Housing Urban and Rular Development Government Departments Closing in 13 days TDR #58629800

Tender For Expression Of Interest (Eoi) For Empanelment Of Consultancy Firms For detail project report Preparation, Design Review / Proof Checking And Allied Services For Roads, Buildings, Water Supply And Sewerage Work In The Ut Of Dadra And Nagar H

Issued by Government Departments · Daman, Daman and Diu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
05 Dec 2026
13 days left
EMD
2 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Daman → Daman and Diu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Expression Of Interest (Eoi) For Empanelment Of Consultancy Firms For detail project report Preparation, Design Review / Proof Checking And Allied Services For Roads, Buildings, Water Supply And Sewerage Work In The Ut Of Dadra And Nagar Haveli And Daman And Diu

BOQ

Name of Work:- Expression of Interest (EOI) for empanelment of consultancy firms for DPR preparation, design review / proof checking and allied services for roads, buildings, water supply and sewerage work in the UT of Dadra and Nagar Haveli and Daman and Diu
Sl. No. Item Description
1Consultancy services.
2Topographic and Contour Survey work with level at every 10m interval up to ROW
3(a) For ROW of 60 meter
4(b) For ROW of 40 meter
5(c) For ROW 25 meter
6(C) For ROW of up to 18 meter
7Collection of Subgrade soil sample and Necessary Laboratory Investigation
8Conducting BBD test, Condition survey and condition survey on existing pavement including truck rent
9Conducting FWD test, Condition survey and condition survey on existing pavement
10Pavement design for the Overlay & widening
11Geometric Design (Horizontal and Vertical alignment) and Junction improvement with shyness and Road Marking/Furniture as per the IRC Guide lines with Typical cross section of the road
12Bill of Quantities and Cost estimate for Road work
13Pipe Culvert design and Drawing (New / Widening) including Inventory
14Box slab Culvert design and Drawing (New / Widening) including Inventory
15Major bridge design and Drawing (New / Widening) including Inventory
16Minor bridge design and Drawing (New/Widening) including Inventory
17Preparation of BOQ for the Cross-drainage work like Major bridge, Minor bridge, Box culvert, Pipe culvert
18(a) Major Bridge
19(b) Minor bridge
20( c) Box/slab Culvert
21(d) Pipe culvert
22Tender Preparation include RFP, NIT and Technical Specification
23Conducting traffic Survey
24Conducting Axle load
25Origin-Destination and Commodity Movements Surveys
26Turning Movement Surveys
27Speed-Delay Surveys
28Pedestrian Surveys
29Traffic Demand Estimates
30Mapping of heritage structure
31Drainage System Design
32Road furniture plan
33Parking Areas and Rest Areas
34Project Reports
35Geo technical Investigation forp proposed structures including Drilling of boreholes,Collection of Disturbed and Undisturbed samples,Conducting SPT,Carrying out necessary
36(a) For Soil
37(b) For Soft Rock
38(C) For Hard Rock
39Land Acquisition Plan
40Conducting FWD test on Existing road surface
41Conducting NSV test on existing road surface
42Pond Design and Estimate
43Rebound Hammer Test: Preparing the surface of RCC structural members such as beams, columns, slabs etc by chipping the plastered surface/finishing /cladding to expose the concrete, smoothening the area using carborandum stone all in terms of relevant IS code and conducting rebound hammer test all as per IS 13311-1992 (Part 2) or as directed by consultant including analysis of the test result & preparation of separate report for each building with observations and recommendations for remedial measures if any.
44UPV ( Ultrasonic Pulse Velocity) Test: Preparing the surface of RCC structural members such as beams, columns, slabs etc. by chipping the plastered surface/ finishing/cladding to expose the concrete,smoothening the area using carborandum stone all in terms of relevant IS code and conducting ultrasonic pulse velocity test all as per IS 13311-1992 (Part 1) or as directed by consultant including analysis of the test result & preparation of separate report for each building with observations and recommendations for remedial measures if any.
45Half Cell Potential Test for Corrosion mapping. Preparing the structural members as directed to expose the reinforcement steel, cleaning the area with blower/wire brush and carrying out half-cell potentiometer test for measuring the level of corrosion of reinforcement steel in the RCC member including analysis of the test result & preparation of separate report for each building with observations and recommendations for remedial measures if any.
46Carbonation Depth Test: Preparing the surface of RCC structural member such as beams, columns, slabs, water tank walls & slab etc by chipping the plastered surface/finishing/cladding to expose the concrete, cutting etc as per relevant code and conducting carbonation test at various depth as directed by consultant using phenolphthalein of specified concentration to assess depth of carbonation including separate report for each building with analysis of the test result, observations and recommendations for remedial measures if any.
47Concrete Core Extraction and Testing: To carry out Concrete Core Extraction and testing of concrete cores from RCC structural members as per IS 516 / IS 1199 / IS 456, including making good the cored hole, analysis of the test result and preparation of separate report for each building with observations and recommendations for remedial measures if any.
48Cover meter survey with report (as in the earlier schedule of this RFP)
49Preliminary inspection of all the exposed components of the building, Preliminary Inspection Report and important observations shall be considered in the preliminary inspection report. For upto 400 sqmt built up area of particular building
50Preliminary inspection of all the exposed components of the building, Preliminary Inspection Report and important observations shall be considered in the preliminary inspection report. From 401 to 2000 sqmt built up area of particular building
51Preliminary inspection of all the exposed components of the building, Preliminary Inspection Report and important observations shall be considered in the preliminary inspection report. From 2001 to 5000 sqmt built up area of particular building
52Preliminary inspection of all the exposed components of the building, Preliminary Inspection Report and important observations shall be considered in the preliminary inspection report. Above 5001 sqmt built up area of particular building
53Consultancy charges for preparation of building wise structural audit report which includes The findings from detailed visual inspection ,Non-destructive test results, Suggested remedial measures, Bill of quantities item wise & detailed specification with cost estimate for each building, Classification of severity, Photos of distressed location, including inspection of rectification of short comings for all the premises pointed out during the execution and subsequent inspection and provision, required certification of stability of building as directed by Engineer In Charge. For upto 400 sqmt built up area of particular building
54Consultancy charges for preparation of building wise structural audit report which includes The findings from detailed visual inspection ,Non-destructive test results, Suggested remedial measures, Bill of quantities item wise & detailed specification with cost estimate for each building, Classification of severity, Photos of distressed location, including inspection of rectification of short comings for all the premises pointed out during the execution and subsequent inspection and provision, required certification of stability of building as directed by Engineer In Charge. From 401 to 2000 sqmt built up area of particular building
55Consultancy charges for preparation of building wise structural audit report which includes The findings from detailed visual inspection ,Non-destructive test results, Suggested remedial measures, Bill of quantities item wise & detailed specification with cost estimate for each building, Classification of severity, Photos of distressed location, including inspection of rectification of short comings for all the premises pointed out during the execution and subsequent inspection and provision, required certification of stability of building as directed by Engineer In Charge. From 2001 to 5000 sqmt built up area of particular building
56Consultancy charges for preparation of building wise structural audit report which includes The findings from detailed visual inspection ,Non-destructive test results, Suggested remedial measures, Bill of quantities item wise & detailed specification with cost estimate for each building, Classification of severity, Photos of distressed location, including inspection of rectification of short comings for all the premises pointed out during the execution and subsequent inspection and provision, required certification of stability of building as directed by Engineer In Charge. Above 5001 sqmt built up area of particular building
57Measured survey and drawings of existing building
58Architectural design and drawings of building
59Structural design and drawings of building (RCC / steel) with foundation
60Electrical design and drawings of building
61Plumbing, drainage and fire-fighting design and drawings
62HVAC and lift design and specifications
63Design of retrofitting / rehabilitation of existing building
64Preliminary estimate on CPWD Plinth Area Rates
65Detailed estimate and BOQ of building works on CPWD DSR with cost index
66Tender preparation of building works, including RFP, NIT and technical specifications
67Preparation of Detailed Project Report of building works
68Asset inventory and GIS mapping of water supply system
69Pipeline route and levelling survey with plan and longitudinal section
70Condition assessment of sump / reservoir
71Condition assessment of elevated service reservoir with NDT
72Condition assessment of water treatment plant
73Pressure, flow and leakage test of distribution network
74Pump performance test
75Water quality sampling and testing (IS 10500)
76Non-revenue water study and water audit
77Population forecast and water demand projection
78Hydraulic modelling and design of distribution network
79Design of intake and raw water main
80Process, hydraulic, structural and mechanical design of water treatment plant
81Structural design of ESR / ground level reservoir / sump (IS 3370)
82Design of pumping station with pump selection and surge analysis
83Design for rehabilitation of existing pipes and structures
84BOQ and estimate of water supply works
85Tender preparation of water supply works, including RFP, NIT and technical specifications
86Preparation of Detailed Project Report of water supply scheme
87Asset inventory and GIS mapping of sewerage system
88Route and topographic survey with plan and longitudinal section
89Manhole and invert level survey
90Flow measurement
91Sewage sampling and testing
92CCTV inspection of sewer with condition report
93Catchment study, population forecast and sewage generation
94Hydraulic modelling and design of sewer network with manholes
95Design of house sewer connections
96Design of sewage pumping station and rising main
97Process, hydraulic, structural and mechanical design of sewage treatment plant
98Design of decentralised treatment and faecal sludge and septage management
99Design for rehabilitation of existing sewers
100BOQ and estimate of sewerage works
101Tender preparation of sewerage works, including RFP, NIT and technical specifications
102Preparation of Detailed Project Report of sewerage scheme
103Proof checking of building design, drawings and BOQ
104Proof checking of bridge: (a) major bridge, (b) minor bridge
105Proof checking of road design, drawings and BOQ
106Proof checking of pipe culvert
107Proof checking of box / slab culvert
108Proof checking of retaining wall
109Proof checking of gabion wall
110Proof checking of gabion facia wall
111Geotechnical investigation for building / plant site: boring, field and laboratory tests with report
112Topographic survey of building / plant / reservoir site
113Preparation of GIS database and maps
114Environmental and social impact assessment and clearance documents
115Value engineering of a design or estimate
116Third-party technical audit of works with testing of materials and workmanship
117Advisory report on a technical issue referred by the Client
118Tender preparation of combined packages of more than one discipline, including RFP, NIT, technical specifications and BOQ
119Tender support: pre-bid queries and bid evaluation
120Execution support: shop drawing review
121Execution support: site inspection visit with report
122Verification of as-built drawings Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58629800
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 05-12-2026
Authority
Authority Name Public Works Department
Work Description Tender for Expression Of Interest (Eoi) For Empanelment Of Consultancy Firms For detail project report Preparation, Design Review / Proof Checking And Allied Services For Roads, Buildings, Water Supply And Sewerage Work In The Ut Of Dadra And Nagar Haveli And Daman And Diu
Basic Detail
Tender No Tender Notice No.105/RFP EOI/2026-27
Bidding Type Tender
Location
City Daman
State Daman and Diu
Key Dates
Publish Date 19 Nov 2026
Submission Date 05 Dec 2026
Open Date 05 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee 10000
EMD 2 Lakhs
Exemption Not Available
Document List
8fa82e5d-e084-46bc-9143-c83003b27dca.html
BOQ_5239.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Dec 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

8fa82e5d-e084-46bc-9143-c83003b27dca.html

xls

BOQ_5239.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender