Tender For Restoration Of Rain Damages Of Lwss Jandori And Its Adjoining Villages From Kiarwa Khad Tehsil Kasauli Distt. Solan Hp. (Sh:- Construction of Sump Well 96 Kl, Construction of Slow Sand Filter 2 Nos., Construction of Pump House 50 Sqm, P/L/
Tender Overview
Project Description
Tender for Restoration Of Rain Damages Of Lwss Jandori And Its Adjoining Villages From Kiarwa Khad Tehsil Kasauli Distt. Solan Hp. (Sh:- Construction of Sump Well 96 Kl, Construction of Slow Sand Filter 2 Nos., Construction of Pump House 50 Sqm, P/L/J Of Rising Main From Rd 0 To Rd 200 & Providing/ Installation Of Pumping Machinery Of 60Hp). Under Pdna-2025.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m complete in all respect as per direction of Engineer-in-Charge. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand) : 4 graded stone aggregate 20 mm nominal size) complete in all respect. |
| 3 | Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge.“(Note :- Cement content considered in this item is @ 340 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). |
| 4 | All works upto plinth level |
| 5 | All works above plinth level upto floor V level |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 7 | Foundations, footings, bases for columns |
| 8 | Retaining walls, return walls, walls (any thickness) including attached pilasters,buttresses, plinth and string courses fillets, kerbs and steps etc |
| 9 | Sides and soffits of beams, beam haunchings, cantilivers, bressumers and lintels not exceeding 1.00 meter in depth in all heights from floor. |
| 10 | Suspended floors, roofs, landings, balconies and access platform |
| 11 | Edges of slabs and breaks in floors & walls (under 20 cmt. wide).(Detail for 12.00 rmt.) |
| 12 | Providing mild steel/tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level. |
| 13 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 14 | Providing, laying, jointing, testing and commissioning in trenches galvanised mild tube of following dia (Medium grade) as per IS:1239-2004 (Latest with up to date amendments) including providing and fixing tube fitting such as reducer increases, socket, union, tees, bends etc. where ever required (earth work in treanches to be measured and paid saparately) and as per the direction of Engineer-in-charge including entire carriage of material upto loads and lifts. |
| 15 | 65mm dia |
| 16 | 80mm dia |
| 17 | Providing & fixing 200 mm wide CI Rungs with chequarred/ribbed non slip surfaces i/c fixing in m/hole with 200 x 200 x100 mm cement conc.1:3:6 (1cement:3 sand:6 stone aggregate 40mm nominal size) in all lead & lifts and to the entire satisfaction of the engineer in charge.(Detail of cost for one no.) |
| 18 | Providing, laying, jointing and testing in trenches of mild steel electrically resistance welded of grade L-210 bevelled edge flanged/Butt welded pipe conforming to IS-3589-2001 of below mentioned grades in item as per dimensions, weight and test pressure mentioned therein code (mill tolerances to be restricted within+- 3%) in random lengths of 6 to 7 mtrs including the cost of fabrication of bends by butt welding from parent tube as required at site. Only 1% joints shall be flanged joint and remaining shall be welded joints and welding of pipes will be down as per IS:816-1969 with electrodes as per IS:814-2004 of make Adwani/Orelon (Adore)/ESAB. The laying & jointing of pipes should conform to IS:5822-1994 (earth work in trenches, flanged joint and butt welded joints except in bends to be measured and paid for sprately). The pipes and specials shall have out side wrapping with galvanized as per BIS-4736-1986, the galvanization is done by the manufacturing firm itself complete in all respect. |
| 19 | Replacement of Rising Main of MSERW pipe 80 mm dia and 6.40mm Thick from Rd-0 to Rd-200 m |
| 20 | Providing welding and fixing of M.S. flanges @ 1% of pipe length conforming to following tables as per IS 6392-1971 (Latest with up to date amendments) and welding of MS flanges with GI pipes in three layers i.e two-layer on outer faces and one layer on inner faces to make the joint leak-proof (The cost of proving and laying of GI pipes and butt welded joints to be measured and paid for separately). The welding of flanges should conform to IS 816-1969 with electrodes as per IS 814-1991 and the required number of nuts and bolts conforming to IS 1364, the thickness of gasket not less than 3.00 mm conforming to IS 2712-1998. The work shall be done as per the entire satisfaction of the engineer in charge of all leads and lifts. |
| 21 | Providing 80mm Dia MS Flange of grade FT-34 |
| 22 | Providing and erection of Centrifugual water polder pump sets at Ist stage of KSB/Calama/ Johnston make comprising to latest relevant BIS Code. The pump should have C.I. impeller of suitable alloys as per BIS 5659-1970 (6595-2018) with latest amendments (if any) suitable for Raw water with 10000 PPM turbidity having water lubricated bearing bush and stainless steel shaft with stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (water proof type) of required HP, RPM 2900 KSB/Calama/ Johnston make conforming to BIS 9283-2013 latest with up to date amendments, totally dust and water proof for submersible duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated to with stand long vertical loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump should include water level guards, erection clamps, cable clips and depth gauge with upto date amendments. It should include cost of bearing nuts bolts and painting etc. The pumping machinery shall be installed and anchored properly. All electrical equipments such as Starter, ICTP switches, MCB, Bush bar chamber, MCB, Panel board indicating lamps, Ammeter, Voltmeter, Hour run meter should be of electronic type , incoming and outgoing water proof cable for panel board, Double loop earthing, copper cable pressure gauge, capacitor, common header, sluice valve, NRV including erection and testing complete involving all wear and tear at the time of erection and testing The work should be completed to the entire satisfaction to the Engineer-in – Charge. Centrifugal Pump 2 Sets(1W+1S) of 60 H.P. with Pumping Rate of 4.99 LPS each with Static Head of 450.35m complete in all respect. (2 set of 60HP= 120HP). |
| 23 | Providing & fixing CI Sluice Valve (With Hand Wheel) IS: 780-1984 Class-1 upto 300mm dia (I/C brass spindle & as per 2906-1984 class -2 for Dia>300mm) complete with bolts nuts,rubber insertion etc.,(the tailpiece if required shall be measured & paid for Separatly) |
| 24 | 65mm Dia |
| 25 | 80mm Dia |
| 26 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand) : 6 graded stone aggregate 20 mm nominal size) |
| 27 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand) : 3 graded stone aggregate 20 mm nominal size) |
| 28 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing ::1:1½:3 (1 Cement: 1½ coarse sand) : 3 graded stone aggregate 20 mm nominal size) |
| 29 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing ::1:1½:3 (1 Cement: 1½ coarse sand) : 3 graded stone aggregate 20 mm nominal size) |
| 30 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size). |
| 31 | Brick work using common burnt clay building bricks in Superstructure in Cement Mortar 1:4 ( 1 Cement : 4 Sand) Second class bricks. COMPLETE IN ALL RESPECT AS PER DIRECTION OF Engineer-in-charge |
| 32 | 20 mm Cement Plaster in single coat on rough side of brick/ stone masonry for interior plastering upto floor two level including arrises, internal rounded angles, chamfers and / or rounded angles not exceeding 80 mm in girth and finished even and smooth.Cement mortar. (1:4) |
| 33 | 15 mm Cement Plaster in single coat on the rough side of brick/ concrete/ stone walls for interior plastering upto floor two level including arrises, internal rorunded angles, chamfers and / or rounded angles not exceeding 80 mm in girth and finished even and smooth. Cement mortar (1 cement: 4 sand). |
| 34 | 6 mm Cement plaster to ceiling in Cement Mortar 1:4 (1 Cement: 4 Sand). |
| 35 | Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1 cement : 3 sand : 6 Graded stone aggregated 20 mm nominal size). |
| 36 | Providing under layer for plinth protection of 75 mm thick (uncolsolidated) bed dry brick/stone aggregated 40 mm nominal size will rammed and consolidated and grouted with fine sand including preparation of ground. |
| 37 | White washing with lime on undecorated wall surfaces two coats to give & even shade i/c thorougly brooming the surface to remove all dirt,dust mortor & other foreign matter.(Details for 10 ^2 mts.) |
| 38 | Finishing wall with water proofing cement paint of approved brand & manufacture & of required shade on undecorated wall surfaces ( two coats) to give an even shade after thoroughly brushing the surface to remove all dirt & remains of loose powdered materials.(Details for 10 ^2 mts.) |
| 39 | Providing and fixing M.S fan clamp type 1 of 16 mm dia M.S bar bent to shape with hooked ends in R.C.C slab during laying including painting the exposed portion of loop, all as per standard design complete. (Detail of One Clamp ) |
| 40 | Providing & fixing Flood Light(OSRAM/RUNLITE/BRIDGELUX-1000W) in all accessories complete within all leads & lifts as per entire satisfaction of Engineer in Charge. |
| 41 | Stones/Boulders filling behind the r/walls, also under floor & upstream of i/gallary/under floor etc.in all lifts & leads complete in all respect.(Detail of cost for one cum) |
| 42 | Providing and laying heavy duty precast cement conrete inter locking paver blocks vibro compacted upto M-50 grade i/c border or kurb block grey or coloured over sub-base of concrete with 25mm thick average thickness of cement mortar 1:4 (1 cement : 4 sand) laid over and jointed with neat cement slurry mixed with pigment to match the shade of blocks i/c curing rubbing & polishing complete (Sub base concrete floor to be paid for separately) |
| 43 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer- in-Charge. |
| 44 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing. ( 30mm thick plain PVC door shutters). complete in all respect. |
| 45 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides complete in all respect. |
| 46 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partition etc with PVC/neoprens gasket etc. complete as per the architectural drawings and the directions of Engineer-In_charge (cost of aluminium snap beading shall be paid in basic item.) |
| 47 | Providing 40x3 mm flat iron hold fast 40 cm. Long including fixing to frame with 10 mm diameter bolts nuts and wooden plugs and embeding in cement concrete block 30x10x15cm. 1:3:6 (1 cement : 3 sand : gragded stone aggregate 20mm nominal size). |
| 48 | Providing & fixing anodized alluminium below mentioned fitting incuding anodized colour and shade with bolts & nuts &screws etc. complete. |
| 49 | Sliding Door Bolt (250X16 mm) |
| 50 | Tower Bolts 200 x 10 mm |
| 51 | Tower Bolts 150 x 10 mm |
| 52 | Handles 125 mm |
| 53 | Handles 100 mm |
| 54 | Providing and Fixing Aluminium anodised powder coated grill of required pattern to existing window/ventilatior with 80mmx80mm panels holes with 25x8mm thick aluminium flat in windows and ventilators including fixing with aluminium screws or boltsand nuts complete in alluminium channels base frames (Aluminium channels base frames to be measured and paid for separtely. |
| 55 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 56 | Providing and laying of Filter Sand complete in all respect as per dircetion of Engineer-in-Charge. |
| 57 | Top Layer Fine Sand |
| 58 | 2nd Layer 3 to 6mm |
| 59 | Providing amd laying of graval complete in all respect as per direction of Engineer-in-Charge. |
| 60 | 3rd layer aggregate 6mm to 20mm |
| 61 | 4th layer aggregate 20mm to 25mm |
| 62 | 5th layer aggregate 50 mm to 75mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender