Tender For Provision Of Ac Unit Arrangements To The Prem Block In Government Dharmapuri Medical College & Hospital At Dharamapuri In Dharmapuri District.
Tender Value
2.14 Lakhs
Estimated cost
Bid Submission
07 Dec 2026
15 days left
EMD
2145
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dharmapuri → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Ac Unit Arrangements To The Prem Block In Government Dharmapuri Medical College & Hospital At Dharamapuri In Dharmapuri District.
BOQ
| Sl. No. | Item Description |
| 1 | Supply and fixing of hylem sheet 15\\"x10\\" covered of existing switch box and module surface mounting switch box with module cover plate on wall with all swich socket connections complete. |
| 2 | Supply and fixing of 3Nos.5A (3 pin and 2 pin) combined flush type wall socket with control switches concealed insuitable TW box covered with hylem sheet in flush with wall with earth connection (for computer plug socket). |
| 3 | Renewal by Supply, Erection, testing and Commissioning of 2TR (6000K cal / hr) ABS plastic split type Air conditioner confirming to IS 1391 [part 2] 1992 with Rotary compressor operating on refrigerant R-32/Non CFL suitable for wall mounting for operation on 230V, 50 HZ single phase AC Renewal by supply with Five Star rating as per BEE Specification and capable of performing the following functions.(A) Cooling (B) Dehumidifying (C) Air Circulating. (D)Filtering.The installation work for the above split type AC units includes the following.1. Mounting / fixing indoor and outdoor units at their respective locations.2. Laying refrigerent pipe line of 6mtrs. distance, both units after drilling hole / holes in the wall if required. Thickness of the copper tubing shall not be less than 0.7mm.3. Installing the suction pipe with expanded polythene foam 5mm thick tubing.4. Laying 15mm dia flexible PVC drain pipe of 6mts. Length to throw out the condensate water being formed in the indoor unit.5. Leakage testing the entire gas unit.6. Charging refrigerant gas in the unit.7. Suitable electric wiring to be provided with 2.5 sqmm PVC insulated copper wire between indoor and outdoor units up to 4mtr. length and up to switch within the 3 mtrs. of location of indoor unit. (Make - Carrier / Voltas / Blue Star make only). |
| 4 | Supply and installation of 5KVA capacity Automatic Voltage Stabilizer with time delay relay. |
| 5 | Supply and laying of 5/8\\" and 3/8\\" copper pipe (Extra beyond 3 metres supplied with AC unit). |
| 6 | Supply and fixing of MS stand for fixing outdoor unit. |
| 7 | Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour. |
| 8 | Supply and Run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour. |
| 9 | GST@18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysDec 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender