Tender For Repair / Maintenance Of Earthing, Lightening Arrester And Allied Items Under Ge (W) Mathura
Tender Value
45 Lakhs
Estimated cost
Bid Submission
11 Dec 2026
19 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mathura → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance Of Earthing, Lightening Arrester And Allied Items Under Ge (W) Mathura
BOQ
| Sl. No. | Item Description |
| 1 | Taking out old unserviceable earthing pit of any type soil in any depth complete with connected accessories including necessary excavation, dismantling, breaking PCC chamber, removing old earth electrode, strip/wire of any type/size and returning refilling of excavated soil at working site complete all as specified and directed. |
| 2 | M&L for earthing complete with galvanised steel earth plate 600 mm x 600 mm x6.3 mm thick elecrode and 4 mm dia galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust of minmum qty - 40 Kg and common salt of minmum qty - 40 Kg to a packed thickness of 15 cm on all sides of electrode as specified and connected to GI wire of dia 4 mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, Cont/- |
| 3 | Cont/-- returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, precast RCC 1:2:4 type B1 cover slab 54cm x 54cm x 5cm reinforced with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 20mm GI tubing medium grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. |
| 4 | M&L for earthing complete with galvanised steel earth plate 600 mm x 600 mm x 6.3 mm thick elecrode and 32 mm x 6 mm galvanised iron strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust of minmum qty - 40 Kg and common salt of minmum qty - 40 Kg to a packed thickness of 150 mm on all sides of electrode as specified and connected to GI strip 32 mm x 6 mm as earth lead by means of bolts, nuts, check nuts and Cont/- |
| 5 | Cont/-washers (including welding) of galvanised iron or steel and connected to main switch board / LT panel/ test point/equipment at the other including necessary excavation of earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type B1 cover slab 54 cm x 54 cm x 5 cm reinforced with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20 mm bore GI tubing medium grade for watering and 40 mm GI tubing medium grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. |
| 6 | M&L for earthing complete with pure copper earth plate 600 mm x 600 mm x 3.15 mm thick elecrode and 25 mm x 4 mm pure copper strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust of minmum qty - 40 Kg and common salt of minmum qty - 40 Kg to a packed thickness of 15 cm on all sides of electrode as specified and connected to copper strip 25 mm x 4 mm as earth lead by means of tinned copper/ brass bolts, nuts, check nuts and washers (including brazing) and connected to mainCont/- |
| 7 | Cont/-switch board / LT panel/ test point/sensitive equipment at the other including necessary excavation of earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type B1 cover slab 54 cm x 54 cm x 5 cm reinforced with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20 mm bore GI tubing medium grade for watering and 40 mm GI tubing medium grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. |
| 8 | Note for serial Item No 2.00 to 4.00 :(i) If the desired resistance as specified is not achieved after the execution, the renewal of whole process will have to be done without any extra cost to the department. (ii) GI wire/GI strip/copper strip upto 7.5 metre is included in unit rate quoted by the contractor. |
| 9 | M&L for dismantling tilted / broken PCC earth pit chamber and making new PCC earth pit chamber of size as per electrical plate No. 3 of SSR-2009 Part-I with PCC (1:2:4) type B1 with pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforced with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel including excavation and earth work as required at site complete all as specified and directed. |
| 10 | Supply and fixing GI tubing 40 mm bore (Light grade) in trenches / floor / roof / wall with proper size of clamp, nuts and bolts for earth strip protection/ lightning conductors/ arrestor complete all as specified and directed. |
| 11 | Supply and fixing GI tubing 20 mm bore (Light grade) in trenches / floor / roof / wall with proper size of clamp, nuts and bolts for earth strip protection/ lightning conductors/ arrestor complete all as specified and directed. |
| 12 | S&F in replacement galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings for protection of UG cable complete all as specified and as directed by Engineer-in-charge. |
| 13 | M&L for recharging of earthing pits by filling of charcoal in earthing pits complete all as specified and directed by Engr-in-Charge.Note:- (i) Recharging shall be carried out at site on requirement basis as per direction of Engr-in-Charge.(ii) Excavation work required at site will be measured and paid separately.(iii) Measurement of earth resistance will be mandatory before & after execution of work in presence of MES rep and test report will have to be produced before renewal.(iv) If the desired resistance as specified is not achieved after the execution, the renewal of whole process will have to be done without any extra cost to the department. |
| 14 | Supply and fixing in replacement of GI strip with galvanised iron strip 32mm x 6mm with fixing screws for conductors/earth lead including welding and nut bolts jointing at all joints for building/ equipment laid through pipe/ trench/ surface or recessed or burried in ground complete all as specified and directed. |
| 15 | Supply and fixing in replacement of GI strip 25 mm x 4 mm with fixing screws for conductors/ earth lead including brazing and tinned copper nut bolts jointing at all joints for building/ equipment laid through pipe/ trench/ surface or recessed or burried in ground complete all as specified and directed. |
| 16 | Supply and fixing in replacement of copper strip 25 mm x 4 mm with fixing screws for conductors/ earth lead including brazing and tinned copper nut bolts jointing at all joints for building/ equipment laid through pipe/ trench/ surface or recessed or burried in ground complete all as specified and directed. |
| 17 | Supply and fixing in replacement of GI Wire with 4 mm dia GI or steel wire for earth continuity conductor or main earthing lead fixed to wall or recessed or buried in ground or drawn in conduit/pipe all as required at site all as specified and directed. |
| 18 | Taking out of old air termination rod of any type and any size from building / hanger of any height including dismantling and removing (except serviceable strips for re-fixing) materials from work site complete all as specified and directed. |
| 19 | Supply and fixing air termination single pointed, aluminium rod 15 mm dia and 300 mm long fixed on galvanised iron pipes with copper / aluminium / GI strip for earth conductivity to ground for building / hanger of any height complete all as specified and directed. Note: Pipe/ PCC work shall be measured and paid seperately. |
| 20 | Supply and fixing air termination single pointed, copper rod 15 mm dia,300 mm long alongwith copper air base terminal to support air rods on flat roof surfaces and to accommodate conductor on galvanised iron pipes with copper/ GI strip and make positive continuity to earthing conductor to ground for building / hanger of any height complete all as specified and directed. (Note: Pipe /PCC work shall be measured and paid seperately). |
| 21 | Taking out of old air termination rod of any type and any size from RCC overhead tank of any height including dismantling and removing (except serviceable strips for re-fixing) materials from work site complete all as specified and directed. |
| 22 | Supply and fixing air termination single pointed, aluminium rod 15 mm dia and 300 mm long fixed on galvanised iron pipes with copper / aluminium / GI strip for earth conductivity to ground for RCC overhead tank of any height complete all as specified and directed. Note: Pipe/ PCC work shall be measured and paid seperately. |
| 23 | Cutting & Chasing required on concrete block/path tile /floor etc not exceeding 20 cm girth to conceal the GI Pipe/GI Strip/ copper strip/ GI wire and making good to disturbed surface with cement mortar 1:3 including facing / finishing where as required to match with existing surfaces complete all as specified and directed. |
| 24 | M&L for checking and measurement of resistance of existing earthing at various locations by using a calibrated earth resistance tester, recording of all measured values location-wise with the help of skilled electrician and helper including tools & plants and necessary accessories and preparation the record of earthing measurement register for future reference, complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 11, 2026
17:00 IST