Health and Family Welfare Government Departments Closing in 13 days TDR #58629691

Tender For Construction Of Additional Floor Over Existing Ground Floor Including Addition / Alteration And Modification Of Existing Ground Floor At Sports Complex, Sector-7, Chandigarh-Supplying, Installation, Testing And Commissioning Of Machinery F

Issued by Government Departments · Chandigarh, Chandigarh
Tender Value
24.70 Lakhs
Estimated cost
Bid Submission
04 Dec 2026
13 days left
EMD
49401
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Additional Floor Over Existing Ground Floor Including Addition / Alteration And Modification Of Existing Ground Floor At Sports Complex, Sector-7, Chandigarh-Supplying, Installation, Testing And Commissioning Of Machinery For Fire Fighting System And Allied Items Including Piping And Valves

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 20-Nov-2026 Make list corrigendum Technical Bid 04-Dec-2026

BOQ

Name of Work:- Construction of Additional Floor over existing Ground Floor including Addition / Alteration and Modification of existing Ground Floor at Sports Complex, Sector-7, Chandigarh-Supplying, Installation, Testing and Commissioning of Machinery for Fire Fighting System and allied items including Piping and Valves
Sl. No. Item Description
1Supplying, installation, testing and commissioning of Electric driven Main Fire Pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in allrespects, as required :(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018.(d) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(e)Suitable cement concrete foundation duly plastered with anti vibration pads. .27.1
21620 lpm at 56 m Head .27.1.9
3(a) Supplying, installation, testing andcommissioning of diesel engine driven main fire pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel DrivenPump)(b) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted .27.2
4with post office red colour etc. as required.(d) M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) Suitable cement concrete foundation duly plastered and with anti vibration pads. .
51620 lpm at 56 m Head .27.2.9
6(a) Supplying, installation, testing andcommissioning of electric driven pressurisation pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (JockeyPump)(b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class- 'F' insulation, conforming to IS-12615: 2018.(d) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) Suitable cement concrete foundation duly plastered and with anti vibration pads. .27.3
7180 lpm at 56 m Head .27.3.3
8E & M ( As per Drawing ) .
9Fabrication, supplying, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised withhinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required .27.5
10INCOMING250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich &CTs etc.LED type RYB phase indicating lamps, ON, OFF, trip indicating lampsSet of Copper Bus Bar 300AOUTGOING( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LEDtype ON, OFF, trip indicating lamps)Main Fire Pump 125 A, 50kA TPN MCCB, Ics=100% Icu, with fullyautomatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/ remote, auto/manual/OFF operation. .27.5.1
11Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overloadprotection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Diesel Engine ControlControl for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual modeIndicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC AmmeterAll standard relays and accessories for automatic operation of diesel engine System Controller .
12Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification .
13Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/Class -II of IS: 3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. .27.6
14150 mm dia .27.6.2
15Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : .27.7
1680 mm dia .27.7.6
17200 mm dia (wall thickness 6.3 mm) .27.7.9
18Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required .27.9
19Single headed Stainless steel .27.9.2
20Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : .27.11
2180 mm dia .27.11.4
22150 mm dia .27.11.6
23200 mm dia .27.11.7
24Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : .27.16
25Stainless Steel (Grade 304) .27.16.2
26Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. .27.17
2720 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 .
2820 mm nominal internal dia gun metal globe valve & nozzle. .
29Drum and brackets for fixing the equipmets on wall. .
30Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. .
3130 mtr .27.17.1
32Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: .27.18
33Stainless Steel (Grade 304) .27.18.2
34Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: .27.19
354 way - 150 mm dia M.S. Pipe .27.19.2
36Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. .27.22
37Providing and fixing of LT Power / Control Cable - Copper , XLPE Insulated, Un-armoured ,IS 7098 Part 1 marked approved make complete with making connections. .NSR
383 core x 4.0 Sqmm .
393 core x 10.00 sqmm .
40Providing and fixing dial type pressure gauge with isolation cock and copper pipe at hydrant station. .NSR
41Supplying & Installation of Dual Plate Non Return Valve with PN Rating 1.6 of approved make complete. .NSR
4280 mm dia .
43150 mm dia .
44Manufacturing, Supplying and fixing of Mild Steel Sheet Hose Cabinet for RRL Hose & Branch Pipe, Double Door cabinet with locking arrangement, including Glass window with rubber gasket, duly painted with post office Red color complete to the satisfaction of EIC .NSR
45Providing and Fixing of ABC (Power type) ABC FIRE EXTINGUISHER/ 4 kg HP Mild Steel Cylinders ISI marked approved fitted with pressure indicating gauge capacity complete with discharge horn and mounting it on the wall with a suitable MS bracket (including S/F bracket) minor civil works etc. complete as required of approved make .NSR
46Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5 kg. ISI Marked.( Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.) .NSR Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58629691
AUTHORITY Government Departments
TENDER VALUE 24.70 Lakhs
LAST DATE 04-12-2026
Authority
Authority Name Public Health Department.
Work Description Tender for Construction Of Additional Floor Over Existing Ground Floor Including Addition / Alteration And Modification Of Existing Ground Floor At Sports Complex, Sector-7, Chandigarh-Supplying, Installation, Testing And Commissioning Of Machinery For Fire Fighting System And Allied Items Including Piping And Valves
Basic Detail
Tender No PH3/2026/559
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 20 Nov 2026
Submission Date 04 Dec 2026
Open Date 01 Jan 0001
Finance
Tender Value 24.70 Lakhs
Tender Fee Ref. Documents
EMD 49401
Exemption Not Available
Document List
b29815d7-57d5-4fbe-852f-d821cc1483a9.html
BOQ_119409.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 04, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 13 days
Dec 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

b29815d7-57d5-4fbe-852f-d821cc1483a9.html

xls

BOQ_119409.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender