Housing Urban and Rular Development Government Departments Closing in 14 days TDR #58625340

Tender For Special Repairs To Electrical Installations By Renewal Of Ups Arrangements In Male Ward, Ae Ward, Dialysis Centre, Blood Bank In Government Hospital At Bodinayakanur In Theni District.

Issued by Government Departments · Theni, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
05 Dec 2026
14 days left
EMD
3000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Theni → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repairs To Electrical Installations By Renewal Of Ups Arrangements In Male Ward, Ae Ward, Dialysis Centre, Blood Bank In Government Hospital At Bodinayakanur In Theni District.

BOQ

Name of Work:- Special Repairs to Electrical Installations by Renewal of UPS arrangements in Male Ward, AE Ward, Dialysis Centre, Blood Bank in Government Hospital at Bodinayakanur in Theni District.
Sl. No. Item Description
1Renewal by Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting.
2Renewal by supply and fixing of 1200mm (48\\") sweep AC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 300mm down rod with fan clamp with side plates and cross arm of size 450mm (18\\")
3Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch on suitable module surface mounting Box (GI ) with module cover plate (plastic) on wall with connections. Higher End
4Renewal by Supply, erection, testing and commissioning of 1.5TR (4500 K.cal/hr) plastic split type Air conditioner with copper coil filted with high efficiency rotary compressor opearating on CFC free suitable for wall mounting for opearation on 230V 50Hz single phase AC supply with star ratting of 3 as per BEE specification and capable of performing the function.(1) Cooling (2)Dehumidifying (3) Air circulation (4) Filtering
5This installation works for the above split type AC units including the following (1) Mounting /Fitting Indoor and Outdoor units at their respective Locations. (2) Laying refrigerant pipe line of required length connecting both units after drilling hole/ holes in the wall if required. Thickness of the copper tubing shall not be less than 0.8 mm
6(3) Insulating the suction pipe with expanded polyethylene foam 5mm tubing. (4) Laying 1.5mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit.(5) Leak testing the entire system unit. (6) Charging refreigerantgas in the unit. (7) Suitable electric wiring to be provided with in 2.5sq.mm PVC insulated copper wire between indoor and outdoor units upto 6 mtrs length and upto switch within 3 mtrs of location of indoor unit. (carrier/Voltas /Blue star/equ)
7Renewal by Supply and Installation of 4 KVA Electronic Automatic Voltage Stabilizer V- GUARD make VND 500 Model with Input Voltage range of 150Volt-285Volt and Output Voltage range 200Volts to 230 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration.
8Renewal by Supply and erection of 2kVA Single Phase in Single phase out UPS with suitable capacity SMF battery to provide minimum 1 hour backup time under full load condition with connections complete.The Technical specifications of the inverter shall be as follows.
9a)Capacity 2000VA pure sinewave. b)Input voltage range 170V to 270V AC single phase. c)Output Voltage 230V AC Single phase. d)Back time 1 Hour. e)Digital indication Showing Mains ON, Invereter ON, Low Battery, Battery Voltage, Connected load in watts. f)fuse Protection, in built resettable circuit breaker Protection. (Inverter make Luminous/ Microtek or Eq) (Battery should be Exide /INVA Master/ Luminous make)
10Renewal by Supply and erection of suitable capacity SMF battery to provide minimum 1 hour backup time under full load condition with connections complete. The Technical specifications of the battery shall be as follows.a)Input voltage range 170V to 270V AC single phase. b)Output Voltage 230V AC Single phase. c)Back time 1 Hour. (Battery should be Exide /INVA Master/ Luminous make)
11Renewal by Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection 1.5 sq.mm copper wire with painting of suitable colour.
12Renewal by Supply and run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection 2.5 sq.mm copper wire with painting of suitable colour.
13Renewal by Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection 4 sq.mm copper wire with painting of suitable colour
14Renewal by Supply and fixing of 63A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with PWD Earthing.
15Renewal by Supply and fixing of 20A DP MCB with Sheet steel enclosure.
16Renewal by Supply and run of 2 of 2.5 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100V on 7/20 GI bearer wire for service connection mains
17Renewal by Supply and clarnping of 3-1/2 x 25 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps
18Supply and laying of 3-1/2 x 25sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.
19Renewal by Supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. PVC armoured LTUG cable with earth connection
20Renewal by Supply and providing cable end termination of 3-1/2x25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
21Supply and fixing of MS stand for fixing outdoor unit.
22Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug inflush with wall with earth connection (For AC Plug).
23Earthing as per PWD standard with an earth electrode of 2metre Class'B' GI pipe of dia not less than 32mm complete with necessary masonry work.
24Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection.
25GST@ 18% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58625340
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 05-12-2026
Authority
Authority Name Public Works Department
Work Description Tender for Special Repairs To Electrical Installations By Renewal Of Ups Arrangements In Male Ward, Ae Ward, Dialysis Centre, Blood Bank In Government Hospital At Bodinayakanur In Theni District.
Basic Detail
Tender No 21/DB/JDO-3/C-26/2026-10/Dt 18.11.2026
Bidding Type Tender
Location
City Theni
State Tamil Nadu
Key Dates
Publish Date 20 Nov 2026
Submission Date 05 Dec 2026
Open Date 07 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 3000
Exemption Not Available
Document List
943b3254-eba0-448b-80e4-70f2f778986f.html
BOQ_874318.xls
Tendernotice_1.pdf
tno203.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

943b3254-eba0-448b-80e4-70f2f778986f.html

xls

BOQ_874318.xls

pdf

Tendernotice_1.pdf

pdf

tno203.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender