Tender For Safety Related Electrical Works Of Tiringpahar Iron Ore Mines In The District Of Keonjhar
Tender Value
15.58 Lakhs
Estimated cost
Bid Submission
30 Nov 2026
9 days left
EMD
16000
Bank guarantee accepted
Document Fee
7080
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kendujhar → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Safety Related Electrical Works Of Tiringpahar Iron Ore Mines In The District Of Keonjhar
BOQ
| Sl. No. | Item Description |
| 1 | Electrical Works |
| 2 | Supply, installation, testing, and commissioning of Type 1+2, 3P+N, 50 kA Surge Protection Devices (SPD) of L&T, Cat. No. AUSP123PN50D or equivalent, at different existing LT feeders, including all required accessories, complete wiring, and labour charges, as per the direction of the EIC. |
| 3 | Supply, installation, testing, and commissioning of Type 1+2, 1P+N, 50 kA Surge Protection Devices (SPD) of L&T, Cat. No. AUSP121PN50D or equivalent, at different existing LT feeders, including all required accessories, complete wiring, and labour charges, as per the direction of the EIC. |
| 4 | Supply, installation & commissioning of Anti-Climbing Device made of GI barbed wire, clamping arrangement etc. (2 Kg per support) including all accessories, labour cost, T&P etc. complete work as per direction of EIC. |
| 5 | Supply, installation, testing, and commissioning of 6 kVA, 1-Phase Online UPS complete with 2x12V, 150Ah VRLA battery bank, including 150 Mtr 2.5 Sq.mm Single Copper Cable, mounting arrangement, including all required accessories, complete wiring, and labour charges, as per the direction of the EIC. |
| 6 | Supply, laying, testing, and commissioning of 70 Sq.mm, 3.5 Core, Aluminium Armoured LT Cable for LMS containers, including cable laying, dressing, termination, gland, lugs, clamps, saddles, including all required accessories, complete wiring, and labour charges, as per the direction of the EIC. |
| 7 | Supply and laying of 120 mm Dia HDPE Pipe, PN6, PE80 Grade including all accessories, labour cost, T&P etc. complete work as per Direction of EIC. |
| 8 | Supply, installation, testing and commissioning of 35 Sq.mm Copper Down Conductor for the existing Copper Strike Lightning Arrester System, including proper connection to the earth pits, including all required accessories, complete wiring, and labour charges, as per the direction of the EIC. |
| 9 | Supply and fixing of 11 kV Polymer Pin Insulator complete with hot dip galvanized steel pin, nuts, bolts, washers and all necessary accessories including labour charges for erection, tightening and commissioning, including all required accessories, complete wiring, and labour charges, as per the direction of the EIC. |
| 10 | Supply, installation and commissioning of 11 kV Polymer type Disc Insulator (T&C) (70 KN) with Hardware fitting (T&C), 70 KN, 3 Bolt including all required accessories, complete wiring, and labour charges, as per the direction of the EIC. |
| 11 | Supply, installation and commissioning of 12 kV, 10 kA Station Class Lightning Arrester (Polymer Type) including all required accessories, complete wiring, and labour charges, as per the direction of the EIC. |
| 12 | Supply, installation & commissioning of 11 kV, 3-pole, 400 Amp Horn Gap type Fuse with Polymer type Post Insulator and other accessories including all accessories, labour cost, T&P etc. complete work as per Direction of EiC. |
| 13 | Supply, installation, testing and commissioning of floor-mounted, front-operated, front-access, extensible type cubicle, double-door, outdoor type, IP-65 rated panel, totally enclosed CRCA sheet steel, fabricated from 2 mm thick sheet, complete with powder coating finish, proper earthing/bonding, double compression cable glands, and painting, suitable as per the following specifications including all required accessories, complete wiring, and labour charges, as per the direction of the EIC:MAIN PANEL:63 Amp MCCB, 4 Pole, C-Curve (L&T BB40630C) – 1 No.32 Amp MCB, 2 Pole, C-Curve (L&T AU10S20323C) – 2 Nos.32 Amp MCB, 4 Pole, C-Curve (L&T AU10S40323C) – 2 Nos.Earth Leakage Relay (240–415 V AC/DC) with 1 C/O Pre-Alarm + 1 C/O Fault Contact – 1 No.CBCT (Circular Type), 38 mm ID – 1 No.Shunt Release DZ1, 415 V AC – 1 No.Auxiliary Contactor DN0/DN1, 2 C/O, Right Side Mounting (L&T CM978870000) – 1 No.R-Y-B LED Indicating Lamps, 220/240 V AC (L&T) – 3 Nos.6 Amp SP MCB, 10 kA, B-Curve (L&T) – 1 No.50 kA, Type-1+2, 3P+N SPD (L&T AUSP123PN50) – 1 No.4 Pole Aluminium Busbar with colour coding – 3 Kg.The panel shall include proper internal wiring, ferruling, gland plates, busbar supports, terminal blocks, danger notice plate, name plate, and identification/marking of all equipment along with a proper Single Line Diagram. |
| 14 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/coke and salt including all required accessories, complete wiring, and labour charges, as per the direction of the EIC. |
| 15 | Supply, Installation, Testing and Commissioning (SITC) of Double Pole (DP) RCCB 25A rating, suitable for 230V AC single phase system, with minimum 30mA sensitivity and minimum 15kA breaking capacity, conforming to relevant IS/IEC standards, complete with DIN rail mounting, internal wiring, ferruling, termination, testing and commissioning including all required accessories, complete wiring, and labour charges, as per the direction of the EIC. |
| 16 | Supply, Installation, Testing and Commissioning (SITC) of Double Pole (DP) RCCB 40A rating, suitable for 230V AC single phase system, with minimum 30mA sensitivity and minimum 10kA breaking capacity, conforming to relevant IS/IEC standards, complete with DIN rail mounting, internal wiring, ferruling, termination, testing and commissioning including all required accessories, complete wiring, and labour charges, as per the direction of the EIC. |
| 17 | Supply & fixing of outdoor type GI Junction Box (18\\"x15\\"x15\\") with 1.5 Mtrs stand door, 4 way terminal block with including all required accessories, complete wiring, and labour charges, as per the direction of the EIC. |
| 18 | Onsite transformer oil filtration of existing 1000 kVA, 33/0.440 kV transformer using suitable high vacuum transformer oil filtration machine including heating, dehydration, degassing and filtration of transformer oil, complete with pre and post BDV testing, connection/disconnection of hose pipes, operation of filtration equipment, and restoration of transformer to normal condition after completion of work. The work also includes to & fro transportation of filtration machine, hose pipes, BDV kit, tools, including all required accessories, complete wiring, and labour charges, as per the direction of the EIC. |
| 19 | Supply, installation and commissioning of 440 V Danger Board in accordance with Rule No. 20 of CEA Regulation-2023, the minimum size of plate 250 x 200 mm, made up of mild steel sheet of 1.6 mm thick and vitreous enamelled white, with letters, figures and the conventional skull & cross-bones in signal red colour on the front side (the rear side of the plate shall also be enamelled in white colour). The language of the danger board should be Odia, English & Hindi and the size of letters and spacing between them shall be so chosen that these are uniformly written. The corners of the plates shall be rounded off and the location of fixing holes shall be such that it shall be bolted through pole clamp. For each support including all required accessories, complete wiring, and labour charges, as per the direction of the EIC. |
| 20 | Supply and fixing of Shock Treatment Chart (in Odia, Hindi & English) with OMC logo, duly laminated, to be installed in the electrical control panel room, including all required accessories, complete wiring, and labour charges, as per the direction of the EIC. |
| 21 | Supply and fixing of cable marker tie tags conforming to the standards of the Electrical Inspectorate, including all required accessories, complete wiring, and labour charges, as per the direction of the EIC. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysDec 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender