Tender For Creation Of New 1X10 Mva Substation At Dablehar With New 4.7 Km 33 Kv Line On 11 Mtr. St Poles With 200 Mm Sq. Acsr Panther On Turnkey Basis.
Tender Value
4.73 Crore
Estimated cost
Bid Submission
09 Dec 2026
16 days left
EMD
9.48 Lakhs
Bank guarantee accepted
Document Fee
4000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Creation Of New 1X10 Mva Substation At Dablehar With New 4.7 Km 33 Kv Line On 11 Mtr. St Poles With 200 Mm Sq. Acsr Panther On Turnkey Basis.
BOQ
| Sl. No. | Item Description |
| 1 | SUBSTATION MAIN EQUIPMENT TRANSFORMER BAY, LINE BAY |
| 2 | 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type) 3-Phase, out door type circuit breaker and required accessories complete as per technical specification, scope of work & approved drawings confirming to IS standards |
| 3 | 33 kV Isolator with Earthing Blade (36kV,1250A, Outdoor, 3 poles, 25 kA) alongwith clamps for Panther conductor as per technical specification, scope of work & approved drawings confirming to IS standards |
| 4 | 33 kV Isolator without Earthing Blade (36KV,1250A, Outdoor, 3 poles, 25 KA) alongwith clamps for Panther conductor as per technical specification, scope of work & approved drawings confirming to IS standards |
| 5 | 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) alongwith clamps for Panther conductor of Ratio 400/200/100/5-5Amp as per Technical Specifications. (3 No. CTs in 1 set) |
| 6 | 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less alongwith clamps for Panther conductor. Station type lightening Arrestor mounting platform as per technical specifications. (3 No. LAs in 1 set). with individual earthings, Hot dipped galvanized 600mmx600mmx6mmthick plate welded with GI Strips for earthing of size 50mmX6mm for connection of lightening arrestor as per IS2629/85, GI Nuts and bolts,refilled with good earth, charcoal dust, salt, etc inside the Pit as per the direction of site engineer, enhancement material and earth chamber made of brick masonar with RCC slab cover |
| 7 | 33 kV SCADA compatible line C&R Panel alongwith O/F,E/F numerical relays with inrush blocking feature, IEC 61850 complaint , with minimum 16 DIs & 8 DOs , electrical reset master trip relay, mimic diagram , voltmeter, Ammeter, Annunciation windows with annuciation relays, mandatorily with Smart meter |
| 8 | 33 kV SCADA compatible Transformer C&R Panel alongwith Differential numerical relay & separate back up O/F,E/F numerical relays, IEC 61850 complaint ,with inrush blocking feature in both relays, with minimum 16 DIs & 8 DOs each , electrical reset master trip relay, mimic diagram , voltmeter, Ammeter, Annunciation windows with annuciation relays with Smart meter. |
| 9 | 33 kV Voltage Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ) alongwith clamps for Panther conductor & required accessoriesetc., complete as per technical specification, scope of work & approved drawings. (3 No. PTs in 1 set) |
| 10 | 33 kV Polymer Post Insulator 36kV,170kV Impulse, creepage distance 1224m |
| 11 | GANTRY STRUCTURE |
| 12 | Supply , Fabrication & Installation of G.I metal structures of sort sizes required to raise the height of power equipment above ground/floor level |
| 13 | Galvanized nuts and bolts |
| 14 | CONTROL CABLES |
| 15 | 12 Core 2.5 sqmm armoured, stranded copper conductor, PVC insulated and PVC sheathed cable with water swellable tape ( water tolerant) , 1.1 kV Grade, ISI, FRLS , including their termination materials like glands, lugs etc. |
| 16 | 6 Core 2.5 sqmm armoured, stranded copper conductor, PVC insulated and PVC sheathed cable with water swellable tape ( water tolerant) , 1.1 kV Grade, ISI, FRLS , including their termination materials like glands, lugs etc. |
| 17 | 4 Core 2.5 sqmm armoured, stranded copper conductor, PVC insulated and PVC sheathed cable with water swellable tape ( water tolerant) , 1.1 kV Grade, ISI, FRLS , including their termination materials like glands, lugs etc. |
| 18 | 2 Core 2.5 sqmm armoured, stranded copper conductor, PVC insulated and PVC sheathed cable with water swellable tape ( water tolerant) , 1.1 kV Grade, ISI, FRLS , including their termination materials like glands, lugs etc. |
| 19 | Lugs & Ferrules etc. |
| 20 | CONDUCTOR & HARDWARE |
| 21 | 200mm² ACSR Conductor Panther |
| 22 | Clamp for ACSR Panther Conductor for LA, PT, CT & VCB |
| 23 | Single Tension Fittings for ACSR Panther Conductor |
| 24 | Polymeric composite Disc Insulator 36KV with fittings, Lightening Impulse 170KV Positive and 180KV Negative, creepage distance 900mm,min failing load 70KN alongwith suitable fittings |
| 25 | Earth Wire 7/4.00 mm sq. |
| 26 | Plate Earthing of Substation- using GI strip of size 50x6mm welded with Galvanised Plate of size (600x600x6)mm, to be connected to 11KV Panel, LA and outgoing structure through GI strip. Earthing as per approved drawings with minimum scope of work as - Conventional GI plate earthing ( 600 mm X 600 mm X 6mm) , 40 mm dia., 3000 mm long GI pipe, 50x6 mm GI strip & 25x3 mm tied with GI plate electrode with test link, RCC pit, RCC cover plates on GI frame, 50 kg of bentonite powder per pit and other accessories complete to strengthen PTR and Auxiliary Transformer's earthing - Complete Job. The rate includes excavation of earthing Pit of 3 meter depth, disposal of excavated earth from site of earthing to outside to out side station. And backfilling should be using Good Earth, Charcoal Dust and Salt. Also. the rate should include provision of curing of earth plate using GI Pipe of size 1 inch with length of 3 Mtr, and making of chamber at the top with funnel and chamber cover |
| 27 | 10 MVA ,33/11 KV POWER TRANSFORMER & 11KV INDOOR SWITCHGEAR |
| 28 | 10 MVA, 33/11 kV, 3 ph, 50 Hz, ONAN, 99.9% pure electrolytic grade copper wound, with high permeability PRIME GRADE, CRGO with M4 Grade or Better core, Outdoor Conventional type Power Transformer (PTR) along with transformer oil, motorised On Load Tap Changer , RTCC & AVR to be supplied along with the OLTC , Buchholtz relay, breather, OTI & WTI, Marshalling Box, Conservator tank with air cell, oil level indicator, valves, 2 sets of 50x8 mm GS Neutral Earthing strips {(with braided conductor on bushing end), isolating link, isolation with insulators}, pressure relief device, with smart breather, control wiring between sensing equipment and marshalling box, cable supporting tray on the body of transformer, transformer wheels, LV/HV bushing etc as required as per technical specifications, approved drawings and scope of the work., Copper plate 600mmx600mmx6mm thick welded with copper Strips size 50mmX6mm for earthing of connection of neutral and body earthing seperately as per IS2629/85, Nuts and bolts, refilled with good earth, charcoal dust, salt, etc. inside the Pit as per approved drawings, Aluminium Busbars (100 mm x 10 mm) 30 mtr with post insulators and other accessories required for fitting it. Mandatory Minimum Weight of Core as 6500 kgMandatory Minimum Weight Coils as 3000 kg Mandatory Minimum weight of oil as 5500 kg & Warranty period of PTR shall be 5 years |
| 29 | 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Indoor) 1 no. incomer (600 / 300/5-5A) + 5 no. of outgoing ( 600/300/5-5A) (1set) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays and copper Bus bars, 3-phase Wire HT CT/PT operated Fully static Smart Energy meters ( 0.5S ) DLMS Compliant, with RS-485 port For 10 MVA (1+5), SCADA Compatible IEC 62271-100:2012 fitting with strip heater. |
| 30 | 11 kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (4/5/6 Sets) with conventional earthing as per direction fo site Engineer. |
| 31 | 11KV XLPE POWER CABLES |
| 32 | 11 kV 630 mm² Single Core Cable A2XFY (with one spare length) with extruded High-Density Polyethylene outer sheath , for 10 MVA Power Transformer. |
| 33 | 11 kV 300 mm² 3 core Cable A2XFY (with one spare length) with extruded High-Density Polyethylene outer sheath , for 10 MVA Power Transformer. |
| 34 | 11 kV 1CX630 sq mm Indoor Heat Shrinkable Cable Termination Kits for incoming Cable and to be installed by Cable kit OEM's certified technical person only. |
| 35 | 11 kV 1CX630 sq mm Outdoor Heat Shrinkable Cable Termination Kits for incoming Cable and to be installed by Cable kit OEM's certified technical person only. |
| 36 | 11KV Cable Kits (Indoor) 300mm² 3-Core |
| 37 | 11KV Cable Kits (outdoor) 300mm² 3-Core |
| 38 | 11 KV isolator, double break, 3 pole, 800 Amp. Horizontal mounting type with earth switch. |
| 39 | 100 kVA,11/0.433 KV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound energy efficeincy level-2 transformer) |
| 40 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp |
| 41 | 120 mm2 PVC LT Cable 4 Core, armoured, FRLS |
| 42 | ST pole 9 Mtrs.long (ST-410 SP 33) including allied material |
| 43 | Red Oxide |
| 44 | Aluminium Paint |
| 45 | Cement bottoming 1:2:4 mix as per REC standards 0.7cum per pole |
| 46 | Earthing Complete by Gl Pipe 40 mm or Gl Rod 20mm 2.5 mtr long through Gl strip 50x6mm |
| 47 | Galvanised iron of sorts |
| 48 | Earthing of 100KVA substation - Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 75 mm x10 mm & 50 mm x 6 mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, pit refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 49 | MCCB-200 Amps with Box |
| 50 | COMMON MISCELLANEOUS EQUIPMENTS |
| 51 | Telecommunication Facilities with internet connection and sim connections. alongwith handset. LED TV. |
| 52 | a) VRLA type Battery Bank 30 V, 200 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelene copolymer container,flame retardant. (Three no. standby cells ) b) 30V,200 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 3Phase, 50 HZ AC Input Supply . |
| 53 | Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories , control room emergency DC lighting including 20% as spare as per technical specifications, approved drawings and scope of works. |
| 54 | Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories, having 20% spare outgoing feeders, mounting arrangements etc as per technical specifications, approved drawings and scope of works. |
| 55 | Rubber Mat 1mx2m 3 mm thick |
| 56 | Fire Extingiusher Co₂ Type of 4.5 kg capacity for control room |
| 57 | CO2 type trolly mounted of 22.5 kg. capacity for switch yard. |
| 58 | Sand buckets 03 no. with stand in outdoor yard |
| 59 | Safety Helmet |
| 60 | Rubber Gloves for 33 kV level |
| 61 | Rubber Gloves for 11kV level |
| 62 | Safety Belt |
| 63 | Safety Shoes |
| 64 | Earthing rod (set of 3 rods) |
| 65 | HV Detectors (Contactless) all voltages upto 33/66 KV |
| 66 | Tool kit for routine maintenance. (like crimping tool, screw drivers, plier, spanner & wire stripper.) |
| 67 | Digital Megger 5000 MΩ |
| 68 | Search Light Chargeable |
| 69 | 100 KVA, 3-phase SERVO Voltage Stablizer i/p voltage range of 340 v - 480 v (or 295 v -465 v) O/p of 400 v - 415 v +1% at 50 Hz, ONAN |
| 70 | GI Flat for earthing |
| 71 | Operation of Sub Station by way of providing skilled manpower for 365 days in shifts ( 3 shift x 2 persons + 1 one spare = 7 persons) |
| 72 | CIVIL WORKS |
| 73 | Development of land including filling of land, cutting and levelling of land by removing weeds, wild grass and endulation if any, ornamental land scaping and growing of ornamental trees in unbuilt areas and road sides (wherever required)Development of roads by interlock tiles including excavation (complete job) for creation of pathway 170 sqm from main gate to control room, yard and JE / SBA Quarters along with surface drains. The filling of goodearth in the depressed are to raise the level acquired land one feet above the main road level in order to prevent the water logging inside the Receving station. |
| 74 | Compound Walling of identified land by way of mass concrete in foundations and 228mm brick wall of 2M height & plastring, Painting of complete boundry wall including 2 coats of putty with exterior emulsion and installation of Main Gate (width8 mtr, height 3 mtr) incl. suporting column & pillar with interior small gate. |
| 75 | Chain link fencing of 33KV switch yard of sub-station by way of mass concrete in foundation and chain link fencing of 6fts height. (as per approved Drawing by Competent Authority) along with mesh fencing gate of dimension 5.40 m x 1.85 m. |
| 76 | HDPE Pipe Outer Dia 300mm, Inner Dia 295mm for laying of 11kV XLPE Cable from Power Transformer to Control Room |
| 77 | RCC Cable Trench with separate perfroated trays for laying of 11kv XLPE Power Cable & control cables from Power Transformer to Control Room with RCC cover. |
| 78 | 33 KV yard concreting 1:4:8 with 20 mm nominal stone aggregate 4\\" thick/ Metalling and laying of gravels 20 mm (complete in outdoor yard. (Complete job) |
| 79 | 33 KV all Equipment Foundation & Gantary foundation, as per standards in RCC M20 grade (1:1.5:3) as per technical specifications & approved drawings from the Competent Authority |
| 80 | 33/11kV Power Transformer Foundation suitable for 10 MVA (25 cum each) in RCC M20 grade (1:1.5:3) as per technical specifications & approved drawings from the Competent Authority |
| 81 | i) Control Room Building as per JKPDD standards with RCC Column /Beam Frame Structures having bearing capacity of 1 JE Room, 1 store room, 1 battery room, Washroom and a main Hall including Aluminium Windows & Doors, RCC roof with waterproofing, Granite flooring, RCC stair case. ii) RCC Cable Ducts with cable tray for power cables and control cables and covered with 10 mm MS checkerd Steel Plate, Toilet (with WC, washbasin and fittings), electric fittings (i.e. fans, LED tube lights and all other electric fixtures), Complete with all civil protection works as per technical specifications , approved drawings from the Competent Authority. iii) Painting of complete CR Building including 2 coats of putty with emulsion (exterior & interior), Doors and windows etc. iv) 2 Office tables and 6 no of chairs, 4 no. 2-Ton split type Airconditioners and water supply to toilet, septic tank of size 6 feet x 9 feet x 8 feet (LxBxH), overhead tank of plastic of 1000 ltrs.v) The level of foundations of Control room building should be two feet higher than the level of main road.vi) Seperate independent earthing (2 Nos of 40mm GI Pipe/3-m long) as required as per technical specifcations, approved drawings and scope of work.vii) 24 V Invertor with 200AH Batteriesviii) Flooring with vitrified tilesThe scope of work also includes geotechnical investigation for safe bearing capacity and preparation of Architechtural/Structural design from Govt. approved agencies. |
| 82 | i) JE / Shift SBA Quarters (C type) including with fully furnished modular kitchens and including furniture i.e single bed with mattress. 3 no. and 3 no. with double bed with matresses, ii) Steel almirah 4 no., 5 seater sofa set 2 no, Executive chair 4 no. and normal chairs 10 no.. ( for JE and SBA Quarter alongwith pantry & wash room with water proofing rooftop. iii) 2 no. Center Table, 2 Normal Tables , 25 ltrs Geysers 3 no. and water cooler with RO, Refrigerator 300 ltrs. of reputed make, ceiling fans 10 no. |
| 83 | Yard Lighting complete with earthing, cement bottoming, G.I bracket, cable & control box with 2x60 watt LED lights at 6 locations on 9 mtr ST Poles |
| 84 | Installation of Hand Pump including drilling of borewell, lowering of suitable delivery pipes, electrical connections, Starter / control Panel and all necessary accessoies as per departmental specifications with an overhead water storage tank capacity 2000 lits with all connections with the building |
| 85 | Earthing mat to be laid with G.I flat 50x8 mm for earth mat as per technical specifications & approved drawings from the Competent Authority. |
| 86 | Earthing Electrode (3m long 40mm dia GI pipe) through GI strip |
| 87 | Aluminium Double Telescopic Ladder 6.3 meter Wall support 20 feet with mag Hinge and Stabilizer Multi Purpose Ladder Load Capacity 150 kgs |
| 88 | Oil BDV Tester( as per technical Specification attached in the tender document) |
| 89 | Insulation Tester( as per technical Specification attached in the tender document) |
| 90 | SUPPLY, ERECTION, LAYING, STRINGING, TESTING & COMMISSIONING OF 33KV LINE (4.7 Kms.) & ERECTION OF 3 No ISOLATION POINT including Geotagging offline after erection. |
| 91 | 11 mtr ST Long Pole (ST 410 SP-56) |
| 92 | 13 mtr ST Long Pole (ST 410 SP-69) |
| 93 | 16 mtr ST Long Pole (ST 410 SP-80) |
| 94 | Gl V cross-arm with top Bracket including clamp & Gl Channel X-arm including clamps and braces |
| 95 | 200 mm2 ACSR Panther Conductor |
| 96 | PG Clamps for 100 mm2 ACSR Conductor |
| 97 | 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 98 | 33kV Polymeric composite Disc Insulator 36kV with fittings, min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm alongwith suitable fittings |
| 99 | 33 kV Isolator with Earthing Blade (36KV,1250A, Outdoor, 3 poles, 25 KA) alongwith clamps for Panther conductor |
| 100 | Galvanized Nuts and Bolts. |
| 101 | Danger Plates with Clamps |
| 102 | Anti-Climbing Device with Clamps and barbed wire |
| 103 | Earthing Complete by Gl Pipe 40 mm or Gl Rod 20mm 2.5 mtr long through Gl Strip 25x5mm |
| 104 | Red Oxide |
| 105 | Aluminium Paint |
| 106 | Cement bottoming 1:2:4 mix as per REC standards .6cum /pole |
| 107 | Aluminium Jointing Sleeves |
| 108 | Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator (2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia Gl stranded wire complete |
| 109 | Guard Netting (with GI wire 8 SWG, GI Channel X-arm including clamps and braces, Eye Bolts) |
| 110 | Supply and installation of Non Communicable 33 KV Fault Passage Indicators ( as per technical Specification attached in the tender document) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysDec 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender