Tender For Rep/Repl Of Monitoring Panel And Lighting ,Fittings & Fixtures Incl Submain Wiring, Point Wiring In Water Supply Installations In Zone A And Rep/Repl Of Lt Switch Gear, Ug Cables And Connected Items Under Ge(I) Gos
Tender Overview
Project Description
Tender for Rep/Repl Of Monitoring Panel And Lighting ,Fittings & Fixtures Incl Submain Wiring, Point Wiring In Water Supply Installations In Zone A And Rep/Repl Of Lt Switch Gear, Ug Cables And Connected Items Under Ge(I) Gos
BOQ
| Sl. No. | Item Description |
| 1 | List of works |
| 2 | Taking down carefully copper/aluminum point wiring (light, fan/exhaust fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders, brackets, bulk head fittings etc removing material to store for keeping in safe custody or for taking credit ( credit for above items should be made as per conditions separately ) and also making good disturbed surfaces of wall, floors etc all as specified and as directed by the Engineer-in-Charge. |
| 3 | M&L for point wiring with 1.5 Sqmm copper conductor (Multi-stranded) PVC insulated and unsheating FRLS electric cable 1100 volts cable and including concealed in PVC conduit 20 mm dia ISI marked or suitable size (as per conductor run) with all fittings/ accessories and including PVC insulated electric cable 1100 volts 1.5 Sqmm ( multi-stranded) copper conductor single core( Green colour) cable as continuous earth wire connected to common earth dolly by providing lugs including sunk in pressed steel terminal boxes of 1.6 mm thick concealed in wall (duly painted with two coats of black bituminous paint over a coat of red oxide primer in and out sides) with and including cutting holes for switches, sockets, regulators etc as per requirement including fixing with machine screw, washer etc for one light point/bell point etc controlled by one, one way switch complete and making good the disturbed surfaces with cement work/putty as per existing including colour/white wash/distemper to match with existing same all as specified and as directed by the Engineer-in-Charge. (a) One light point controlled by one, one way switch |
| 4 | All as per item no 3 but for One fan/exhaust fan point controlled by one, one way switch |
| 5 | All as per item no 3 but for One 5 Amp socket point controlled by one way switch on same board. |
| 6 | All as per serial item No 3 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge. |
| 7 | S&F modular socket outlet 6A 2/3 pin combined 2 module complete all as specified and directed. |
| 8 | S&F modular switch 16A single pole one way complete all as specified and directed. |
| 9 | S&F modular socket outlet 6A/16A- 2/3 pin combined 2 module complete all as specified and directed. |
| 10 | S&F modular switch single pole 1 way 6A, complete all as specified and directed. |
| 11 | M&L for modular Bell push Switch single pole one way 6A/10Amps complete all as specified and directed. |
| 12 | M&L for call bell AC 230 volt single pole complete all as specified and directed. |
| 13 | M&L for modular fan regulator, 120, W-2 module complete all as specified and directed. |
| 14 | Supply and fix Ceiling rose 3 termianl complete all as specified and directed |
| 15 | S&F modular white cover plate with frame for module 3 incl modular metal flush box complete all as specified and as directed |
| 16 | All as per Item no :15 above but for 6 module complete all as specifed and as directed |
| 17 | All as per Item no: 15 above but for 8 module complete all as specifed and as directed |
| 18 | Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 6 Sqmm multi -strand copper conductor drawing in PVC casing caping with 6 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as directed. Note : two run 6sqmm and one run of earth wire 6sqmm and PVC conduit will be measured as one length. |
| 19 | Supply and fix Sheet metal enclosure for AD/DD DB’s suitable for MCBs of single pole and neutral 8 way (Double door) with 200 amp rated bus bar all as specified and directed. |
| 20 | S&F MCB SP up to 40 Amp, 240 volt all as directed. |
| 21 | S&F isolator DP 40 Amp, 240 volt all as directed. |
| 22 | Material and labour for PVC rectangular block of size 25 cmx20cmx5cm depth, closed recessed 3mm thick plastic laminated sheet complete all as specified |
| 23 | Energy efficient LED integrated batten suitable for indoor applications tube light fitting 1x20 Watt 4 FT complete, all as specified and directed. |
| 24 | S&F LED Bulk Head fitting 10 Watt complete all as specified and directed by the Engineer-in-charge. |
| 25 | Supply and fix LED Lamp pin type 9 watt all as specified and directed by the Engineer-In-charge. |
| 26 | material and labour for Lamp holder, PVC/Polycarbonatetype with back plate suitable for batten fittings including connections complete all as specified and directed. |
| 27 | S & F LED light fitting 1 x 10 Watt batten type, indoor decorativealuminium housing and integrated LED driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size incl taking down the old USNV complete all as specified and directed |
| 28 | Supply and fixing Bldg security light fitting LED type 45 Watt new generation in aluminium PDC housing, toughened glasscover with IP 66 protection complete in all respect with GI tubing 25mm/40mm dia, mounting bracket with its clamp incl two coats of synthetic enamel paint over a coat red oxide primer and with all accessories, incl connecting of with 2 run of flexible aluminium/copper conductor of size 1.5 sq mm cable from fitting to junction box/conductor to street light as suitable on site, testing & commissioning complete all as specified and directed. |
| 29 | Supply and fixing Ceiling Fan 1200 mm, sweep star rated with blade, down rod complete all as specified and directed. |
| 30 | Supply and fixing exhaust fan 300 mm sweep, 1400 RPM with louver complete all as specified and directed. |
| 31 | Supply and fixing wall mounted Fan 450 mm, sweep star rated with blade fixed in wall complete all as specified and directed. |
| 32 | Supply and fixing high speed standing Fan ( Farrata Fan ) 450 mm, sweep star rated with blade complete all as specified and directed. |
| 33 | Excavation of trenches in any type of soil n.exc 1.5 M wide and n.exc 1.5 M in depth for taking out/laying of pipe lines and getting out forming bottom surfaces to required gradients complete all as specified and as directed. |
| 34 | Returning, filling in and including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed |
| 35 | Removing excavated surplus materials to a distance not exceeding 50 Mtrs and deposited where directed at a level not exceeding 1.5 Mtr. Above starting point complete all as specified and directed. |
| 36 | Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments. |
| 37 | Supply and laying bricks common burnt clay flyash building bricks laid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and directed. |
| 38 | Supply and Fixing of Change over switch with encloser of capacity 250 Amp ,3 Phase ,4 Pole complete including taking out of old /burn U/S changeover.complete all as specified . |
| 39 | Supply and Fixing of Change over switch with encloser of capacity 200 Amp ,3 Phase ,4 Pole complete including taking out of old /burn U/S changeover.complete all as specified . |
| 40 | Taking out old UNSV and Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for 10 Sqmm 4 Core, including taking down old, complete all as specified and directed. |
| 41 | All as per item No 40 above, but 16 Sqmm 4 Core. |
| 42 | Supply and Fix stainless Steel nut and bolt 10 mm to 16 mm ,40 mm long complete all as specified and as directed |
| 43 | Supply only copper lugs 10 to 35 sqmm for existing panel board complete all as specified and as directed |
| 44 | Supply and fix Gland rope of size 10 mm to 15 mm for various motor and sluce valve complete all as specified and as directed |
| 45 | Supply and replacement contactor 6 to 15 amps capacity , AC 3 phase 415 Volts, 50 HZ |
| 46 | Supply and fix double wall corrugated HDPE pipe 50mm outer dia for protection of UG cable complete all as specified and directed |
| 47 | Supply and fix in replacement of MCCB 4 pole , 415 V , fixed type 125 Amp panel mounting type ,with breaking capacity 16 KA AC |
| 48 | Supply and fix in replacement of MCCB 4 pole , 415 V , fixed type 63 Amp panel mounting type ,with breaking capacity 16 KA AC |
| 49 | Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 Metres below normal ground level, connecting to the Galvanised iron earth lead wire 4mm dia, by means of bolts, nuts, check nuts and washers of galvanised iron and 4mm earth lead protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of 75x50x6mm phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR-2009 Part-I and connecting to earth test point including testing on completion all as specified and directed by the Engineer-in-charge. |
| 50 | Writing of pump sets specification on surface/wall of pump house with white synthetic enamelled paint on black background entire satisfaction of Engineer-In-Charge complete all as specified. |
| 51 | Dismantling U/S waste water tray of pumpsets S&F new stainless steel tray any size and make including GI pipe 15 mm with fittings complete all as specified and directed.Note : GI pipe 10mtr including in the unit rate quoted. |
| 52 | Attending complaint of water supply installation of Cleaning and dusting of all equipments including first hand minor repairs such as as fixing of gland, replacement of packings, repair of electric junction connection etc, complete all as specified and directed . |
| 53 | M&L for painting of Pump sets, contol valves,suction and delivery pipe line and control panel of water supply installation complete all as specified and directed by Engr-in-Charge |
| 54 | Material and labour for chart/ poster/ diagram / name plate etc made out of Aluminium sheet 3mm thicknes with perpex sheet 2 mm thick, cut to size and shape with colour background and diagram and letters including 1X 20W LED fitting and fixing arrangement with screws / adhesives as required complete all as specified and directed by Engineer in charge.Note: The content and size of chart/ poster /diagram / name plate etc shall be given by the Engr in charge during execution of work. |
| 55 | Cutting wild grass, bushes, creaper, unwanted vegitation from inside / surrounding of installations including cutting creapers from barbed / cattle fencing of the installations as when directed and removing of unwanted material from installation compound and depositing where directed.Note :a) The item shall be operated maximum four times in entire period of contract in the same installations. (Area measured separately each time). |
| 56 | Repair/Replacement of Detoriated motor protection covers of 25 to 30 HP motor complete all as specified. |
| 57 | All as per item No 56 above, but 15 to 20 HP. |
| 58 | All as per item No 56 above, but 5 to 10 HP. |
| 59 | Material and labour for fabricating , supplying and installing Retro Reflective sign board, consisting of 5 feet x 4 feet frame for writing made of 25mmx25mm medium grade SS 304 with 3 mm ACP cladding both sides ( ie 3mm ACP + 3mm ACP) glued together for writing on both sides. Writing shall be of Retro reflecting over same sheeting of letter sizes not less than 75mm and to be adjusted all as per site requirement and direction of Engr-in-Charge. ACP cladding shall be fixed with frame with riveting or clamping to hold with frame. Board shall be fitted on 50mm dia SS grade 304 legs of length 2.60 M i.e 2 Mtr above ground level and 60 CM embedded in PCC 1:2:4 type B1 block of size 45cmx45cmx60cm including necessary excavation, earthwork and dismantling of old vintage sign board complete for different installation with the name as directed by Engr-in-charge. |
| 60 | Supply and fixing for 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN1.6) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings of size 63 mm fixed complete to walls, ceilings or in floors etc. |
| 61 | Supply and fixing for 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN1.6) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings of size 32 mm fixed complete to walls, ceilings or in floors etc. |
| 62 | Supply and fixing for 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN1.6) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings of size 25 mm fixed complete to walls, ceilings or in floors etc. |
| 63 | Supply and fix PP-R Gate valves of size 63 MM outer dia (brass insert) as per requirement of the site complete all as specified and directed |
| 64 | Supply and fix PP-R Gate valves of size 32 MM outer dia (brass insert) as per requirement of the site complete all as specified and directed |
| 65 | Supply and fix PP-R Gate valves of size 25 MM outer dia (brass insert) as per requirement of the site complete all as specified and directed |
| 66 | Supply and fix bib tap 25 mm dia brass insert complete all as specified and directed |
| 67 | Supply only garden pipe 25 mm dia high quality 100 feet long complete all as specified and directed |
| 68 | S&F ball valves for 20 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed. |
| 69 | Supply Fix in repair PVC tank cover for 500 ltr capacity fixed in position with nuts and bolts complete all as secified and as directed |
| 70 | Supply Fix in repair PVC tank cover for 1000 ltr capacity fixed in position with nuts and bolts complete all as secified and as directed |
| 71 | Supply, installation, testing and commissioning of CPRI approved LT panel board, outdoor type, with front and back door openable type fitted with nuts, bolt and washers fitted with knob and hinges, floor mounted fabricated out of 3.15 mm thick MS sheet to be placed over pedestals in PCC 1:3:6 type C-1 cement concrete extending 300mm above ground level with one meter wide plaform in all round panel LT panel shall be totally enclosed weather proof and verming proof with front and rear opening with IP-54 protection as per IS-8623 duly jpowde coated for connection, RYB, insulator complete pre-wired and cable connection with copper conductor wire upto copper bus bar including all incoming and outgoing cable connection with suitable size of copper lugs/gland complete all as specified and directed by Engr-in Charge and also comprising of the following of suitable size.(i) MCCB 160 A FP, 36 KA Adjustable thermal & Fixed magnetic setting. 1 Nos. (Incoming) (ii) MCCB 63 A FP, 36 KA, Adjustable thermal & Fixed magnetic setting. 2 Nos. (Outgoing) (iii) Alumimium bus bars sleeve insulated 400 amps capacity TPN mounted on epoxy insulators-01 Set(iv) LED KWH meter, 3 Phase, 0-60 A with CTs- 01 No(v) Digital voltmeter 0 - 500 V range with selector switch - 01 No(vi) Digital ammeter 0 - 200 A range with selector switch and CTs - 01 No(vii) Indicators RYB - 01 Set(viii) Internal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses.(ix) Cable entry glands and two nos earthing terminals(x) Fabrication of LT panel board with all accessories except above and complete painting. Angle iron support made out of 50 x 50 x 6MM thick(xi) Cost of PCC, eraction incl commission etc complete |
| 72 | Material and labour for remove unserviceable old panel board from water supply instalation and deposit to AGE E/M store yard |
| 73 | Taking up or down XLPE cable with connections for detecting the fault and after repair relaying the same complete, all as specified and directed. Note :- Measurement for excavation, returning, removing, sand and brick will be measured and paid at appropriate items of this sechdule. |
| 74 | S&F in repairs HRFR PVC insulated industrial cabled single core copper conductor, 1100 volts conforming to IS 694 of size 16 Sqmm complete all as specified and directed |
| 75 | S&F in repairs HRFR PVC insulated industrial cabled single core copper conductor, 1100 volts conforming to IS 694 of size 10 Sqmm complete all as specified and directed |
| 76 | S&F in repairs aluminium busbar of suitable size as per exisiting on ground and removing the old burnt one from LT panel with complete connection of existing cables all as specified and directed. |
| 77 | M&L for attending day to day breakdown complaints of any nature in low tension line after receiving the complaint from complaint cell/ JE concerned and rectifying the same as soon as possible complete all as specified and directed. |
| 78 | Supply and fixing in repairs SP 5-32 amp rating 240V, 10KA 'C' curveminiature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 79 | Supply and fixing in repairs SPN 32-40 amp rating 240V, 10KA 'C' curveminiature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 80 | Supply and fixing in repairs TPN 40-100 rating 415, 10KA 'C' curveminiature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 81 | S&F in replacement of Cable end jointing kit for 1.1 KV (Earthed) grade cable for End heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm complete |
| 82 | S&F in replacement of Cable end jointing kit for 1.1 KV (Earthed) grade cable for End heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 150 to 185 sqmm complete |
| 83 | S&F in replacement of Cable end jointing kit for 1.1 KV (Earthed) grade cable for End heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 240 to 300 sqmm complete |
| 84 | S&F in replacement of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 2 core XLPE armoured aluminium conductor cable of size 10-16 sqmm complete |
| 85 | S&F in replacement of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 16-50 sqmm complete |
| 86 | S&F in replacement of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm complete |
| 87 | S&F in replacement of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 150 to 185 sqmm complete |
| 88 | S&F in replacement of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 240 to 300 sqmm complete |
| 89 | Boring of holes horizontally for laying of 80mm dia pipe (minimum depth 0.60 Mtr from top level) under road, Pavement, hard standing complete all as specified and directed. |
| 90 | Supply and fixing Aluminium tube terminal/ lugs of undermentioned size complete (a) 10 to 25 Sqmm |
| 91 | All as per item no 90 but for 35 to 50 Sqmm |
| 92 | All as per item no 90 but for 70 to 120 Sqmm |
| 93 | All as per item no 90 but for 150 to 185 Sqmm |
| 94 | All as per item no 90 but for 240 to 300 Sqmm |
| 95 | supply only PVC Electrical insulation self adhesive tape 1.8cmx7mx0.125mm for Red, Yellow, Blue & Green all as specified and directed |
| 96 | Supply, fabricate, erect, test and commission in replacement outdoor LT MS Feeder pillar box totally enclosed weather and vermin proof, suitable verntilated, 440 Volts, 50 HZ, AC Supply, factory made standard design as per electrical requirements to suit power distr sys , enclosure fabricated out of 3.00 mm thick MS sheet, excavation and earth work, PCC foundation etc,with hinged doors and lcoking arrangemetn , air vents, tappered roof, incoming and outgoing cable connections from bottom with compressed cable gland etc as required with and including the following, supplied fitted and connected internally complete 04 Nos aluminium bus bar of size 50 x 10 mm with PVC coloured heat srinkable type sleeves continous phase rating 400 Amps rating mounted on non cracting resin type insulators complete all as specified |
| 97 | S & F in replacement of old UNSV. Cable loop box with SMC Junction box shock and rust proof , rot/termite resistance, tamper proof, with necessary pole mounting arrangements FR type ( (270mm x 225mm x 135mm) with in-built /housed terminal for 04 pole wire termination and 6AMCB din-rail mounted , hinged door with locking arrangements incl necessary Galvanised iron clamps, bolts/nuts suitable to hold/accommodate to the exisitng pole(any type)/ bldg etc by removing the exisiting electrical connections and reconnecting back the same cable complete all as specified & directed Make: Sintex/Hensel (Note : any glands/lugs/lock-pads reqd for the same is within the the rates quoted) |
| 98 | Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr depth and getting out in looses/soft soil complete all as specified |
| 99 | Returing filling in incl spreading leveling, watering and well ramming in layer not less than 25 cum each layer all as specified. |
| 100 | Removing excavated material to a distance not exc 50M and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified |
| 101 | Supply and laying double wall corrugated (DWC) HDPE pipe 50 mm outer dia for protection of UG cable as per IS: 16205 (part 24) of 2017 complete all as specified. |
| 102 | Supply and laying double wall corrugated (DWC) HDPE pipe 63 mm outer dia for protection of UG cable as per IS: 16205 (part 24) of 2017 complete all as specified. |
| 103 | Supply and laying double wall corrugated (DWC) HDPE pipe 90 mm outer dia for protection of UG cable as per IS: 16205 (part 24) of 2017 complete all as specified |
| 104 | M & L for tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 50 mm bore including removing the rusted old one complete all as specified and directed. |
| 105 | M & L for tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 80 mm bore including removing the rusted old one complete all as specified and directed. |
| 106 | M & L for tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 100 mm bore including removing the rusted old one complete all as specified and directed. |
| 107 | Taking out old unserviceable PCC/steel tubular pole 9 mtrs long and supply and fixing steel tubular swaged poles with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and erecting in position all as specified and directed with shifting of conductors and insulators including painting the exposed portion with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer with and including marking of pole number with black paint in yellow circle, complete, all as specified and directed. |
| 108 | Taking out old usserviceable PCC pole of any size and supply and fixing in repairs Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and l02mm x 279mm at bottom, class 10 and erecting in position all as specified and directed with shifting of conductors and insulators including painting the exposed portion with two coats of weather proof paint complete, all as specified and directed. |
| 109 | S & F in replacement of Cross arm, bracings, supports , clamps and back plate fabricated from structural steel section, including nut , bolts , washers, welding , bendings cold or hot, drilling hole for both in any shape or size as indicated or directed and inclusive of one prime coat, one under coat and one finishing coat of paint incl taking down the old unserviceable cross arms complete all as directed. |
| 110 | M & L stay assembly complete with accessories as shown in electrical plate No 1 (Loop type insulator, stay clamps, excavation and concrete only measured separately) using diameter of stay rod 16 mm and MS stay plate 230mm x 230mm including taking down complete all as directed. |
| 111 | Supply and fix in replacement of loop type insulator vitreous white,brown or green insulator small size,with over all dimensions 65 x 90 mm,clearance of hole 16 mm complete all as directed. |
| 112 | Taking out old UNSV and Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes, including taking down old, complete, all as specified and directed :-(a)10 Sqmm 2 Core |
| 113 | All as per item no 112 but for 16 Sqmm 2 Core. |
| 114 | All as per item no 112 but for 16 Sqmm 4 Core. |
| 115 | All as per item no 112 but for 25 Sqmm 3.5 Core. |
| 116 | All as per item no 112 but for 35 Sqmm 3.5 Core |
| 117 | All as per item no 112 but for 50 Sqmm 3.5 Core |
| 118 | All as per item no 112 but for 70 Sqmm 3.5 Core |
| 119 | All as per item no 112 but for 95 Sqmm 3.5 Core |
| 120 | M/L for replacement of Earthing complete with GI earth plate 60x60cmx6mm thick electrode and using galvanised iron strip 32 x 6 mm as earthing lead burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia med grade,funnel,wire mesh,protection pipe 40 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point all as specified and as directed by Engr-in-charge. |
| 121 | S&F in replacement of moulded case circuit breaker Four pole 63/100 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 122 | S&F in replacement of moulded case circuit breaker Four pole 160 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 123 | S&F in replacement of moulded case circuit breaker Four pole 200 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 124 | S&F in replacement of moulded case circuit breaker Four pole 250 Amps 36 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 125 | S&F in replacement of moulded case circuit breaker Four pole 400 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 126 | S&F in replacement of moulded case circuit breaker Four pole 630 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 127 | S&F in replacement of digital voltmeter 0 to 500 volts 96 x96mm flush type in LT Panels incl taking out the old unserviceable complete all as specified and directed. |
| 128 | S&F in replacement of digital ammeter range as per existing 96 x96mm flush type in LT panels incl taking out the old unserviceable complete all as specified and directed. |
| 129 | S&F in replacement selector switch of voltmeter/ammeter in LT panel boards incl taking out the old unserviceable complete all as specified and directed. |
| 130 | S&F in replacement indicator assembly (RYB) LED type in LT panel boards incl taking out the old unserviceable complete all as specified and directed. |
| 131 | M&L for painting steel tubular/RS joist pole 9 mtrs long alongwith bends with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer with and including marking of pole number with black paint in yellow circle, complete, all as specified and directed. |
| 132 | M&L for painting to LT panels of any size with two coats of sky blue paint over a coat of red oxide primer outerside and two coats of off white paint over a coat of red oxide primer internally complete all as specified and directed by Engr- in-Charge. Note: 1. Before painting the contractor will ask for a shut down of the recpective feeder from the JE. 2. While painting of the panels protection of MCCB's and MCB's to be taken care of by the contractor. Any damage occured during the painting will be bear by the contractor. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender