Tender For construction Of Smqs At Af Stn Darbhanga
Tender Value
13.30 Crore
Estimated cost
Bid Submission
24 Dec 2026
32 days left
EMD
9.90 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Darbhanga → Bihar
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for construction Of Smqs At Af Stn Darbhanga
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE A PART I (BUILDING WORKS) |
| 2 | Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ Part I . |
| 3 | SCHEDULE A PART II (INTERNAL WATER SUPPLY) |
| 4 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Sch ‘A’ Part II. |
| 5 | SCHEDULE A PART III (INTERNAL ELECTRIFICATIONS) |
| 6 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONS as listed in Sch ‘A’ Part III. |
| 7 | SCHEDULE A PART IV (EXTERNAL WATER SUPPLY) |
| 8 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Sch ‘A’ Part IV . |
| 9 | SCHEDULE A PART V (EXTERNAL ELECTRIC SUPPLY) |
| 10 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIC SUPPLY as listed in Sch ‘A’ Part V |
| 11 | SCHEDULE A PART VI (SEWAGE DISPOSAL) |
| 12 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL as listed in Sch ‘A’ Part VI |
| 13 | SCHEDULE A PART VII (AREA DRAINAGE) |
| 14 | Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Sch ‘A’ Part VII |
| 15 | SCHEDULE A PART- VIII (ROAD/PATH/CULVERT/HARD STANDING) |
| 16 | Lump sum price worked out by the contractor for ROAD/PATH/ CULVERT / HARDSTANDING as listed in Sch ‘A’ Part VIII |
| 17 | SCHEDULE A PART- IX (EARTHWORK, SITE CLEARANCE AND DEVELOPMENT) |
| 18 | Lump sum price worked out by the contractor for EARTHWORK, SITE CLEARANCE AND DEVELOPMENT as listed in Sch ‘A’ Part X |
| 19 | SCHEDULE A PART- X (DEMOILTION AND DISMANTLING) |
| 20 | Lump sum price worked out by the contractor for Demoilition and Dismanting as listed in Sch ‘A’ Part X |
| 21 | SCHEDULE A PART- XI (FIRE FIGHTING) |
| 22 | Lump sum price worked out by the contractor for Fire fighting as listed in Sch ‘A’ Part XI |
| 23 | SCHEDULE A PART- XII (LIGHTIENING PROTECTION ) |
| 24 | Lump sum price worked out by the contractor for LIGHTENING PROTECTION as listed in Sch ‘A’ Part XII |
| 25 | SCHEDULE A PART- XIII (LIFT AND DG SET ) |
| 26 | Lump sum price worked out by the contractor for LIFT AND DG SET as listed in Sch ‘A’ Part XII |
| 27 | SCH \\"A\\" PART XIV (BARRICATING WORK) |
| 28 | Lump sum price worked out by the contractor for BARRICATING WORK as listed in Sch ‘A’ Part XIV |
| 29 | SCH \\"A\\" PART XV (TYRE WASHING POINT) |
| 30 | Lump sum price worked out by the contractor for TYRE WASHING POINT listed in Sch ‘A’ Part XV |
| 31 | SCH \\"A\\" PART XVII(MISCELLENEOUS B/R AND E/M ITEMS) |
| 32 | Supply erection, testing and commissioning of gun metal air release valve 50 mm dia complete |
| 33 | S&F PVC connection pipe heavy duty, hot and cold, 15 mm dia, 450 mm long, metal cladded, with brass adopter & washer on both sides complete all as specified and directed. |
| 34 | M&L for construction of RCC Septic tank designed to carry sewage and sludge water, excavation in any type of soft/loose soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in walls, Base slab, Baffle walls and Roof Slab including beam etc with Vent shaft, manhole openings with connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 Users, complete all as specified. |
| 35 | M&L for construction of 3M dia x 4.50M effective depth of Soakage wells excavation, in any type of soft/loose soil, foundation in PCC 1:3:6 walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M25/SFRC Cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size, complete all as specified. |
| 36 | M&L for construction of block masonry valve pit chamber of size 600x600x600mm (internal dimensions) with 50 mm thick foundation using PCC 1:3:6 (type D-2), block masonry wall built in CM 1:4, 15mm thick internal plaster including top of floor in CM 1:4, finished even and smooth without using extra cement, and 20mm thick external plaster in CM (1:4) and 3.15mm thick MS sheet cover including 40x40x6mm MS angle frame fixed in PCC 1:2:4 type B-1 coping with 25x4mm flat iron hinges, hold fasts, handles, locking arrangements, applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer to all steel surface including excavation and earth work in any type of soil complete, as specified and as directed. |
| 37 | Supply, Install and testing Self priming Pressure pumps for 230 V, single Phase, 50 Hz , with pure copper winding having maximum lifting height of 30m and maximun flow rate 3300 Liters per hour complete all as specified and directed. |
| 38 | Supply and install LT motor control panel floor mounting type fabricated from 3.0 mm thick CRCA sheet, dust and vermin proof complete with aluminium bus bar 200 Amp and with following accessories:-(a) MCCB TPN 63 Amps 25 KA as incoming -1 No(b) MCB TP 20-32 Amps - 1 Nos(c) MCB SPN 16 Amps - 1 No(d) Combo digital volt meter and Ammeter with CTs 0-500 volt and selector switch(e) 1 Nos Star Delta starter of capacity up to 7.5 HP with SPP and overload relay(f) LED Phase indicating lamps R, Y, B - 1 Set |
| 39 | Supply and fixing single master and 8 way salve for talk back system complete all as specified and as directed by the engineer in charge |
| 40 | Supply, install, commissioning and testing of analog addressable type active loop repeator panel with inbuilt turbo isolator, LCD display 6x40 charactors display having controls for reset, mute, accept, silence alarm and self test with programmable free keys includingcommunication with three fire alarm panel in each building |
| 41 | S&F wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours (2 Nos at each floor G+5) |
| 42 | Supply installation testing and commissioning of 2W MultiTap (0.25W; 0.5W; 1W; 2W), Ceiling Mount Speakers. The speakers shall be of same make as that of the Control Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms. The speaker shall be UL lsited. MAKE: NOTIFIER/HONEYWELL/EDWARDS/SIEMENS |
| 43 | Supply, installation , testing and commissiong factory made LT Panel outdoor type platform mounted of size 1800 mm x1200 mm x 450 mm suitable for 415 Volts 3 phase 4 wire system 50Hz supply having aluminum bus bar 600 Amps for phases and neutral, installed on porcelain / epoxy insulator. the panel shall be dust proof, vermin proof (IP54) and applying spray paintig with two coats of synthetic enameled paint over a coat of red oxide primer on sheet and made of out of 3.15 mm thick CRCA sheet self moulded type and 50x50x6 mm angle iron frame front and rear opening with double shutter and locking arranement with 50mm lock and including grouting of panel with necessary PCC 1:2:4 type B-1 work complete all as specified. The scope of work includes provision of housing the following acceessories:-INCOMING(i) MCCB having current rating 400 Amp, 4 pole of breaking capacity 36 KA -01 No.(ii) Volt meter 0-500 Volts,Square flush pattern,digital type -01 No.(iii) Amp meter square flush pattern 0-600 Amps digital type-01 No.(iv) Indicating lamp LED type one set in incoming phases.(v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 volts grade IS 694 marked .(vi) On-load Change over switch,415 V, 400 amps, TPN version -01 No. |
| 44 | OUTGOING(i) MCCB having current rating 250 Amp. 4 pole of breaking capacity 25 KA -02 Nos. (ii) MCCB having current rating 200 Amp. 4 pole of breaking capacity 25 KA -02 Nos.(iii) MCCB having current rating 100 Amp. 4 pole of breaking capacity 25 KA -02 Nos.(iv) MCCB having current rating 63 Amp. 4 pole of breaking capacity 25 KA -02 Nos.(v) MCB TPN having current rating 20 Amp. 4 pole of breaking capacity 16 KA -02 Nos.(vi) Provn of Space for MCCB -01 No |
| 45 | Supply, installation , testing and commissiong factory made LT feeder pillar box outdoor type platform mounted of size 1200 mm x1000 mm x 450 mm suitable for 415 Volts 3 phase 4 wire system 50Hz supply having aluminum bus bar 400 Amps for phases and neutral, installed on porcelain / epoxy insulator. the panel shall be dust proof, vermin proof (IP54) and applying spray paintig with two coats of synthetic enameled paint over a coat of red oxide primer on sheet and made of out of 3.15 mm thick CRCA sheet self moulded type and 50x50x6 mm angle iron frame front and rear opening with double shutter and locking arranement with 50mm lock and including grouting of panel with necessary PCC 1:2:4 type B-1 work complete all as specified. The scope of work includes provision of housing the following acceessories:- |
| 46 | INCOMING(i) MCCB having current rating 250 Amp. 4 pole of breaking capacity 25 KA -01 No. (ii) Volt meter 0-500 Volts,Square flush pattern,digital type -01 No.(iii) Amp meter square flush pattern 0-600 Amps digital type-01 No. (iv) Indicating lamp LED type one set in incoming phases. (v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 volts grade IS 694 marked . |
| 47 | OUTGOING(i) MCCB having current rating 100 Amp. 4 pole of breaking capacity 25 KA -01 Nos. (ii) MCB TPN having current rating 20 Amp. 4 pole of breaking capacity 16 KA -01 Nos. (iii) Time switch, 415 V, 20 Amps with contactor-01 No. (iv) MCCB having current rating 40 Amp. 4 pole of breaking capacity 16 KA -02 Nos. (v) MCCB having current rating 32 Amp. 4 pole of breaking capacity 16 KA -01 Nos. (vi) Volt Meter 0-500 with selector switch -01 No(vii) Amp Meter 0-200 with CT and selector switch -01 No. (viii) Indicating lamp -01 Set (LED). (ix) Provn of Space for MCCB -01 No |
| 48 | Supply and Fixing Aviation obstruction light for High-rise building complete |
| 49 | Supply installation , commissining and testing of wall mounted VTPN DB 12 awy with 250 Amp copper bus bar fully insulated for each phase and shrouted neutral bar, IP-54 protection with 250 Apm MCCB as incomer and SP/TP MCB AS OUTGOING ALONGWITH ELECTRICAL accesseries all as specified and directed. |
| 50 | Supply, installation, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 62.5 KVA, a prime mover rating at 0.85 load factor as per clause 13.2.2 pf ISO-8528 (Part-I), water cooled, 415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum for automatic starting on main failure. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet , outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Darbhanga (Bihar) (Capacity of Engine, alternators shall be worked out taking all de-rating factors into consideration) including PCC foundation( of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB guidelines and Comprising of followings:- |
| 51 | (i) ENGINE: (Prime Mover): Diesel Engine 1500 RPM , direct injection ,multi cylinders ,four stroke, confirming to ISO3046/BS 5514, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 58.4KVA(46.8KW) at outdoor atmospheric conditions at Darbhanga ,(Taking all de-rating factor into consideration), , 12/24 Volt(as per manufacturer recommendations) electric battery start, complete withy fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system(Shut down, High water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc . |
| 52 | (ii) ALTERNATOR: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 58.4KVA(46.8KW) Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class \\"H\\", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine. |
| 53 | (iii) BASE-PLATE: made out of structural steel as per manufacturers recommended design/specifications. |
| 54 | (iv) AMF CONTROL PANEL: Factory made CPRI Approved cubicle type floor mounted LT Panel board, indoor type made out of MS angle not less than 25X25X5 mm, and 1.6 mm thick MS CRCA sheet, front opening type , protection class IP-54, duly powder coated after seven tank process, with electrolytic grade copper bus bar of 300 Amps capacity for four poles, with all standard switchgear and protection, internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of followings:-(a) MCCB 415 Volts, 315Amp, rating 4 Pole 25 KA rupturing capacity, adjustble type 70% - 100% -2 No with suitable rating HRC back up fuses(b) Digital Ammeter 0-400 amps, 96 mmX96 mm square dial flush type ISI marked with in built selector selector switch 3 way and current transformers 200/5 A -01 Nos(c) Digital Voltmeter 0-500 volts 96 mmX96 mm square dial flush type ISI marked with in built selector switch 3 way -01 set (d) Phase indicating lamps(R-Y-B) -1 set(e) Frequency meter digital type 45 to 55 Hz-1 nos(f) KWH Meter 3 Phase unbalanced load 1200 Amps capacity incl CT Coil -1 Set(g) All standard relays , circuits and protection required for automatic operation of Gen set (h) By pass arrangment of suitable cap(j) Onload Change over switch 100 Amp 4 pole -01 Nos |
| 55 | (V) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and ox, 70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, labeling certification etc as laid down in GSR No 371(E) dt 17 May 2002.. |
| 56 | (VI) Foundation/Plinth/Base shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M |
| 57 | (VII) Diesel storage tank of capacity adequate for storage of diesel for 12 hours operation of Gen Set. |
| 58 | (VIII) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. SCHEDULE ‘A’ PART- I(BUILDING WORK) Srl No Description of items of works Drg No Unit No of units Rate in Rs Amount In Rs |
| 59 | (VIII) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. SCHEDULE ‘A’ PART- I(BUILDING WORK) Srl No Description of items of works Drg No Unit No of units Rate in Rs Amount In Rs |
| 60 | Construction of block of 20 Qtrs with stilt parking, (S+5) and RCC terrace Over Head Tank of 25,000 Ltr capacity with permanent specifications and Griha 3 star rating, complete all as specified and all as shown in drawings. |
| 61 | Construction of semi under ground sump of 10000 Ltr capacity, complete all as specified and all as shown in drawings. NOTES For Serial item No: 1 to 2:-(i) Earth work, excavation including surface excavation, surface dressing, returning filling in, filling under floors as shown in drawings for buildings/structures covered under this schedule is deemed to be included in the lumpsum quoted against each item.(ii) GL shown in the drawing is the existing ground Level.(iii) All earth filling i.e upto GL and from GL to FFL shall be included in the scope of lumpsum and nothing extra shall be paid on this account. Total amount of Schedule ‘A’ Part-I carried over to BOQ Rs 87380000.0 Signature of Contractor AAD (Contracts)For Accepting Officer SCHEDULE ‘A’ PART- II(INTERNAL WATER SUPPLY) Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 62 | S & F galvanised steel water tubes 15mm bore medium grade with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed. |
| 63 | S & F galvanised steel water tubes 20mm bore medium grade with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed. |
| 64 | S & F Gun metal gate valves with iron wheel head, screwed both ends for iron pipe and fixed 20 mm bore complete all as specified and directed. |
| 65 | S & F angle cock 15 mm bore , cast copper alloy, chromium plated, quarter turn, fancy with cup concealed type serewed both ends for iron pipes or brass ferrule or fixed to CPVC pipes including all necessary fittings complete all as specified and directed. |
| 66 | S & F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 67 | S & F pillar taps 15mm bore , cast copper alloy fancy type with capstan heads, chromium plated, quarter turn, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 68 | S & F bib taps 15mm bore chromium plated, cast copper alloy, fancy, quarter turn, with cup concealed type long shank, with capstan head screwed down, screwed for iron pipe or brass ferrule complete fixed to CPVC/ GI pipes including all necessary fittings all as specified and directed. |
| 69 | S & F CP mixture for mixing hot and cold water screwed of 15 mm bore chromium plated cast copper alloy with capstan heads, screwed down high pressure with or with out shanks and fly nuts scrwed for iron pipe or for brass ferrule etc complete all as specified and directed. |
| 70 | S & F CP health faucet (ABS body) stainless steel chromium plated uitable for 15 mm bore dia pipe with 1.25 mtr long flexible tube and ABS wall hook including making connection and fixed in position, complet all as speciefied and directed. Total amount of Schedule ‘A’ Part-II carried over to BOQ Rs 424676.6 Signature of Contractor AAD (Contracts)For Accepting Officer SCHEDULE ‘A’ PART- IIIINTERNAL ELECTRIFICATION Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 71 | Material and labour for point wiring with two single core 2.5 Sqmm cable (nominal area) stranded FRLSH copper conductor, PVC insulated unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm dia with modular metal flush box, 1.6 mm thick of suitable size and modular white cover plate with frame of suitable module upto 1Module to 12 Module and wiring to be terminated in pressed steel sunken boxes including all accessories and using single core 2.5 Sqmm (nominal area) stranded copper conductor, PVC insulated unsheathed cable as in earth wire (green colour) connected to common earth dolly complete all as specified and directed for following :- |
| 72 | (a) One light, fan, bell point controlled by one switch. |
| 73 | (b) One 3 pin switch socket outlet point 5 Amps on same board with other switch. |
| 74 | (c) One 3 pin switch socket outlet point 5 Amps on Independent board with other switch. |
| 75 | (d) One light / fan point controlled by two Nos two way switch. |
| 76 | € One 3 pin socket out let 15 mm on independent board |
| 77 | M&L for Modular switch 1 way 6A, 1 module, flush button single pole, one way, complete as specified and directed. |
| 78 | M&L for Modular switch, 6 Amps, one module, two way complete all as specified and directed. |
| 79 | M&L for Modular socket outlet 2/3 pin combined 2 module, 6 Amps, 230 Volts 50 hz AC circuit complete all as specified and directed. |
| 80 | M&L for Modular socket outlet 2in1, 6 pins 6A and 16A, combined 2 module, complete all as specified and directed. |
| 81 | M&L for Modular switch 1 way16A,1module, flush button single pole, one way, complete as specified and directed. |
| 82 | S & F ceiling rose surface backlite 65x50mm 3 terminals complete all as specified and directed. |
| 83 | Supply and fixing Batten holder PVC body with back plate complete including 10 watt LED bulb cool day light,B22 base complete all as specified and directed. |
| 84 | S&F Modular Fan step regulator, 120W - 2 module complete all as specified and directed. |
| 85 | M&L for Modular bell push 5 Amps 230 V, AC circuit complete all as specified and directed. |
| 86 | M&L for call bell ding dong 230 V AC circuit complete all as specified and directed. |
| 87 | Supply and fixing 15 A socket on 2 module Modular sunken box including back and front cover plate for fixing of AC / Geyser controlled by 20 Amp modular MCB 1 module plate 1.2 mtr height of Ground level and For Geyser 15A socket provided in bathroom in 2Module metal box along with cover plate and controll MCB 20 Amps of 1Module for the same is provided outside bathroom in light board complet The wire used for the same shall be measured and paid sepaerately in submain items. (AC / Geyser) |
| 88 | Supply and fixing PVC LED batten lights fitting 1x 20W, 220V, colour Temperatur 6000 to 6500 K,PF>0.95,CRI>75,and THD<10,230 volts AC 50Hz with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 89 | Supply and fixing PVC LED batten lights fitting 2 feet 1x 10W, 220V, colour Temperatur 6000 to 6500 K,PF>0.95,CRI>75,and THD<10,230 volts AC 50Hz with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 90 | Supply and fixing LED Light fitting 1x9/10 watt bulk head luminaire including LED light driver holder,220V, colour Temperatur 6000 to 6500 K,PF>0.95,CRI>75,and THD<10,230 volts AC 50Hz with driver, holder including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 91 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant,220V, colour Temperatur 6000 to 6500 K,PF>0.95,CRI>75,and THD<10,230 volts AC 50Hz with driver, holder including complete with driver, GI lamp bracket minimum 1 mtr length with impact of 40mm dia and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 92 | Supply and fixing factory made epoxy powder coated distribution board SPN 16 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, stranded DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed. |
| 93 | Supply and fixing factory made epoxy powder coated distribution board E-TPN 8 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, stranded DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed. |
| 94 | Supply and fixing RCBOs DP, 25Amps,earth leakage and short circuit protection sensivity 100mA, 230 volts complete all as specified and directed . |
| 95 | Supply and fixing RCBOs FP,25 Amps,earth leakage and short circuit protection sensivity 100mA, 415 volts complete all as specified and directed . |
| 96 | Supply and fixing MCB single pole 240 volt 'C' curve 10 KA 6 to 32 Amps capacity all as specified and directed. |
| 97 | M&L for concealed sub main wiring using 2x4 sqmm PVC insulated, unsheathed stranded copper conductor cable of size 4.0 Sqmm of voltage rating up to and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sqmm (green colour) as earth continuity conductor all as specified and directed. (Note : 02 runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)(For AC / Geyser) |
| 98 | M&L for concealed sub main wiring using 2x6 sqmm PVC insulated, unsheathed stranded copper conductor cable of size 6.0 Sqmm of voltage rating up to and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6.0 Sqmm (green colour) as earth continuity conductor all as specified and directed. (Note : 02 runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)(From Main DB to SPN DB) |
| 99 | M&L for concealed sub main wiring using 2x2.5 sqmm PVC insulated, unsheathed stranded copper conductor cable of size 2.5 Sqmm of voltage rating up to and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 2.50 Sqmm (green colour) as earth continuity conductor all as specified and directed. (Note : 02 runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)(For Inverter / DB SPN wiring) |
| 100 | Supply and fix exhaust fan 5 star rating made of steel body complete with louvers shutters , 300 mm sweep, single phase, 230 Volts AC,1200 RPM, ISI marked fixed properly at directed location with provisioning of suitable fixing/tightening arrangements and connecting/testing and including writing MES No complete all as specified and directed, |
| 101 | Supply and fix exhaust fan 5 star rating made of sturdy Engineering plastic complete with louvers shutters , 250 mm sweep, single phase, 230 Volts AC,1200 RPM, ISI marked fixed properly at directed location with provisioning of suitable fixing/tightening arrangements and connecting/testing and including writing MES No complete all as specified and directed, |
| 102 | Supply and fix Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.of size 32 mm dia all as specified and directed. |
| 103 | Supply & Fixing ceiling fan 1200 mm sweep, BEE 5 star rated, ceiling fan with remote control with Brush less direct current (BLDC) motor, class of insulation : B, 3 Nos blades, 30 cm long down rod, 2 Nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service Value ( CMM/W) minimum 6.00, Air delivery minimum 210 CMM 350 RPM ( tolerance as per IS : 374 - 2019), THD less than 10%, compatible for regulator for speed control and all remaining accessories including safety pin, nut, bolts & washers, temperature rise = 75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc including necessary connection with ceiling rose with 3 core 1.0 Sqmm PVC insulated round flexible cable and including writing MES No all as specified and directed. |
| 104 | Supply and fix water heater storage vertical typewith digital control , puff insulation type of 25 ltrs capacity and 2000 watts, BEE Star rated-5, with glass line inner shell with Hot & Cold pipe, water connection pipe, electric connection and necessary fixing arrangement and including writing MES No complete all as specified and directed. |
| 105 | S&F Single Phase Smart pre paid meter confirming IS 16444-2015 Refirmed 2020,of capacity 10 to 60 Amps,class of accuracy 1.0% complete all as specified Total amount of Schedule ‘A’ Part-III carried over to BOQ Rs 3499224.09 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- IVEXTERNAL WATER SUPPLY Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 106 | Supply and fixed Gun-metal gate valves with iron wheel head, screwed both ends size 50 mm bore, for iron pipe complete all as specified and directed. |
| 107 | Supply and fixed Gun-metal gate valves with iron wheel head, screwed both ends size 25 mm bore, for iron pipe complete all as specified and directed. |
| 108 | Supply only CI specials/ fittings of any type, radius, angle, tapers, increasing, decreasing sockets, Tee pieces single branch, \\"Y\\" junction, double branch, cross (all sockets and spigot) collars, caps and plugs etc upto 150 mm bore complete. |
| 109 | M&L for Galvanised steel Tubing 50 mm bore, 'Medium grade', with midium grade GI fitting, laid in trenches fixed towall/floor complete all as specified and directed. |
| 110 | M&L for Galvanised steel Tubing 25 mm bore, 'Medium grade', with midium grade GI fitting, laid in trenches fixed towall/floor complete all as specified and directed. Total amount of Schedule ‘A’ Part-IV carried over to BOQ Rs 181759.32 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- VEXTERNAL ELECTRIC SUPPLY Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 111 | Supply and erection of steel tubular swaged pole for 2 pole structure frame , type 410-SP 55 (HT 11.00 mtr long pole) complete conforming to IS: 2713 complete with CI base plate, finial taper plug, pole cap, bolts, nuts and screw complete all as specified and including of following works:-(a) Excavation in trenches as required , returning filling and disposal of surplus soil to a distance not exceeding 50 m(b) PCC 1:4:8, type D-2 using 40mm graded stone aggregate in foundation 900mmx600mm cross section and planting depth 1.5 m for concrete encasing the pole upto GL(c) PCC 1:3:6, type C-1 using 20mm graded stone aggregate for plinth block/collar above GL 500mm high and 450mm dia(d) Painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminum paint over a coat of red oxide primer including preparation of surface and painting of 30 cm wide bands 3 Nos with synthetic enamel paintof appropriate colour in alternate layer upto the height of 1.5mm above plinth block(e) Writing letter or figures (Block Roman, Italic as Indian) with thick synthetic enamel paint of apprised shade not exceeding 5 cm height including numbering of pole(f) Painting of coping with two coats of cement based paint .Note : Manufacture's test certificate shall be produced alongwith purchase vouchers . |
| 112 | Supply, installation, testing and commissioning of Step down transformer of capacity 160 KVA, outdoor type, copper wound, latest BEE type, PCC plinth mounted complete with standard fitting and accessories, HT 11KV 3 Phase, LT 433 volt, 3 phase 4 wire with off load tap changer on primary side to carry secondary voltage ± 7½ % with tappings at every 2½ % all as per IS 1180-2014, EEL-III, oil cooling with fins vector group : DYN 11, including initial oil fitting complete all as specified including the following accessories :- (a) Three numbers porcelain bushing HT, 11KV with brass bushing rods, nuts, bolts and washers etc insidecable end box.(b) One cable box LT side consisting of 4 Nos porcelain with brass bushing rods complete with nuts andwashers suitable for runs of 3.5 core LT under ground cable.(c) Oil conservator with filler type drain valve and oil level gauge.(d) Dheydrating breather with fast fill of dehydrating agent.(e) Explosion vents(f) Thermometer pocket on tank cover.(g) One number 100mm dia, dial type thermometer vapour pressure type having range 0 to 120 degreecentigrade.(h) Rating plate and terminal marking plate.(j) Earthing arrangement.(k) Oil drain filter valve.(l) Oil drain valve. (m) Lifting hook.(n) Oil conservator with filling hole and cap.(o) Air relief valve plug.(p) Four plate solid cast steel detachable rollers.(q) Earth bushing for neutral outside the cable box for providing independent earthing for neutral.(r) Suitable size of channel on foundation for fixing the transformer with joint and stopper.(s) PCC plateform complete all as shown on drawing No CEAF/TD/EM/03 SHEET 1/1 Dated 31.10.1994 revision date 09.06.2003 including XPM welded mesh fencing and doors including 75 x 40 mm channel. 0.0 |
| 113 | Supply and fix Lightning arresters expulsion type 11000 voltscomplete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed |
| 114 | Supply and laying sand cushioning for cable protection in trenches 8cm before laying cable and 15 cm deep over the cable all as specified and directed. |
| 115 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sq. m 3 Core complete all as directed by Engr-in-Charge |
| 116 | Supply, stringing and fixing of aluminium conductor steel reinforced (ACSR) of any type including binding with and including suitable size of binding wire complete all as specified and directed. Make - Jaipuria Brothers, Atlas, Bhel. |
| 117 | Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heacy duty) 1100 volts grade with standard aluminium conductor of size 240 Sqmm, 3.5 Core complete all as specified and directed. |
| 118 | Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heacy duty) 1100 volts grade with standard aluminium conductor of size 185 Sqmm, 3.5 Core complete all as specified and directed. |
| 119 | Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heacy duty) 1100 volts grade with standard aluminium conductor of size 70 Sqmm, 3.5 Core complete all as specified and directed. |
| 120 | Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heacy duty) 1100 volts grade with standard aluminium conductor of size 35 Sqmm, 4 Core complete all as specified and directed. |
| 121 | Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heacy duty) 1100 volts grade with standard aluminium conductor of size 16 Sqmm, 4 Core complete all as specified and directed. |
| 122 | Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heacy duty) 1100 volts grade with standard aluminium conductor of size 10 Sqmm, 4 Core complete all as specified and directed. |
| 123 | Supply and fix steel tubular swaged poles type 410 SP - 31 (9 mtr long ) complete with CI base plate and finial including foundation and copping complete all as specified and directed. |
| 124 | Supply and fix cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium comductor cable of size 95 sqmm 3 core complete all as specified and directed. |
| 125 | Supply and fix LED street light 35/36 Watt IP 65 complete all as specified and directed |
| 126 | Supply and installtion of galvanised steel high mast lighting system of 15.0 meters in two section 3 mm section thickness top dia 150 mm bottom dia 360 mm with 2/3 wire rope sytem with control panel/feeder pillar and foundation and its accessories suitable for loading 06 nos 210 watt flood light symmetrically lightning finial GI single spike, foundation bolts, anchor plates, templates, trailing cables & integral power tool for raising and lowering operation suitable for wind velocity as per IS 873 part 3 and geographical condition of Darbhanga with construction material S 355 as per BS-EN10025 20 side polygon cross section of mast double drum winch with 3 phase integral motor stainless steel wire rope AISI 304 7/19 construction with minimum breaking capacity 1450kgx2 and powder coated feeder pillar min 2.0 mm CRCA with astro type timer for automatically on/off and factory considering safe soil bearing capcity and trailing cable PVC insulated PVC shaethed 1100 volt multi stranded 6 core 2.5 sqmm complete all as specified and directedby EICalongwith all connected electrical assessories complete all as specified and as directed. |
| 127 | Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all specified and directed. |
| 128 | S&F light grade galvanized iron pipe 80 mm bore confirming to IS : 1239 and ISI marked with all fittings fixed on walls/poles/crossing of road etc for protection of cable complete all as specified and directed. |
| 129 | S&F light grade galvanized iron pipe 100 mm bore confirming to IS : 1239 and ISI marked with all fittings fixed on walls/poles/crossing of road etc for protection of cable complete all as specified and directed. |
| 130 | M & L for PCC 1:3:6 (nominal mix) type C-2 using 40mm graded crushed stone aggregates as in foundation filling land mass concerte for poles and stay/installation paths complete all as specified and directed. |
| 131 | M & L for PCC 1:2:4 (nominal mix) type B-1 using 20mm graded crushed stone aggregates as in copies of poles and the like complete including weathering, slightly rounded or chamfered angles and throating all as specified and directed. |
| 132 | Supply and Fix horn gap type fuse unit upto 25 Amps capacity, mounted on insulators and steel frame operated mechanism worked from ground level single pole 11 kV dropout lift off (DOLO) complete all as specifed and directed. 18` Supplying and laying bricks, common burnt clay building sub class \\"B\\" bricks laid across the cable in trenches for cable protection, complete all as specified and directed. 1000 Nos 10.17 5551.88 56462.62 |
| 133 | Supply, test, install & commissioning of HT 11 KV outdoor type Gang operated air break switch triple pole mechanically operated suitable for horizontal or vertical mounting(suitable for existing one) on insulator and steel frame with operating mechanism worked from ground level for current rating up to 400 Amps and connecting up with jumpers, complete all as directed by Engr-in-Charge. Make - OBLUM/ BHEL / JAIPURIA / CROMPTON GREAVES . Total amount of Schedule ‘A’ Part-V carried over to BOQ Rs 2613292.2 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- VISEWAGE DISPOSAL Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 134 | M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filing and mass concrete. |
| 135 | M&L for reinforced concrete pipes, class NP2, laid and jointed complete with collars bore of pipe 200 mm, complete all as specified and directed. |
| 136 | M&L for Concrete bed for 20 mm bore of pipe in PCC 1:3:6 type C-2 to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed. |
| 137 | M &L Brickwork with fsub class \\"B\\" bricks, straright or curved on plan exc 6m mean radius built in Cement mortar 1:4 complete all as specified and directed. |
| 138 | M & L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in CM 1:4 and finished even and smooth without using extra cement with water proofing comound as per manufacturere's instructions, complete all specified and directed.NOTE WATER PROOFING COMPOUND SHALL BE MEASURED AND PAID SEPERATELY. |
| 139 | M & L for cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate in surface channel, and drain, complete all as specified. |
| 140 | M&L for forming fair finished drain or channel 90cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and as directed. |
| 141 | M & L for providing precast cement concrete, type B-1 1:2:4 (using 20 mm graded stone aggregates) as in landings, cover slabs (for drain/manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4 complete all as specified. (Note : Reinforcement shall be measured and paid seperately) |
| 142 | S & F TMT bar 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with and includingmild steel wire(annealed) not less than 0.9 mm dia. |
| 143 | Supply only liquid water proofing compound. |
| 144 | Material and labour for PCC 1:3:6 type C1,using 20mm graded stone aggregate, as in coping including necessary form work/moulds and finishing the exposed surfaces all as specified and directed. |
| 145 | Cutting into existing manholes for connceting new drains of internal diameter 150mm bore, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4, type B-I, smooth finished, and reforming benching as required etc., complete all as specified and as directed. Total amount of Schedule ‘A’ Part-VI carried over to BOQ Rs 368154.41 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- VIIAREA DRAINAGE Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 146 | M&L for PCC 1:3:6 type -C2 using 40 mm graded stone aggregate as in foundation filling / mass concrete, complete all as specified and directed by Engineer - in- Charge. |
| 147 | M&L for brick work with sub class \\"B\\" bricks(Old size) straight or curved on plan exceeding 6 M mean radius, using old size bricks built in CM 1:4 complete all as specified and directed by Engineer - in- Charge. |
| 148 | M&L PCC type C1,1:3:4 (20 mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer - in- Charge. |
| 149 | M & L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in CM 1:4 and finished even and smooth without using extra cement, complete all as specified and directed by Engineer - in- Charge. |
| 150 | M & L for cement concrete 1:2:4 type B-0, using 12.50 mm graded stone aggregate in surface channel, and drain, complete all as specified and directed by Engineer - in- Charge. |
| 151 | M&L for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed by Engineer - in- Charge. |
| 152 | Add or deduct from item No 6 for each 25mm girth or part thereof over or under 30cm -ditto- and directed by Engineer - in- Charge. |
| 153 | M&L for precast reinforced cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in drain cover slab complete all as specified and directed. |
| 154 | Material and labour for TMT mild steel bars 10mm dia and over, cut to length, bent to shape required, including cracking, bending spirally with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed. |
| 155 | S&F 300mm bore of Reinforced concrete pipes, class NP3, laidand jointed complete with collars, including 300mm thick PCC 1:3:6 Concrete bed to drain pipes, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. Total amount of Schedule ‘A’ Part-VII carried over to BOQ Rs 903739.41 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- VIIIROAD/ PATH/ CULVERT/ HARD STANDING Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 156 | Rolling and consolidating formation surface in cuting and compacted with power roller exc 8 tonne and n. exc 12 tonne including watering necessary cosolidating to required level ,gradient or camber.Note :- Each course or layer rolled shall be measured. |
| 157 | M&L for Laying and compacting 300 mm thick (compacted thickness) granular sub base course (GSB) grading-II as specified table 400-1 of MORTH specifiactions for road and bridge work, 2013 in two layer of 150 mm thick (compacted thickness) over compacted subgrade with natural sand,crushed gravel,crushed stone,crushed slag,or combination therof as per the grading required.the materials are mechanically mixed,spread and levelling on the subgrade by using motar grader of adequate capacity and rolling with viberatory roller of capacity 80-100 KN static weight for achieving required compaction density of at least 98% of the maximum dry density, consolidating to required gradient and camber for each layer, complete all as specified and directed with finished surface tolerances as per table 900-1 of MORTH specification for road and bridge work, 2013. |
| 158 | M & L for 250mm thick Cement conrete type D-2 1:4:8 using 40mm thick graded stone aggregate laying in floors/ roads, complete all as specified and directed. |
| 159 | M&L for PCC M- 25 design mix using 20 mm graded stone aggregate as in Pavement surface for road etc complete as specified and directed by Engr-in-Charge |
| 160 | M & L for finishing surface of concrete roads, pavements, by wire brush brooming, complete all as specified and directed. |
| 161 | M&L for forming 20 mm thick expansion joints filled with perforated bituminous filler and top 30mm primed amd sealed with sealing compound grade `A` for 250 mm thick concrete slab all as specified and directed. |
| 162 | M&L for forming Contraction (Dummy) joints 85mm deep x 10mm wide, filled with sealing compound Grade 'A,' complete all as specified and directed. |
| 163 | M & L for forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade 'A', complete all as specified and directed. |
| 164 | M&L for Hardcore of broken stone or boulder guage exc 63mm but n exc. 100mm, deposited, spread and levelled in layers n exc. 15mm thick, watered and rolled/rammed to a true surface, complete all as specified and directed |
| 165 | M & L for Screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes, complete all as specified and directed. |
| 166 | M&L for preparation of new plastered or cement concrete surface of kerb stones and the like over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer, complete all as specified and directed. |
| 167 | M & L for providing 150 mm thick cement concrete type D2, 1:4:8 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed. |
| 168 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. NOTE :- Shape / Design / Colour shall be as approved by GE. |
| 169 | M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed. |
| 170 | M&L for Painting lines, dashes, arrows, letters, etc. on roads, pavements and the like exc 10cm wide with road marking paint, white or golden yellow, complete all as specifiedand directed. |
| 171 | M&L cement concrete 1:4:8 type D2 ( using 40mm graded stone aggregates ) as in foundation filling and mass concretecomplete all as specified and directed. |
| 172 | Material & labour for brick work with sub class ‘B’ bricks straight or curved on plan exc. 6 mtr mean radius built in CM (1:6) complete all as specified and directed by Engineer-in-charge. |
| 173 | M&L PCC type C1,1:3:6 (20 mm graded stone aggregate) n lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 174 | M& L for use and waste of form work to soffits of suspended slab such as roof slab floor slab, landings and similar works etc for fair finished surface not exceeding 200 mm thick complete all as specified and directed. |
| 175 | M& L for use and waste of form work to edges of concrete flats n.exc 20 cm wide etc for fair finished surface exc 100 mm but not exceeding 200 mm thick complete all as specified and directed. but |
| 176 | S&F mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including MS wire (annealed), not less than 0.9 mm dia as in reinforcement complete all as specified and directed |
| 177 | M&L RCC M- 25 design mix using 20 mm graded stone aggregate as in slab supported on walls,beams and columns in floors roof for culvert etc complete as specified and directed by Engr-in-Charge |
| 178 | M & L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in CM 1:4 and finished even and smooth without using extra cement with water proofing comound, complete all as specified. |
| 179 | M&L for applying three coats of white wash on newly plastered surface of walls including preparation of surface complete all as specified and as directed. Total amount of Schedule ‘A’ Part-VIII carried over to BOQ Rs 8967368.62 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- IXEARTH WORK, SITE CLEARANCE & DEVELOPMENT Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 180 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, all kind of soil as directed by Engineer-in-charge. |
| 181 | Excavation over areas not exc 1.50 mtr depth and getting out in soft / loose soil, complete all as specified and directed |
| 182 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified and directed. |
| 183 | Removal of excavated material not exceeding 50 mtr and deposintg where directed at a level n.exceeding 1.5 m above the starting point in soil complete all as specified and directed. |
| 184 | Removal of excavated material exceeding 1.5 Km and upto a total distance of 5.0 Km deposintg where directed at a level n.exceeding 1.5 m above the starting point in soil complete all as specified and directed. |
| 185 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil |
| 186 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. |
| 187 | Excavation in post holes or (similar holes) each n exc 0.50 Cum in soft/loose soil, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25cm watering and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed. Total amount of Schedule ‘A’ Part-X carried over to BOQ Rs 670054.49 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- XDEMOLITION AND DISMANTLING Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 188 | Demolition of birck work or stone/boulder masonary built in cement mortar |
| 189 | Demolition of cement concrete ( unreinforced) in ground floor and paving n exc 15 cm thickness (below or above GL) complete. Total amount of Schedule ‘A’ Part-XI carried over to BOQ Rs 18025.03 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- XIFIRE FIGHTING Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 190 | Supply, laying, cutting to required lenth jointing and testing of MS ERW plain end pipe of 100 mm bore heavy duty ( Class \\"C\\") & confirming to IS-1239 or latest revison of IS with necessary required fittings welding,nut,bolts & washer, dully painted with two coats of synthetic enamel paint over a coat of Zink chomate primer laid in trenches/fixed to wall/floor for fire fighting purpose as riser complete all as specified and directed. Make:- Jindal/Tata/Sail Note :- Excavation will be measured separately. |
| 191 | Supply and fix fire hydrant/landing valve type 'A' ( single head outlet) of 63 mm dia coupling instantanious outlet ISI marked including all required meterial riser as cutting welding pipe and fittings etc to IS 5290 complete all, as specified and directed. |
| 192 | Supply and fixing of hose box (cabinet) of size 800x600x250mm indoor type made out of 2mm thick MS Sheet with ceter opening glazed doors (4mm thick clear glass) and locking arrangement including painted with two coats of synthetic enamlled paint over a coat of red oxide primer and the word \\" FIRE\\" to painted on box, suitable for housing 2 Nos hose pipe of length 15 mtrs each with branch pipe,nozzle,coupling etc all as specified and directed. |
| 193 | Supply, and fixing of 63 mm dia gun metal branch pipe with 20 mm nozzle confirming to IS 903 complete, all as specified and directed. |
| 194 | Supply & fix 63 mm dia 15 mtrs long RRL hose pipe type-A confirming to IS complete with male and female coupling confirming to IS 903 complete, all as specified and directed. |
| 195 | Supply and fix Valve , Sluice valve both end flanged of class 1.6 PN, 100 MM dia ISI marked complete with jointing material all as specified and directed. |
| 196 | Supply and fix Valve , butterfly confirming to IS 13095,100 mm (4\\") diacomplete, all as specified and directed. |
| 197 | Supply and fix rubber hose reel of 20 mm dia and 30 mtr length confirming to IS 5132 with 20mm glove valve complete, all as specified and directed. |
| 198 | Supply installation testing and commissioning of 32 Bit Microprocessor based Intelligent Addressable 2 Loop Main Fire Alarm Panel expandable to 10 Loops having loop capacity of minimum 250 devices per loop with 4000 eventplus 1000 alarm log history events, QWERTY keypad for programming with inbuilt panel display.The panel shall be networkable over copper wire for 900m with a network speed of minimum 312 kbps. The Intelligent panel shall be able to give pin point location of all fire/fault conditions. The panel shall be complete with Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on same peer-to-peer Network capable of supervising all the speaker circuits with adequate zone control and accessories. The Voice evacuation amplifier shall be of 70W and shall have automatic battery charger available with it. The fire alarm panel and all accessories shall be UL Listed and FM approved. The Fire alarm control panel shall be provided with 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during an emergency conditions as required. Approval standards UL/ VdS / FMMAKE: NOTIFIER/HONEYWELL/EDWARDS/SIEMENS |
| 199 | Supply, install, commissioning and testing of Addressable type manual call point re sattable type with relay module incl all acessories like junction box, glands etc |
| 200 | Supply and installation, testing and commissioning of Intelligent addressable loop powered sounder, in built turbo Isolator, able to provide an o/p of 88dBA at 1m, peak light o/p of at least 3.2cd and shall have 11 programmable tones, 3 volume settings selectable from the panel and fully synchronized with other sounders and shall have the ability to switch between one tone for alert and one tone for evacuation. Shall have protection category of IP42 and duly approved by EN54/LPCB/VDS/FM |
| 201 | S & F Booster pump confirning to IS 12469 - 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearing suitable for 440 Volt 3 Phase 50 Hz 30 Mtr head, 900 LPM discharge |
| 202 | Supply and fixing of PA system micro phone set including all necessary connections complete all as specified and as directed by the engineer in charge |
| 203 | Supply, laying & testing XLPE Cable with Aluminum conductor 4 Core, 4 Sq mm 1100 Volts grade.(For Repeter Panel) |
| 204 | Supply and laying cable UG XLPE insulated, screened, PVC bedded with galvanised steel strip or wire armoured, 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core |
| 205 | Supply and fix pressure gauge 100 mm dia with ball valve of pressure 0 to 14 Kgs rating complete, all as specified and directed. |
| 206 | Supply and fix non return butterfly Valve 100 mm (4”) dia |
| 207 | S & F pressure switch universal type Total amount of Schedule ‘A’ Part-XII carried over to BOQ Rs 681303.0 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- XIILIGHTENING PROTECTION Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 208 | Supply and fix Aluminium strip 25 x 3.15 mm with PVC saddles and fixing screws etc. for roof conductors and down conductors above ground all as required at site as directed. |
| 209 | M&L for air termination vertical type single pointed rod made of 12 mm dia 300 mm long aluminium rod including necessary fixing arrangement with bolt, nuts and washers etc complete all as specified and directed. |
| 210 | M&L for test point terminal block made of gun metal or phosphrus bronze of size 75mm X75mm X25mm drilled and screwed including 03 Nos. 8mm dia 25mm long hexagonal head screws complete all as specifed and directed. |
| 211 | Supply and fixing GI strip of size 32x6mm burried in ground/fixed on wall complete with fixing screws, nuts, bolts and washers etc.(use for ring conductor and earth conductor) |
| 212 | S&F GI pipe light grade of size 25 mm dia with all fittings laid in trenches/ floors (or) fixed to walls for protection of Copper/GI/Aluminium strips complete all as specified and directed. |
| 213 | M & L for PCC 1:2:4 type B1 (using 20m graded aggregated) of size 300x300x400mm for mounting air conditioning using 4 Nos foundation bolts, all as specified and directed. Total amount of Schedule ‘A’ Part-XII carried over to BOQ Rs 149024.74 Signature of Contractor AAD (Contracts) For Accepting Officer SCHEDULE ‘A’ PART- XIIILIFT AND DG SET Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 214 | Supply, install, testing & commissioning traction passenger elevator in machine room directly located on lift well (shaft) Electrically operated with microprocessor based full simpelx colletive control attendant 8 Passenger, 544 Kgs lift suitable to serve G+5 upper floors with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories, simplex automatic and manual dual Closed loop controlled operation with/without attendant, telescopic opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set & human interface device(HID). all as specified below and all as per IS-14665 & IS-15785 :-Note: (i) Contractor to submit detailed construction drawings of lifts being provided with complete technical specifications as per IS: 14665 before dispatch of material from OEM for approval of GE.(ii) The scope of work also covered the civil work comprising cutting of holes and making good. car and counter weight guide rails and bracket, terminal buffers supports and sill angle, plates and any other items required for successfull completion of lift with respect to safety required by the OEM, will be carried out by contactor without any extra cost. (iii) The contractor shall be responsible for 2 years defect laibility period from certified date of completion of GE. During the said defect liability period the lift,shall be kept functional/serviceable all the time & all consumable items shall be provided by contractor for operation & maintenance of lift. All periodical maintenance regular check up/inspection shall be carried out by OEM during 02 years defect liability period.In addition to regular checkups and periodical services special visit/inspection will also be carried out to rectify defects by representative of OEM if any emergency / trouble developed.An agreement will be made between contractor & OEM ,and this shall be submitted to GE on the date of handing over of lift for the comprenssive maintenance of defect liability period. The cost of above shall be deemed to be included in the quoted rates. (iv) The provision of suitable steel structure/ palteform for installation of lift equipment is part of lift item and nothing extra shall be paid. (v) If any clearance required from state goverment i.e. lift inspector/ electrical safety department/ fire safety departments is the contactor's responsibility & any expenditure on this account shall deemed to be included in the quoted rates. BASIC DATA / TECHNICAL SPECIFICATION(a) Type of Lifts : Passenger machine room type(b) Load & capacity : 544 Kgs/ 08 Persons(c) Speed : 1.00/ mtr/sec (d) Power Supply : 415 volts, 3 phase AC, 50 Hz (e) Machine : 3 Phase Single speed Electric Motor lift duty reversible gearless complete with sheaves and motor controller to be installed in machine room. (f) Stpos and openings : 6 Stops and 6 openings, Single entrance Car.(g) Travel hight : 6 Floor of residential building.(h) Grouping/Operetion : Simplex, Full collective.(j) MAP Floor position : Top most floor.(k) Car size : 1100 mm wide x 1300 mm deep x 2200 mm height or as per IS and suitable to install in lift shaft size mentioned in drgs.(l) Door size : 800 mm wide x 2000 mm height or as per IS and manufacturer specification.(m) Door type : Two- panel Centre opening , telescopic stainless steel with Air vent, automatic operated door. (n) lift well size 1900x1900mm, pit depth-1600mm or over head 4200mm.(o) Indicators : Car position indicator car & landing direction and position, indicator with stainless steel fixtures at all floor with dot red led scrolling display. (p) Traction media : Round stranded steel wire row confirming to IS-14665-2000 or as per manufecturer specification with gaurds. (q) Call register type micro push button for opening and closing of doors. FINISHES(a) Car design : Stainless steel 340 hair line finish/mirror polished(b) Car panel finish : Mirror polished stst./hair line stainless steel(c) Hand rail : Round bend hand rail stainless steel at rear wall.(d) Ceiling and lighting : Metallic stain less steel with led light fixtures.(e) Flooring : Ggranite stone.(f) Car door finish : Stainless steel hairline finish with fire raitng 60 min.(g) Landing door mark : Floor Number - G to 5, Floor mark G,1,2,3,4,5, Landing door material- Stainless steel grade 304 hairline finish with fire rating 1 hrs.(h) Car opening panel : 304 graded hair & mirror polish Brushed StSt, Tempered glass segmented LED display round flush mounted.(j) Landing signalization : TG, Tempered glass segmented dot red LED scrolling display display flush mounted TG, tempered glass round flush mounted. STANDARD SAFETY FEATURES/DEVICES(a) Car emergency light, Fireman drive, Curtain of light, Accurate relevelling, Automatic closed door.(b) Emergency rescue device with audio announcer, nudging attendent service, ring lighting LED.(c) Digital direction and position indicator in car and at all landings.(d) Emergency alarm at the main landing with alarm bell button in car.(e) 2 Phase/2 way fire man drive, fire man switch at the main landing.( In case fire man drive is activated the lift will come to the main landing and open the door)(f) Advanced door operation ( To ensure smooth opening and closing of the doors at adjustable door speed)(g) Additional pressure sensing device.(h) Load weighing device ( Audio visual over load indicator in the car for better safety)(j) Full height infra-red curtain ( Highly sensitive safty device for safe entrance and exit of the passangers in to the car). (k) Pit ladder ( To ensure safety of the maintenance personnel). (l) Emergency light, Intercom and alarm with maintenance free rechargable battery operation ( To ensure passenger comfort and safety in case of emergency)(m) Over speed governor ( Electro mechenical device that prevents free fall in case the elevator is travelling at speed more than 10 % of the rated speed in down ward direction)(n) Automatic rescue device ( To rescue the passengers in case of emergency, the device will bring the car to the nearest floor automatically and will open the doors).(o) Special car door lock, Automatic daily brake testing, Latest technology motor-PMS, Touch panel with LED display.(p) Mechanical rescue device with no dependence with battery.(q) Cross flow fan, 2 way built in communication system, anti nuisance car call protection. (r) Door time protection with extra door time for lobby and parking, auto fan cut off. (s) Mirror on rear side wall and voice synthesizer.(t) Controller shall be include protection against over current,over voltage, single phasing, phase reversal, earth leakage and interlocking with door opening, closing and moment of lift and any other operation required for the safety of passenger as per fire safety regulation pertainging to lift. (u) Emergancy stop button with alarm. (v) Two position key operated switch with attended and without attended switch mode. (w) Any other accessories / safety device required as per IS for safety of passengers. |
| 215 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq.mm 3 1/2 core |
| 216 | Supply and fix DB Triple pole and neutral 4 way 415 Volts. (For Lift). |
| 217 | Supply and fix, MCB, SP, 63 Amp 415 Volt, 16 KA TPN complete all as specified and as directed by Engr in Charge. Total amount of Schedule ‘A’ Part-XV carried over to BOQ Rs 4516557.48 Signature of Contractor AAD (Contracts) For Accepting Officer CA NO. CE(AF)/PRZ/DBG/10 of 2026-27 Sl Page No 54 SCHEDULE ‘A’ PART- XIVBARRICADING WORK Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 218 | M&L for PCC 1:5:10 type E-2 using 40mm graded stone aggregate as in Foundation filling and mass concrete. Complete as specified and directed. |
| 219 | S&F Hand rails, half round or other stack section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nut bolts, nosing to steps including embedding in concrete and screwing etc wing ties for roof including securing bolts, points and struts in fencing including cutting tops to shape ass directed. drilling holes notching ro wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, and similar work conforming to Fe 410-0or FE 310-0 complete. |
| 220 | S&F for MS nut and bolts 12mm dia and n.exc 75mm long and complete all as specified and directed. |
| 221 | M&L preparation of new steel surface of any description exceeding 10cm with or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer all as specified and directed |
| 222 | S&F prepainted galvalume aluminium zinc coasting Gl based corrugated steel sheet 0.5mm thick of any colour having tensile strength 550 as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed. |
| 223 | Dismantling corrugated steel sheeting, any gauge, thickness at any portion as in wall/ barricading complete all as specified and directed. |
| 224 | Dismantling post or struts any section and size including taking out embedded portion in concrete and making good disturbed ground in natural ground complete all as specified and directed. |
| 225 | Dismantling wrought iron or mild steel work description not otherwise provided for fencing post complete all as specified and directed. Total amount of Schedule ‘A’ Part-XV carried over to BOQ Rs 1677389.96 CA NO. CE(AF)/PRZ/DBG/10 of 2026-27 Sl Page No 55 SCHEDULE ‘A’ PART- XVTYRE WASHING POINT Srl No Description of items of works Unit Rate in Rs No of units Amount in Rs |
| 226 | M&L cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundations filling and mass concrete etc, complete all as specified and directed. |
| 227 | M&L for old sized Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed |
| 228 | M&L for Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimeter in field using 400 kg of cement per cubic meter, thickness of concrete 25 cm or less. Complete all as specified and directed. |
| 229 | M&L for rendering 15 mm thick in cement mortar (1:4) on brick work or concrete surfaces finished even and smooth without using extra cement mixed with WPC as per manufacturer instruction complete all as specified and directed. (Note - W&C shall be mearured and paid seperately). Total amount of Schedule ‘A’ Part-XV carried over to BOQ Rs 106229.85 Signature of Contractor AAD (Contracts)For Accepting Officer SCHEDULE ‘A’ PART- XVISCH OF CREDIT (CREDIT FOR MATERIALS OBTAINED FROM DEMOLITION / DISMANTLING) NOTE :-1. The materials listed below retrieved from demolition/dismantling as specified in Schedule of credit shall become the property of the contractor and the credit amount as indicated below shall be recovered from the RAR as the work proceeds. Demolition of the work shall be carried out after it is handed over for demolition all as directed by the Engineer-in-Charge. Any other retrieved item not listed below shall become Govt property.2. The unit rate of salvage materials which will become the property of contractor as assessed by the department is indicated in the schedule of credit and it is final and binding. The contractor is deemed to have visited the site and made his own assessment regarding condition of the materials. No claim of the contractor Whatsoever against the department regarding actual cost of salvage material is admissible.3. The contractor shall be responsible to remove the materials obtained from demolition from the site as directed and the site shall be left clean and tidy and same shall be deemed to be included in the rates quoted for demolition.4. The contractor shall be allowed to remove the salvage materials from the site only after written approval of the GE after necessary recovery has been made in the RAR. However in case of any dispute regarding demolished item, decision of CWE shall be final and binding upon both the parties.5. The quantities mentioned under column 4 are approximate and are given as rough guide only. The quantities obtained from items of Schedule 'A' for demolition shall be considered for credit. The tenderer shall not have any claim whatsoever for any variation of quantities given in Schedule of credit. Srl No Description of items of works Unit No of units Rate in Rs Amount in Rs |
| 230 | Old unserviceable brick / stone builder masonry built in Cement mortar |
| 231 | Old unserviceable scrap iron |
| 232 | Old Unserviceable steel corrugated sheet Total amount of Schedule ‘A’ Part-XVIII carried over to BOQ Rs 442497.6 Signature of Contractor AAD (Contracts) For Accepting Officer Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 32 daysDec 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 39 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender