Tender For Design And Built For Provision Of Foundation For Technical Tower With Allied Work At installation Dweeprakshak And installation Jatayu, Lakshadweep
Tender Value
3.90 Crore
Estimated cost
Bid Submission
28 Dec 2026
37 days left
EMD
4.65 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Lakshadweep District → Lakshadweep
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Design And Built For Provision Of Foundation For Technical Tower With Allied Work At installation Dweeprakshak And installation Jatayu, Lakshadweep
BOQ
| Sl. No. | Item Description |
| 1 | Total amount of Sch 'A' part-I (Buildings/ Structures) |
| 2 | Engineering, Design, arch and structural drawings, vetting and Construction of RCC DG Shed including two concrete platforms for DG and foundation complete all as in permanent specifications including earth work excavation, foundation as per design, plinth/ grade beam below GL and connected items, super structure, floor and roof slab etc complete all as specified and as directed at INS Dweeprakshak, kavaratti. |
| 3 | Engineering, Design, arch and structural drawings, vetting and Construction of RCC DG Shed including two concrete platforms for DG and foundation complete all as in permanent specifications including earth work excavation, foundation as per design, plinth/ grade beam below GL and connected items, super structure, floor and roof slab etc complete all as specified and as directed at INS Jatayu, Minicoy. |
| 4 | Engineering, Design, arch and structural drawings, vetting and Construction of Platform for E/M Mast including foundation complete all as in permanent specifications including earth work excavation, foundation as per design, plinth/ grade beam below GL and connected items, super structure, floor and roof slab etc complete all as specified and as directed at INS Dweeprakshak, kavaratti. |
| 5 | Engineering, Design, arch and structural drawings, vetting and Construction of Platform for Shelter including foundation complete all as in permanent specifications including earth work excavation, foundation as per design, plinth/ grade beam below GL and connected items, super structure, floor and roof slab etc complete all as specified and as directed at INS Dweeprakshak, kavaratti. |
| 6 | Engineering, Design, arch and structural drawings, vetting and Construction of Platform for E/M Mast including foundation complete all as in permanent specifications including earth work excavation, foundation as per design, plinth/ grade beam below GL and connected items, super structure, floor and roof slab etc complete all as specified and as directed at INS Jatayu, Minicoy. |
| 7 | Engineering, Design, arch and structural drawings, vetting and Construction of Platform for Shelter including foundation complete all as in permanent specifications including earth work excavation, foundation as per design, plinth/ grade beam below GL and connected items, super structure, floor and roof slab etc complete all as specified and as directed at INS Jatayu, Minicoy. |
| 8 | Total amount of Sch 'A' part-IIA (Excavation, Earthwork, Site Clearance & Site Development) |
| 9 | Total amount of Sch 'A' part-IIB (Excavation, Earthwork, Site Clearance & Site Development) |
| 10 | Total amount of Sch 'A' part-IIIA (Internal water supply) |
| 11 | Total amount of Sch 'A' part-IIIB (Internal water supply) |
| 12 | Total amount of Sch 'A' part-IVA (External Electric Supply) |
| 13 | Total amount of Sch 'A' part-IVB (External Electric Supply) |
| 14 | Total amount of Sch 'A' part-VA (Lightning Protection) |
| 15 | Total amount of Sch 'A' part-VB (Lightning Protection) |
| 16 | Total amount of Sch 'A' part-VIA (Road/ Path/ Hardstanding) |
| 17 | Total amount of Sch 'A' part-VIB (Road/ Path/ Hardstanding) |
| 18 | SCH. 'A' PART -VII (Miscellaneous B/R & E/M Items )Note :- This schedule is not pre priced by MES and the pre priced rate indicated as \\"Rs. 0.00\\" under Col.5 signifies this fact only. |
| 19 | KAVARATTIM&L Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sqmm nominal cross-sectional area, single core, PVC insulated and sheathed FRLS cable 1100 volts grade, ISI-694 marked including heavy duty non metallic rigid PVC conduit and conduit accessories concealed in wall/roof/floor etc. ISI marked including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) including PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core F.R.L.S cable as earth continuity conductor to common earth and connecting to earth dolly and cutting chases for steel conduits/boxes etc complete all as specified and directed at site for one light/Bell point controlled by one 5/6 amps one way switch. |
| 20 | All as per item No 13 above but for one ceiling fan point controlled by one 5/6 amps one way switch all as specified and directed. |
| 21 | All as per item No 13 above but for one exhaust fan point controlled by one 5/6 amps one way switch all as specified and directed. |
| 22 | All as per item No 13 above but for one socket outlet, three/five pin, 5 Amp, independent controlled by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin all as specified and directed. |
| 23 | Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 2.5 Sqmm nominal cross-sectional area, single core, PVC insulated and sheathed FRLS cable 1100 volts grade, ISI-694 marked including heavy duty non metallic rigid PVC conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket), including PVC insulated multi-stranded copper conductor 2.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly and cutting chases for steel conduits/boxes etc complete all as specified and directed at site for the one 3/5 pin 15/16 amps socket outlet independent & Geyser point. |
| 24 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed by Engr-in-charge. |
| 25 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed by Engr-in-charge. |
| 26 | Supply & Fix FRP junction boxes for street light fitting to be fitted on pole with necessary clamping including 6A MCB and 3 core flexible copper cable form junction box to light fitting complete all as specified and directed by Engineer in charge. |
| 27 | S & F 1 sq mm 3 core flexible copper conductor PVC insulater FRLS outer sheathed cable for coneection of street light from junction box,1100 Volt grade cable with stranded copper conductor cable all as specified and directed by Engineer-in-Charge. |
| 28 | S &F Bracket made of GI pipe medium grade 50mm dia 90cm longfor fixing of street light with and including clamps, nuts, bolts, washer complete accessories and applying two coat of oil painting over one coat of zinc chromate primer all as specified and as directed. |
| 29 | M&L for Earthing complete with copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. |
| 30 | M & L for Copper strip roof and down conductor/ buried in ground of size 20 x 3.15mm thick fixed on insulators/ saddles of suitable size all as specified and as directed. |
| 31 | MINICOYM&L Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sqmm nominal cross-sectional area, single core, PVC insulated and sheathed FRLS cable 1100 volts grade, ISI-694 marked including heavy duty non metallic rigid PVC conduit and conduit accessories concealed in wall/roof/floor etc. ISI marked including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) including PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core F.R.L.S cable as earth continuity conductor to common earth and connecting to earth dolly and cutting chases for steel conduits/boxes etc complete all as specified and directed at site for one light/Bell point controlled by one 5/6 amps one way switch. |
| 32 | All as per item No 25 above but for one ceiling fan point controlled by one 5/6 amps one way switch all as specified and directed. |
| 33 | All as per item No 25 above but for one exhaust fan point controlled by one 5/6 amps one way switch all as specified and directed. |
| 34 | All as per item No 25 above but for one socket outlet, three/five pin, 5 Amp, independent controlled by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin all as specified and directed. |
| 35 | Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 2.5 Sqmm nominal cross-sectional area, single core, PVC insulated and sheathed FRLS cable 1100 volts grade, ISI-694 marked including heavy duty non metallic rigid PVC conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket), including PVC insulated multi-stranded copper conductor 2.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly and cutting chases for steel conduits/boxes etc complete all as specified and directed at site for the one 3/5 pin 15/16 amps socket outlet independent & Geyser point. |
| 36 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed by Engr-in-charge. |
| 37 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed by Engr-in-charge. |
| 38 | Supply & Fix FRP junction boxes for street light fitting to be fitted on pole with necessary clamping including 6A MCB and 3 core flexible copper cable form junction box to light fitting complete all as specified and directed by Engineer in charge. |
| 39 | S & F 1 sq mm 3 core flexible copper conductor PVC insulator FRLS outer sheathed cable for connection of street light from junction box,1100 Volt grade cable with stranded copper conductor cable all as specified and directed by Engineer-in-Charge. |
| 40 | S &F Bracket made of GI pipe medium grade 50mm dia 90cm longfor fixing of street light with and including clamps, nuts, bolts, washer complete accessories and applying two coat of oil painting over one coat of zinc chromate primer all as specified and as directed. |
| 41 | Earthing complete with galvanised galvanised steel plate electrode of size 60cm x 60cm x 6 mm thick, buried vertically in a earth pit not less than 2.25 metre deep below ground level with top edge of plate not less than 1.5 metre below normal ground level surrounded by mixture of charcoal and common salt and electrode connected to and including GI wire of 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel, and earth strip protected by GI protection pipe light grade 20 mm bore connected to main earth lead on control panel board and GI pipe light grade 20mm bore for watering, funnel with wire mesh. PCC chamber in PCC 1:3:6 type C-1,40mm thick precast RCC 1:2:4 type B1 (Design Mix) cover reinforced with 8mm dia TMT bars @ 10cm C/C on both sides and handle complete Excavation and earth work in any type of soil and removal up to 50M complete all as specified and shown in electrical plate No:3 of SSR-I (2009) connecting to earth test point on completion. |
| 42 | M&L for Earthing complete with copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. |
| 43 | M & L for Copper strip roof and down conductor/ buried in ground of size 20 x 3.15mm thick fixed on insulators/ saddles of suitable size all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 37 daysJan 04, 2027
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 44 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender