Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #58633239

Tender For Provn Of Toilet Blocks For Central Library Bldg Under Ge (West) Mathura

Issued by Statutory Bodies & Commissions/Committees · Mathura, Uttar Pradesh
Tender Value
26.23 Lakhs
Estimated cost
Bid Submission
11 Dec 2026
19 days left
EMD
52465
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mathura → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Toilet Blocks For Central Library Bldg Under Ge (West) Mathura

BOQ

Name of Work:- PROVN OF TOILET BLOCKS FOR CENTRAL LIBRARY BLDG UNDER GE (WEST) MATHURA
Sl. No. Item Description
1Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, laying of cables, walls, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc. 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
2Returning, filling in soft/loose soil including spreading, leveling and watering well ramming in layers n.exc. 25cm all specified and directed.
3Removing excavated materials not exc 50 mtr and deposited where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and as directed.
4Surface excavation n exc 30cm deep and average 15cm deep and getting out in soft/loose soil all as specified and directed.
5M&L for PCC (1:4:8) type D-2, using 40mm graded stone aggregate in foundation, filing and mass concrete complete all as specified and directed.
6M&L for reinforced cement concrete M-25 design mix using 20mm graded stone aggregate as in foundations, including rafts, footings, foundations beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed.
7M&L for reinforced cement concrete M-25 design mix using 20mm graded stone aggregate as for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and other similar works complete all as specified and directed and directed.
8M&L for reinforced cement concrete M-25 design mix using 20mm graded stone aggregate as in beams, cantilevers, bressumers, lintels over 1.5 m span complete all as specified.
9M&L for reinforced cement concrete M-25 design mix using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed.
10Formwork to sides of concrete foundations footings bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work vertical or to batter for rough finished of flat surface complete all as specified and directed.
11Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished of flat surface complete all as specified and directed.
12Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc. for rough finished surface of concrete complete all as specified and directed.
13Formwork to sides of pillers, posts, struts, piers, columns and stanchions of square, rectangular or polygonal for rough finished surface of concrete complete all as specified and directed.
14M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
15M&L for TMT MS bars of 5mm dia and upto 10mm dia as in stirrups and spacers cut to lengh bent to shape reqd incl cranking bending spirally for hooking for column and binding with MS annealed wire not less than 0.9mm dia complete all as specified and directed.
16M&L Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth
17M&L for 75 mm thick Cement concrete type D-2, (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
18M&L Non skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match with and including 15mm thick screed bed in cement mortar (1:6) for laying floor finishes complete all as specified and as directed.
19M&L for glazed ceramic tiles (coloured) 450mm x 300mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) including necesary cutting as per site requirment complete all as specified and directed by Engineer-in-charge.
20M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like including 20mm screed bedding in cement mortar (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
21M&L for Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
22M&L for Brick work with fly ash bricks, straight or curved on plan to any radius half brick thick wall built in CM (1: 6) complete all as specified and directed.
23M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
24M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and directed.
25M&L for rendering 15 mm thick in CM 1:4 including water proofing compound on fair face of brick or concrete surface, finished even and fair without using extra cement complete all as specified and directed.Note:- WPC shall be measured and paid saperately.
26Supply only liquid water proofing compound ISI marked complete all as specified and directed by Engineer-in-charge
27M&L for rendering 5mm thick in CM (1:3) as on ceiling complete all as specified and directed.
28M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
29M&L for preparation of new plastered surface of wall and applying three coats of white wash complete all as specified and directed.
30M&L for complete removal and preparation of old treated surfaces for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @0.90 litre/10 Sqm complete all as specified and directed.
31S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified.
32S&F 4.80mm thick sheet glass selected quality glazing with with rubber for fixing glass complete all as specified and directed by Engineer-in-Charge.
33S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified & shown in relevant drawing of item No. 08095 in MES Schedule (Part-II) and directed by Engineer-in-Charge.
34S&F 30mm thick factory made solid PVC moulded door shutter with particle board core with 5mm thick PVC moulded sheet on the front face and 5 mm thick PVC plain colour sheet on back face complete all as specified and directed by Eng-in-charge.
35S&F 250 mm aluminium alloy, anodised sliding door bolts with hasp, staple and fixing clips of sheet, cast or extructed section and fixing bollts and sliding bolts of extruded section or cast aluminium ally and fixed complete all as specified and directed.
36S&F Aluminium handles cast type anodised of size 150mm size, complete all as specified and directed.
37S&F 150 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified and directed by Engineer-in-charge.
38S&F 100mm long stainless steel Butt hinges fixed complete all as specified and directed.
39S&F 15 mm dia steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge
40S&F 20 mm dia steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge
41S & F rotational moulded polyethylene water storage tank 750 Ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position with all necessary GI fittings complete all as specified in SSR Pt I complete all as specified and directed by Eng-in-charge.
42S&F 20mm dia PTMT ball PVC valve, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-charge.
43M&L for PCC type C1 1:3:6 (20 mm grade aggregate) as in platform for PVC tank complete all as specified & directed.
44S&F vitreous china wash down water closet pan (Pedestal pattern), white including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc. & with plastic WC seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device and jet spray complete all as specified & as directed by Engineer-in-charge.
45S&F CP Jet spray butter fly design fixed on EWC with stanless screw as approve complete all as specified and directed by Eng-in-charge.
46S&F CP Health faucet with stand fixed on wall in CP hose pipe 1 mtr length and stainless steel screw as approve complete all as specified and directed by Eng-in-charge.
47S&F vitreous China wash hand basin, white, flat back size 550 x 400mm including 15mm dia, 450 mm long HDPE PVC connection, 750 mm long 32mm bore HDPE waste down pipe including CI brackets complete all as specified and directed.
48S&F 600mm x 450mm beveled edge looking mirror of selected quality glass not less than 5.5mm thick, mounted on 6mm thick commercial plywood including PVC moulded framing and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by Engineer-in-charge.
49S&F vitreous china urinal Half stall type, white incl CP spreader screwed for iron pipe and fixed complete including providing and fixing plugs with and including 60mm long brass screws, pointed around urinal back in cement, fixing discharge pipr, flush pipe, grating and union for discharge complete all as specified and directed by Engineer-in-charge.
50S&F 10 litre capacity PVC valveless symphonic action type low level flushing cistern (ISI marked) including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified and directed by Engineer-in-charge.
51S&F brass chromium plated tubular towel rail 20mm dia; 'D' type, 600mm long between flanges fixed to plug with chromium plated brass screws including wooden or plastic cleat complete all as specified and directed by Engineer-in-Charge.
52S&F chromium plated Soap dish holder including chromium plated brass screws and plastic cleats complete all as specified & directed by Engineer-in-Charge.
53S&F 32mm Waste fittings, brass, chromium plated for glazed ware wash hand basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified.
54S&F low density poly ethylene pipes (LDPE) of 32mm bore fixed complete to urinal pots all as specified.
55S&F vitreous china urinal partition white of size 310x700 mm. complete all as specified and directed.
56S&F 15mm bore CP angle valve, fancy type, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge.
57S&F 2 way 15mm CP angle fancy type 15 mm bore high pressure screwed for iron pipe complete all as specified and directed by Engineer-in-charge.
58S&F 450mm long PVC connection suitable for 15 mm bore with PTMT nuts on both sides complete all as specified and directed by Engineer-in-charge.
59S&F 15 mm bore bib tap, cast copper alloy, chromium plated, long body, fancy type screwed down and screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge.
60S&F 15mm bore brass chromium plated basin mixer for mixing hot & cold water screwed down for iron pipe of 15mm bore complete all as specified and directed by Engineer-in-charge.
61S&F 110mm bore PVC (SWR) pipes single socketed in any length with solvent joints laid In trenches or fixed in wall complete all as specified and directed.
62S&F 75mm bore PVC (SWR) pipes single socketed in any length with solvent joints laid In trenches or fixed in wall complete all as specified and directed.
63S&F PVC (SWR) 110mm bore bends any radius complete all as specified and directed.
64S&F PVC (SWR) floor trap 100mm dia outlet plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 complete all as specified and directed.
65S&F 110mm PVC (SWR) vent cowl complete all as specified and as directed.
66S&F 110mm bore PVC (SWR) junction, single (single T) equal or unequal complete all as specified and directed by Engineer-in-Charge.
67M&L for bands, straps, supports or stays for rainwater, Ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and lintle hanges, large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters ; knee piece inserts; two way and three ways straps , plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
68M&L for 75 mm thick PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in plinth protection, finished fair and even complete all as specified and directed by Engineer-in-charge.Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. Cost of ceiling compund is included in the unit rate of this item complete all as spcified and directed.
69M&L hard core of guage not exc. 63mm deposited spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken bricks complete all as specified and directed.
70M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed by Engineer-in-Charge.
71M&L for cement concrete (1:2:4) type B2 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railigs upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, sligtly rounded or chamfered angles and throating, as directed including necessary form work complete all as specified and directed.
72M&L for PCC type C1 1:3:6 (20 mm grade aggregate) in Copings complete all as specified & directed.
73M&L for cement concrete (1:3:6) type C-1, using 20 mm graded stone aggregate as in surface channels or drain complete all as specified and directed.
74M&L cement concrete 1:3:6 mix type C2 (using 40mm graded stone aggregate) as in bed to drain pipe including packing under and hunching against the sides of pipes after laying in trenches to required slope and tested complete all as specified for 150 mm bore pipe complete all as specified and directed by Engineer-in-Charge. Note :- Thickness of concrete bed below the barrel of pipe shall be 10 cm and width of bed shall be outer dia of pipe plus 30 cm.
75M&L for salt glazed stone ware drain pipe 150mm grade 'A' laid in trenches and jointed in CM (1:1) complete all as specified and directed.
76M&L Precast Cement Conctete 1:2:4 type B1, using 20mm graded stone aggregate as in cover slabs for man holes etc set in cement morter 1:6 including necessary form work complete all as specified and directed.
77M&L for water proofing treatment with APP modified bituminous membrane 3mm thick consisting of the following for RCC roof :-(a) Cleaning palstered roof surfaces and applying a coat of oxidised bitumen based solvented primer @ 0.3Kg /Sqm of approved make on top of dry surface of RCC roof complete all as specified and directed.(b) M&L for APP modified polymeric water proofing membrance 3mm thick weight not less than 3.0 Kg/Sqm with non woven polyster core of approved make applied by heating one surface of membrane with LPG torch with lap of 100mm and the overlap shall be sealed by flame complete all as specified and directed.
78M&L for Point wiring complete with 1.5 sqmm single core FRLSH PVC insulated cable with multi stranded copper condutor in and including PVC conduit 20mm dia and thickness not less than 1.5mm, ISI marked with all accessories for surface or concealed conduit as directed at site incl chase cutting for one light/fan point controlled by one one way switch including MS sheet sunken box concealed on wall duly painted inside and outside with one coat of red oxide primer and two coats of black bituminous paint with 3mm thick hylum brand bakelite sheet cover for fixing switches, sockets, regulators etc. alongwith 1.5 sqmm multi stranded FRLSH, PVC insulated copper cable as continuous earth connected to common earth and earth dolly including making good the disturbed surfaces complete all as specified and as directed.
79All as per serial item No. 78.00 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
80All as per serial item No. 78.00 here-in-before but for One 5 pin 5 Amp socket outlet on the same board with other switches.
81M&L for point wiring with 2.5 sqmm PVC insulated, unsheathed FRLSH multistrand copper conductor cable 1100 volts grade drawn into and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all and including conduit fittings and fixing accessories 1.2mm thick sunken anodised pressed steel terminal boxes with 3.0 mm thick hylam sheet cover for mounting switches, socket etc including 2.5 Sqmm FRLSH multistrand copper conductor cable as continuous earth wire complete for one socket 16 Amp socket outlet controlled by one switch on independent board.complete all as specified and directed.
82M & L concealed sub main wiring with 2 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same complete all as specified by Engr- in- Charge.NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
83S & F modular type 6A one way SP switch 1 module confirming to IS: 3854-1997 with finger proof terminal complete all as specified and directed.
84S & F modular type 2/3 pin 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.
85S & F modular type 16 A one way SP switch 1 module confirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed.
86S & F modular type 2/3 pin 16 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.
87S&F modular lamp lamp holder insulated body with back plate batten/angle type fitting complete all as specified and directed.
88S&F LED bulb of capacity 10/12 watts not less than 700 lumens output at 6500K colour temp, complete all as specified and directed.
89S&F ceiling rose 63x30 mm three terminal, polycorbonate body complete all as specified and directed.
90S&F LED (1.2m) smartbrite extra batten made of CRCA sheet housing provided for efficient heat dissipation with a PC glossy diffuser duly prewired connection having a normal system lumen output of 2000 lumen/20 watt at a minimum system efficacy of 2000 lumen per 20 watt and total power consumption not more than 20 watt including driver of capacity 10 KA. It has a rated system life time of 25000 burning hours at L70 and should have a colour temperature of 6500 K, CRI>80, THD<10\\"%\\" AND PF>0.95 complete all as specified and directed.
91S&F LED (0.6m) smartbrite extra batten made of CRCA sheet housing provided for efficient heat dissipation with a PC glossy diffuser duly prewired connection having a normal system lumen output of 1150 lumen/10 watt at a minimum system efficacy of 1150 lumen per 10 watt and total power consumption not more than 10 watt including driver of capacity 5 KA. It has a rated system life time of 25000 burning hours at L70 and should have a colour temperature of 6500 K, CRI>80, THD<10\\"%\\" AND PF>0.95 complete all as specified and directed.
92Supply & fixing security light with LED street light, 35 Watt, IP - 66, Impact resistance - IK07, colour temp- 5700 K, Class-I in pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness, excellent corrosion resistant, separate optical and control gear compartment & top opening for easy maintenance. Polyster powder coated grey after phosphochromate treatment High efficiency long life LED modules with SMD LED package mounted on MCPCB. Lumen efficacy of LED >110 lm/W with PC lens to ensure better uniformity of light distribution. Powered by Built-in, Potted electronic LED driver (SMPS based constant current supply) with lower THD, Output Open Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection upto 10 kV with external SPD & other safety tests as per IS 15885 Part-2/ Sec13 alongwith arm with single arm bracket OD 58 mm (max) with clamp, nut, bolts etc mounted on wall complete in all respect complete all as specified and directed.
93Supply & fixing sheet metal enclosure MCB distribution board single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
94Supply & fixing of MCB single pole 240 volt any rating from 6 to 32 amps, C series with rupturing capacity 10 KA complete all as specified and directed.
95Supply & fixing of MCB Single Pole Neutral 240 volt any rating from 32 to 63 amps, C series with rupturing capacity 10 KA complete all as specified and directed.
96S&F Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230 V, 5 Hz, RPM 1200, copper winding of sweep 300mm complete all as specified and directed.
97M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt, connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI pipe 20mm light grade for water filling including 15x20mm reducer socket funnel wire mesh, RCC cover with concrete 1:2:4 using 8 mm# bar@100 mm c/c both ways ,PCC chamber pit with PCC (1:3:6) type C-2 and excavation and earth work,disposal of suplus spoil to a dstance not exceeding 50mtrs all as specified and shown on electrical plate No. 3 of 2009 (Part-I) complete all as specified and directed. Note :- The unit rate includes for protection pipe and GI wire 4mm dia from top of earth plate up to 7.5 meter above ground level.
98S&F 20mm gun metal globe or gate valve conforming to IS : 778 ISI marked with iron wheel head screwed both ends for iron pipe including GI fitting socket, nipple, unions as well cutting of pipe and necessary earth work complete all as specified and directed.
99S&F Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe 20mm bore or brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
100M&L for sand cushioning and covering clean and dry sand to underground electric cable in trenches / floor complete all as specified and directed.Note :- Punned thickness shall be measured and paid for.
101M&L for sub class 'B' brick laid dry, flat with width equal to length of brick as cover laid over the cabel to give mechanical protection to underground cabels complete all as specified and directed. Please Enable Macros to View BoQ information
102M&L for sub class 'B' brick laid dry, flat with width equal to length of brick as cover laid over the cabel to give mechanical protection to underground cabels complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58633239
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 26.23 Lakhs
LAST DATE 11-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Toilet Blocks For Central Library Bldg Under Ge (West) Mathura
Basic Detail
Tender No 8300/1436/E8
Bidding Type Tender
Location
City Mathura
State Uttar Pradesh
Key Dates
Publish Date 20 Nov 2026
Submission Date 11 Dec 2026
Open Date 18 Dec 2026
Finance
Tender Value 26.23 Lakhs
Tender Fee 500
EMD 52465
Exemption Available
Document List
6daeffbe-9d66-4e6c-bf91-270976d4a113.html
BOQ_897117.xls
Tender1436.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Dec 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
html

6daeffbe-9d66-4e6c-bf91-270976d4a113.html

xls

BOQ_897117.xls

pdf

Tender1436.pdf

pdf

Tendernotice_1.pdf

Disclaimer