Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #58628805

Tender For Special Repairs To Replacement Of Old Apfc Panel At Various Location Under Ge (Army) Baroda.

Issued by Statutory Bodies & Commissions/Committees · Vadodara, Gujarat
Tender Value
33.37 Lakhs
Estimated cost
Bid Submission
09 Dec 2026
17 days left
EMD
66740
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Vadodara → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repairs To Replacement Of Old Apfc Panel At Various Location Under Ge (Army) Baroda.

BOQ

Name of Work:- SPECIAL REPAIRS TO REPLACEMENT OF OLD APFC PANEL AT VARIOUS LOCATION UNDER GE (ARMY) BARODA.
Sl. No. Item Description
1Supply, Installation, testing and commissioning of Automatic Power Factor Correction (APFC) panel,outdoor type floor mounted free standing totally enclosed, extendable, IP 65, of 100 KVAR capacity for 3 phase, 415 V + 10 %, 50 Hz AC System for Ambient temperature -5°C to +40°C, fabricated in compartmentalised designed made of CRCA sheet steel of 3.0mm thick for framework & covers, 3 mm thick for gland plate i/c cleaning & finishing complete with 9 tank process for powder coated of approved shade ( RAL 7032-Siemens Gray or as approved by Engineer-in-Charge), having front section (switch gear and control accessories) and rear section capacitor and reactor, front and rear access, having suitable current carrying capacity, extensible TPN Aluminium alloy bus bar of high conductivity, DMC/SMC bus barsupports, bottom base channel of MS Section, fabrication shall be done in transportable section,entire panel shall have common copper earth bar of minimum size of 25mm x 5mm with 2 nos. earth studs, the earth terminals provided on the body of capacitor bank shall also be bonded to the main capacitor panel earth bus with 2 nos. 8 SWG or 6 SWG GI earth wires/ equivalent size of copper conductor cable, forced ventilation for maintaining temperature rise not more than 5°C from ambient, interconnections, connections with 14% detuned reactor and heavy duty 525 V ISI marked Impregnated MPP(Metalized Polypropylene) Capacitor (IS 13340 Part -1 & 2) APFC Panel shall be in compliance with IS :16636. as per below details.(A) Incomers Suitable capacity MCCB Microprocessor base with O/C, S/C, E/L release of TPN 50KA breaking capacity (Ics=Icu), ON, OFF, Trip, R, Y, B - LED Indicating Lamp set along with required Instruments and accessories with extended rotary handle and door interlocking arrangement. Current rating of the Incomer in ampere shall be APFC Panel rating in KVAR x 1.4 x 1.5 or Nearest higher standards rating.(B) Instruments & Indications i) 3-Phase current sensing APFC microprocessorrelay/controller , advance 8 stages (8 stages for capacity 100 KVAR) with Communication Ethernet/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge and having display of Phase wise V, A, PF, Cos-Phi, Kw, KVA,KVAR, THD-V , THD-I, harmonics up to 31 level. 3 nos of dual core CT's accuracy class 1, 15VA at incomer of PCC Panel for APFC relay.ii) Auto Manual Selector switch, auxiliary contactors with timer for delay in manual mode.iii) Digital Multi function meter with LED Display for V,A, PF, KW, KVA, KVAR, THD-V & I, Frequency.iv) Suitable rating control transformer shall be provided for control and indication circuit.v) All components like control transformer, meter, relay and indicating lamp shall be protected by using suitable rating individual MCB's.vi) Wiring of the control circuit shall be done by using 2.5 sq mm, FRLS/HFFR 1100 V grade, PVC insulated multi stranded copper control wire.(C) Bus Bars 1.3 Amp per Sq.mm,TPN, Electrolytic grade Aluminium bus bar of capacity 1.5 times of incomer rating .(D) Outgoings (APFC Section) Selection of the capacitors combinations shall be for continuous rating and each capacitor bank shall have suitable capacity Heavy Duty ISI Marked Capacitor, capacitor duty contactor,the capacitor shall be mounted on channel with base of perforated M S Powder coated sheet, connections inter connections etc. and relevant IS Code having following(i) Capacitor bank ratings & stages shall be as per the technical specifications sheet of OEM.(ii) Capacitor will be MPP self healing type with discharge resistor, pressure release mechanism. (iii) Since Capacitor Voltage is 525 Volts, thus higher KVAR has to be considered to get rated output at 415 Volts.(iv) 14% Detuned Reactor of class H insulation & 150% linearity in series with Capacitor.(Note: Technical specifications sheet for selection of the capacitors combinations shall be provided as per OEM recommendation with due consideration of number of capacitors i.e. 1 KVAR, 2 KVAR, 3 KVAR, 5 KVAR, 10 KVAR.....for smooth correction Please Enable Macros to View BoQ information
2Supply, Installation, testing and commissioning of Automatic Power Factor Correction (APFC) panel,outdoor type floor mounted free standing totally enclosed, extendable, IP 65, of 100 KVAR capacity for 3 phase, 415 V + 10 %, 50 Hz AC System for Ambient temperature -5°C to +40°C, fabricated in compartmentalised designed made of CRCA sheet steel of 3.0mm thick for framework & covers, 3 mm thick for gland plate i/c cleaning & finishing complete with 9 tank process for powder coated of approved shade ( RAL 7032-Siemens Gray or as approved by Engineer-in-Charge), having front section (switch gear and control accessories) and rear section capacitor and reactor, front and rear access, having suitable current carrying capacity, extensible TPN Aluminium alloy bus bar of high conductivity, DMC/SMC bus barsupports, bottom base channel of MS Section, fabrication shall be done in transportable section,entire panel shall have common copper earth bar of minimum size of 25mm x 5mm with 2 nos. earth studs, the earth terminals provided on the body of capacitor bank shall also be bonded to the main capacitor panel earth bus with 2 nos. 8 SWG or 6 SWG GI earth wires/ equivalent size of copper conductor cable, forced ventilation for maintaining temperature rise not more than 5°C from ambient, interconnections, connections with 14% detuned reactor and heavy duty 525 V ISI marked Impregnated MPP(Metalized Polypropylene) Capacitor (IS 13340 Part -1 & 2) APFC Panel shall be in compliance with IS :16636. as per below details.(A) Incomers Suitable capacity MCCB Microprocessor base with O/C, S/C, E/L release of TPN 50KA breaking capacity (Ics=Icu), ON, OFF, Trip, R, Y, B - LED Indicating Lamp set along with required Instruments and accessories with extended rotary handle and door interlocking arrangement. Current rating of the Incomer in ampere shall be APFC Panel rating in KVAR x 1.4 x 1.5 or Nearest higher standards rating.(B) Instruments & Indications i) 3-Phase current sensing APFC microprocessorrelay/controller , advance 8 stages (8 stages for capacity 100 KVAR) with Communication Ethernet/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge and having display of Phase wise V, A, PF, Cos-Phi, Kw, KVA,KVAR, THD-V , THD-I, harmonics up to 31 level. 3 nos of dual core CT's accuracy class 1, 15VA at incomer of PCC Panel for APFC relay.ii) Auto Manual Selector switch, auxiliary contactors with timer for delay in manual mode.iii) Digital Multi function meter with LED Display for V,A, PF, KW, KVA, KVAR, THD-V & I, Frequency.iv) Suitable rating control transformer shall be provided for control and indication circuit.v) All components like control transformer, meter, relay and indicating lamp shall be protected by using suitable rating individual MCB's.vi) Wiring of the control circuit shall be done by using 2.5 sq mm, FRLS/HFFR 1100 V grade, PVC insulated multi stranded copper control wire.(C) Bus Bars 1.3 Amp per Sq.mm,TPN, Electrolytic grade Aluminium bus bar of capacity 1.5 times of incomer rating .(D) Outgoings (APFC Section) Selection of the capacitors combinations shall be for continuous rating and each capacitor bank shall have suitable capacity Heavy Duty ISI Marked Capacitor, capacitor duty contactor,the capacitor shall be mounted on channel with base of perforated M S Powder coated sheet, connections inter connections etc. and relevant IS Code having following(i) Capacitor bank ratings & stages shall be as per the technical specifications sheet of OEM.(ii) Capacitor will be MPP self healing type with discharge resistor, pressure release mechanism. (iii) Since Capacitor Voltage is 525 Volts, thus higher KVAR has to be considered to get rated output at 415 Volts.(iv) 14% Detuned Reactor of class H insulation & 150% linearity in series with Capacitor.(Note: Technical specifications sheet for selection of the capacitors combinations shall be provided as per OEM recommendation with due consideration of number of capacitors i.e. 1 KVAR, 2 KVAR, 3 KVAR, 5 KVAR, 10 KVAR.....for smooth correction Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58628805
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 33.37 Lakhs
LAST DATE 09-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repairs To Replacement Of Old Apfc Panel At Various Location Under Ge (Army) Baroda.
Basic Detail
Tender No 8137
Bidding Type Tender
Location
City Vadodara
State Gujarat
Key Dates
Publish Date 20 Nov 2026
Submission Date 09 Dec 2026
Open Date 10 Dec 2026
Finance
Tender Value 33.37 Lakhs
Tender Fee 500
EMD 66740
Exemption Available
Document List
04080ded-0dcd-4009-823e-1af3d378a0f2.html
BOQ_897116.xls
Tendernotice_1.pdf
Tenderpages8137.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Dec 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

04080ded-0dcd-4009-823e-1af3d378a0f2.html

xls

BOQ_897116.xls

pdf

Tendernotice_1.pdf

pdf

Tenderpages8137.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender