Tender for Civil Works For Modification Of Exsting Building No 14F To Accommodation The New Mixer At Acem Nasik
BOQ
| Sl. No. | Item Description |
| 1 | SUBHEAD- I : Periodical Services |
| 2 | Providing and applying White washing with lime to give an even shade : |
| 3 | Old work (two or more coats) |
| 4 | Providing and applying Colour washing such as green, blue or buff to give an even shade : |
| 5 | New work (two or more coats) with a base coat of white washing with lime |
| 6 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour |
| 7 | Old work (one or more coats) |
| 8 | Finishing walls with water proofing cement paint of required shade : |
| 9 | Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat. |
| 10 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 11 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface |
| 12 | Providing and applying two coats of fire retardant paint on cleaned wood / ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant. |
| 13 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 14 | One or more coats on old work |
| 15 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 16 | With cement mortar 1:4 (1cement: 4 coarse sand) |
| 17 | Providing and Laying Chemical Grout of FOSROC CONBEXTRA GP2 or equavalent |
| 18 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose.The payment will be made once irrespective of duration of scaffolding. |
| 19 | SUBHEAD- II: Demolishion Work |
| 20 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 21 | Disposal of building rubbish/malba/similar unsericeable, dismantled or waste materials by mechanical means including loading transporting unloading to approved municipal dumping ground or as approved by Engr-in-charge beyond 50 minitial lead for all leads, including all lifts involved |
| 22 | Credit for Scrap Iron (Reinf. Steel) |
| 23 | SUBHEAD- III: Steel Work |
| 24 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 25 | Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, platesetc. Including welding, grinding,buffing, polishing and making curvature (wherever required) and fitting the same with necessary sainless steel nuts and bolts complete, i/c fixxing the railig with necessary acessories & stainless steel dash fasteners, stainless stee; bolts ec, of required size, on the top of the floor or the side of waist slab woth suitable arrangement as per approval of Engineer -in- charg, ( for payment purpose onlyweight pf stainless stee; members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 26 | SUBHEAD- IV : False Ceiling |
| 27 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, finishing with jointing compound in 3 layers covering upto 150 mm or both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I. |
| 28 | SUBHEAD- V: Internal Electric work |
| 29 | Supply of 150W Highbay flame proof LED flood light ensure powerful and safe illumination in hazardus enviroment, certified for Zone-1 & 2 areas with IS/IEC - 60079-1: 2014 Deliver > 100 lumens per watt for efficient bright illumination, Die cast aluminium housing and ring with hammertone Graphite Grey finish and toughened heat resistant flat glass. with IP -66 protection and operating voltage 120 V to 277 V AC with integrated 10 KV surge protection with standard EYE bolt mounting and M20X1.5 threaded cable entry complete all as specified and directed by Engr - in - charge |
| 30 | Supply of 72 Watt rating LED Street light clour temperature-6500K, ingress Protection-IP20, Poly carbonate diffuser, 240 volt 50 Hz AC, body die- cast aluminium/ CRCA/ Extruded aluminium, having short circuit protection, Overload protection,surg and transients protection complete with all accessories. |
| 31 | Supply Of PVC Exhaust Fan 250 mm sweep single phase 230V 50HZ Complete with all accessories as required |
| 32 | LED Batten light (System lumen efficacy >135lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following bodymaterial and construction as per IS : 10322 withdriver (Replaceable) as per the requirement withDriver efficiency >85% ,Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker shouldbe below 5 %), life time (LED, Driver & electricalcircuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till lifeends, CCT 3000°K / 4000°K / 5700°K /6500°K(As per ANSI Bin), SDCM(Standard DeviationColor Matching) <3, Maximum power consumptionshould not more than the specified rating andFixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing complete inall respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. |
| 33 | as required withMinimum 5 year OEM warranty. System lumenefficacy >135 lm/Watt output . LM79 & LM80 Testreport and all testing required for LED fixtures As per BIS shall be submitted.. Shape size andCCT shall be as approved by Engineer-in-Charge asper requirement. (Thermal management: heat sinkof aluminium housing such that LED junctiontemperature shall not rise above 90°C). |
| 34 | 36 watt |
| 35 | Providing and Fixing cholorinated polyvinyl chloride pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fitting, I/C fixing the pipe with clamps at 1.0mm spacing this include joining of pipes and fittings with one step CPVC Solvent cement,trencing refilling and testing of joints complete as per direction of engineer in charge |
| 36 | 20mm Nominal Dia Pipes |
| 37 | 32mm Nominal Dia Pipes |
| 38 | SUBHEAD- VI : Water Supply |
| 39 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS:12701 marked with cover and suitable locking arrangement and making necessary holes for inlet , outlet and overflow pipes but without fitting and base support for tank |
| 40 | SUBHEAD- VII: Air Conditioning |
| 41 | Supplying, instatllation, testing and commissioning of aircooled hi wall split type air conditioners complete with indoor unit ,outdoor unit , surface,concelaed copper refrigerent piping with insulation (closed cell elastromeric nitrile rubber tubular pipe section)upto 3 mtr,copper power cable upto 3.5mtr i/c drain pipe R-32/R-410/R-407 Green refrigent wireless remote control suitable for working between 180-250v with low and high voltage cutoff and 50hz 1 phase ac supply capable performance cooling , dehumidifcation,air circulation of following capacity with scroll / rotary compressor the system shall be able to deliver 100% of the rated capacity upto 42c min 5year original equipment manufacturer warranty both compressor and printed board must comply electrical cable IS694 OR IS9968 temperature sensing control is international compressor IS10617 heat exchanger IS11329 capacitor IS2993 and motor IS12615 completer as perCPWD Specification and IS 1391 Part II 2023. The system shall be operate upto 50c |
| 42 | 2TR With 5 star BEEE Rating |
| 43 | Repairing of existing 3x48TR Scroll Air Cooled Chillers including dismantling, cleaning, servicing, installation of spare-parts, oiling, greasing, painting, re-assembling, testing & commissioning etc all complete including labour, machinery, minor - Consumables Spares like Nut bolts, vacuum Pump Oil Paint etc, transportation of labour & machinery for carrying out repair work and other lump sum expenses as per the direction of Engineer- in- charge. Note: Spare parts will be measured and Paid separately on actual basis as per the requirement and approval of the same can be obtained from E-in-charge before procurement. |
| 44 | Supply of following Spare Parts Items as required for the repairing work of existing 3x48TR Scroll Air Cooled Chillers per the direction of Engineer- in- chargeNote: Rate Included with transportation |
| 45 | Supply of Scroll Compressor Danfoss Make |
| 46 | Supply of Refrigerant Gas R407C Gas |
| 47 | Rewinding of Condenser Fan Motors |
| 48 | Rewinding OF Chiller pumps |
| 49 | Supply of Temperature Sensor |
| 50 | Supply of PRV |
| 51 | Supply of Catchall Filter |
| 52 | Supply of Contactors 3TF34(Siemans Make) |
| 53 | Supply of Contactors 3Ts30(Siemans Make) |
| 54 | Supply of Microprocessor’s Controller |
| 55 | Supply of Expansion Valve SVE-10 |
| 56 | Supply of Electrical Panel Lock |
| 57 | 2A Fuse HRC |
| 58 | M2PD WOD 1 to 10 amp rating |
| 59 | M3PD o to 3A |
| 60 | V Belt B -71 |
| 61 | Humidifier Pump |
| 62 | Supply of Condenser Motors Fan Blades |
| 63 | Supply of Comp CC Heaters |
| 64 | Supply of Nitrogen Cylinder |
| 65 | Supply of Solenoid VALVE Coils (180) |
| 66 | Supply of water Flow Switch |
| 67 | Supply of 3FS / 4FS Cards |
| 68 | Supply of Comp/ Cond Electrical Connectors |
| 69 | Supply of Control Fuse Assembly 6 AMPS |
| 70 | Supply of LP/HP cutout Switch |
| 71 | Credit for items/ spareparts replaced |
| 72 | Scroll Compressor |
| 73 | Fan Motor |
| 74 | Contactors 3TF34 |
| 75 | Contactors 3Ts30 |
| 76 | Humidifier Pump |
| 77 | Fan Blades |
| 78 | Heater |
| 79 | Winding material of Fan/ pump Motors (copper) |
| 80 | Other minute Scrap material Parts in Metal |
| 81 | Other minute Scrap materials Parts other than Metal like Plastic/ PVC etc |
| 82 | SUBHEAD- VIII: EOT Crane |
| 83 | Providing and fixing of hand operated Winch system for opening and closing of MS structural/ sheet door of 1000Kg weight (approx) provided for slab cutout at 13 mtr level complete all as specified and directed by engr-in-charge. Payment for MS door will be measured and paid seperately. |
| 84 | Modification of Crab unit of 05T FLP EOT Crane to achieve 15mtr lift against existing 10Mtr lift including dismantling, cleaning, servicing, replacement & installation of spare-parts like drum, rope of suitable size & dia to achieve the scope, including oiling, greasing, painting, re-assembling, testing & commissioning etc all complete including labour, machinery, minor - consumables, transportation and any other lump sum expenses etc as per the direction of Engineer- in- charge. Note: 100% payment shall be released only after the testing & commissioning of the crane |
| 85 | Credit for the items replaced (MS Scrap materials like Rope, Drum etc) |
| 86 | SUBHEAD - IX: ROAD/ HARD STANDINGS, AREA DEVELOPMENT & DRAINAGE |
| 87 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.:All kinds of soil. (No additional lift payment will be given for mechanical excavations) |
| 88 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.All kinds of soil.(No additional lift payment will be given for mechanical excavations) |
| 89 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. (No additional lift payment will be given for mechanical excavations) |
| 90 | Ordinary rock |
| 91 | Hard rock (blasting prohibited) |
| 92 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(5% voids to be deducted) |
| 93 | Supply and filling of approved earth obtained from outside MD land for formation of sub base including spreading in layers not exceeding 200mm in thick,necessary watering,consolidation to the required level,gradient and camber with 8-10 Tonne road roller to achieve minimum of 95% proctor density including cost of excavation all as per specifications and drawings at all lead and lift and as directed by the Engineer.(Payment shall be made for consolidated quantity after deduction of 5% for voids.) |
| 94 | Credit For Hard Rock obtained from excavation |
| 95 | Supplying and filling in plinth with River sand / M-Sand under floors, including watering, ramming, consolidating and dressing complete |
| 96 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 97 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 98 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 99 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 100 | Cement mortar 1:6 (1 cement : 6 coarse sand |
| 101 | Random rubble masonry with hard stone in superstructure and above plinth and upto floor five level, including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement Mortar 1:6(1 Cement : 6 coarse sand) |
| 102 | Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) :Flush/ Ruled pointing |
| 103 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 104 | Providing and fixing pre-moulded joint filler in expansion joints of RCC roads/ CC pavement after making the joints dust free with high pressure air jet cleaner, all complete as per direction of the Enginner-in-charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35% conforming to IS: 1838 for bibre board and IS: 1834 for hot sealing bitumen compund grade A) |
| 105 | Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Using grade 'A' sealing compound conforming to IS: 1834. |
| 106 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 107 | 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern |
| 108 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. |
| 109 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 110 | Foundations, footings, bases of columns, etc. for mass concrete |
| 111 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 112 | 150 mm dia RCC pipes. |
| 113 | 300 mm dia RCC pipes. |
| 114 | 450 mm dia RCC pipes. |
| 115 | SUBHEAD - X:TRAVERSE |
| 116 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.:All kinds of soil. (No additional lift payment will be given for mechanical excavations) |
| 117 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. (No additional lift payment will be given for mechanical excavations) All kinds of soil. |
| 118 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. (No additional lift payment will be given for mechanical excavations) |
| 119 | Ordinary rock |
| 120 | Hard rock (blasting prohibited) |
| 121 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(5% voids to be deducted) |
| 122 | Supply and filling of approved earth obtained from outside MD land for formation of sub base including spreading in layers not exceeding 200mm in thick,necessary watering,consolidation to the required level,gradient and camber with 8-10 Tonne road roller to achieve minimum of 95% proctor density including cost of excavation all as per specifications and drawings at all lead and lift and as directed by the Engineer.(Payment shall be made for consolidated quantity after deduction of 5% for voids.)(5% voids to be deducted) |
| 123 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 124 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.: |
| 125 | All works upto plinth level: |
| 126 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 127 | All works above plinth level upto floor V level |
| 128 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 129 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 130 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete (Below & above plinth & at all heights.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 131 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 132 | Foundations, footings, bases of columns, etc. for mass concrete |
| 133 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 134 | Lintels, beams, plinth beams, girders, bressumers and cantilevers Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysDec 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents