Tender for Development Of Baba Dhableswar Temple, Kataka.

BOQ

Name of Work:- Development of Baba Dhableswar Temple, Kataka.
Sl. No. Item Description
1CIVIL WORKEarth work excavation in foundation trenches in Hard Rock including dressing and leveling the bed up to required depth and depositing the excavated materials at places away from work site within 50mtr initial lead and 1.5mtr initial lifts T&P shoring shuttering dewatering if required etc. complete as per direction of the Engineer-in-charge.Up to 1.5Mtr DepthSevayat Bhawan (1NOS-6SH)
2Sevayat Bhawan (1NOS-10SH)
3Sevayat Bhawan (3NOS-13SH)
4Sevayat Bhawan (1NOS-17SH)
5RETAINING WALL & TOE WALL
6FILLING & STONE PITCHING
7PARIKRAMA
8RAIN SHED. (4 Nos)
9PILLERED HALL. (4 Nos)
10RUDRAVISEK HALL WITH KITCHEN & STORE
11PARKING, PATHWAY AND ROUND ABOUT
12DRAINAGE SYSTEM(600X600 & 300X300) size
13Earth work excavation in foundation trenches in all kind of soil (Hard Soil, Ordinary Soil & Stoney Earth) including dressing and leveling the bed up to required depth and depositing the excavated materials at places away from work site within 50mtr initial lead and 1.5mtr initial lifts T&P shoring shuttering dewatering if required etc. complete as per direction of the Engineer-in-charge.Up to 1.5Mtr DepthSevayat Bhawan (1NOS-6SH)
14Sevayat Bhawan (1NOS-10SH)
15Sevayat Bhawan (3NOS-13SH)
16Sevayat Bhawan (1NOS-17SH)
17RETAINING WALL & TOE WALL
18FILLING & STONE PITCHING
19PARIKRAMA
20RAIN SHED. (4 Nos)
21PILLERED HALL. (4 Nos)
22RUDRAVISEK HALL WITH KITCHEN & STORE
23PARKING, PATHWAY AND ROUND ABOUT
24DRAINAGE SYSTEM(600X600 & 300X300) size
25Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge.Sevayat Bhawan (1NOS-6SH)
26Sevayat Bhawan (1NOS-10SH)
27Sevayat Bhawan (3NOS-13SH)
28Sevayat Bhawan (1NOS-17SH)
29RETAINING WALL & TOE WALL
30FILLING & STONE PITCHING
31PARIKRAMA
32RAIN SHED. (4 Nos)
33PILLERED HALL. (4 Nos)
34RUDRAVISEK HALL WITH KITCHEN & STORE
35PARKING, PATHWAY AND ROUND ABOUT
36DRAINAGE SYSTEM(600X600 & 300X300) size
37Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge.Sevayat Bhawan (1NOS-6SH)
38Sevayat Bhawan (1NOS-10SH)
39Sevayat Bhawan (3NOS-13SH)
40Sevayat Bhawan (1NOS-17SH)
41RETAINING WALL & TOE WALL
42PARIKRAMA
43RUDRAVISEK HALL WITH KITCHEN & STORE
44PARKING, PATHWAY AND ROUND ABOUT
45DRAINAGE SYSTEM(600X600 & 300X300) size
46Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge.Sevayat Bhawan (1NOS-6SH)
47Sevayat Bhawan (1NOS-10SH)
48Sevayat Bhawan (3NOS-13SH)
49Sevayat Bhawan (1NOS-17SH)
50RUDRAVISEK HALL WITH KITCHEN & STORE
51Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge.Ground FloorSevayat Bhawan (1NOS-6SH)
52Sevayat Bhawan (1NOS-10SH)
53Sevayat Bhawan (1NOS-13SH)
54Sevayat Bhawan (1NOS-17SH)
55RETAINING WALL & TOE WALL
56PARIKRAMA
57RAIN SHED. (4 Nos)
58PILLERED HALL. (4 Nos)
59RUDRAVISEK HALL WITH KITCHEN & STORE
60PARKING, PATHWAY AND ROUND ABOUT
61DRAINAGE SYSTEM(600X600 & 300X300) size
62Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading and compacting to meet requirement of table 300-2 including cost, conveyance, royality of all materials & cost of all labour, machinery etc complete as per approved Drawing & Technical Specifications and Clause -305 of MoRT&H Specifications for Road & Bridge works (5th Revision).Sevayat Bhawan (1NOS-6SH)
63Sevayat Bhawan (1NOS-10SH)
64Sevayat Bhawan (3NOS-13SH)
65Sevayat Bhawan (1NOS-17SH)
66RETAINING WALL & TOE WALL
67RAIN SHED. (4 Nos)
68PILLERED HALL. (4 Nos)
69RUDRAVISEK HALL WITH KITCHEN & STORE
70Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. Column base & footingSevayat Bhawan (1NOS-6SH)
71Sevayat Bhawan (1NOS-10SH)
72Sevayat Bhawan (3NOS-13SH)
73Sevayat Bhawan (1NOS-17SH)
74RETAINING WALL & TOE WALL
75RAIN SHED. (4 Nos)
76PILLERED HALL. (4 Nos)
77RUDRAVISEK HALL WITH KITCHEN & STORE
78PLINTH BEAMSevayat Bhawan (1NOS-6SH)
79Sevayat Bhawan (1NOS-10SH)
80Sevayat Bhawan (3NOS-13SH)
81Sevayat Bhawan (1NOS-17SH)
82ENTRANCE GATEWAY.(4 Nos)
83RAIN SHED. (4 Nos)
84PILLERED HALL. (4 Nos)
85RUDRAVISEK HALL WITH KITCHEN & STORE
86COLUMNSevayat Bhawan (1NOS-6SH)Ground Floor
87Sevayat Bhawan (1NOS-10SH)
88Sevayat Bhawan (3NOS-13SH)
89Sevayat Bhawan (1NOS-17SH)
90ENTRANCE GATEWAY.(4 Nos)
91RAIN SHED. (4 Nos)
92PILLERED HALL. (4 Nos)
93RUDRAVISEK HALL WITH KITCHEN & STORE
94ROOF BEAMSevayat Bhawan (1NOS-6SH)Ground Floor
95Sevayat Bhawan (1NOS-10SH)
96Sevayat Bhawan (3NOS-13SH)
97Sevayat Bhawan (1NOS-17SH)
98ENTRANCE GATEWAY.(4 Nos)
99RAIN SHED. (4 Nos)
100PILLERED HALL. (4 Nos)
101RUDRAVISEK HALL WITH KITCHEN & STORE
102LINTEL BANDSevayat Bhawan (1NOS-6SH)Ground Floor
103Sevayat Bhawan (1NOS-10SH)
104Sevayat Bhawan (3NOS-13SH)
105Sevayat Bhawan (1NOS-17SH)
106RUDRAVISEK HALL WITH KITCHEN & STORE
107ROOF SLABSevayat Bhawan (1NOS-6SH)Ground Floor
108Sevayat Bhawan (1NOS-10SH)
109Sevayat Bhawan (3NOS-13SH)
110Sevayat Bhawan (1NOS-17SH)
111ENTRANCE GATEWAY.(4 Nos)
112RAIN SHED. (4 Nos)
113PILLERED HALL. (4 Nos)
114RUDRAVISEK HALL WITH KITCHEN & STORE
115RCC WALLRETAINING WALL & TOE WALL Ground Floor
116STAIRCASERETAINING WALL & TOE WALL Ground Floor
117CHAJJASevayat Bhawan (1NOS-10SH)Ground Floor
118Sevayat Bhawan (1NOS-10SH)
119Sevayat Bhawan (3NOS-13SH)
120Sevayat Bhawan (1NOS-17SH)
121RUDRAVISEK HALL WITH KITCHEN & STORE
122R.C.C. work of M-20 in following works using 12 mm. to 20 mm. (½” to ¾”) size (20 mm. not to exceed 25%) hard black crusher broken granite stone chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per the direction of the Engineer-in-charge. Column base & footingDRAINAGE SYSTEM (600X600 & 300X300) size Except (300X300) size slab
123Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding, wastage & over lapping and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.Sevayat Bhawan (1NOS-6SH)Ground Floor
124Sevayat Bhawan (1NOS-10SH)
125Sevayat Bhawan (3NOS-13SH)
126Sevayat Bhawan (1NOS-17SH)
127RETAINING WALL & TOE WALL
128ENTRANCE GATEWAY.(4 Nos)
129RAIN SHED. (4 Nos)
130PILLERED HALL. (4 Nos)
131RUDRAVISEK HALL WITH KITCHEN & STORE
132DRAINAGE SYSTEM (600X600 & 300X300) size
133Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.Sevayat Bhawan (1NOS-6SH)
134Sevayat Bhawan (1NOS-10SH)
135Sevayat Bhawan (3NOS-13SH)
136Sevayat Bhawan (1NOS-17SH)
137RAIN SHED. (4 Nos)
138PILLERED HALL. (4 Nos)
139RUDRAVISEK HALL WITH KITCHEN & STORE
140Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.Sevayat Bhawan (1NOS-6SH)Ground Floor
141Sevayat Bhawan (1NOS-10SH)
142Sevayat Bhawan (3NOS-13SH)
143Sevayat Bhawan (1NOS-17SH)
144RUDRAVISEK HALL WITH KITCHEN & STORE
145Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge..Sevayat Bhawan (1NOS-6SH)Ground Floor
146Sevayat Bhawan (1NOS-10SH)
147Sevayat Bhawan (3NOS-13SH)
148Sevayat Bhawan (1NOS-17SH)
149RUDRAVISEK HALL WITH KITCHEN & STORE
150Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.Sevayat Bhawan (1NOS-6SH)Ground Floor
151Sevayat Bhawan (1NOS-10SH)
152Sevayat Bhawan (3NOS-13SH)
153Sevayat Bhawan (1NOS-17SH)
154ENTRANCE GATEWAY.(4 Nos)
155RAIN SHED. (4 Nos)
156PILLERED HALL. (4 Nos)
157RUDRAVISEK HALL WITH KITCHEN & STORE
158Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Sevayat Bhawan (1NOS-6SH)Ground Floor
159Sevayat Bhawan (1NOS-10SH)
160Sevayat Bhawan (3NOS-13SH)
161Sevayat Bhawan (1NOS-17SH)
162PILLERED HALL. (4 Nos)
163RUDRAVISEK HALL WITH KITCHEN & STORE
164Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.Sevayat Bhawan (1NOS-6SH)Ground Floor
165Sevayat Bhawan (1NOS-10SH)
166Sevayat Bhawan (3NOS-13SH)
167Sevayat Bhawan (1NOS-17SH)
168RETAINING WALL & TOE WALL
169ENTRANCE GATEWAY.(4 Nos)
170RAIN SHED. (4 Nos)
171PILLERED HALL. (4 Nos)
172RUDRAVISEK HALL WITH KITCHEN & STORE
173Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.Sevayat Bhawan (1NOS-6SH)Ground Floor
174Sevayat Bhawan (1NOS-10SH)
175Sevayat Bhawan (3NOS-13SH)
176Sevayat Bhawan (1NOS-17SH)
177ENTRANCE GATEWAY.(4 Nos)
178RAIN SHED. (4 Nos)
179PILLERED HALL. (4 Nos)
180RUDRAVISEK HALL WITH KITCHEN & STORE
181Supplying, fitting and fixing vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm (Plain Ivory) of approved make (JOHNSON /RAK / SOMANY/ KAJARIA) in floors on 20mm thick bed of C.M. (1:4) (1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tile including cost of all materials, labour, labour cess, T&P etc. required for the work complete in all respect as directed by the Engineer in charge.Sevayat Bhawan (1NOS-6SH)Ground Floor
182Sevayat Bhawan (1NOS-10SH)
183Sevayat Bhawan (3NOS-13SH)
184Sevayat Bhawan (1NOS-17SH)
185RUDRAVISEK HALL WITH KITCHEN & STORE
186Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm plain (Ivory) of approved make (JOHNSON / RAK/ KAJARIA/ SOMANY) as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects as directed by the Engineer in charge.Sevayat Bhawan (1NOS-6SH)Ground Floor
187Sevayat Bhawan (1NOS-10SH)
188Sevayat Bhawan (3NOS-13SH)
189Sevayat Bhawan (1NOS-17SH)
190RUDRAVISEK HALL WITH KITCHEN & STORE
191Fixing of Kota tiles of minium thickness 16mm thick of premium grade of size above 0.10 Sqm. in floors over 20mm thick bed of cement mortar 1:4 (1cement:4course sand)and filling the joint with white cement mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, royalties of all materials, labour,labour cess with T&P complete in all respects as per direction of Engineer-in-Charge..Sevayat Bhawan (1NOS-6SH)
192Sevayat Bhawan (1NOS-10SH)
193Sevayat Bhawan (3NOS-13SH)
194Sevayat Bhawan (1NOS-17SH)
195Providing and fixing ISI marked 35 mm thick flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete as directed by Engineer-in-charge.Sevayat Bhawan (1NOS-6SH)Ground Floor
196Sevayat Bhawan (1NOS-10SH)
197Sevayat Bhawan (3NOS-13SH)
198Sevayat Bhawan (1NOS-17SH)
199RUDRAVISEK HALL WITH KITCHEN & STORE
200Supplying fitting and fixing of two track UPVC sliding window / ventilator of approved make with 6mm thick glass of approved quality complete with frame, shutter and all fitting and fixtures etc. complete as per specification & direction of Engineer-in-charge.Sevayat Bhawan (1NOS-6SH)Ground Floor
201Sevayat Bhawan (1NOS-10SH)
202Sevayat Bhawan (3NOS-13SH)
203Sevayat Bhawan (1NOS-17SH)
204RUDRAVISEK HALL WITH KITCHEN & STORE
205Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge.Sevayat Bhawan (1NOS-6SH)Ground Floor
206Sevayat Bhawan (1NOS-10SH)
207Sevayat Bhawan (3NOS-13SH)
208Sevayat Bhawan (1NOS-17SH)
209ENTRANCE GATEWAY.(4 Nos)
210RUDRAVISEK HALL WITH KITCHEN & STORE
211DRAINAGE SYSTEM (300X300) size
212Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).Sevayat Bhawan (1NOS-6SH)Ground Floor
213Sevayat Bhawan (1NOS-10SH)
214Sevayat Bhawan (3NOS-13SH)
215Sevayat Bhawan (1NOS-17SH)
216ENTRANCE GATEWAY.(4 Nos)
217RUDRAVISEK HALL WITH KITCHEN & STORE
218PARKING, PATHWAY AND ROUND ABOUT
219Painting two coats with plastic emulsion paint with a approved quality primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).Sevayat Bhawan (1NOS-6SH)Ground Floor
220Sevayat Bhawan (1NOS-10SH)
221Sevayat Bhawan (3NOS-13SH)
222Sevayat Bhawan (1NOS-17SH)
223RAIN SHED. (4 Nos)
224PILLERED HALL. (4 Nos)
225RUDRAVISEK HALL WITH KITCHEN & STORE
226Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge) Sevayat Bhawan (1NOS-6SH)Ground Floor
227Sevayat Bhawan (1NOS-10SH)
228Sevayat Bhawan (3NOS-13SH)
229Sevayat Bhawan (1NOS-17SH)
230RETAINING WALL & TOE WALL
231ENTRANCE GATEWAY.(4 Nos)
232RAIN SHED. (4 Nos)
233PILLERED HALL. (4 Nos)
234RUDRAVISEK HALL WITH KITCHEN & STORE
235Wall painting two coats with weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).Sevayat Bhawan (1NOS-6SH)Ground Floor
236Sevayat Bhawan (1NOS-10SH)
237Sevayat Bhawan (3NOS-13SH)
238Sevayat Bhawan (1NOS-17SH)
239RETAINING WALL & TOE WALL
240PILLERED HALL. (4 Nos)
241RUDRAVISEK HALL WITH KITCHEN & STORE
242Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. Sevayat Bhawan (1NOS-6SH)Ground Floor
243Sevayat Bhawan (1NOS-10SH)
244Sevayat Bhawan (3NOS-13SH)
245Sevayat Bhawan (1NOS-17SH)
246ENTRANCE GATEWAY.(4 Nos)
247RAIN SHED. (4 Nos)
248PILLERED HALL. (4 Nos)
249RUDRAVISEK HALL WITH KITCHEN & STORE
250Supplying and fixing of Pre cast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect confirming to IS 5758:1984 s directed by the Engineer-in-charge.PARKING, PATHWAY AND ROUND ABOUT Ground Floor
251R.R.H.G. Stone Masonry in cement mortar (1:4) in foundation & plinth using R.R.H.G. Stone of approved quality from approved quarry, watering, curing etc. complete including cost, conveyance, royalties, taxes of all materials, cost of all labour, all T&P etc. complete in all respect as directed by the Engineer-in-charge.FILLING & STONE PITCHINGGround Floor
252Construction of granular sub-base by providing close graded granular sub base Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, & compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT & H Specifications for Road & Bridge works (4th Revision) A.R.Page-160 & Item no.39PARKING, PATHWAY AND ROUND ABOUTGround Floor
253Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with storng vibratory compaction of approved size, design & shape, laid in required colour and pattern over and including 50mm thick sand filling.as per drawing, specification and direction of Engineer-In-charge. PARKING, PATHWAY AND ROUND ABOUTGround Floor
254Providing and fixing 25mm thick Khandolite stone Cladding (sample of Khandolite stone should be approved by Engineer-In-Charge) for Temple External & Internal Wall and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 12mm. thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) with joints treated with white coment mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc.complete as per direction of Engineer-in-charge. In all floors and all heights.Sevayat Bhawan (1NOS-6SH)Ground Floor
255Sevayat Bhawan (1NOS-10SH)
256Sevayat Bhawan (3NOS-13SH)
257Sevayat Bhawan (1NOS-17SH)
258RETAINING WALL & TOE WALL
259ENTRANCE GATEWAY.(4 Nos)
260RAIN SHED. (4 Nos)
261PILLERED HALL. (4 Nos)
262RUDRAVISEK HALL WITH KITCHEN & STORE
263Providing and fixing 50mm thick Khandolite stone Flooring(sample of Khandolite stone should be approved by Engineer- In-Charge) for Temple External & Internal Wall and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in- charge. In all floors and all heights.RETAINING WALL & TOE WALL Ground Floor
264PARIKRAMA
265RAIN SHED. (4 Nos)
266PILLERED HALL. (4 Nos)
267RUDRAVISEK HALL WITH KITCHEN & STORE
268Dressed & Carved pieces in required size of minimum thickness of 150mm with carving work upto depth of 50mm.ENTRANCE GATEWAY.(4 Nos)
269RAIN SHED. (4 Nos)
270PILLERED HALL. (4 Nos)
271Manufacturing, Providing & Installation of GFRC jalli incorporating Jali & Baluster (Glass Fiber Reinforced Concrete), Make Samudyam with Pattern, design, and colour of approved make to be fixed on structural work with Dry Fixing method with appropriate SS Pipe & Cleats frame work, using fasteners, and necessary hardware etc. The element shall be made from '53 grade' Portland Cement make Birla/ 'JK Cement' or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass fibre make 'Owens Corning' or equivalent, Super plasticizers / Additives make by 'BASF' or equivalent, Polymers make 'BASF' or equivalent and U.V resistant Synthetic inorganic pigments shall be used for pigmentation make 'BAYFERROX (Germany)' or equivalent. The material casting shall take place in Synthetic Rubber / FRP Mould manufactured by Mould / Tool / Mould Grade Resin of Revex/ 'Reckli' or equivalent.• JALI : Size of 1925 x 1000 MM : 1 NosRETAINING WALL & TOE WALL
272Sevayat Bhawan (1NOS-6SH)
273Sevayat Bhawan (1NOS-10SH)
274Sevayat Bhawan (3NOS-13SH)
275Sevayat Bhawan (1NOS-17SH)
276Providing Weep Holes of 100mm dia using A.C./ PVC pipe, fixing with cement mortar including cost, conveyance, royality of all materials & cost of all labour etc complete as per approved Drawing & Technical Specifications and Clause -2706 & 2200 of MoRT&H Specifications for Road & Bridge works (5th Revision).RETAINING WALL & TOE WALL
277Waterproofing application: Providing and application of two component polymer modified flexible cementitious Waterproofing application: Providing and application of two waterproofing coating at a thickness of 1.5-2.5 mm The membrane should have Elongation equal or more than: 30%Crack Bridging ability: Up to 1 mmAdhesive strength: 1.0 N/mm² @ 280Tensile elongation: 60% @ 20°CShore A Hardness >85 (between 3-7 daysetc. as per direction of E.LC (For longer span, in terrace panel of 4m*4m should be done by groove cutting, and filling with PU Sealant)Sevayat Bhawan (1NOS-6SH)Ground Floor
278Sevayat Bhawan (1NOS-10SH)
279Sevayat Bhawan (3NOS-13SH)
280Sevayat Bhawan (1NOS-17SH)
281ENTRANCE GATEWAY.(4 Nos)
282RAIN SHED. (4 Nos)
283PILLERED HALL. (4 Nos)
284RUDRAVISEK HALL WITH KITCHEN & STORE
285Dismantling and removing R.C.C. columns beams slab staircase landing lintels including stacking the useful materials for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.PARIKRAMA
286Dismantling brick or stone masonry in lime or cement mortar above 3m height including stacking the useful materials for re-use and removing the debris with in 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.PARIKRAMA
287Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.PARIKRAMA
288Dismantling & Removing cement concrete including stacking the useful materials for reuse and removing the debris within 50m lead with cost of all labour etc. complete as directed by the Engineer in charge.PARIKRAMA
289Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris within 50m lead with cost of all labour etc. complete as directed by the Engineer in charge.PARIKRAMA
290Dismantling and removing old cladding from walls including racking out joints 12mm deep stacking the useful materials for reuse and removing the debris within 50m lead with cost of all labour etc. complete as directed by the Engineer in charge.PARIKRAMA
291E.I. WORKRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/ legrand( Myrius) / Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/ legrand( Myrius) / Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. Each lightpoint should have provision for ceiling rose and angle holder point.NB:All the electrical,Fire fighting,HVAC,ELV drawings,LUX Level design of the lighting, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work.GROUP-A
292GROUP-B
293GROUP-C
294Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/ legrand( Myrius) / Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
295Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) ((flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/ legrand( Myrius ) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
296Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider(Zencelo)/ legrand( Myrius)/ Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
297Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor /Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
298Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor /Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT) (2X2.5+1X1.5)
299Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor /Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
300Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor /Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 4 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit (2X6+1X4)
301Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor /Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (4X6+2X4)
302Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor /Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit . (4X10+2X6)
303Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/ Siemens/ Legrand/ ABBc of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
304Supplying,fixing of 2 nos 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider(Zencelo)/ legrand( Myrius) / Panasonic (vision). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
305Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
306S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
307S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/ legrand( Myrius)/ Panasonic (vision)
308Sub-Head II (Light fitting Fixture & Fan) :-Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/ Crompton/ Usha/ Orient/ Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
309Supply, Installation, Testing and Commissioning of Duct mounted Single skinned Circular Inline Centrifugal Fan for Toilet Ventilation with direct driven Backward-curved impellers.The Fan has external rotor motor suitable for 1~, 230V, 50 Hz power supply. MAKE - SYSTEMAIR/ GREENHECK/ ELTA/Airflow6000 CFM @ 15mm MMWG static pressure
310Supply & Fixing of Air Distribution Duting fabricated with Class VI GI Sheet(180 GSM) Complete With Supports, dampers, guiding vanes, access doors, MS Angle, Fire inhibiting gaskets, Nuts, bolts and all oyher accessories in accordance with approved drawing and the Specification. (Make:- Jindal/ Sail/ Tata)22 gauge (0.80 mm thickness)
31124 gauge (0.63 mm thickness)
312Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser without VCD having flange all around.Make-Glenstorm/Airflow/Systemaire
313Supply, Installation, Testing and Commissioning of bird screen made by stain less steel for fans
314Supplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix /Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.
315Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
316SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
317SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
318Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
319SITC of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/ LT/ Havells / Philips/ Wipro/ Crompton/ Bajaj) . The luminaire must be Replacement Warranty will be 5 years.
320BDBS,DB,AC DB,FLOOR PANELS,MCBS :-Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator).Warranty on DB is 3 years (2 toilet,ups mandap,ups IPC,REST, SEVAK HOUSE)
3214 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (FOR LDB IPC,MANDAP,BD REST,DB CAFT.)
3228 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR POWER & INDOOR AC DB)Warranty on DB is 3 years (FOR PDB IPC,MANDAP,.)
323Supplying and fixing 6- 32 amps rating, 240 volts, C series, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years .
324Supplying and fixing 32 Amps rating,C series,10KA breaking capacity, 2P, 230 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year
325Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 . the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years.
326Supplying and fixing 40Amps 4P 415 volts, MCB, C series, 10 kA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years
327Supplying and fixing 40 Amps rating, RCCB 30mA 4P . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year.
328Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year.
329Supplying and fixing 63Amps 4P 415 volts MCB 415 volts, C series,10KA breaking capacity, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB with connections as per direction of Engg.-in-Charge..Warranty on MCB is 3 years.
330Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 1 year.
331Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 230 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year
332CABLING AND END TERMINATION MAIN AREA :-Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 4core x 16 sq mm ALL DB FOR SMALL BUILDING TPN
3333.5core x 150 sq mm
3343.5core x 95 sq mm EV,ALL INDIVIDUAL BUILDING IPC,DG)
3353.5core x 50 sq mm (EV,MANDAP PANEL)
3363.5core x300 sq mm (MAIN CABLE)
337LAYING OF CABLE :-Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
338Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
339Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
340Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
341Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge.
342Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
343Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
344Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. Supplying and making end termination with 4 core x16 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
345Supplying and making end termination with 3.5 core x95 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
346Supplying and making end termination with 3.5 core x150 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
347Supplying and making end termination with 3.5 core x50 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
348Supplying and making end termination with 3.5 core x300 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
349Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 50 mm dia
350Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster )
351Supplying,laying of 3cx2.5 sq.mm AL armoured XLPE cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster )
352Supplying,laying of 3cx6 sq.mm AL. armoured XLPE cable with insulated cover with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials(make-Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster )
353Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.50 mm dia
354PANELS MAIN CONTROL PANEL NEAR INTP. HALL AREA :-S/I/T&Commissioning of LT OUTDOOR floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 1+2 SPD 50 kA/Pole with 600A HRC backup fuse shall be installed in the incomer. 80X10MM Separate Aluminium Earth bus bar should be installed.Provision of cable alley chamber is mandatory. All the feeders shall have ON/OFF/TRIP indication.In commer-1-01 number of 630A 4P Icu=100%Ics,36Ka LSIG MCCB with microprocessor release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.In commer-2- 01 number of 200A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.Changeover- 01 no of 200A 4P onload changeover switch ( DG 01 NO)(Make-Legrand/Siemens/Schneider/ABB).Busbar-1&2 04 numbers of 800Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing).Out going- 01 numbers of 200 Amps 4P MCCB.Icu=100%Ics,25Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.Out going- 02 numbers of 125Amps 4P MCCB.Icu=100%Ics,25Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.Out going- 02 numbers of 160Amps 4P MCCB.Icu=100%Ics,25Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.Out going- 12 numbers of 100-63Amps 4P MCCB.Icu=100%Ics,16Ka TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.Out going- 1 number of 100Amps 4P MCCB Motorized .Icu=100%Ics,25Ka ,LSING ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula for Solar on grid integrate .Outgoing- 4 nos. 32A 4P MCB, C series, 10 ka , Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200.Outgoing- 8 nos. 32A 2P MCB, C series, 10 ka , Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200(Among it 2 nos with space for KWH Meter for shop)Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication(iii) All the MCCB outgoing feeders shall have digital ammeter with CT of suitable class 1 rating.(Make-Legrand/Siemens/Schneider/ABB).
355MAIN CONTROL PANEL TEMPLE :-S/I/T&Commissioning of LT INDOOR floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.Provision of cable alley chamber is mandatory.All the feeders shall have ON/OFF/TRIP indication.In commer-1-01 number of 160A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.In commer-2-01 number of 125A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.Changeover- 01 no of 125A 4P onload changeover switch ( DG 01 NO)(Make-Legrand/Siemens/Schneider/ABB).Busbar-1&2 04 numbers of 300Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing).Out going- 6 numbers of 6-32A 2P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200).Out going- 4 numbers of 6-32A 4P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200).Out going- 8 numbers of 63A 4P MCCB16KA TMR based, Ics=100%Icu ( Make-LEGRAND-DPX3/ Siemens-3VA/ Schneider- CVS/ABB FORMULA).Out going- 8 numbers of 40A 4P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication iii) 3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. (Make of SPD-Legrand/Siemens/Schneider/ABB),Make of MCB-LEGRAND-DX3 / Siemens-Betaguard Model/ Schneider-Acti-9 /ABB SB200.
356MAIN CONTROL PANEL HOUSE 18 nos.:-S/I/T&Commissioning of CPRI tested LT OUTdoor floor mounted double door with provision of padlock Metering electrical main METERING panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.Provision of cable alley chamber is mandatory.All the feeders shall have ON/OFF/TRIP indication.In commer-1-01 number of 100-63A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.Busbar-1&2 04 numbers of 200Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing).Out going- 18 numbers of 6-32A 2P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) with space for 18 nos 10-100A 1PH KWH Meter digital type for each house.Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication (iii) 3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. (Make of SPD-Legrand/Siemens/Schneider/ABB),Make of MCB-LEGRAND-DX3 / Siemens-Betaguard Model/ Schneider-Acti-9 /ABB SB200.
357MAIN CONTROL PANEL HOUSE 14 nos. :-S/I/T&Commissioning of CPRI tested LT OUTdoor floor mounted double door with provision of padlock Metering main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.Provision of cable alley chamber is mandatory.All the feeders shall have ON/OFF/TRIP indication.In commer-1-01 number of 100-63A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula.Busbar-1&2 04 numbers of 200Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing).Out going- 14 numbers of 6-32A 2P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) with space for 14 nos 10-100A 1PH KWH Meter digital type for each house.Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication (iii) 3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. (Make of SPD-Legrand/Siemens/Schneider/ABB),Make of MCB-LEGRAND-DX3 / Siemens-Betaguard Model/ Schneider-Acti-9 /ABB SB200.
358CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER :-Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
359UPS :-Supply ,installation ,testing & commissioning of 10 KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 1 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 42AH, 20 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC/ Vertiv/) , as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD. for IPC building
360EARTHING :-Supplying,installation,testing & commissioning Of Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required as per direction of Engg. in charge.
361Supplying & laying of 6 swg GI WIRE at 0.5m below the ground as strip earth electrode including connection/termination with nut ,bolt ,spring washer etc as required(jointing shall be done by over laping and with 2 sets of brass nut ,bolt & spring washer spaced at 50mm . as required as per direction of Engg. in charge.
362Supplying & laying of 25mm x 5 mm GI strip at 0.5m below the ground as strip earth electrode including connection/termination with nut ,bolt ,spring washer etc as required(jointing shall be done by over laping and with 2 sets of brass nut ,bolt & spring washer spaced at 50mm . as required as per direction of Engg. in charge.
363LIGHT SYSTEM EXTERNAL :-Supply, Installation, testing & commissioning of 7 meter long aesthetically designed Single Arm decorative lighting pole with 1.2 mtr height Cast Iron base, cast aluminium ring on the middle portion and Trishul on the top. Pole shall be made up of Mild Steel Body and coated with zinc rich primer & pure polyester powder coating of Antique Copper finish. Bottom dia of the pole will be Ø114.3mm or higher & top decorative arm portion having dia of Ø60 mm or higher and having base Plate of size Ø280 x16mm thick with provision for founation bolt. Pole is Compatible for Ø70mm size for cable entry & exist. Junction Box service door is made up cast aluminium and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 32A 4pole terminal connector for loop-in loo-out arrangement with all materials & labour as required as per the direction of Engineer-in- Charge. (Make: K -lite Pelican Mini Orna Trishul Carolina Pole KP-12037-700-SA or, similar to Jaquar/Bajaj/Reytek/Homdec).
364Supply, Installation, testing & commissioning of 7 meter long aesthetically designed Double Arm decorative lighting pole with 1.2 mtr height Cast Iron base, cast aluminium ring on the middle portion and Trishul on the top. Pole shall be made up of Mild Steel Body and coated with zinc rich primer & pure polyester powder coating of Antique Copper finish. Bottom dia of the pole will be Ø114.3mm & top decorative arm portion having dia of Ø60 mm and having base Plate of size Ø280 x16mm thick with provision for founation bolt. Pole is Compatible for Ø70mm size for cable entry & exist. Junction Box service door is made up cast aluminium and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 32A 4pole terminal connector for loop-in loo-out arrangement with all materials & labour as required as per the direction of Engineer-in- Charge. (Make: K -lite Pelican Mini Orna Trishul Carolina Pole KP-12037-700-DA or, similar to Jaquar/Bajaj/Reytek/Homdec).
365Supply, Installation, testing & commissioning of 100W LED Pendent light having Extruded aluminium with Spun Aluminium Top housing and coated with zinc rich primer & pure polyester powder coating of Antique Copper Finish, UV Stabilized Translucent Acrylic diffuser and suitable for mounting on 60 mm OD pipe. CCT-3000K, CRI-≥70, IP-65, IK-07, SDCM≤ 3, Lumen maintainance >60,000 burning hours as per L70 B10, Power Factor : >0.95, THD : <10%, Surge Protection : Inbuilt 6KV, Efficiency : >85%, Optical Distribution :120degree. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite Pelican KL-26799 or, similar to Jaquar/Bajaj/Reytek/Homdec).
366Construction of RCC foundation by using M20 grade RCC and Fe 415 grade reinforcement in the foundation by considering the SBC as 10 T per sq mtr and fixing the 4 nos. fdn bolts in that foundation for installation of pole with street light on that foundation(Details Drawing of the foundation attached). The work shall be excuted as per the direction of EIC.The structural calculation, wind load calculation and civil foundation shall be duly approved by the competent authority from civil wing (SE/CCE/Competant authority)before execution of the work.
367Supply , Installation, testing & commissioning of 24W LED Vista Bollard light of Dimension: Ø250 x 900mm having Spun Aluminium with Extruded Aluminium Tube(Grade 6063) housing and coated with zinc rich primer & pure polyester powder coating of Antique Copper Finish, UV Stabilized Translucent Polycarbonate diffuser. Bollard should be Customized Bespoke CNC cutting design with CCT-3000K, CRI-≥80, IP-65, IK-08, SDCM≤ 3, Lumen maintainance >60,000 burning hours as per L70 B10, Power Factor : >0.9, THD : <10%, Surge Protection : Inbuilt 4KV, Efficiency : >80%, Optical Distribution : Symmetrical. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66/65 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite Vista Bollard 24572 or, , similar to Jaquar/Bajaj/Reytek/Homdec).
368Installation of Bollard Light by making the suitable size foundationwith necessary civil work and fixing the bollard light equievalant make ISI marked as approved as per direction of Engg. in Charge.
369Supply , Installation, testing & commissioning of 12W LED step light of Dimension : 255mm x 87mm x 76mm and having die-cast aluminium housing and coated with zinc rich primer & pure polyester powder coating of Jet Black Finish, UV Stabilized Satin Acrylic diffuser. CCT-3000K, CRI-≥70, IP-65, IK-09, SDCM≤ 3, Lumen maintainance >60,000 burning hours as per L70 B10, Power Factor : >0.95, THD : <10%, Surge Protection : Inbuilt 6KV, Efficiency : >85%, Optical Distribution :120degree. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite Sudo KL-22525 Luminaries or, similar to Jaquar/Bajaj/Reytek/Homdec).
370Supply, Installation, testing & commissioning of 9W LED Inground Bourial light of Dimension: Ø116X153 having die-cast aluminium housing and with SS Top ring , UV Stabilized Toughened Glass diffuser. CCT-3000K, CRI-≥70, IP-67, IK-08, SDCM≤ 3, BA-25deg, Lumen maintainance >60,000 burning hours as per L70 B10, Power Factor : >0.95, THD : <10%, Surge Protection : Inbuilt 4KV, Efficiency : >85%, Optical Distribution :Asymmetrical. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite In-Ground Bourial 21790 Luminaries or, similar to Jaquar/Bajaj/Reytek/Homdec).
371Supply , Installation, testing & commissioning of 60W LED Focus Light having die-cast aluminium housing and coated with zinc rich primer & pure polyester powder coating of Jet Black Finish, UV Stabilized Clear toughened glass diffuser. CCT-3000K, CRI-≥70, IP-65, IK-06, SDCM≤ 3, Lumen maintainance >60,000 burning hours as per L70 B10, Power Factor : >0.95, THD : <10%, Surge Protection : Inbuilt 4 KV, Efficiency : >80%, Optical Distribution :45 degree beam angle. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite Iyra KL-22561 Luminaries or, similar to Jaquar/Bajaj/Reytek/Homdec).
372Supply , Installation, testing & commissioning of 36W LED Linear wall washer Light of dimenssion must be 1000X85X38 having 6063 Aluminium Alloy housing with UV Stabilized Clear toughened glass diffuser. CCT-3000K, CRI-≥70, IP-66, IK-05, Lumen maintainance >50,000 burning hours as per L70 B10, Optical Distribution :12 degree beam angle. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite KL-23068 Luminaries or, similar to Jaquar/Bajaj/Reytek/Homdec).
373Supply , Installation, testing & commissioning of 9W/MTR LED Neon Flex having Copper Coated Strip body, UV Stabilized Silicone Moulded diffuser. CCT-3000K, CRI-≥80, IP-65, SDCM≤ 3, Lumen maintainance >50,000 burning hours as per L70 B10, 24V DC, Power Factor : >0.95, THD : <10%, Surge Protection : Inbuilt 6KV, Efficiency : >85%, Optical Distribution :120degree. Flex to be provided with required IP67 driver and SS Chanel for installation. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite Niva KL-23224 Luminaries or, similar to Jaquar/Bajaj/Reytek/Homdec).
374Supply , Installation, testing & commissioning of IP67 150W 24V DC Driver.
375SITC of IP 68 T connector
376CABLING :-Supplying and laying of one number PVC insulated armoured and PVC sheathed XLPE AL. conductor power cable of 1.1 KV grade POLYCAB/FINOLEX/HAVELLS/KEI/RR Kabel/Gloster of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.4core x 16 sq mm (OFP TO IND. TIMER PANEL)
3774 core x 4 sq mm (for small power/LIGHT TO POLE)
378Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
379Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. Supplying and making end termination with 4 core x16 sq mm brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
380Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. Make-POLYCAB/FINOLEX/HAVELLS/KEI/RR Kabel/Gloster
381Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.50 mm dia
382S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials
383Highmast lighting :-Supply of 9meter long Minimast light pole made up of Mild Steel Body and coated with zinc rich primer & pure polyester powder coating and finished with black colour. The pole shall be suitable for fitting of 6nos of 3 X 60W LED Flood Light. Pole having body size of Bottom dia Ø155mm and top dia will be Ø76mm and on the top Hexa gonal design arrangement should be there to fix flood light. The Pole shall have base Plate □300x16mm thick with provision for founation bolt fittings. Pole is Compatible for 70mm size for cable entry & exist. Junction Box service door is made up cast aluminium of size 325 X 90mm and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 4pole studd connector for loop-in loo-out arrangement with all materials & labour as required as per the direction of Engineer-in- Charge.(Make: K -lite Pole (Make: K -lite Pole KP-12068 similar to Jaquar/Bajaj/Homdec)
384Supply of 180W(3X60W) LED Focus light having die-cast aluminium housing and coated with zinc rich primer & pure polyester powder coating of Jet Black Finish, UV Stabilized Clear toughened glass diffuser. CCT-3000K, CRI-≥70, IP-65, IK-06, SDCM≤ 3, Lumen maintainance >60,000 burning hours as per L70 B10, Power Factor : >0.95, THD : <10%, Surge Protection : Inbuilt 6KV, Efficiency : >85%, Beam Angle :12degree. The lighting manufactor must have own NABL Approved lab to justify the lumen efficacy, IP-66 protection and other parameters as required by the Engineer-in- Charge. (Make: K -lite Aston 26798 similar to Jaquar/Bajaj/Homdec).
385Solar light :-Supply of Elegant look 60 W AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more (subjected to final panel backup calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 78 Ah or more (subjected to final battery calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor( when there will be no movement the lumens output will be 30% output).The solar panel and battery should be designed to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of >=10000 lumens as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central/state govt accredited NABL lab reports to justify the lumen efficacy,luminaire output , IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR for the technical acceptance of the products.1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) , 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) , 3. IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 – MPPT Efficiency , 5. IEC61547 , 6. IEC61000-3-2 – EMC , 7. IEC 60598-2-3 ,8. IEC 62109-1, ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar light )Make-(Philips/Panasonic/Wipro/Crompton/Bajaj/Havells/LT ). NB: The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect.
386Supply of 8 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 155 MM A/F of 4 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge.
387Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge.
388Installation of 60W AIO LED solar street light on 8 mtr octagonal pole.
389ELV-CCTV ,PA SYSTEM :-SITC of 5MP IP Bullet/Dome Camera with inbuilt microphone, equipped with 1/2.7\\" Progressive Scan CMOS image sensor and 3.6/2.8(for dome) mm fixed lens, supporting a resolution of 2592 × 1944 or higher. The camera shall provide IR illumination up to 30 meters and an approximate field of view of 79° (H)/97(for dome), 56°/70(for dome) (V), and 106°/128( for dome) (Diagonal). Minimum illumination shall be 0.003 lux @ F1.6 (AGC ON) with support for WDR (120 dB). The camera shall support video compression formats such as H.265+, H.265, H.264+, H.264 and MJPEG, with multiple streaming capability including main stream up to 5MP @ 30 fps, sub-stream up to 1080p @ 30 fps, and additional third stream. The camera shall support intelligent analytics such as human and vehicle detection, perimeter intrusion detection, line crossing detection, object detection, heat map, crowd density detection, queue length detection, and rare sound detection. The device shall support motion detection with multiple configurable zones and network protocols including TCP/IP, HTTP, DHCP, RTP/RTSP, SMTP, NTP, UPnP, SNMP, HTTPS and SFTP, and shall be ONVIF compliant (Profile S/G/T). The camera shall include micro SD card slot up to 256 GB/512 GB( for dome), privacy masking, ICR auto day/night switching, and support 12V DC or PoE power supply. The housing shall be metal body with IP67 weatherproof protection, suitable for outdoor installation. The product shall comply with NDAA requirements and shall be certified with STQC, BIS, CE, FCC and RoHS. Make-Honeywell Value series/Pelco/Axis/Bosch
390Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR motorized Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 70m(bullet)/50m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.7-13.5mm motorized, Field of View FoV H:100-28.5°, V:73-21.4°, BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell value series/Pelco/Axis/Bosch
391Supply , Installation, testing , commissioning of 64 Channel NVR with 8 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS). Make-Honeywell value series/ Pelco/ Axis/ Bosch
392Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba
393SITC of Certified HDMI® Interface Cable, 18 Gbps, 15 m Makes: Honeywell, Extron, Kramer
394SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony
395SITC of outdoor type double jacketed 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit
396SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit
397SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit
398SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit
399SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax/ Legrand/ Panduit
400SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax/ Legrand/ Panduit(1 mtr length)
401SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax/ Legrand/ Panduit (2 mtr length)
402SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco/ Digisol/ Netgear
403SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax/ Legrand/ Panduit
404SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax/ Legrand/ Panduit
405SITC of 9U/500D outdoor type IP 55 Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make: Valrack/ Rittal/ Legrand
406SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand
407SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP,Netgear
408PA SYSTEM :-Supply of 20 Watt outdoor Horn Speaker, IP65, Frequency Response : 150 Hz – 15 kHz, 4 INCH DRIVER, peak power handling capacity 80W, Should have Passive 350 Hz high-pass filter built-in, SPL : 133 dB peak @ 1.4 kHz, IP-65 rating per IEC529, Coverage Pattern: 60° horizontal by 80° vertical , Maximum SPL (1m): 109dB peak, 8 ohm Impedence, Transformer Taps: 70V/100V: 20W, 100V: 30 w.MAKE:Bose/EV/Audac(HS121)/Sonodyne
409Supplying, installing, testing and commissioning of quad channel Power amplifier of continous power 4x 240 W @8 ohm and 100V, frequency response- 50Hz-20 kHz , class D amplifier.The amplifier should be clean reliable audio for public address amplification and music.Line input less than 1 volt, unbalanced& line output less than 1 volt unbalanced.Make-Bose/Audac(PMQ240)/EV/Sonodyne
410Supply of 30 W weather proof rock speaker with LMT, IP65 , Transformer Taps: 70V/100V: 20W, 100V: 30 w Make-Sonodyne (RS 650)/Bose/EV/Audac
411Supply of 10-Channel Mixing Console: Max. 4 Mic / 10 Line Inputs (2 mono + 1 stereo) / 4 GROUP Buses + 1 Stereo Bus / 4 AUX (incl. FX),16-Channel Mixing Console mic preamps with an inverted Darlington circuit,1-Knob compressors,High-grade effects: SPX with 24 programs,24-bit/192kHz 2in/2out USB Audio functions,Works with the iPad (2 or later) through the Apple iPad Camera Connection Kit / Lightning to USB Camera Adapter,Includes Cubase AI DAW software download version,PAD switch on mono inputs,+48V phantom power,XLR balanced outputs with provision for bluetooth.Make-Yamaha/Soundcraft/Studiomaster
412SITC of 17U 600/650D UL Listed Floor mount Rack with Front perforated door with 3 point lock, Rear mesh door with Cam lock and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray - Ventilation - 495W - 375D and H/W screw920sets). Make: Valrack/ Rittal/ Legrand
413Speaker Cable Armoured 2 core 2.5 sqmm PVC Sheathed etc complete as required.
414Laying of cable (Digging , laying and refilling with sand and Bricks)
415Installation of all equipment, testing and commissioning of the system
416CASSETTE TYPE SPLIT UNITS(IPC) :-Supply,installation, testing and commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU),Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50Hz, 1/3 phase AC supply. the system shall be capable of performing cooling, dehumidification, Air circulation, filtration & ventilation of following capacity with Scroll/ rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity asper relevant IS Code. The lab testing reports as per IS: 1391shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electro technical Commission (IEC) 17025 standards/ Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA) with Original Equipment Manufacturer (OEM) etc. complete as per IS: 1391 as required. 5 Star Inverter Type- Cooling only.4.0 TR with 5 Star BEE Rating (LG-ZTNQ48GMLH2/ O General-AUGG48CRAA-B/ Daikin-FCMF140ARV169)
417AIR CONDITIONER SPLIT :-Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . 1.5 TR with 5 Star BEE Rating (LG-AS-Q20JWZE/ O General-ASGG18CGWA-B/ Daikin-FTKU50XV16)
4182.0 TR with 5 Star BEE Rating (O General-ASGG24CGWA-B/ Daikin-FTKM60XV16 /Hitachi-YOSHI 5500STXL)
419REFRIGRANT PIPING:-Supply,installation of hard/soft ISI marked copper refrigerant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job.1 TR to 3 TR high wall split A.C
420Supply & Installation of interconnecting following sizes of refrigerant copper pipe work of following outer diameter, insulated with 25mm thick closed cell electrometric Nitrile rubber tubular insulation between each set of indoor & outdoor units . The pipe dia upto 25 shall be soft seamless & above 25mm dia shall be hard seamless . All piping inside the room shall be properly fixed/supported with suitable size of clamp/ M.S. hanger and all external piping shall run in GI. cable tray etc. as reqd. Make of insulation-K Flex/Armacell/Vidoflex/Eurobatex/Isoline Make of pipe-Rajco/Mandev/Maxflow (for 4 TR CASSETTE ac)9.5 mm with 0.8 mm thick
42115.9 mm with 1.00 mm thick
422FRAME WORK :-Supply,installation & fabrication of MS base frame for outdoor unit and other nesessary material to complete the job.1 TR to 3 TR high wall split A.C
423DRAIN PIPING :-Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job.25mm nom. Dia pipe
424Supply and fixing of 4kVA Voltage stabilizer (Make-V-Guard/Microtek
425Supply and fixing of 5kVA Voltage stabilizer (Make-V-Guard/Microtek
426FIRE SAFETY EQUIPEMENT :-Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/Supremex/ Ceasefire/Flameklog/Kalpex .4.5 kg capacity
427Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/Supremex/ Ceasefire/Flameklog/Kalpex .6 kg capacity
428SIGNAGES: SITC of flexyl Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 3 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with stud type mirror screw with lifespan of 5 years, visible upto 4-6 hrs in total darkness for floor indication, fire exit, hydrant, hose reel, fire extinguisher, MCP, fire alarm panel, in case of fire, lift, alarm valve signages Make-Bajaj/Prolite
429Supply, installation, testing and commissioning of double sided visible LED illuminated Exit Indication Sign(300 mmx 150 mm, letter height minimum 150 mm) complete with directional arrow legend, rechargeable maintenance-free battery backup capable of providing continuous illumination for not less than 90 minutes upon mains failure, automatic charger circuit, fire-retardant ABS housing, polycarbonate diffuser, minimum letter height 150 mm, suitable for 230V AC supply, wall/ceiling mounting arrangement, complete with all accessories, wiring connections, testing and commissioning as required. The equipment shall comply with applicable requirements of NFPA 101, NFPA 70 and UL 924 standards.The Exit Indication Sign shall be a self-contained, LED-illuminated unit with integrated rechargeable battery backup, directional arrow (left, right, or straight), and automatic changeover circuitry. The sign shall operate in maintained mode (continuously illuminated) or non-maintained mode as specified, and shall automatically switch to battery power upon mains failure. The pictogram shall comply with ISO 7010 (E001 / E002 green running-man symbol) as mandated by NBC 2016 and IBC 2021. Make-Bajaj/Prolite
430Supply, Transportation, erection, testing and commissioning of 3 Phase, 415V, 50Hz, water cooled multi cylinder diesel generator set with alternator of 58.5KVA ( Make -Kirloskar / Jakson/TMTL/Mahindra/Captiva/Sterling) out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB IV+ norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB IV+ norms etc as per following specifications mentioned below. Warrentee period must be 2 years ALTERNATOR:The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21.ENGINE: Diesel Engine start, developing suitable BHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give 58.5KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 12 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc.01. Exhaust pipe of required size and length with insulation or clading.02. Diesel tank suitable for 8 to 10 Hours running capacity.03. Residential Silencer.04. SMF Batteries with leads as per the Manufacturer standardsAMF PANEL: Cubical, Compartmentalized, AMF Panel Baord with all Power & Control Contractors, Switches, Meters and other accessories, Internal Wiring, connection, inter-connection etc. for Trouble Free smooth function for 58.5 KVA DG Set complete with Battery Charger & leads as required. BASE PLATE: Common Base Plate of required size for mounting of Engine Alternator Set fabricated from MS Channel and vibration damping arrangement with cushy foor mounting including paintng etc. as required. FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along with smoke exhaust system piping including base frame of structure & lightening protection system. , control cable of 15mtr 2.5sqmm 6core , civil foundation work. (The Manufacturing of DG set shall not in any case be more than six months old from the date of award of work)
431LIGHTENING PROTECTION SYSTEM--- Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB
432Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather andtemperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB
433Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB
434Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB
435Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
436Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/ABB
437Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/ Dehn/ ABB
438Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB
439Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
440Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB
441Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561.Make-OBO/Dehn/ABB
442Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
443Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561.Make-OBO/Dehn/ABB
444Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB
445Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB
446Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/ABB
447Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB
448Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing systemMake-OBO/Dehn/ABB
449Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
450ON GRID SOLAR SOLAR PV SYSTEM :-Supply Installation Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono PERC HALF CUT bifacial Crystalline silicon solar cells, net metering facility ,necessary protections, earthing, mounted on hot dip GI structure( solar panel bottom height from roof level shall not be less than 300mm, accordingly GI structure to be designed) of suitable strength with following components a complete as arequired: a) Solar Photovoltaic Module of capacity 545Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730-Part-1,IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 22%. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase , 4 wire, 50Hz +/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree Celcious. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage,frequency. c) Data Monitoring System complete with accessories.d)Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. asarequired.e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc. asrequired. with all required accessories as required as per the direction of Engg-in-charge.Make-Tata/waree/luminous/adani/panasonic. The entire SOLAR system should be Replacement Warranty will be 5 years
451P.H. WORKSupplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.(Supreme/Ashirvad/Oriplast) In Ground floor20mm dia C-PVC ASTM-D Pipes
45225mm dia C-PVC ASTM-D Pipes
45332mm dia UPVC ASTM-D Pipes
45440mm dia UPVC ASTM-D Pipes In FF
455Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mm thick wall In Ground floor
456Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.In Ground floor
457Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge.15mm dia CP two way bib cock (Plaza/ Aquatic/ Amber/ Cera/ Kerovit/ Hydro/ Somany)
45815mm dia CP S.B bib cock (Plaza/ Aquatic/ Amber/ Cera/ Kerovit/ Hydro/ Somany)
45915 mm dia CP L.B. Bib cock(CON-CHR-107KN)
46015mm dia CP angle stop cock(CON-CHR-053KN)
46120mm dia CP Con. stop cock (CON-CHR-089KN)
46215mm dia CP flange
46315mm Cp extention piece
46425mm dia C-PVC ball valve.(Ashrivad make)
46540mm dia C-PVC ball valve.(Ashrivad make)
466125mmdia C.P.grating
46715mm dia C.P hand shower
468600mm X 125mm C.P glass shelf (ACN -CHR-1171N)
469CP towel rail (25 mm)(ACN-CHR-1111N)
470C.P towel ring(ACN-CHR-1121NMI)
471CP Soap Holder (ACN-CHR-1131N)
47215mm dia C.P. Revolving Shower
47315mm dia C.P Pillar cock(CON-CHR-021KN)
47415 mm dia CP Sink Cock(CON-CHR-357KN)
475Corner shelf with Bracket (ACN-CHR-1173N)
476Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge.10 litres capacity pvc low level cistern (Slimline-white)
477Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 3.18m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge.2000litre capacity water storage tanks (First Floor)
478Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturers specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge.110mm dia U-PVC SWR pipes(Supreme/Ashirvad)
479110mm U-PVC door Tee
480110mm U-PVC plain Tee
481110mm U-PVC door bend
482110mm U-PVC plain bend
483110mm dia U-PVC off set
484110mm dia U-PVC 'P' trap
485110mm dia U-PVC cowl
486110mm dia U-PVC clamp
48775mm dia U-PVC SWR pipe(Supreeme/Ashirvad make)
48875mm U-PVC plain bend
489Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI/PVC SWR pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge.250mm to 375mm thick wall
490Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI P or S trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge580mm size Orissa pan (Parryware/Hind ware/ Cera/ Kerovit/ Somany)
491Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral P or S trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge.E.W.C. with S trap plain with seat cover(Parryware/Hind ware/Cera/Kerovit/Somany)
492Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps(Plaza make) capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge.550mmx400mm size wash hand basin Parryware/Hind ware/Cera/Kerovit/Somany)
493Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with cast iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge.600x450x250 mm stainless steel kitchen sink (Jayna make)
494Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge.600mmx450mm size B.E mirror
495Supplying all materials, labour, T&P and providing fitting and fixing Dr.Aqua guard Magna UV+HD of size 316x251x462mm with wall hanging facility having storage of 7 ltrs. etc.with internal water supply connection complete as per direction of the Engineer-in-charge.
496Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge.
497Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In ground floor
498Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor
499Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.12mm thick CP (1:4) on bw- In gf
500Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles etc. complete as per direction of the Engineer in charge. (Ceramic floor tiles of make of size 30cm x 30cm to be pre-approved by the Engineer in charge).Ground floor
501Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles etc.complete as per direction of the Engineer in charge. (Ceramic wall tiles of make size 45 x 30 special plain / printed series to be pre-approved by the Engineer in charge).In ground floor (inside/outside)
502Supplying all materials, labour, T&P and providing granite tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles etc. complete as per direction of the Engineer in charge. G/F
503Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter.
504Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge
505Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.Inside size 910mmx910mmx910mm Boys hostel + Girls Hostel
506Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:1.5:3) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, fly ash bricks in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI/P-trap gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm
507Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.Inside size 760mmx760mmx460mm
508R.C.P.C Cover(18\\" round man hole cover)
509Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.Inside size 910mmx910mmx910mm
510Extra for every additional depth of 0.30m or part thereof upto 4.50m depth
511R.C.P.C Cover(24\\" round man hole cover)
512Supplying all materials, labour, T&P and constructing soakway pit of the following size with precast RCC rings joined loose, gravel backing in the rear of well steining, precast RCC cover slab in cement concrete (1:1.5:3) using 12mm size hg chips fitted with iron lifting handles including cutting hole in the rings for inlet pipe,earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. RCC rings soakway pit 1.22m dia x 2.10m deep
513Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Brick masonry soakway pit 1.40m dia x 2.00m deep
514Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class 3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturers specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm dia u-pvc pipe alround concrete
515160mm dia u-pvc pipe alround concrete
516Construction of 50 users RCC septic tank- 1 No. :-Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge.
517Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general.
518Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge.
51950 users :-Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge.
520Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor
521Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor (inside/outside)
522Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor (inside/outside)
523Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.R.C.C floor and roof slabs up to 4.30m height
524R.C.C beams,columns,girder and bressmer etc.
525Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor
526Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor
527Construction 4 nos 30 users RCC Septic tank :-Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge.
528- do - with addl. Depth of 1.5 m
529Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department.
530Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge.In ground floor
531Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge.In ground floor
532Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.Base
533Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
534For RCC wall
535Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor
536Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
537Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
538Supplying all materials, labour, T&P and fitting and fixing S.W.Tee of size 150mx160mx150m as per P.H.D.specification and direction of the E.I.C.
539Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete.
540Supplying all materials, labour, T&P and fitting and fixing UPVC SWR soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge.110mm diameter U-PVC SWR pipe
541110mm dia U-PVC Plain shoe bend
542110mm dia U-PVC Cowl
543Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge.4x2 x(4.10+1.60) x 0.15 x 2.00
54450,000 Ltrs.Capacity UGR (SUMP) :-Earth work in All kinds of soil and gravels mixed with stone and boulder not exceeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department.UGR - 1x8.70x5.20x1.50
545-do- with Ist additional depth of 1.50 m over the initial lead and lift
546Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge.
547Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
548Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
549Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. @ 100 kg / cum =
550Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete.In ground floor.RCC floor roof, chajja etc
551RCC Beam, Column, wall etc
552RCC Plinth bend/ Raft Base slab 2(8.10+4.60)x0.80
553Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) over CC work including watering curring and conveyance of all materials to site.
554Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.Quantity same as item No-4
555Supplying and fitting and fixing stainless steel 34 grade in said rail using 5mm dia 2mm thick circular pipe and balustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below including welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge.
556Providing fitting and fixing 24\\" RCPC cover etc complete as per direction of Engineer-in-charge
557Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge.50mm dia brass or gun metal fullway valve(Shakti Make)
55850mm dia brass or gun metal horizontal check valve(Shakti Make)
559Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type (Horizontal)submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge.2 H.P three phase 7 stage head range 47 to 76 metres, discharge 170 to 67 L.P.M with outlet dia of 50mm.
560DOL Control panel
56140mm dia steel short piece
5624.50sqmm flat cable
56320mm dia rigid UPVC pipes
564Labour charges for lowering including transportation
565Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge40mm HDPE pipes
566Sinking of 200mmx150mm dia large Tube well(2 No.) :-Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation(G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore.Labour for Drilling of 200 mm dia bore 0mtr to 120mtr
567Labour for Drilling of 150 mm dia bore 0mtr to 120mtr
568Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.Lowering of 200 mm dia GI/P.V.C/MS casing pipes 0 mtr to 30 mtrs
569Lowering of 200mm dia GI/P.V.C/MS casing pipes 31 mtr to 45 mtrs
570Cost of 200 mm dia ASTM-D-1785/89 P.V.C schedule-80 pipe
571Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in chargeBy DTH
572Supplying all materials and labour,tools and plant and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5 mtrs below ground level(as per drawing)to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock the bottom to ensure sanitary sealing(excluding cost of cement which willbe supplied by the Department).Submerssible Pump Set 1 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 6110 L.M.P with outlet dia of 32 mm.
573DOL control panel
5742.50 sqmm cable
57532mm dia steel short piece
57632 mm dia HDPE Pipe
577Bore Cap
578C.I.Bracket
579Rope Wire
580Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site.
581Supply all materials,labours,T&P and construction bore well protection chamber of the inside size 650x650x1000 height with cement concrete ( 1;3;6) using 40 mm size hard granite metal on foundation,1st class fly ash brickwork incement motar(1:3),with base cement concrete (1:2:4) useing 12 mm size h.g chips ,12 mm thick cement plaster (1:4) inside and out site ,R CC cover slab in (1:1.5:3) using 12 mm size h.g chips earthwork in excavation in all kinds of soil and refiling the cavity around the chamber including watering ,curing,convayance of all materials to worksite,payment of royalty,taxes etc all complete as per approved specification and direction of the engineer-in -charge. Bore well protection chamber. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58628516
AUTHORITY Government Departments
TENDER VALUE 28.38 Crore
LAST DATE 02-12-2026
Authority
Authority Name Civil Division
Work Description Tender for Development Of Baba Dhableswar Temple, Kataka.
Basic Detail
Tender No CE- Bldg-I-36/2026-27
Bidding Type Tender
Location
City Cuttack
State Odisha
Key Dates
Publish Date 20 Nov 2026
Submission Date 02 Dec 2026
Open Date 03 Dec 2026
Finance
Tender Value 28.38 Crore
Tender Fee 10000
EMD 28.39 Lakhs
Exemption Available
Document List
b975ddc4-7f87-4ce5-aeb4-8c67ddb04836.html
BOQ_622487.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Dec 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

b975ddc4-7f87-4ce5-aeb4-8c67ddb04836.html

xls

BOQ_622487.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender