Tender For Maintenance Of Street Light, High Masts, Subways, Underdeck & Fob Lights On Delhi Pwd Roads Under Pwd Emd South West. (Sh : Replacement Of Damaged, Theft Accessories Of Feeder Panel, Accessories For Street/ High Mast Panel At Various Locat
Tender Overview
Project Description
Tender for Maintenance Of Street Light, High Masts, Subways, Underdeck & Fob Lights On Delhi Pwd Roads Under Pwd Emd South West. (Sh : Replacement Of Damaged, Theft Accessories Of Feeder Panel, Accessories For Street/ High Mast Panel At Various Location On Pwd Road Under Sub Division Iii ).
BOQ
| Sl. No. | Item Description |
| 1 | Providing & Fixing of following electrical accessories/switches etc in existing panel board including making connection testing, commissioning etc. complete as reqd. |
| 2 | 250 A, 35 KA,TPMCCB (Ics=Icu=100%) |
| 3 | 125 A, 16 KA,TPMCCB (Ics=Icu=100%) |
| 4 | 100 A, 16 kA,TPMCCB (Ics=Icu=100%) |
| 5 | Digital Volt Meter (0-500) with selector switch |
| 6 | Digital Ammeter (0-300) with selector switch |
| 7 | LED Indicator Lamp |
| 8 | Digital Timer |
| 9 | Power contactor 110 A |
| 10 | Fabrication, Supplying and fixing of wiremesh frame work made out of 40 mmx40mm x5mm thick Angle iron having 40x6mm flat strip & wiremesh 6 swg dia m.s wire with 25mmx75mm space in between mesh & top covered for rain protection by 16 SWG MS Sheet and making main door gate having suitable locking arrangement with godown lock (Frame size shall not be more than 60 cm x 90 cm) i/c grouting with cement concrete & primer and spray painting with super synthetic enamel paint of approved colour quality with heavy duty Godown lock etc as reqd. |
| 11 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 12 | 4 X 25 sq. mm (28mm) |
| 13 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 14 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 15 | Providing Boring (trenchless digging) in Soft Soil and Laying HDPE pipes (ISI Marked) of 120 mm O.D. confirming to IS- 4984-1995 as amended upto date with pressure rating of 4 kg/sq.c.m by trench less technology with no dig method by making bore hole in horizontal direction across the road as per direction of Engineer- in- charge with mounting equipment i/c jointing cleaning, roadding of pipe. providing suitable covers on mouth of pipes, excavation of pits of required size at a depth of 1.30 mtrs. to 2.00 mtrs. |
| 16 | Fabrication, Supplying and fixing of feeder panel / High Mast window cover made of MS Sheet of minimum 1.6 mm thick i/c cutting, welding, grinding alignement and fixing the door with heavy duty hinges, nut bolts and providing 2 coats of synthtic enemal paint after applying primer etc complete as required. |
| 17 | Supplying fabricating welding of heavy-duty, high-security godown lock system Made from robust materials with a strong zig-zag shackle design, it ensures maximum protection against tampering and forced entry in feeder panel / High Mast window cover made of G.I. Sheet of etc as required. |
| 18 | Replacement of old unserviceable of the following accessories of the existing high mast suitable for fixing luminaires and fixing with suitable size U clamp of both the ends of high mast rope i/c making connections, testing, commissioning etc. i/c complete greasing of the pinions/gear for smooth functioning of the rope, making required holes to fix the same etc complete as required. |
| 19 | Winch assembly for 30 Mtr |
| 20 | Winch assembly for 20 Mtr |
| 21 | S S Wire Rope Grade - 304 (8 MM) |
| 22 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 23 | Upto 35 sq. mm |
| 24 | Above 35 sq. mm and upto 95 sq. mm |
| 25 | Cutting of hard rock/road/ PCC/Paver Block for laying of UG cable for Street light pole to pole with the help of hilty/ hammer etc. i/c making good by laying in position cement concrete 1:2:4: (1 Cement :2 coars sand : 4 graded stone ) of size 0.2 B x 0.2 D mtr etc. as required. |
| 26 | Supplying of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 27 | 100 watt |
| 28 | Supplying of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K+ / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 29 | 150 watt |
| 30 | Fabrication, Designing, Supplying & Fixing of Galvanized arm street light pole bracket / High Mast Ring (single/double/tripple/Ring over hang/) with tightening bolt etc. (due to accident of poles) as per existing design of brackets of roads where the street light pole bracket to be fixed or as per approved by Engineer-In-Charge. (Similiar type as per existing pole) |
| 31 | Installation of LED Flood light fittings on the existing upto 30/20 Mtr High Mast lantern carriage by suitable means i/c making connection with suitable size copper connecting wire and fixing with thimble / ferrul and testing, commissioning etc complete as required. |
| 32 | Supplying & fixing PVC insulated PVC sheathed copper conductor flat cable ISI Marked in existing metal/ HDPE / PVC/ pipe including fixing the cable to GI/HDPE pipe with suitable cable tags of following sizes etc. as required. |
| 33 | 5 Core 6 Sq mm Flat Cable |
| 34 | Welding of existing GI street light pole covers and LT panel doors with single joint, including cutting, fitting and welding with suitable welding electrodes using welding machine, wherever required, complete in all respects, to prevent unauthorized opening and theft of electrical wires, cables, accessories and other electrical components, |
| 35 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching and re-filling etc as required |
| 36 | 40 mm |
| 37 | Credit for old unserviceable and dismantle material |
| 38 | Wire Rope |
| 39 | Assorted size Aluminium Cable |
| 40 | Assorted size feeder size feeder pillar panel with accessories |
| 41 | Assorted size LED fittings |
| 42 | Wich assembly Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender