Tender For Reinforcement Work Of Kantakula - Ii & Kantakula - Iii Rl Projects Under Hindol Block In Dhenkanal District (Pkg. No. 38)
Tender Value
17.51 Lakhs
Estimated cost
Bid Submission
30 Nov 2026
8 days left
EMD
17513
Bank guarantee accepted
Document Fee
7080
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dhenkanal → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Reinforcement Work Of Kantakula - Ii & Kantakula - Iii Rl Projects Under Hindol Block In Dhenkanal District (Pkg. No. 38)
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation in foundation in hard soil with 50 mtr initial lead 1.5 m initial lift including rough dressing and breaking clods to 2 cm to 7 cm and laying in layers not exceeding 0.3 m in depth as per direction of Engineer-in-charge |
| 2 | Filling foundation and plinth with sand watered and rammed as per direction of Engineer-in-charge. |
| 3 | Cement concrete (1:4:8) with 4 cm size h.g metal as per direction of engineer-in-charge. |
| 4 | Cement concrete (1:2:4) with 12 cm size h.g Chips as per direction of engineer-in-charge. |
| 5 | Brick work with K.B Brick (25cmx12cm x8 cm) having crushing strength not less than 35kg/cm with dimensional tolerance ± 5% in cement mortar (1:6) in foundation and plinth. |
| 6 | 12mm thick cement plaster (1:6 ) over brick masonary |
| 7 | Cement Concrete (1:2:4) with 12 mm size HG chips for R.C.C Works. |
| 8 | Supplying, fitting and placing oncoated HYSD (TISCON) bar reinforcement complete as per drawing and technical specification including cutting, binding, bending and cost of binding wire. |
| 9 | Rigid and smooth centering and shuttering for RCC work including false work and dismentalling them after casting including cost of materials complete. |
| 10 | Roof Slab & Chajja |
| 11 | Filling F & P with excavated materials, moorum including watering and ramming as directed by the engineer-in-charge |
| 12 | Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge. |
| 13 | Supplying of unplasticised rigid UPVC pipe ivory gray in colour having specific gravity of 1.40 to 1.46 gms.cc, of straight length of 6 (six) meter for portable water suppliers conforming to IS-4985/2000 of BIS- Amendment 2 read with Table =1 of IS specification bearing ISI marks for working pressure CI -IUO=PVC pipe to withstand pressure of 2.50 Kgf/sqcm , 4.0 Kgf/sqcm , 6.0 Kgf/sqcm , 8.0 Kgf/sqcm and the specification and manufacturer name should be prominenity marked on body of each pipe as per the latest Amendment of IS 4985.it includes the cost of sockets in case of plain ended pipe PDI test are to be conducted and should be marked on body of each pipe and report is to be obtained from CIPT, Bhubaneswar/ EPM, Orissa, Bhubaneswar necessary approval of authority including transporotation and laying at site all complete with cost of solvent cement. |
| 14 | 160 mm dia (Class-I) |
| 15 | 200 mm dia (Class-I) |
| 16 | Labour charge for laying and fitting 160mm PVC pipe |
| 17 | Labour charge for laying and fitting 200mm PVC pipe |
| 18 | 10 HP Monoblock centrifugal pump set at total of 16mtr capable to discharge 1700 LPM squirrel cage induction motor fitted with companion flanges and class -F insulation suitable for operation 415 volt+6%-15%, 3phase, 50Hz AC power supply and full load current 15.6 amp with size of suction and delivery 100mmx100mm dia with overall efficiency 60 -65. The materials of construction as given below.a) Casing :F.C. 200 as per IS 210/1978 b) Impeller : Bronze grade LTB-2 of IS c) Shaft : High carbon steel grade 40c8 of IS 1570(Part-2)318/1981 d) GAsket : As per IS 5120/1977 and the pump sets must be as per IS-9079/2002 of reputed brand having wide dealership net work for easy availability of spares. |
| 19 | Supplying fitting fixing control pannel starter, BCH make with arrangement of volt meter, Amp, Meter mfitted with MCB control switch complete including indicator lamp with irrigation pannel bozard of apaproved design made out of 16gauge CR sheedt basement MS angle with double lock powder coat painting over one coat primere including fixing danager board with lucking devices and fixing of suitable stand for control pannel unit. |
| 20 | Motor hood cover of 18 gauge C.R. sheet with double coat painting over one coat primer so as to cover the motor |
| 21 | MS base plate for fitting of pannel and pump as per sample as per direction of Engineer-in-charge. |
| 22 | 3 x 16 sqm Tarpodar Cable XLPE (Cross like polythylin) confirming to IS-7098 (Part-II) including laying below 9 mtr of the ground & fitting the excavated materials including watering & ramming. |
| 23 | 63/100 AMP 415 volt T.P. main switch confirming to IS 4064 (Pt-I & Pt-II) with utilisation category Ac-22. |
| 24 | Supply, fittintg and placing of 100mmdia Nominal Bore GI pipes having wall thickness 4.5 mm electrical resistance welded of medimum class confirming to IS-1239 (part-I/2004) with latest amendments, screwed at both ends as per IS-554 socketed at 1 end and other end protected with plastic threaded protector. The socket confirming IS-1239 (Part-II/1992) with latest amendments in rendom length of 4 to 7 mtrs. Each pipe should bear ISI certification and manufacturers name /trade mark. |
| 25 | Labour charges for fitting, fixing of suction, delivery fitting including M.S. Tee set, NR valve, Switch valve and Air release valve etc minor welding transportation of materials to site etc. including nut, bolt rubber insallation etc complete. |
| 26 | Fabrication of special joint including cutting and welding of pipes out of M.S Pipe / G.I Pipe including welding of flange at one end and other end suitable for for connection to delivery pipe lines of pump sets including cost of cutting and welding , materials and fitting it in proper alignment with the delivery pipe line of pump set etc. complete. |
| 27 | 100mm dia C.I. Screw base foot valve (Kirloskar make ) IS |
| 28 | 100mm dia G.I. bend IS No 1239 (Part-II/1992) |
| 29 | 100mm dia G.I. flange IS No 6392/1971 |
| 30 | 100mm dia G.I. Socket IS No 6392/1972 |
| 31 | 100 mm dia C.I. N.R valve IS No 5312 (Part-I) with ISI mark |
| 32 | 100x100x100mm dia G.I. Tee with Plug for Priming set |
| 33 | 200mm dia PVC end cap confirming to I\PL-R PVC-IS 2000 F |
| 34 | 160mm dia PVC end cap confirming to I\PL-R PVC-IS 2000 F |
| 35 | 110 mm dia PVC FTA. |
| 36 | Cost of Nut Bolt. |
| 37 | Cost of Rubber Insertion. |
| 38 | 160x160x110mm MS Tee set with bend,closing and opening arrangement |
| 39 | 50mm dia C.I. Air Release Valve IS Mark 14845(SI)with 1 mtr long G.I.Short piece with saddle |
| 40 | 200x200x160mm PVC Tee (6 Kgf/sqcm) confirming to PL-R PVC-IS 2000F |
| 41 | 200x110mm dia PVC Reducing Socket. |
| 42 | 160x160x160mm PVC equal Tee (6 Kgf/sqcm) confirming to PL-R PVC-IS 2000F |
| 43 | Earth work excavation in foundation in hard soil with 50 mtr initial lead 1.5 m initial lift including rough dressing and breaking clods to 2 cm to 7 cm and laying in layers not exceeding 0.3 m in depth as per direction of Engineer-in-charge |
| 44 | Filling foundation and plinth with sand watered and rammed as per direction of Engineer-in-charge. |
| 45 | Cement concrete (1:4:8) with 4 cm size h.g metal as per direction of engineer-in-charge. |
| 46 | Cement concrete (1:2:4) with 12 cm size h.g Chips as per direction of engineer-in-charge. |
| 47 | Brick work with K.B Brick (25cmx12cm x8 cm) having crushing strength not less than 35kg/cm with dimensional tolerance ± 5% in cement mortar (1:6) in foundation and plinth. |
| 48 | 12mm thick cement plaster (1:6 ) over brick masonary |
| 49 | Cement Concrete (1:2:4) with 12 mm size HG chips for R.C.C Works. |
| 50 | Supplying, fitting and placing oncoated HYSD (TISCON) bar reinforcement complete as per drawing and technical specification including cutting, binding, bending and cost of binding wire. |
| 51 | Rigid and smooth centering and shuttering for RCC work including false work and dismentalling them after casting including cost of materials complete. |
| 52 | Roof Slab & Chajja |
| 53 | Filling F & P with excavated materials, moorum including watering and ramming as directed by the engineer-in-charge |
| 54 | Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge. |
| 55 | Supplying of unplasticised rigid UPVC pipe ivory gray in colour having specific gravity of 1.40 to 1.46 gms.cc, of straight length of 6 (six) meter for portable water suppliers conforming to IS-4985/2000 of BIS- Amendment 2 read with Table =1 of IS specification bearing ISI marks for working pressure CI -IUO=PVC pipe to withstand pressure of 2.50 Kgf/sqcm , 4.0 Kgf/sqcm , 6.0 Kgf/sqcm , 8.0 Kgf/sqcm and the specification and manufacturer name should be prominenity marked on body of each pipe as per the latest Amendment of IS 4985.it includes the cost of sockets in case of plain ended pipe PDI test are to be conducted and should be marked on body of each pipe and report is to be obtained from CIPT, Bhubaneswar/ EPM, Orissa, Bhubaneswar necessary approval of authority including transporotation and laying at site all complete with cost of solvent cement. |
| 56 | 160 mm dia (Class-I) |
| 57 | 200 mm dia (Class-I) |
| 58 | Labour charge for laying and fitting 160mm PVC pipe |
| 59 | Labour charge for laying and fitting 200mm PVC pipe |
| 60 | 10 HP Monoblock centrifugal pump set at total of 16mtr capable to discharge 1700 LPM squirrel cage induction motor fitted with companion flanges and class -F insulation suitable for operation 415 volt+6%-15%, 3phase, 50Hz AC power supply and full load current 15.6 amp with size of suction and delivery 100mmx100mm dia with overall efficiency 60 -65. The materials of construction as given below.a) Casing :F.C. 200 as per IS 210/1978 b) Impeller : Bronze grade LTB-2 of IS c) Shaft : High carbon steel grade 40c8 of IS 1570(Part-2)318/1981 d) GAsket : As per IS 5120/1977 and the pump sets must be as per IS-9079/2002 of reputed brand having wide dealership net work for easy availability of spares. |
| 61 | Supplying fitting fixing control pannel starter, BCH make with arrangement of volt meter, Amp, Meter mfitted with MCB control switch complete including indicator lamp with irrigation pannel bozard of apaproved design made out of 16gauge CR sheedt basement MS angle with double lock powder coat painting over one coat primere including fixing danager board with lucking devices and fixing of suitable stand for control pannel unit. |
| 62 | Motor hood cover of 18 gauge C.R. sheet with double coat painting over one coat primer so as to cover the motor |
| 63 | MS base plate for fitting of pannel and pump as per sample as per direction of Engineer-in-charge. |
| 64 | 3 x 16 sqm Tarpodar Cable XLPE (Cross like polythylin) confirming to IS-7098 (Part-II) including laying below 9 mtr of the ground & fitting the excavated materials including watering & ramming. |
| 65 | 63/100 AMP 415 volt T.P. main switch confirming to IS 4064 (Pt-I & Pt-II) with utilisation category Ac-22. |
| 66 | Supply, fittintg and placing of 100mmdia Nominal Bore GI pipes having wall thickness 4.5 mm electrical resistance welded of medimum class confirming to IS-1239 (part-I/2004) with latest amendments, screwed at both ends as per IS-554 socketed at 1 end and other end protected with plastic threaded protector. The socket confirming IS-1239 (Part-II/1992) with latest amendments in rendom length of 4 to 7 mtrs. Each pipe should bear ISI certification and manufacturers name /trade mark. |
| 67 | Labour charges for fitting, fixing of suction, delivery fitting including M.S. Tee set, NR valve, Switch valve and Air release valve etc minor welding transportation of materials to site etc. including nut, bolt rubber insallation etc complete. |
| 68 | Fabrication of special joint including cutting and welding of pipes out of M.S Pipe / G.I Pipe including welding of flange at one end and other end suitable for for connection to delivery pipe lines of pump sets including cost of cutting and welding , materials and fitting it in proper alignment with the delivery pipe line of pump set etc. complete. |
| 69 | 100mm dia C.I. Screw base foot valve (Kirloskar make ) IS |
| 70 | 100mm dia G.I. bend IS No 1239 (Part-II/1992) |
| 71 | 100mm dia G.I. flange IS No 6392/1971 |
| 72 | 100mm dia G.I. Socket IS No 6392/1972 |
| 73 | 100 mm dia C.I. N.R valve IS No 5312 (Part-I) with ISI mark |
| 74 | 100x100x100mm dia G.I. Tee with Plug for Priming set |
| 75 | 200mm dia PVC end cap confirming to I\PL-R PVC-IS 2000 F |
| 76 | 160mm dia PVC end cap confirming to I\PL-R PVC-IS 2000 F |
| 77 | 110 mm dia PVC FTA. |
| 78 | Cost of Nut Bolt. |
| 79 | Cost of Rubber Insertion. |
| 80 | 160x160x110mm MS Tee set with bend,closing and opening arrangement |
| 81 | 50mm dia C.I. Air Release Valve IS Mark 14845(SI)with 1 mtr long G.I.Short piece with saddle |
| 82 | 200x200x160mm PVC Tee (6 Kgf/sqcm) confirming to PL-R PVC-IS 2000F |
| 83 | 200x110mm dia PVC Reducing Socket. |
| 84 | 160x160x160mm PVC equal Tee (6 Kgf/sqcm) confirming to PL-R PVC-IS 2000F |
| 85 | Electrical Earthing with 40mtr dia medium duty GI earthing pipe each 3 m longwith installation including cost of all materials like GI flange chorcoat, salf etc. as required as per I.E Rule |
| 86 | Other Electrical materials such as pvc tape.7/20pvc copper wire 3/20 pvc copper wire G.I flxible condite pipe no 6 GI wire copper cable socket GI socket and petty materials required for electrical installation. All materials should be as per IS including fitting charges and electrical installation & energisation. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysDec 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer