast copper alloy, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for 15mm dia CPVC/ Iron pipe or for unions and fixed complete all as specified and directed. |
| 32 | S&F in repair Long body CP Bib taps, cast copper alloy with crutch or butterfly handle, sc-rewed down, screwed for 15mm dia CPVC/ iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 33 | S&F in repair Bib taps, cast copper alloy with crutch or butterfly handle, sc-rewed down, screwed for 15mm dia CPVC/ iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 34 | S&F in repair Brass CP wall mixer for mixing hot & cold water screwed down for 15mm dia CPVC/ iron pipe and fixed complete all as specified and directed. |
| 35 | S&F in repair Brass CP Tubular towel rail, 20mm dia, D type, 60cm long between flanges fixed complete all as specified and directed. |
| 36 | S&F in repair chromium plated shower roses 125mm sizes with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed. |
| 37 | S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 38 | S&F in repair 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 39 | S&F in repair PVC mirror cabinet of size 600 x 450mm complete all as specified and directed |
| 40 | M&L in repair for Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe 1.25 M long flexible tube and ABS wall Hook including making connection and fixed in position complete all as specified and directed. |
| 41 | M&L for cutting holes in brick walls built in cement mortar at the starting point of down take soil/ waste pipe at any floor, fill the joint of down take pipe & trap with thick mortar in CM 1:3 and making good the dismantled portion in PCC (1:2:4), type B1 with using 20mm graded stone aggregate with wall finish at the disturbed portion of external surfaces complete all as specified and directed. |
| 42 | S&F of CPVC Brass Elbow for 20mm outer dia pipes complete all as specified and directed. |
| 43 | S&F of CPVC Brass Tee for 20mm outer dia pipes complete all as specified and directed. |
| 44 | S&F of CPVC Male Brass Threaded Adaptor (MTA/ MBTA) ) for 20mm outer dia pipes complete all as specified and directed. |
| 45 | S&F of CPVC Female Brass Threaded Adaptor (FTA/ FBTA) for 20mm outer dia pipes complete all as specified and directed. |
| 46 | Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc. |
| 47 | M&L for 15mm thick cement plaster in cement mortar 1:6 on brick or concrete surface etc. on wall finished even and smooth without using extra cement, complete all as specified and directed. |
| 48 | M&L for rendering 15mm thick in CM 1:4 on brick or concrete surfaces finished even and smooth without using extra cement all as specified incl mixing with water proofing compound complete all as specified and directed. Note:- (WPC shall be measured and paid separately). |
| 49 | M&L for 10mm thick cement plaster in cement mortar 1:3 on brick or concrete surface etc. on in ceiling finished even and smooth without using extra cement, complete all as specified and directed. |
| 50 | Supply only liquid water proofing compound complete all as specified and directed. |
| 51 | M&L for distemper with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gm/litre of approved manufacturer of required shade and colour complete manufacturer, applying two or more coats on new worand including 3mm thick wall putty complete all as specified and directed. |
| 52 | M&L for preparing new plastered surface of ceiling surface and applying three coats of white wash etc complete all as specified and directed |
| 53 | M&L for applying two or more coats of 100% Premium exterior acrylic emulsion paint latex based having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of equired shade (Company Depot Tinted) with silicon additives @ 1.43 liter/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10sqm or old wall surface including preparation of old surface complete all as specified and directed. Note:- (i) contractor shall furnished guarantee for four years againts service rendered). (ii) primer and emulsion tobe carred out through air less spray machine (mechanical means). |
| 54 | Dismantling of Plain or corrugated steel/ AC sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 55 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 56 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 57 | S&F Steel work in tubular trusses, purlins etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240etc complete all as specified and as directed. |
| 58 | M&L for preparation of new steel surfaces of any description ,over 10 cm width or girth and applying two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed. |
| 59 | Taking down steel tubing & connections including cleaning for refixing serviceable pipe or removal balance pipe of 20mm dia bore complete all as specified and directed |
| 60 | All as per ser item No. 59.00 above but 25mm dia bore complete all as specified and directed. |
| 61 | S&F medium grade galvanized steel tubing (concealed) with all fittings & fixed complete to walls & ceiling or laid in floors 20mm dia bore pipe (including in short length) complete all as specified and directed |
| 62 | All as per ser item No. 61.00 above but 25mm dia bore complete all as specified and directed. |
| 63 | S&F in repair 25mm dia Gun-metal, golbe or gate valves, with iron wheel head, screwesd both ends or iron pipe and fixed complete all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysDec 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender