Defence Statutory Bodies & Commissions/Committees Closing in 23 days TDR #58628801

Tender For Rep/ Maintenance Of Fire Fighting Accessories Including Fire Detectore, Fire Alarm Panel, At installation Shivaji Lonavla (8488/E8)

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
17.08 Lakhs
Estimated cost
Bid Submission
14 Dec 2026
23 days left
EMD
34200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Rep/ Maintenance Of Fire Fighting Accessories Including Fire Detectore, Fire Alarm Panel, At installation Shivaji Lonavla (8488/E8)

BOQ

Name of Work:- REP/ MAINT OF FIRE FIGHTING ACCESSORIES INCLUDING FIRE DETECTORE, FIRE ALARM PANEL, AT INS SHIVAJI LONAVLA (8488/E8)
Sl. No. Item Description
1Routine maintenance of fire fighting system & Fire alarm system by attending fault testing of system, Monthly checking of system etc, including replacement of minor components including preventive Maintanence by replacing parts also for fire fighting system, fire alarm system installed at LOGISTIC Building to ensure satisfactorily working of entire system and comprising following: (a) FOUR TO TWENTY Zone main fire alarm control panel with each zone battery charger and 230 V power units.(b) DETECTOR OF ANY TYPE, head detector, response indicator, manual call point and hooters. etc(c) All cable connections of control panel.
2All as per above item No 1 but MENAKA Building.
3All as per above item No 1 but KASTURI Building.
4All as per above item No 1 but LM2500 Building.
5All as per above item No 1 but CAC Building.
6All as per above item No 1 but CCEL,SECON Building.
7Supply and fix in repairs Zone cards of makes as per site requirement all as specified and as directed.
8Supply and fix in repairs power card
9Supply and fix in repairs of manual call point duly painted in red colour paint fitted with front glass (to be broken in case of fire) complete with test key to check the response with out breaking the glass of makes as per site requirement all as specified and as directed.
10Supply and fix in repairs electronic hooters of makes as per site requirement all as specified and as directed.
11Supply and fix in repairs smoke detector of makes as per site requirement all as specified and as directed.
12Supply and fix in repairs Multi sensor detector of makes as per site requirement all as specified and as directed.
13Supply and fix in repairs Heat detector of makes as per site requirement all as specified and as directed.
14Supply and fix in repairs Addressable/Conventional Beam Detector with 4 pieces Reflector, Detection Range 8-50 Meters of makes as per site requirement all as specified and as directed.
15Supply and fix in repairs Pressure gauge 100 mm dia with ball valve of pressure 25 Kg/Sqcm of makes as per site requirement all as specified and as directed.
16Supply and fix in repairs Fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector all as directed.
17Supply,install,testing and commissioning of Fire Fighting motor control panel floor mounting Indoor type fabricated from 2.0 mm thick CRCA sheet, dust and vermin proof complete with aluminium bus bar 160 Amp and with following accessories:-MCCB 125 A TPN 37 kA - 01 No (Incomer)Outgoing-MCCB 100 A TPN25 KA -01 noMCCB 100 A TPN25 KA -01-noMCCB 60 A TP 18 kA -01 noMCCB 30 A TP 25 kA-01 no.MF MeterIndicator lamps,CT's etc complete all as specified and as directed.
18Supply and fix in repairs fabricated hose cabinet mounted on wall mounted made out of 16 gauge MS Sheet of size 800X600x250mm with double door with 4 mm thick glasses and door frame made of 2.0mm MS sheet painted fire red out side and brilliant white inside yard with lock two keys
19Supply and fix in repairs einforced rubber cotton synthetic fibre circular woven jacketted fire delivery hose 63 mm dia treated against rot / mystex having 38KG/cm2 working pressure bearing IS-636 type \\"A\\" 15 Mtrs length with male and female coupling confirming to IS-903 all as directed
20Supply and fix in repairs hose reel swinging wall mounted type comprising rubber hose 19/20mm dia 30m long high pressure double braided bearing IS-5132 type'A' 5 mm bore PVC shut off nozzle and 25mm gunmetal inlet valve conforming to IS-884 and connected to down comer all as directed
21Supply and fix in repairs fire hydrant landing valve type A (single head outlet) of 63 mm dia conforming to IS 5290 with PVC blank cap and chain and having suitable flanges for 100 mm dia down comer all as directed
22Supply and fix in repairs gun metal branch pipe 63mm dia male instantaneous inlet threaded outlet fitted with hexagonal based nozzle of 12.5 mm dia heavy duty conforming to IS-903 all as directed
23Supply and fix in repairs Gun metal fire brigade in let connection two way for connecting to external fire hydrant ring main consisting of two nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia, flanged outlet complete with all accessories.
24Supply and fix in repairs Bulb type gun metal sprinkler head consealed type set to operate at 68 degree C all as directed.
25Supply and fix in repairs FRLS copper armoured cable of cross section 1.5 sqmm, 2 core 1100V grade,laid in duct,fixed on wall/ceilling using GI clips drawn through pipes or fixed to detectors
26Supply and fix in repairs 4c x 1.5 sqmm PVC insulated , FRLS armoured and overall PVC sheathed cable , laid on wall / ceiling using GI clamps as required includung final termination on Repeator Panel. Make :- Polycab
27Supply and fix in repairs MS pipe “Heavy class” of thick ness 4 mm including fittings, 200 mm complete including testing and commissioning to the satisfaction of Engr-in-Charge
28Supply and fix in repairs MS pipe “Heavy class” of thck ness 4 mm including fittings, 150 mm complete including testing and commissioning to the satisfaction of Engr-in-Charge
29Supply and fix in repairs MS pipe “Heavy class” of thck ness 4 mm including fittings, 100 mm complete including testing and commissioning to the satisfaction of Engr-in-Charge
30Supply and fix in repairs pipe galvanized, “Heavy class”, including fittings, 25 mm dia complete including testing and commissioning to the satisfaction of Engr-in-Charge
31Supply and fix in repairs pipe galvanized, “Heavy class”, including fittings, 40 mm dia complete including testing and commissioning to the satisfaction of Engr-in-Charge
32Supply and fix in repairs pipe galvanized, “Heavy class”, including fittings, 50 mm dia complete including testing and commissioning to the satisfaction of Engr-in-Charge
33M & L for disconnecting carefully and dismantling the pump set from motor unit and opening complete pump set, cleaning replacing of unserviceable parts such as gun metal bushes,bearings, rubber packing, MS Nut, Bolts, rubber coupling (spider), Air valve and worn out parts etc and reassembling, re-installing commissioning and testing for satisfactory running complete all as specified and as directed for following capacity of pumps :-Centrifugal pump set of 40 HP capacity.
34All as per item no.33 but Centrifugal pump set of 10 HP capacity.
35All as per item no.33 but Centrifugal pump set of 7.5 HP capacity.
36All as per item no.33 but Centrifugal pump set of 5 HP capacity.
37M & L for rewinding electric motor by dismantling from cable connection pump set and foundation, dismantling complete motor removing all parts thoroughly removing burnt copper wire with new one and rewinding motor 3 phase 415 with same gauge, same No of turns of super enamel copper wire including E class insulating material, varnishing, heating etc re-installing and testing etc complete all as directed by Engr-in-Charge for the following capacity:-Note :- Unit rate quoted shall be deemed to include for minor unserviceable parts as mentioned/ required for repairs.Centrifugal pump set of 40 HP capacity.
38All as per item no.37 but Centrifugal pump set of 10 HP capacity.
39All as per item no.37 but Centrifugal pump set of 7.5 HP capacity.
40All as per item no.37 but Centrifugal pump set of 5 HP capacity.
41Supply and fix in repairs sluice valve of size 80 mm PN 16.
42Supply and fix in repairs Butterfly valve of size 100 mm PN 16.
43Supply and fix in repairs Non return Butterfly valve of size 100 mm PN16
44Supply and fix in repairs BrassBall valve of size 25 mm . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58628801
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 17.08 Lakhs
LAST DATE 14-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Rep/ Maintenance Of Fire Fighting Accessories Including Fire Detectore, Fire Alarm Panel, At installation Shivaji Lonavla (8488/E8)
Basic Detail
Tender No GE/LONAVLA/8488/E8
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 20 Nov 2026
Submission Date 14 Dec 2026
Open Date 16 Dec 2026
Finance
Tender Value 17.08 Lakhs
Tender Fee 500
EMD 34200
Exemption Available
Document List
090b2910-2974-44ad-b2bc-e2c13d557a31.html
8488TENDERDOCUMENTS.pdf
BOQ_897016.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 23 days
Dec 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
html

090b2910-2974-44ad-b2bc-e2c13d557a31.html

pdf

8488TENDERDOCUMENTS.pdf

xls

BOQ_897016.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender