Project Description
Tender for Aaugmentation And Relaying Of Cable Trays In Laundry Section Block -C, Gmch Sector-32, Chandigarh.
BOQ
| Sl. No. | Item Description |
| 1 | DSR item No.1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group-C |
| 3 | DSR item No. 1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 4 | Group-C |
| 5 | DSR 1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 6 | 8 Module (125 mm x 125 mm) |
| 7 | 12 Module (200 mm x 150 mm) |
| 8 | DSR item No.1.17 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 9 | 3 x 1.5 sq.mm |
| 10 | 3 x 2.5 sq.mm |
| 11 | DSR 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 12 | DSR item No.2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 13 | 250 A,36KA,FPMCCB |
| 14 | DSR item No.4.1 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as required. |
| 15 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 16 | DSR 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 17 | Triple pole and neutral |
| 18 | DSR item No.8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). (Please refer DNIT for complete specification of item no.9) |
| 19 | 100 Watt. |
| 20 | Supplying and fixing suitable size GI box 6 Module (200mm X75mm) in recess/surface as required with modular plate and cover, including providing and fixing 1 No. 3 pin 5/6 A & 1 No. 6 pin 15/16 A modular socket outlet and 1 No. 5/6 A & 1 No. 15/16 A modular switch. The job includes the cost of making interconnections with suitable copper wire and other petty material required to complete the job to the entire satisfaction of Engineer-in-Charge at site. The Modular accessories should be of Lauritz Knudsen (Entice) / ABB (Ivie) / Legrand (Myrius) / Crabtree (Athena)/ Norisys (Square series) make only. |
| 21 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. |
| 22 | Size 12 inch (300mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells (Turbo Force SP) / Orient (Industrial Heavy Duty)/ Usha (Turbo HDEF)/ Crompton (EXHD300-6-1)/ Bajaj (Supreme Plus) make only. |
| 23 | Supply & erection MCB 4 pole 63 Amp 415 Volt 10KA Breaking Capacity ‘C’ curve without enclosure. The job includes the labour charges and other petty material required to complete the job. The MCB should be of Lauritz Knudsen (Exora)/ Legrand (DX3)/ Hager (h3)/ Schneider (Acti9)/ ABB (SB200M)/ Siemens (Betagard) make only. |
| 24 | Fabrication, supplying, installation, testing and commissioning of Indoor type cubicle type fully enclosed compartmentalized electric panel of suitable size (300mm-900mm) deep as required as site suitable for three phase 50 Hz 415 volt AC supply system made out of 1.6 mm thick CRCA sheet duly strong thread with suitable size of MS channel members and base weather proof dust and vermin proof, ventilated with louvers at sides removable gland plates at the bottom, earthing studs at both ends duly painted with powder (Please refer DNIT for complete specification of item no.13) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysNov 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender