Tender For Repairs/Maint/Servicing Of Solar Panels, Inverters, Solar Street Lights And Ups Systems Under Ge Chennai
Tender Value
35 Lakhs
Estimated cost
Bid Submission
10 Dec 2026
19 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs/Maint/Servicing Of Solar Panels, Inverters, Solar Street Lights And Ups Systems Under Ge Chennai
BOQ
| Sl. No. | Item Description |
| 1 | Taking down old U/S Solar Modules, Supply, installation, testing, and commissioning of a solar photovoltaic (PV) system of cumulative capacity in KWp (AC output), as per site-specific requirements. The system shall comprise high-efficiency Mono PERC PV modules (ranging from 320W to 600W) associated cabling, safety systems and other balance-of-system (BoS) components.The installation shall be carried out in accordance with best industry practices and under the supervision of the Engineer-in-Charge, ensuring full compliance with relevant national and international standards, complete all as specified and directed by Engr-in-Charge. |
| 2 | Taking down old U/S, MC4 connectors, Supply and Fix of Male & Female MC4 connectors (M-10, F-10) & joints suitable, complete all as specified and directed by Engr-in-Charge. |
| 3 | Taking down old U/S Flexible Cable and Supply,fixing,Testing and commissioning Copper PVC Flexible Cable 1.1KV, 4 core, 25 sqmm heavy duty in PVC Conduit of suitable size and fixing of conduit with clamps on wall/floor, complete with all as specified and directed by Engineer-in-Charge. |
| 4 | Taking Down old U/S HDPE Pipe and M&L Protection Pipe for 6 sqmm copper cable High density polyethylene pipes (HDPE) of min 16 sqmm cross section area and pressure rating 6 kgf/cm2 for protection of copper cable laid in fixed on wall with GI support, Clamp included, complete all as specified and directed by Engr-in-Charge. |
| 5 | Supply and laying in replacement of annealed single copper DC String cable of 1C x 6 Sqmm Solar grade, UV resistant 1.5 kV rated DC Cables with electron beam XLPO insulation including necessary accessories like lugs, nails, cable ties, termination etc, including taking down of old u/s cables, complete all as specified and directed by Engr-in-charge. |
| 6 | Taking down old U/S SPD and Supply, installation, testing, and commissioning of AC Surge Protection Devices (SPD), Class 2, with a minimum input surge withstand capacity of 4 kV, conforming to IEC 60364-5-53 and IEC 61643 standards. These devices shall be used to protect sensitive solar Inverter from transient overvoltages and surge currents originating from lightning strikes, switching operations, or other electrical disturbances in the system complete all as specified in Particular Specification and directed by Engineer-in-Charge. |
| 7 | Repair/Maint servicing of U/S Solar Grid Tied String Inverter of 50 KW included:-(a) M1 (Controller) board 9 string(b) P board(c) M1 (Controller) board 9 string(d) W board (9 string)(e) W board 9 string(f) DC Power cord Red/Black(g) Fan(h) M3 (L) Board(i) C1 (S) Board(j) fuse board 12s(k) AC Plug(l) AC SocketComplete all as specified in Particular Specification suitable for above solar module and as directed by Engineer-in-Charge Note :- Price must include to and fro of item from site to desired location and to be performed by authorised solar plant service engineer. |
| 8 | Supply, fixing and testing Control Board of RPI M50A model after removing old unservicable one, complete all as specified and directed. |
| 9 | Supply, fixing and testing Relay Board of RPI M50A model after removing old unservicable one, complete all as specified and directed. |
| 10 | Payment towards AMC of SCADA for complete monitoring of all the performances of the inverter (power, array voltages, array currents and AC parameters), energy yield, weather conditions viz temperature, irradiance level etc complete all as specified and directed. |
| 11 | Payments towards internet charges for operation of SCADA, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 12 | Payments towards internet charges for operation of SCADA, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysDec 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer