Tender For Special Repair For Otm Accn Bldg No P-122 Of 29 Ad Regt At Mil Stn Bhuj Under Ge (A) Bhuj.
Tender Value
38.79 Lakhs
Estimated cost
Bid Submission
11 Dec 2026
20 days left
EMD
77580
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kachchh → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair For Otm Accn Bldg No P-122 Of 29 Ad Regt At Mil Stn Bhuj Under Ge (A) Bhuj.
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed. |
| 2 | M&L for machine cut kota stone slab flooring 18-20 mm (+ 2mm) thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and as directed. |
| 3 | M&L for mirror polished machine cut Kota stone slab 15-16 mm thick in riser of steps, skirting, dado and pillar laid over and including 10mm thick rendering in CM 1:4 and jointed complete all as specified and as directed. |
| 4 | M&L for light shade Virified Ceramic tiles 7 to 8mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including screed bed 15mm thick in CM 1:6 complete all as specified and directed. |
| 5 | M&L for light shade Virified Ceramic tiles 7 to 8mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm in vertical surfaces includig 10 mm thick rendering in CM 1:3 complete all as specified & directed. |
| 6 | M&L Coloured Glazed Ceramic tiles (Digital Designer tiles) 300 x 450 and 6-7mm thick on vertical surfaces such as skirting, dados and risers to steps etc including 10mm thick backing coat in CM 1:4 with all possible design combination complete all as specified and directed. |
| 7 | M&L non skid ceramic tiles(Coloured) 7 to 8mm thick (square/rectangular) area of each tile exc 0.06sqm but n.exc 0.11 sqm, in in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including screed bed 15mm thick in CM 1:6 complete all as specified and directed. |
| 8 | M&L for 18-20mm thick Granite (of any type) (Jet black) work (table rubbed and polished) in cooking platform, Jambs cill and like set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match shade of granite including rounding of exposed edges of slab smoothly and polished complete all as specified and directed. |
| 9 | Demolition of precast concrete block walling and similar items i.e.. ashlar facing dressed stone work, precast concrete articles etc., of any description and in any position, built in cement mortar, including all quoins, arches and pillars etc. complete all as specified and directed. |
| 10 | M&L for precast cement concrete block masonry with solid blocks of PCC (1:3:6) type C-1 (using 20mm and 12.5 mm graded stone aggregate in the proportion as directed) exc 10cm in width and set and jointed in Cement Mortar (1:6) complete all as specified and directed. |
| 11 | Taking down carefully Cement Concrete (Reinforced) in chajjas ,staircase,landing,window sunshades and other suspended portion at any height, including cutting down of damaged or rusted reinforcements and making the surface good by rendering 10-15 mm thick of CM 1:3 or cement concrete 1:2:4 on exposed concrete and finishing the surface even and smooth including necessary formworks complete all as specified and directed. |
| 12 | Taking down carefully cement concrete/ spalled out concrete from RCC roof projections,Ceilings,Sunshades,beams etc upto cover depth by chipping out lightly including necessary scaffolding etc complete all as specified & directed. |
| 13 | M&L for cleaning the existing reinf of slabs chajjas etc & applying a coat of SIKA RUSTOFF 11 or equivalent of pidilite,fosroc,Thermax etc to remove rust particles etc throughly cleaning the surface complete all as specified & directed. |
| 14 | M&L for applying a coat of bond coat made with cement slurry(1part cement to 1.5-2parts water) mixed with admixture LATEX POWER mixed @5 Kg per 50kg of cement & applying to the concrete surfaces @200gm/sqm to obtain tack complete all as specified & directed. |
| 15 | M&L for 15-20mm thick rendering in CM 1:1:2 using 1 part cement to 1part 2-3mm screenings of stone agg & 2 parts coarse sand over the bond coat applied surfeces with cement mixed SIKA PLASTOCRETE admixture equivalent of pidilite,fosroc,Thermax etc @100gm/50kg of cement & finishing the surfaces even & rough to recieve final rendering coat complete all as specified & directed. |
| 16 | M&L for 10-15mm thick rendering in CM 1:3 over the bond coat applied surfeces with cement mixed SIKA PLASTOCRETE SUPER admixture @100gm/50kg of cement & finishing the surfaces even & smooth complete all as directed at site complete all as specified & directed. |
| 17 | S&F GI chicken wire mesh of 0.71mm dia wire & 12mm mesh size fixed with nails & screws around RCC chajjas/fascias etc complete all as specified & directed. |
| 18 | Taking down cement plaster of any description and in any position of brick/concrete surfaces on walls/celling etc. including racking out joints, hacking for key, scrubbing down with water etc & prepared to receive new plaster complete all as specified and directed. |
| 19 | M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces/stone masonry and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 20 | M&L for rendering 15 mm thick in CM (1:6) on fair faces of brick work or concrete surfaces/stone masonry and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 21 | M&L for rendering 5 mm thick in Cement Mortar (1:3) on ceiling finished even and smooth without using extra cement complete all as specified and directed. |
| 22 | Material & Labour for preparation of old/new wall surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. |
| 23 | M&L for preparation of old/new plastered surfaces of wall and applying 1.5mm to 2mm thick wall putty finished to a even and smooth complete all as specifed and directed. |
| 24 | M&L for preparation of old/new plastered surfaces of wall and applying 2 coats of Oil Bound distemper finished to a even and smooth finish over a coat of alkali primer complete all as specifed directed. |
| 25 | M&L for preparation of the newly plastered surfaces of ceiling & applying 3 coats of white wash on ceiling surfaces complete all as specified and directed. |
| 26 | M&L for preparation of old decorated surface of ceiling and including cornices plastered or unplastered surfaces by brooming down or steel wire brushing to remove all loose scales, and foreign materials scarping down , smoke soot moulds , moss and efflorescent salts treating oil and greasy spots and applying one coat of white wash complete all as specified and directed. |
| 27 | M&L for preparation of new/old steel surfaces exc 10 cm width or girth and applying two coat synthetic enamel paints on new steel surfaces over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 28 | M & L applying two coats of synthetic enamel paint on new/old wooden surfaces of any description over 10 cm width or girth over including preparation of surfaces complete all as specified & directed. |
| 29 | M&L for complete removal of existing roof treatment incl brushing and applying neat cement slurry with 3 Kg/Sqm of cement complete all as specified and directed. |
| 30 | M&L for averaging 25mm thick PCC of type B-1, 1:2:4 (20mm graded stone aggregate) for padding incl water proofing compund complete all as specified and directed. |
| 31 | M&L Rendering 10 mm thick of CM 1:4 on concrete roof surfaces is to be finished even and smooth without using extra cement with mixing water proofing compound @3% by weight complete all as directed. |
| 32 | M&L for water proofing treatment to roof surfaces as under :-Surface PreparationRoof substrate must be washed with water to remove all dirt, dust, chalking and waste products.Stagnant water due to undulation in the roof surface should be marked and repaired with PMM. All joints / corners / penetration points, rainwater outlets, marble / tile strip joints should be grouted with PMM.WATERPROOFING APPLICATIONAll joints / corners / penetration points, rainwater outlets, marble / tile strip joints and parapet wall and floor junction joint (corner rounding) over the length shall be treated prior to all application of Dr. Fixit Roofseal Classic by reinforcing minimum layer of 50 – 100 mm width, with 45gsm glass fibre mesh cut to size, embedded in between the two coats of Dr. Fixit Roofseal Classic to provide additional strength to the treatment. Allow the coating to dry for 4- 6 hrs. before application of second. Apply a coat of Dr. Fixit Roofseal Classic (diluted with water in the ratio 2:1) as Self-Priming 9 - 10 Sq.mtr / litre. Allow coating to dry for 4 hours prior to applying first coat & second coat. pply two coats of Dr. Fixit Roofseal Classic @ 2.0 - 2.2 Sq.mtr / litre / coat, with the same application coverage. Application direction of second coat should be perpendicular to that of the first coat without water dilution to deliver a DFT of 450– 500 micron. |
| 33 | M&L for water proofing treatment to wall surfaces as under :-Surface PreparationSurface must be thoroughly cleaned, free of dust, grease etc and washed well with water. The surface to be checked for cracks, hollowness and loose plastered areas etc if any. All loose plaster and cracks larger than 10 mm width to be repaired with polymer modified mortar using Dr. Fixit Pidicrete URP. The cracks up to 5 mm to be treated with Dr. Fixit Crack-X Paste and the larger ones up to 10 mm with Dr. Fixit Crack-X Shrinkfree.PrimingAfter the proper surface preparation and curing of repaired areas wash the surface well and maintaining it in saturated surface dry condition proceed for priming using Dr. Fixit Primeseal diluted in 2:1 ratio with water (2 parts Primeseal diluted with 1 part water). Maintain the spreading rate of 8-10 sq mtr per litre for a single coat application to achieve about 20 – 25 microns DFT. Allow it to dry for 6-8 hrs.COATINGBrush apply one coats of Dr. Fixit Raincoat Waterproof Coating without any dilution Maintain the spreading rate of 3.5-4.0 sq mtr per litre / coat application to achieve about 120-130 microns DFT. The second coat of Dr. Fixit Raincoat Classic Topcoat to be apply with interval of 6-8 hours without any dilution. Maintain the spreading rate of 7-8 sq mtr per litre / coat application to achieve about 50-60 microns DFT. |
| 34 | Demolition of cement concrete of any description and in any position (unreinforced) in ground floors/ paving not exceeding 15 cm thick (below or above GL) complete all as specified and directed. |
| 35 | M&L for PCC (1:3:6) type C2, (using 40mm graded stone aggregate) as in plinth protection, 75 mm thick, finishing the surface even and smooth w/o using extra cement complete all as specified and directed. |
| 36 | Supply and fixing in repairs decorative type curtain rod stainless steel finish of pipe 22 to 25 mm dia as per sample approved by GE complete all as specified & directed. |
| 37 | Supply and fixing of purpose made brackets trade pattern for decorative type curtain rods suitable for holding 22 to 25 mm dia as per sample approved by GE complete all as specified & directed. |
| 38 | Supply and fixing in repair of decorative fincals (round type with mirror optic finish) trade pattern for decorative type curtain rods suitable for 22 to 25 mm dia curtain rods as per sample approved by GE's complete all as specified & directed. |
| 39 | Taking down chowkat or frames n.exc 1.5 sqm with shutters without taking off shutters from the frame and removing to store complete all as specified and directed. |
| 40 | Taking down chowkat or frames exc 1.5 sqm & n exc 4 sqm with shutters without taking off shutters from the frame and removing to store complete all as specified and directed. |
| 41 | S & F Powder coated Aluminium alloy sections sliding windows with frames Series-C (20mm) and , 3 track sliding shutters duly fitted with neoprene beading, glazing clips, shutters with tinted glass 5mm thick and stainless steel wire cloth 0.36mm dia and average width of aperture 1.4mm , aluminium alloy handles etc. complete all as specified and directed. |
| 42 | M & L powder coated aluminium deco grill medium grade of mesh size 75mmx75mm with square anodised aluminium bars fixed with aluminium frame of size 9x9 mm complete all as specified and directed. |
| 43 | S&F powder coated aluminium anodised ventilator with fixed aluminium frame of size 65 x 40 x 1.98mm thick fixed in vertical position with aluminium vertical members and half portion to be provided with 4mm thick pin head glass and remaining portion to be louvered using 4mm thick pin head glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm incl necessary channel frame work, including rubber gasket and aluminium beading complete all as specified and directed. |
| 44 | S&F 30 mm thick factory made Flush shutters , solid core construction , with block board core and plywood face panels commenrcial face on bath sides with lipping/frame to match complete all as specified and directed. |
| 45 | M & L for 30 mm thick glazed and skeleton shutters of 1st class Hard Wood(Not less than Hollock wood) local made shutter, open rebated and prepare to revive glass, gauge etc (without sash bars ) edges of framing plain chamfered or rounded, fitted with moulded beads both sides for securing glass etc, size of members of shutters as specified in SSR part I section 8 clause 8.24 (a) supplied and fitted to chowkat complete all as specified and directed. |
| 46 | S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed. |
| 47 | S&F for butt hinges 100mm size medium weight stainless steel complete all as specified and directed. |
| 48 | M&L for 150mm long extructed aluminium handle fabricated type complete all as specified and directed. |
| 49 | S&F Aluminium anodised barrel tower bolt of extruded section 200 mm size complete all as specified and directed. |
| 50 | S&F Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 51 | S&F in repair 5mm thick, 600mm wide rounded edge mirror of selected quality glass, with back polishig mounted and fixed with stainless steel decorative cap wahsers and screws set fixed on PVC rawl plugs complete all as specified and directed. |
| 52 | S&F Framed work as in doors,gates or staging to water tank of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed Fe 410-W (Gde- E- 250) quality- A complete all as specified & directed. |
| 53 | Dismantling water tanks of any description and in any position , of capacity exceeding 500 litres but not exceeding 1000 litres complete all as specified and directed. |
| 54 | S&F 1000 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position incl fixing arrangment for inlet/outlet/overflow & vent pipe of standard size including Ball brass valves , high pressure , with polythene float and fly nut complete & high-density plastic ball , suitable for 20 mm bore pipe, screwed for iron pipe and fixed complete all as specified & directed. |
| 55 | S&F (concealed / open) 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete with fitting including taking down existing GI tubing 20mm bore complete all as specified and directed. |
| 56 | S&F (concealed / open) 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete with fitting including taking down existing GI tubing 25mm bore complete all as specified and directed. |
| 57 | Dismantaling and taking down copper / aluminium point wiring any type / size complete with removing all connection and accessories such as switches , sockets, ceiling rose,pendent holder,fan regulator any type , all type of fitting , batten , steel or PVC conduit , casing caping etc compele and making good the disturbed surface complete all as specified and directed. |
| 58 | Taking down old and unserviceable sub main wiring any size / type / core incl earth wire complete with batten/conduit etc and making good the disturbed surface to match the existing disturbed surface complete all as specified and directed. |
| 59 | Taking down old and unsrevicable sheet metal enclosure , switch fuse unit , distribution bord any type /way / capacity including fuses,MCB's , insulator etc complete after removing all connection and making good the disturbed surface complete all as specified and directed. |
| 60 | M&L for Point wiring complete with FR PVC insulated unsheathed , 1100 V grade conforming to IS 694 , 1.5 Sqmm (Norminal area) multistranded ,copper conductor cable drawn through in non metallic rigid PVC conceled/surface conduit medium grade ,minimum 20 mm dia, ISI Marked, with sutaible size of 1 to 8 module metal flush boxes and back plate for mounting of modular switches/socket and regulators and including modular fornt plate with all acessories complete all as specified and directed. . |
| 61 | (a) One light point controlled by one way one switch SP 5 Amps ,240 V. |
| 62 | (b) One light point controlled by two 2 way switch SP 5 Amps ,240 V. |
| 63 | (c) One ceiling/exhaust fan point controlled by one way one switch SP 5 Amps, 240 V. |
| 64 | (d) One switch socket outlet 3 Pin, 5 Amps, SP on independent board. |
| 65 | (e) One switch socket outlet 3 Pin, 5 Amps, SP on same board. |
| 66 | All as per the above item No 60 herein before but with 2.5 Sqmm cable for 3 Pin 5/15 Amps switch socket outlet complete all as specified and directed. |
| 67 | S&F modular switch one way 6 Amps , 1 module type complete all as specified and directed. . |
| 68 | S&F modular switch two way 6 Amps , 1 module type complete all as specified and directed.. |
| 69 | S& f modular socket , 6 Amps , 2/3 pin combined 2 module complete all as specified and directed. |
| 70 | S& f modular switch socket combination, 6 Amps / 16 Amps , 2/3 pin combined 2 module complete all as specified and directed. |
| 71 | S&F ceiling rose surface backlite 65 x 20mm size three terminal ISI marked complete all as specified and directed. |
| 72 | Supply and fixing LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting upto PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through in PVC flexible conduit including as per site requirement and 2 Nos of round or square PVC bolck for fixing of FTL fitting complete all as per directed. |
| 73 | supply & fixing modular fan regulator step type , 1 module complete all as specified and directed. |
| 74 | M&L for sub main wiring with two runs of 6 Sqmm (2x6 sqmm )1100 volts grade single core FR PVC insulated unsheathed multistranded copper conductorcable confirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories concealed in walls/roofs/floors etc with one run of 6 Sqmm (1x6 sqmm ) single core FR PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and directed. Note:- 2 runs of 6 Sqmm ,one run of 6 Sqmm ( 2x6 sqmm + 1x6 sqmm ) cable and one meter of conduit will be measured as one unit again. |
| 75 | S&F sheet metal enclosures for distribution board when MCB to be used SPN ( Single pole and neutral ) 8 way, 240 Volts, sheet metal powder coated, IP 42 protection with 200 Amps rated bus bar, double door type complete all as specified and directed. |
| 76 | Supply & fixing MCB DBs TPN vertical, Double door, with provision of MCCB as incommer , 4 way, flush in wall, including civil work to match the disturbed surface with existing complete all as specified and directed. |
| 77 | S&F MCCB of capacity 100 Amps , 415 Volts, rupturing capacity 16 KA complete all as specified and directed. |
| 78 | S&F MCB SPN,40 Amps, 240 Volts, rupturing capacity 10 KA.\\"C\\" Series complete all as specified and directed. |
| 79 | S&F MCB SP, 5 to 32 Amps, 240 Volts, rupturing capacity 10 KA \\"C\\" Series complete all as specified and directed. |
| 80 | M&L , earthing complete for machinary / Equipment installed at power house / sub station with galavanised steel earth plate electrode of size 60 cmx 60 cmx 6 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5m below normal Ground level connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, washerws and check nuts all shown in electrical plate No.3 of SSR Part- I connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on completion all as per directed. |
| 81 | Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II. (ii) Earthing lead and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule. |
| 82 | Note :- (i) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (ii) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge. |
| 83 | Supply and lay pipe uPVC pipe including fittings of size 50 mm (2.0\\") dia complete all as specified and directed. |
| 84 | Supply and lay pipe uPVC pipe including fittings of size 25 mm (1.0\\") dia complete all as specified and directed. |
| 85 | supply and fix ball valve 25 mm dia including all fittings all as specfied and directed |
| 86 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 87 | S&f angle holder backlite with 1x10 Watt LED Bulb and making of connection with twin core flexible copper conductor from ceiling rose to fitting complete all as specified and directed. |
| 88 | Taking down and Repair of Ceiling fan/Exhaust fan, painting , overhauling , greasing and replacement of U/S componante like capacitor to make functional including provision of 3 core flexible copper conductor from ceiling rose to fan complete all as specified and directed . |
| 89 | NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysDec 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender