Defence Statutory Bodies & Commissions/Committees Closing in 12 days TDR #58633245

Tender For Repair / Maintenance Of Sewage / Boundary Wall / Pathway At Rpd Complex Under Ge (West) Mathura

Issued by Statutory Bodies & Commissions/Committees · Mathura, Uttar Pradesh
Tender Value
45 Lakhs
Estimated cost
Bid Submission
04 Dec 2026
12 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mathura → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Sewage / Boundary Wall / Pathway At Rpd Complex Under Ge (West) Mathura

BOQ

Name of Work:- REPAIR / MAINT OF SEWAGE / BOUNDARY WALL / PATHWAY AT RPD COMPLEX UNDER GE (WEST) MATHURA
Sl. No. Item Description
1Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
2Demolition of brick work or stone/boulders masonary, built in cement mortor including all quoins, arches pillars, etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed.
3Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thick above or below ground level complete all as specified and directed.
4Demolition of cement (reinforced) concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge.
5Dismantling posts or struts ( wood, steel or RCC) embedded in concrete, brick work etc, any section and any length including taking out embedded portion and making good disturbed ground complete all as specified and directed by Engineer-in-Charge. Note :- Dismantling of existing galvanised iron steel barbed wire / chain link fencing shall be measured and paid for separately.
6Dismantling chain link fencing of any guage & size not exc 4 Kg/Sqm complete all as specified and as directed.
7Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified and directed.
8Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded, jointed and pointed in any mortar complete all as specified and directed by Engineer-in-charge.
9Demolition and breaking up drain pipes, set in cement mortar 200mm internal dia (SGSW, AC or reinforced concrete) complete all as specified and directed.
10Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
11Dismantling of PVC fiber sheets in roof covering / wall complete all as specified and directed.
12Excavating in post holes (or similar holes) each not exc 0.50 cum in soft / loose soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and directed by Engineer-in-charge.
13Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.50 mtr depth for foundation etc or for shafts, wells, cesspits, main holes, pier holes etc complete in soft/loose soil complete all as specified and directed.
14Returning, filling in soft/loose soil including spreading, leveling and watering well ramming in layers n.exc. 25cm all specified and directed.
15Removing excavated soil to a distance not exceeding 50 metere and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
16M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
17All as per Srl item No 16.00 here-in-before but except brick.Note : Old serviceable brick retrieved from serial item No 2.00 of BOQ here-in-before shall be used under this item.
18M&L for brick work with sub class ‘B’ old size burnt bricks in one brick thick honey comb walling built in cement mortar (1:4) complete all as specified.
19M&L for rendering 15 mm thick in CM 1:4 including water proofing compound @ 200 ml/bag of cement used on fair face of brick or concrete surface, finished even and smooth without using extra cement complete all as specified and directed.Note : Supply only WPC shall be measured and paid seperately.
20Supply only Liquid water proofing compound of approved complete all as specified and directed.
21M&L for preparartion of new plastered surfaces of walls and applying two coats cement base paint on walls complete all as specified and directed.
22M&L preparation of new plastered surfaces and applying two coats of exterior weather coat and primer on walls all as specified.
23M&L for cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, coping, parapets and railing upto 60cm height, copings bed block,roof kerbs or mud stops, kerb stone, kneelers, apex stones, bed plates, surface channels and drains, benching, haunching water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed.
24M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
25M&L for preparation of old painted surface of wall of any discpription and applying two coat of exterior emulsion paint of Dark Shade complete all as specified and directed.
26M&L for preparation of old steel surfaces of any description or girth over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
27M & L for complete removal of existing treatment and preparartion of old surfaces of walls and applying two coats of cement based paint on walls etc complete all as specified and as directed.
28M&L for 75 mm thick Cement concrete type D-2, (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
29M&L for sand filling under floors or in foundation complete all as specified and directed.
30M&L for Machine pressed precast conctete interlocking paver block of yellow/red colour & pigment any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed.
31M&L for vitrified paving tiles (any colour) of size 30cm x 30cm x 10mm thick, with gray cement & pigment set, jointed and pointed in neat cement slurry in floors laid over and including 15mm screed bedding in cement mortar (1:4) complete all as specified and directed.
32M&L for cement concrete (1:3:6) type C-1, using 20 mm graded stone aggregate as in surface channels or drain complete all as specified and directed.
33Extra for forming fair finished drain or channel 45 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc. complete all as specified and directed by Engineer-in-charge.
34Raking out joints/ pointing to brick work in walls or to bricks on edge in floors, surface channels, roofs, etc. complete all as specified & directed.
35M&L for keyed pointing in cement mortar 1:3 to brick wall complete all as specified and directed.
36S&F 75-80mm thick factory made precast RCC manhole covers including precast frame of any size & shape (Squre / rectangular / circuler), light duty, out side, fixed at site etc complete all as specified and directed.Note : Reinforcment required shall be included in quoted item rate.
37M&L for reinforced cement concrete (nominal mix) (1:2:4) type B1, using 20mm graded stone aggregate as in slab for drains, culvert complete all as specifed and directed and directed. Note : Reinforcement shall be measured and paid seperately).
38Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished of flat surface complete all as specified and directed.
39Formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide fair finished surface of concrete complete all as specified and directed by Engineer-in-Charge.
40M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
41S&F MS screw bolt 05 to 10mm dia, length of bolt not exceeding 50mm long machine made with hexagonal or square head at one end and screwed the other or serewed both ends, each screwed end fitted with washer and one hexagonal or square nut complete all as specified and directed by Engineer-in-Charge.
42M & L for PCC (1:3:6) typeC-2 using 40mm graded stone aggregate as in foundation for post & struts & mass concrete including necessary form work and fair finishing complete all as specified and directed by Engineer-in-charge.
43Fixing only mild steel galvanized chain link fencing any mesh, size and type to any type of standards, rails, straining bolts etc. including provision of binding wire complete all as specified and directed by Engineer-in-charge.Note :- Supply only chain link fencing shall be measured and paid for separately under respective item of BOQ.
44Supply only mild steel galvanized chain link fencing of any mesh, size and type complete all as specified and directed by Engineer-in-charge.Note:- (i) Flat iron, round bars, nut bolts and washer shall be measured and paid for separately. (ii)The payment shall be made to the contractor for actual weight ascertain by the BOO as odered by GE.
45M&L for mild steel work as in posts and struts in fencing including drilling bolting or riveting etc. wind tie for roof including cutting topes to shape as directed, drilling holes, notching for wire etc, flat iron (for securing wire mesh) conforming to Fe-290 Gde E-165, complete all as specified and directed by Engineer-in-Charge.
46S&F mild steel round bars 10mm dia, cut to length, bent to shape as in tie bar fixed to chain link fencing including necessary welding where required as per site requirement & other similar works conforming to Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in-charge.
47S&F in repair galvanized 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanized mild steel wire, staples or steel pins etc complete all as specified and directed by Engineer-in-charge.Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment.
48M&L for glazed ceramic tiles (coloured) 450mm x 300mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) including necesary cutting as per site requirment complete all as specified and directed by Engineer-in-charge.
49M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mmthick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granit complete all as specified and as directed.
50M&L for Reinforced concrete pipes, class NP2, laid and jointed complete with collars with bore of pipe 200mm laid in trenches and jointed in CM (1:1) complete all as specified and directed.
51M&L cement concrete 1:3:6 mix type C2 (using 40mm graded stone aggregate) as in bed to drain pipe including packing under and hunching against the sides of pipes after laying in trenches to required slope and tested complete all as specified for 200 mm bore pipe complete all as specified and directed by Engineer-in-Charge. Note :- Thickness of concrete bed below the barrel of pipe shall be 15 cm and width of bed shall be outer dia of pipe plus 30 cm.
52S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, cooler stand 12mm sq guard bar, framework of water tanks and similar works of quality Fe 290 (Gde E-165) etc complete all as specified and directed by Engineer-in-charge.
53Dewatering/Cleaning of septic tanks of any depth by getting out sludge, semi solid/solid material etc by pumping/manual means including removal in covered veh to a non habitant area out side the MOD land or buried into ground septic tank complete all as specified.Note :- The contractor shall remove the sewage / sludge and other foreign material from the site by mechanical equipment etc or by way or other any mean to outside MOD land in covered Vehicles ie Veh required for transport of foul matters/gas etc and shall be disposed off as directed by Engineer-in-Charge. The site shall be left by the contractor in neat and tidy condition before claiming his payment.
54Cleaning of sewage lines blocked/filled with sludge, semi solid/solid material etc man holes to manholes by rodding/mechanical means without causing any damage to sewage lines/manholes. Manholes covers and taking out the same and removing to a non inhabitant area or buried into ground all as specified for the internal dia of pipes 150mm dia.
55S&F 110mm bore PVC (SWR) pipes single socketed in any length jointed with adhesive fixed to walls including taking down old unserviceable PVC pipe and fittings complete all as specified and directed.
56S&F green PVC fibre sheet of 2mm thick fixed with coach screw and washer in roof/ wall complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58633245
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 04-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Sewage / Boundary Wall / Pathway At Rpd Complex Under Ge (West) Mathura
Basic Detail
Tender No 8300/1429/E8
Bidding Type Tender
Location
City Mathura
State Uttar Pradesh
Key Dates
Publish Date 20 Nov 2026
Submission Date 04 Dec 2026
Open Date 07 Dec 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
95b4f14d-706e-4dbc-b50f-4a54521f943b.html
BOQ_897159.xls
Tender1429.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

95b4f14d-706e-4dbc-b50f-4a54521f943b.html

xls

BOQ_897159.xls

pdf

Tender1429.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender