Tender For Providing Electrical Installation For 800 Kva Ht Connection At Kovilvazhi Corporation Land In Ward No 60.Estimate Amount : Rs.93.50 Lakhs
Tender Value
93.50 Lakhs
Estimated cost
Bid Submission
07 Dec 2026
16 days left
EMD
1.87 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Tiruppur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Electrical Installation For 800 Kva Ht Connection At Kovilvazhi Corporation Land In Ward No 60.Estimate Amount : Rs.93.50 Lakhs
BOQ
| Sl. No. | Item Description |
| 1 | PART- A : POINT OF SUPPLY |
| 2 | 11KV SINGLE VCB PANEL(OUTDOOR)Erection, Testing and Commissioning of outdoor type 11KV 800A 25KA Single panel VCB with necessary fixing accessories, protective devices and metering with PT & CT and as per the technical specification as per TANGEDCO requirements. |
| 3 | Supply and laying of 3C x 300 Sqmm 11KV grade XLPE HT cable |
| 4 | Supply & End Termination of Indoor type heat shrinkable termination kit suitable for 11 KV 3 Core 185 Sq.mm XLPE cable complete with all materials, tarpaulin covering for armoured aluminium cable jointing etc., - Raychem make. |
| 5 | Supply & End Termination of Outdoor type heat shrinkable termination kit suitable for 11 KV 3 Core 185 Sq.mm XLPE cable complete with all materials, tarpaulin covering for armoured aluminium cable jointing etc., - Raychem make |
| 6 | PART – B : TRANSFORMER |
| 7 | Erection, Testing and commissioning of 11KV / 433 800KVA outdoor type transformer complete with first fill of Oil automatic OLTC control gear, RTCC panel with local and remote control panel, all components and accessories as per technical specification TECHNICAL SPECIFICATION OF POWER TRANSFORMER:Rating : 800 KVA, Service : Outdoor.Rated Frequency : 50 Hz No. of Phases : 3,Rated Voltage : 433 Volts, HV Winding : 11 KV, LV Winding : 433 Volts, Winding connection, HV Winding : Delta LV Winding (Neutral brought Out separately for earthing) : Star. HV side : Bushing, LV side : Cable Box, Vector group : Dyn 11. Type of cooling : ONAN, Type : On load. Range : + 10% to – 15% Steps : In steps of 2%. Winding Conductor material : Copper,(including labour amount) |
| 8 | Supply & Erection of Neutral CT box made out off 16Gauge CR Sheet with powder coating paint using 1 No 300/5A, CL: 5P10 Accuracy Tape Insulated CT with necessary hardware's etc.(including labour amount) |
| 9 | Supply & Erection of Neutral arrangement with DMC Support for 800KVA Transformer(including labour amount) |
| 10 | Supply and Erection of HT Meter Box with all accessories including connecting Cables (including labour amount) |
| 11 | PART - C : ELECTRICAL PANELS |
| 12 | M.V. PANEL -1 :A. BUS BAR : Double bus bar arrangement.i. MAIN BUS BAR :Aluminum bus bar rated for 1250 ABUS BAR SIZE :1Runs x 100mm x 12mm Al. flat/Phase .1Runs x 100mm x 6mm Al. flat / neutral.INCOMING : FOR EB SUPPLY.1 No. Air circuit breaker Manually Operated draw out type 4P, 433V 1250A 4P ACB 35 MVA for 1 Second each filled with the following meant for EB supply.a. 1 No. – Manual trip push button.b. 1 No. - Mechanical ON/OFF indicator.c. 1 No. – UV Coil device suitable for 415V ACd. 1 Set – 8 NO / 8NC Aux. Contacts.e. 5 Nos. – LED type indicating lamps for RYB Indication and ACB ON/OFF indication 230V AC. 1 No LED lamp with reset Button for UVf. 1 Set. of CT’s suitable for metering.g. 1 Set. of CT’s suitable for protectionh. 1 No. Earth fault relay .CDG11i. 1 No. Flush type digital 96sq mm size Multiparameter meter with RS 485 port for computer interfacing.( EM6400 or equivalent )j. 1 No. VCF D2 Relay for over voltage and under voltage cut off.k. 1 No. Maximum demand controller.l. Lot – Sufficient control MCB's for the system.m. 1 No. Mechanical inter lock arrangementEarthing : 25mm x 3mm Al. FlatGEN INCOMING :1800A 4P FSU with fuse links - 1 NoOUTGOINGS :630A 4P FSU with fuse links inter connected to main Busbar with suitable size of AL flat. - 4 Nos400A 4P FSU with fuse links inter connected to main Busbar with suitable size of AL flat. - 2 Nos250A 4P FSU with fuse links inter connected to main Busbar with suitable size of AL flat. - 2 NosAll outgoing feeders will be provided with 1 No. Flush type digital 96sq mm size Multiparameter (V/A/Hz/KW/KWH/PF) meter with RS 485 port for computer interfacing ( EM6400 or equivalent ). except capacitor feeders – necessary CT’s and control MCB's etc - (No. of feeders–8Nos)Capacitors Feeder will be provided with 1 No. Digital 96 Sqmm Ammeter with inbuilt Selector Switch necessary CT’s and control MCB's etc.,. - ( No. of feeders – 2 Nos )Paint: Powder coating process.Earthing : 25mm x 6mm Al. Flat(including labour amount) |
| 13 | LIGHTING SWITCH BOARD :INCOMING : 1250 A TPN FSU with fuse links - 1 No.OUTGOING :63A TPN FSU/MCB with fuse links and inter connected to main bus bar system with suitable size of Cu..flat - 6 Nos.25mm x 3mm Al. flat 1 Run/ Neutral.EARTHING : 25mm x 3mm Cu.flatPaint: Powder Coating Process.(including labour amount) |
| 14 | MCB DB - 1INCOMING :125A 4P ELMCCB + MCCB - 1 No.OUTGOING :32A TP MCB - 12 Nos.Paint: Powder Coating Process. (including labour amount) |
| 15 | LIGHTING SUB SWITCH BOARD - 1INCOMING :63A TPN MCB - 1 No.OUTGOING :32A DP MCB - 6 Nos.DB 4 way - 1 No (including labour amount) |
| 16 | LIGHTING DISTRIBUTION BOARD - 1INCOMING :32A DP RCBO (30mA) - 1 No.OUTGOING :6A SP MCB - 8 Nos.DPN DB 12 way - 1 No. (including labour amount) |
| 17 | APFC BOARD - ( 100 KVAR )INCOMER400A, TP+N, MCCB With Rotary Handle Mechanism - 1 No.63A TP MCB - 8 Nos.2 KVAR CAPACITOR FEEDER - 1 NoEach 2 KVAR Capacitor feeder will have 1 No 2 KVAR Capacitor duty contactor, 2 Nos push button for ON/OFF, 1 No LED indication lamp for ON and 1 No 2 KVAR Capacitor with Necessary Power/Control wire, wiring accessories and its hardware's etc.3 KVAR CAPACITOR FEEDER - 1 No.Each 3 KVAR Capacitor feeder will have 1 No 3 KVAR Capacitor duty contactor, 2 Nos push button for ON/OFF, 1 No LED indication lamp for ON and 1 No 3 KVAR Capacitor with Necessary Power/Control wire, wiring accessories and its hardware's etc.5 KVAR CAPACITOR FEEDER -1 No.Each 5 KVAR ELECTROLYTIC POWER Capacitor feeder will have 1 No 5 KVAR Capacitor duty contactor, 2 Nos push button for ON/OFF, 1 No LED indication lamp for ON and 1 No 5 KVAR Capacitor with Necessary Power/Control wire, wiring accessories and its hardware's etc.10 KVAR CAPACITOR FEEDER - 1 Nos.Each 10 KVAR ELECTROLYTIC POWER Capacitor feeder will have 1 No 10 KVAR Capacitor duty contactor, 2 Nos push button for ON/OFF, 1 No LED indication lamp for ON and 1 No 10 KVAR Capacitor with Necessary Power/Control wire, wiring accessories and its hardware's etc.15 KVAR CAPACITOR FEEDER - 2 Nos.Each 15 KVAR ELECTROLYTIC POWER Capacitor feeder will have 1 No 15 KVAR Capacitor duty contactor, 2 Nos push button for ON/OFF, 1 No LED indication lamp for ON and 1 No 15 KVAR Capacitor with Necessary Power/Control wire, wiringaccessories and its hardware's etc. 25 KVAR CAPACITOR FEEDER - 2 No.Each 25 KVAR ELECTROLYTIC POWER Capacitor feeder will have 1 No 25 KVAR Capacitor duty contactor, 2 Nos push button for ON/OFF, 1 No LED indication lamp for ON and 1 No 25KVAR Capacitor with Necessary Power/Control wire, wiring accessories and its hardware's etc.METERINGIncoming metering:-Incoming metering will have 1 No digital type 96sq.mm 1No Ammeter with in built selector switch, 1 No 6 Stage APFC Relay ,1No Auto/Manual Selector switch , .RYB indication lamps necessary CT’s and control MCB's etc,. - 1 SetBUS BAR SIZE :50mm x 6mm Cu . flat 1 Run /Phase .EARTHING : 25mm x 3mm Cu. FlatPaint: Powder coating process, (including labour amount) |
| 18 | Supply and Erection of 250 KVAR ELECTROLYTIC POWER Capacitor Bank (10x 25 KVAR ) with all accessories (including labour amount) |
| 19 | PART – D : EARTHING COPPER : Supply & Laying of copper the following sizes of earth wires, Rate shall be inclusive of 25 ´ 3mm GI spacer clamp for main earth flat, suitable clamping with MS flats for earth wires, etc., including terminal crimping type sockets, bolt nuts and washers etc., required to complete the work. |
| 20 | 25 x 1.5 / 3mm Copper Flat(including labour amount) |
| 21 | 8 Gauge Cu. Wire (including labour amount) |
| 22 | 10 Gauge Cu. Wire (including labour amount) |
| 23 | 40 x 6mm Copper Flat (including labour amount) |
| 24 | 1.5/2.5/4 SQMM Earth wire (including labour amount) |
| 25 | Supply & Erection of earth electrode using 2 Mtr.length 100mm CI Pipe generally as recommended by IS code using charcoal and clay as required excluding excavation and mationary work. (including labour amount) |
| 26 | Supply & Erection of 25 x 3 mm Cu. Earth Clamp. (including labour amount) |
| 27 | Bus Duct with Canopy and Flex Joint (including labour amount) |
| 28 | PART – E : L.T. CABLES : Supply and Laying of 1.1 KV grade PVC insulated XLPE sheathed armoured Al. Conductor cables confirming to IS: 7098 Part I 1988 of following sizes as per technical specification. |
| 29 | 3 ½ C x 400 Sqmm Al. Ar. XLPE Cable. |
| 30 | 3 ½ C x 185 Sqmm Al. Ar. XLPE Cable. |
| 31 | 3 1/2 C x 50 Sqmm Al. Ar. XLPE Cable. |
| 32 | 4 C x 16 Sqmm Al. Ar. XLPE cable. |
| 33 | 2/3/4 C x 4 Sqmm Cu. Ar.XLPE cable. (including labour amount) |
| 34 | 2/3/4 C x 2.5 Sqmm Cu. Ar. XLPE Cable. |
| 35 | 2/3/4 C x 1.5 Sqmm Cu. Ar. XLPECable. |
| 36 | 19C x 1.5 Sqmm Cu. Ar. Cable. |
| 37 | PART – F : CABLE TERMINATION MATERIALSTermination of the following cables by using of siemens type & Flange type glands, crimping sockets and glands earthing including copper – foil with all accessories required to complete the work. |
| 38 | 3 ½ C x 300/400 Sqmm Al. Ar. XLPE Cable. |
| 39 | 3 ½ C x 185 Sqmm Al. Ar. XLPE Cable. |
| 40 | 3 1/2 C x 50 Sqmm Al. Ar. XLPE Cable. |
| 41 | 2/3/3.5/4 C x 6/10/16 Sqmm Al. Ar. XLPE cable.(including labour amount) |
| 42 | 2/3/3.5/4C x 4 Sqmm Cu. Ar. XLPE Cable.(including labour amount) |
| 43 | 2/3/3.5/4 C x 2.5 Sqmm Cu. Ar. Cable.(including labour amount) |
| 44 | 2/3/3.5/4 C x 1.5 Sqmm Cu. Ar. XLPE Cable.(including labour amount) |
| 45 | 19C x 1.5 Sqmm Cu. Ar. XLPE cable.(including labour amount) |
| 46 | PART – G : MISCELLANEOUSSupply & Erection of Single Phase 20A Enclosure with 20A DP MCB for incoming control (including labour amount)Supply and Erection of the following: |
| 47 | 11KV Danger board |
| 48 | 11KV Hand Cloves (right & left) with suitable box(including labour amount) |
| 49 | i. Round Bottom fire bucket.(9 Litre)ii. Fire Bucket stand (suitable for 4 Bucket). |
| 50 | First Aid box with medicine. |
| 51 | Fuse Puller.(including labour amount) |
| 52 | First Aid chart with frame (both Tamil & English) |
| 53 | Dry powder type extinguisher 5 kgs |
| 54 | 6mm Thick 1000mm width 2000mm long rubber mat.( 5 NOS) |
| 55 | PART – H : ELECTRICAL INSPECTORATE EXPENSES :Preparation of drawings Submitting the same to the Cheif Electrical Inspectorate to Govt., following with them and getting approval from CEIG office.(Incidental Expenses included) |
| 56 | As per Approved drawing completing the work part by part submitting completion report for the entire installation arranging inspection, getting defect report, submitting rectification report and getting the safety certificate from electrical inspectorate office.(Incidental Expenses included) |
| 57 | PART – I : TNEB EXPENSES :Liasion with TNEB including submission of application forms, obtaining load sanction and other associated works. |
| 58 | TNEB DEMAND EXPENSES |
| 59 | PART – J : CIVIL WORKSCIVIL WORKS FOR TRANSFORMER YARD AND EARTH PITS |
| 60 | Add G.S.T @ 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysDec 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender