Bids Are invited for Taking Downout Unserviceable Or Serviceable Ug Cables Of Any Cross Sectional Area And Connections Including Bricks Gi Pipes Etc - Taking Downout Unserviceable Or Serviceable Ug Cables Of Any Cross Sectional Area And Connections I
Tender Overview
Project Description
Bids Are invited for Taking Downout Unserviceable Or Serviceable Ug Cables Of Any Cross Sectional Area And Connections Including Bricks Gi Pipes Etc - Taking Downout Unserviceable Or Serviceable Ug Cables Of Any Cross Sectional Area And Connections Including Bricks Gi Pipes Etc. Of Any Descriptions Laid In Trenches Andor Fixing With Wallspoles Including Segregating Of Serviceable Materials Viz Bricks Cables Gi Pipes Etc. And Keep In Safe Custody For Reuse Complete All As Specified And As Directed. Note Earth Work Shall Be Measured And Paid For Separately Under Relevant Items. , Laying Only In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Galvanised Steel Strip 1100 Volts Grade Cross Sectional Area 10 Sqmm 4 Core - Laying Only In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 10 Sqmm 4 Core. , All As Per Item Sl No. 2 Above But Of Size 16 Sqmm 4 Core , All As Per Item Sl No. 2 Above But Of Size 25 Sqmm 3.5 Core. , All As Per Item Sl No. 2 Above But Of Size 50 Sqmm 3.5 Core. , All As Per Item Sl No. 2 Above But Of Size 70 Sqmm 3.5 Core , All As Per Item Sl No. 2 Above But Of Size 95 Sqmm 3.5 Core. , Relaying Fixing Or Passing Through Pipe Xlpe Insulated Armoured Electric Power Ug Cable 1100 Volt Grade Nominal Crosssectional Area 10 Sqmm 4 Core - Relayingfixing Or Passing Through Pipe Xlpe Insulated Armoured Electric Power Ug Cable Heavy Duty With Aluminium Conductor 1100 Volt Grade Nominal Crosssectional Area 10 Sqmm 4 Core Including Brass Compression Cable Gland Terminal Lug Etc. Complete All As , All As Per Item No. 8 Above But Nominal Crosssectional Area 16 Sqmm 4 Core. , All As Per Item No. 8 Crosssectional Area 25 Sqmm 3 1By 2 Core. - All As Per Item No. 8 Above But Nominal Crosssectional Area 25 Sqmm 3 One By 2 Core. , All As Per Item No 8 Crosssectional Area 50 Sqmm 3 1 By 2 Core. - All As Per Item No 8 Above But Nominal Crosssectional Area 50 Sqmm 3 One By 2 Core. , All As Per Item No. 8 Above But Nominal Crosssectional Area 70 Sqmm 3 One By 2 Core. - All As Per Item No. 8 Above But Nominal Crosssectional Area 70 Sqmm 3 1 By 2Core. , Excavating In Trenches Not Exc. 1.50 Mtr Wide And Not Exc. 1.50 Mtr In Depth Getting Out In Soft Loose Soil Complete All As Specified And As Directed. - Excavating In Trenches Not Exc. 1.50 Mtr Wide And Not Exc. 1.50 Mtr In Depth Getting Out In Soft Loose Soil Complete All As Specified And As Directed. , Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exc. 250Mm In Softloose Soil Complete All As Specified And As Directed. - Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exc. 250Mm In Soft Loose Soil Complete All As Specified And As Directed. , Removing Excavated Materials Soils Not Exc. 50.00 Mtr And Depositing Where Directed At A Level Not Exc. 1.50 Mtr Above The Starting Point In Soil Complete All As Specified And As Directed. , Ml Sand Cushioning Dry In Trenches For Protection Of Ug Cables Below Above And Around The Ug Cable Laid In Trenches Of 230Mm Spread Thickness - Ml Sand Cushioning Dry In Trenches For Protection Of Ug Cables Below Above And Around The Ug Cable Laid In Trenches Of 230Mm Spread Thickness And Consolidated Punned Upto 180Mm Thickness Complete All As Specified And As Directed. Note For The Purpose Of Payment Punned Thickness Of Sand Cushioning Only Shall Be Measured And Paid . , Ml For Fly Ash Bricks Locally Available Laid Dry Width Wise Across The Line Of Cable In Trenches For Protection Of Ug Cable Complete All As Specified And As Directed. , Taking Downout Unserviceable Gi Hdpe Pipes Of Any Descriptions Laid In Trenches Andor Fixing With Wallspoles Complete All As Specified And As Directed. , S F 50 Mm High Density Polyethylene Pipe Hdpe Of Pressure Rating 6 Kgfcm Fixed Complete To Walls Ceilings Or In Floors Etc. Complete All As Specified And Directed. - S F 50 Mm High Density Polyethylene Pipe Hdpe Of Pressure Rating 6 Kg Cm Fixed Complete To Walls Ceilings Or In Floors Etc. Complete All As Specified And Directed. , Sf Galvanised Iron Pipe 80Mm Bore Dia Light Grade For Protection Of Ug Cable Laid In Floors Road Crossing Fixing To Pole With Mild Steel Clamps Nuts Bolts - Sf Galvanised Iron Pipe 80Mm Bore Dia Light Grade For Protection Of Ug Cable Laid In Floors Road Crossing Fixing To Pole With Mild Steel Clamps Nuts Bolts Etc. Complete All As Specified And As Directed. , Sf Galvanised Iron Pipe 50Mm Bore Dia Light Grade For Protection Of Ug Cable Laid In Floors Road Crossing Fixing To Pole With Mild Steel Clamps Nuts Bolts - Sf Galvanised Iron Pipe 50Mm Bore Dia Light Grade For Protection Of Ug Cable Laid In Floors Road Crossing Fixing To Pole With Mild Steel Clamps Nuts Bolts Etc. Complete All As Specified And As Directed. , Sf Galvanised Iron Pipe 100Mm Bore Dia Light Grade For Protection Of Ug Cable Laid In Floors Road Crossing Fixing To Pole With Mild Steel Clamps - Sf Galvanised Iron Pipe 100Mm Bore Dia Light Grade For Protection Of Ug Cable Laid In Floors Road Crossing Fixing To Pole With Mild Steel Clamps Nuts Bolts Etc. Complete All As Specified And As Directed. , Labour Only For Horizontal Boring For Passing Protection Pipe Up To 80Mm Bore Dia. Under Road Foot Path Not Exc. 10.00 Mtr In A Single Length - Labour Only For Horizontal Boring For Passing Protection Pipe Up To 80Mm Bore Dia. Under Road Foot Path Not Exc. 10.00 Mtr In A Single Length Complete All As Specified And As Directed. , Ml Straight Through Cable Joint Kit Including Jointing Materials For Making Joints Of Ug Electric Cable 1100 Volt Grade Sectional Area 10 Sqmm To 16 Sqmm 4 Core - Ml Straight Through Cable Joint Kit Including Jointing Materials For Making Joints Of Ug Electric Cable 1100 Volt Grade Heavy Duty With Pvcxlpe Insulated Aluminium Stranded Conductor Nominal Crosssectional Area 10 Sqmm To 16 Sqmm 4 Core And Testing Complete All As Specified And As Directed. , Ml Straight Through Cable Joint Kit Including Jointing Materials For Making Joints Of Ug Electric Cable 1100 Volt Grade Heavy Duty Crosssectional Area 25 Sqmm To 50 Sqmm 3 1 By 2Core - Ml Straight Through Cable Joint Kit Including Jointing Materials For Making Joints Of Ug Electric Cable 1100 Volt Grade Heavy Duty With Pvcxlpe Insulated Aluminium Stranded Conductor Nominal Crosssectional Area 25 Sqmm To 50 Sqmm 3 One By 2 Core And Testing Complete All As Specified And As Directed. , All As Per Item No. 25 Above But Of Nominal Crosssectional Area Exc. 70120 Sqmm 3 1 By2 Core And Testing Complete All As Specified And As Directed - All As Per Item No. 25 Above But Of Nominal Crosssectional Area Exc. 70120 Sqmm 3 One By 2 Core And Testing Complete All As Specified And As Directed. , S F Hdpe Dwc Double Walled Corrugated Of Diameter 25 Mm Including Disconnection And Connection Of Cable Near Paneloh For Pipe Fixing Including Joints Complete All As Directed - S F Hdpe Dwc Double Walled Corrugated Of Diameter 25 Mm Including Disconnection And Connection Of Cable Near Paneloh For Pipe Fixing Including Joints Complete All As Directed. , S F Hdpe Dwc Double Walled Corrugated Of Diameter 40 Mm Including Disconnection And Connection Of Cable Near Paneloh For Pipe Fixing Including Joints Complete All As Directed. , S F Hdpe Dwc Double Walled Corrugated Of Diameter 50 Mm Including Disconnection And Connection Of Cable Near Paneloh For Pipe Fixing Including Joints - S F Hdpe Dwc Double Walled Corrugated Of Diameter 50 Mm Including Disconnection And Connection Of Cable Near Paneloh For Pipe Fixing Including Joints Complete All As Directed. , S F Hdpe Dwc Double Walled Corrugated Of Diameter 100 Mm Including Disconnection And Near Panel Oh For Pipe Fixing - S F Hdpe Dwc Double Walled Corrugated Of Diameter 100 Mm Including Disconnection And Connection Of Cable Near Paneloh For Pipe Fixing Including Joints Complete All As Directed. , Ml For Earthing Complete With Ms Galvanized Plate Of Size 60Cm 60Cm 6Mm As Earth Electrode Buried Directly In Ground Earth Pit Not Less Than 2.25 Mtrs Deep Below Ground Level - Ml For Earthing Complete With Ms Galvanized Plate Of Size 60Cm 60Cm 6Mm As Earth Electrode Buried Directly In Ground Earth Pit Not Less Than 2.25 Mtrs Deep Below Ground Level With Top Edge Of The Plate Not Less Than 1.5 Mtrs Below Normal Ground Level Connected To Galvanised Iron Strip 32 6Mm As Earthing Lead By Means Of Bolts Nuts Check Nuts And Washers Of Galvanised Ironwelding Or Steel All As Shown In Electrical Plate No 3 In Ssr Part I Of 2009 Rcc Coverci Ms Cover Having Suitable Handle 10Mm Ms Rod 20Mm Dia Gi Medium Grade Watering Pipe With Gi Funnel With Wire Mesh 40Mm Bore Gi Pipe Medium Grade Isi Marked For Protection Of Earth Lead Conductor And Testing , 06 Sqmm To 16 Sqmm , 25 Sqmm To 50 Sqmm , 70 Sqmm To 95 Sqmm , 120 Sqmm To 240 Sqmm , M L For Mild Steel N 5 Cm Long And Of Neck 5 To 10 Mm Complete All As Specified And Directed. - M L For Mild Steel Nuts Bolts Machine Made With Hexagonal Or Square Heads At One End And Screwed The Other Or Screwed Both Ends Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut N Exc 5 Cm Long And Diameter Of Neck 5 To 10 Mm Complete All As Specified And Directed. , Material And Labour For Painting Of Outdoorindoor Feeder Pillar Boxes Of Ms Sheet With Spray Gun After Scrapping Old Surfaces Any Size Complete All As Specified And Directed - Material And Labour For Painting Of Outdoorindoor Feeder Pillar Boxes Of Ms Sheet With Spray Gun After Scrapping Old Surfaces Any Size Complete All As Specified And Directed By Engrincharge , Supply And Fix Metal Cable Route Indicator Of Height 750 Mm Ms Flat Of 40 Mm X 4 Mm With Circular 100 Mm Diameter 150 Mm Below Ground Level With Pcc 136 40 Mm Aggregate - Supply And Fix Metal Cable Route Indicator Of Height 750 Mm Ms Flat Of 40 Mm X 4 Mm With Circular 100 Mm Diameter Ms Sheet Of Minimum Thickness 3 Mm Duly Engraved Lt Cable Including Aluminium Paint Over It And To Be Fixed 150 Mm Below Ground Level With Pcc 136 40 Mm Aggregate Of Size 250X250x300 Mm All As Directed By Engrincharge , Dismantling Existing Lt Panels Of Any Type Any Size Carefully For Reuse Including Necessary Excavation Demolition Of Concrete Disconnecting Of Earthing Cable Taking Out Burn Out Lugsmccbs - Dismantling Existing Lt Panels Of Any Type Any Size Carefully For Reuse Including Necessary Excavation Demolition Of Concrete Disconnecting Of Earthing Cable Taking Out Burn Out Lugsmccbsbus Barsinsulators And Other Connected Works Surface Levelling Etc And Removing The Old Unserviceable Rubbish Burn Out Lugsmccbsbus Barsinsulators Etc And Refixing The Lt Panels After Repairreplacement Of Burn Out Lugsmccbsbus Barsinsulators Etc Including Reconnection Of Earthing Cables With New Foundation Of Panels With Brick Works Pcc Worksetc Complete All As Specified And As Directed By Engrincharge.Note Earth Workbrick Workspcclugsmccbbus Barinsulators Etc Shall Be Measured And Paid For Separately Under Relevant Items. , Sf Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates Rails Braces - Sf Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates Rails Braces Etc. Complete Drilled For Fixing Of Steel Sheeting Or Other Covering Doors Etc To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings Exclusive Of Steel Sheeting Or Other Covering Running Rails And Guides And Hanging Also Fastening And Fixing Complete. , M L For Cross Arms Bracing Supports Clamps And Back Plates Fabricated From Structural Steel Sections Including Nuts Bolts Washers - M L For Cross Arms Bracing Supports Clamps And Back Plates Fabricated From Structural Steel Sections Including Nuts Bolts Washers Welding Bending Cold Or Hot Drilling Holes For Bolts In Any Shape Or Size As Directed Inclusive Of 2 Coats Of Aluminium Paint Over A Coat Of Red Oxide Primer Complete All As Specified And As Directed. , Ml Pcc 136 Type C2 Using 40Mm Graded Aggregate As In Foundation For Stay Set Pole Panels Etc Including Fair Finish Even And Fir To Exposed Surfaces - Ml Pcc 136 Type C2 Using 40Mm Graded Aggregate As In Foundation For Stay Set Pole Panels Etc Including Fair Finish Even And Fir To Exposed Surfaces Without Using Extra Cement Complete All As Specified And As Directed. , M L Pcc 124 Type B1 With Using 20 Mm Graded Stone Aggregate As Coping Of Polepanel Including Necessary Form Work As Required Complete All As Directed , M L For Brick In Cm 14 Rendering Using Sub Class B Bricks Straight Or Curved On Plan Exceeding 6 Mtr Mean Radius Including Dismantling Old Structure All As Specified And Directed. , M L For 15Mm Thick In Cm 14 Rendering On Fair Face Of Brick Work Finished Even Fair Complete All As Specified Directed. , M L For Hardcore Of Gauge N Exc. 63 Mm Deposited Spread And Levelled In Layers N Exc. 15 Cm Thick Watered And Rammed To A True Surface As Specified And Directed. , Sf Al Busbar Rating As Required Amps Including Making Holes For Connections And Colour Coding As Per Existing Busbar Including Taking Down - Sf Al Busbar Rating As Required Amps Including Making Holes For Connections And Colour Coding As Per Existing Busbar Including Taking Down Old Unserviceable One Complete All As Specified And Directed , Sf In Wiring Single Core Stranded Copper Conductor Frls Of Size 16 Sqmm Including Copper Lugs At Both Ends Complete All As Specified And Directed , Sf In Wiring Single Core Stranded Copper Conductor Frls Of Size 10 Sqmm Including Copper Lugs At Both Ends Complete All As Specified And Directed , Taking Downdismantling Of Unserviceable Lt Panels Complete All As Specified And Directed By Engineerincharge
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Taking downout unserviceable or serviceable UG Cables of any Cross Sectional Area and Connections including Bricks GI Pipes etc | Taking downout unserviceable or serviceable UG Cables of any Cross Sectional Area and Connections including Bricks GI Pipes etc. of any descriptions laid in Trenches andor fixing with WallsPoles including Segregating of Serviceable Materials viz Bricks Cables GI Pipes etc. and keep in Safe custody for reuse complete all as specified and as directed. NOTE Earth Work shall be Measured and Paid for separately under relevant items. |
| 2 | Laying only in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip 1100 volts grade cross sectional area 10 sqmm 4 core | Laying only in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 10 sqmm 4 core. |
| 3 | All as per Item Sl No. 2 above but of size 16 Sqmm 4 Core | All as per Item Sl No. 2 above but of size 16 Sqmm 4 Core |
| 4 | All as per Item Sl No. 2 above but of size 25 Sqmm 3.5 Core. | All as per Item Sl No. 2 above but of size 25 Sqmm 3.5 Core. |
| 5 | All as per Item Sl No. 2 above but of size 50 Sqmm 3.5 Core. | All as per Item Sl No. 2 above but of size 50 Sqmm 3.5 Core. |
| 6 | All as per Item Sl No. 2 above but of size 70 Sqmm 3.5 Core | All as per Item Sl No. 2 above but of size 70 Sqmm 3.5 Core |
| 7 | All as per Item Sl No. 2 above but of size 95 Sqmm 3.5 Core. | All as per Item Sl No. 2 above but of size 95 Sqmm 3.5 Core. |
| 8 | ReLaying Fixing or Passing through Pipe XLPE insulated Armoured Electric Power UG Cable 1100 Volt Grade Nominal CrossSectional Area 10 Sqmm 4 Core | ReLayingFixing or Passing through Pipe XLPE insulated Armoured Electric Power UG Cable Heavy Duty with Aluminium Conductor 1100 Volt Grade Nominal CrossSectional Area 10 Sqmm 4 Core including Brass Compression Cable Gland Terminal Lug etc. complete all as |
| 9 | All as per Item No. 8 above but Nominal CrossSectional Area 16 Sqmm 4 Core. | All as per Item No. 8 above but Nominal CrossSectional Area 16 Sqmm 4 Core. |
| 10 | All as per Item No. 8 CrossSectional Area 25 Sqmm 3 1by 2 Core. | All as per Item No. 8 above but Nominal CrossSectional Area 25 Sqmm 3 one by 2 Core. |
| 11 | All as per Item No 8 CrossSectional Area 50 Sqmm 3 1 by 2 Core. | All as per Item No 8 above but Nominal CrossSectional Area 50 Sqmm 3 one by 2 Core. |
| 12 | All as per Item No. 8 above but Nominal CrossSectional Area 70 Sqmm 3 one by 2 Core. | All as per Item No. 8 above but Nominal CrossSectional Area 70 Sqmm 3 1 by 2Core. |
| 13 | Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth getting out in Soft Loose Soil complete all as specified and as directed. | Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth getting out in Soft Loose Soil complete all as specified and as directed. |
| 14 | Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in SoftLoose Soil complete all as specified and as directed. | Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in Soft Loose Soil complete all as specified and as directed. |
| 15 | Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil complete all as specified and as directed. | Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil complete all as specified and as directed. |
| 16 | ML Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable laid in Trenches of 230mm Spread thickness | ML Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable laid in Trenches of 230mm Spread thickness and consolidated punned upto 180mm thickness complete all as specified and as directed. NOTE For the purpose of Payment Punned thickness of Sand Cushioning only shall be Measured and Paid . |
| 17 | ML for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed. | ML for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed. |
| 18 | Taking downout unserviceable GI HDPE Pipes of any descriptions laid in trenches andor fixing with WallsPoles complete all as specified and as directed. | Taking downout unserviceable GI HDPE Pipes of any descriptions laid in trenches andor fixing with WallsPoles complete all as specified and as directed. |
| 19 | S F 50 mm High density polyethylene pipe HDPE of pressure rating 6 kgfcm fixed complete to walls ceilings or in floors etc. complete all as specified and directed. | S F 50 mm High density polyethylene pipe HDPE of pressure rating 6 kg cm fixed complete to walls ceilings or in floors etc. complete all as specified and directed. |
| 20 | SF Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts | SF Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts etc. complete all as specified and as directed. |
| 21 | SF Galvanised Iron Pipe 50mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts | SF Galvanised Iron Pipe 50mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts etc. complete all as specified and as directed. |
| 22 | SF Galvanised Iron Pipe 100mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps | SF Galvanised Iron Pipe 100mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts etc. complete all as specified and as directed. |
| 23 | Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia. under Road Foot Path not exc. 10.00 mtr in a Single Length | Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia. under Road Foot Path not exc. 10.00 mtr in a Single Length complete all as specified and as directed. |
| 24 | ML Straight Through Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Sectional area 10 Sqmm to 16 Sqmm 4 Core | ML Straight Through Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVCXLPE insulated Aluminium Stranded Conductor Nominal CrossSectional area 10 Sqmm to 16 Sqmm 4 Core and Testing complete all as specified and as directed. |
| 25 | ML Straight Through Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty CrossSectional area 25 Sqmm to 50 Sqmm 3 1 by 2Core | ML Straight Through Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVCXLPE insulated Aluminium Stranded Conductor Nominal CrossSectional area 25 Sqmm to 50 Sqmm 3 one by 2 Core and Testing complete all as specified and as directed. |
| 26 | All as per Item No. 25 above but of Nominal CrossSectional area exc. 70120 Sqmm 3 1 by2 Core and Testing complete all as specified and as directed | All as per Item No. 25 above but of Nominal CrossSectional area exc. 70120 Sqmm 3 one by 2 Core and Testing complete all as specified and as directed. |
| 27 | S F HDPE DWC Double Walled Corrugated of Diameter 25 mm including disconnection and connection of cable near panelOH for pipe fixing including joints complete all as directed | S F HDPE DWC Double Walled Corrugated of Diameter 25 mm including disconnection and connection of cable near panelOH for pipe fixing including joints complete all as directed. |
| 28 | S F HDPE DWC Double Walled Corrugated of Diameter 40 mm including disconnection and connection of cable near panelOH for pipe fixing including joints complete all as directed. | S F HDPE DWC Double Walled Corrugated of Diameter 40 mm including disconnection and connection of cable near panelOH for pipe fixing including joints complete all as directed. |
| 29 | S F HDPE DWC Double Walled Corrugated of Diameter 50 mm including disconnection and connection of cable near panelOH for pipe fixing including joints | S F HDPE DWC Double Walled Corrugated of Diameter 50 mm including disconnection and connection of cable near panelOH for pipe fixing including joints complete all as directed. |
| 30 | S F HDPE DWC Double Walled Corrugated of Diameter 100 mm including disconnection and near panel OH for pipe fixing | S F HDPE DWC Double Walled Corrugated of Diameter 100 mm including disconnection and connection of cable near panelOH for pipe fixing including joints complete all as directed. |
| 31 | ML for earthing complete with MS galvanized plate of size 60cm 60cm 6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs deep below ground level | ML for earthing complete with MS galvanized plate of size 60cm 60cm 6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs deep below ground level with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised iron strip 32 6mm as earthing lead by means of bolts nuts check nuts and washers of galvanised ironwelding or steel all as shown in electrical plate No 3 in SSR part I of 2009 RCC coverCI MS cover having suitable handle 10mm MS Rod 20mm dia GI medium grade watering pipe with GI funnel with wire mesh 40mm bore GI pipe medium grade ISI marked for protection of earth lead conductor and testing |
| 32 | 06 sqmm to 16 sqmm | 06 sqmm to 16 sqmm |
| 33 | 25 sqmm to 50 sqmm | 25 sqmm to 50 sqmm |
| 34 | 70 sqmm to 95 sqmm | 70 sqmm to 95 sqmm |
| 35 | 120 sqmm to 240 sqmm | 120 sqmm to 240 sqmm |
| 36 | M L for mild steel n 5 cm long and of neck 5 to 10 mm complete all as specified and directed. | M L for mild steel nuts bolts machine made with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut n exc 5 cm long and diameter of neck 5 to 10 mm complete all as specified and directed. |
| 37 | Material and labour for Painting of outdoorindoor Feeder Pillar Boxes of MS Sheet with spray gun after scrapping old surfaces any size complete all as specified and directed | Material and labour for Painting of outdoorindoor Feeder Pillar Boxes of MS Sheet with spray gun after scrapping old surfaces any size complete all as specified and directed by EngrinCharge |
| 38 | Supply and Fix Metal cable route indicator of height 750 mm MS Flat of 40 mm x 4 mm with Circular 100 mm diameter 150 mm below ground level with PCC 136 40 mm aggregate | Supply and Fix Metal cable route indicator of height 750 mm MS Flat of 40 mm x 4 mm with Circular 100 mm diameter MS Sheet of minimum thickness 3 mm duly engraved LT CABLE including Aluminium paint over it and to be fixed 150 mm below ground level with PCC 136 40 mm aggregate of size 250x250x300 mm all as directed by EngrinCharge |
| 39 | Dismantling existing LT panels of any type any size carefully for reuse including necessary excavation demolition of concrete disconnecting of earthing cable taking out burn out lugsMCCBs | Dismantling existing LT panels of any type any size carefully for reuse including necessary excavation demolition of concrete disconnecting of earthing cable taking out burn out lugsMCCBsbus barsinsulators and other connected works surface levelling etc and removing the old unserviceable rubbish burn out lugsMCCBsbus barsinsulators etc and refixing the LT panels after repairreplacement of burn out lugsMCCBsbus barsinsulators etc including reconnection of earthing cables with new foundation of panels with brick works PCC worksetc complete all as specified and as directed by Engrincharge.NOTE Earth Workbrick worksPCClugsMCCBbus barinsulators etc shall be Measured and Paid for separately under relevant items. |
| 40 | SF Framed work as in doors or gates of angle or other section with gusset plates rails braces | SF Framed work as in doors or gates of angle or other section with gusset plates rails braces etc. complete drilled for fixing of steel sheeting or other covering Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings exclusive of steel sheeting or other covering running rails and guides and hanging also fastening and fixing complete. |
| 41 | M L for cross arms bracing supports clamps and back plates fabricated from structural steel sections including nuts bolts washers | M L for cross arms bracing supports clamps and back plates fabricated from structural steel sections including nuts bolts washers welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed. |
| 42 | ML PCC 136 type C2 using 40mm graded aggregate as in foundation for stay set Pole Panels etc including fair finish even and fir to exposed surfaces | ML PCC 136 type C2 using 40mm graded aggregate as in foundation for stay set Pole Panels etc including fair finish even and fir to exposed surfaces without using extra cement complete all as specified and as directed. |
| 43 | M L PCC 124 type B1 with using 20 mm graded stone aggregate as coping of polepanel including necessary form work as required complete all as directed | M L PCC 124 type B1 with using 20 mm graded stone aggregate as coping of polepanel including necessary form work as required complete all as directed |
| 44 | M L for brick in CM 14 rendering using sub class B bricks straight or curved on plan exceeding 6 Mtr mean radius including dismantling old structure all as specified and directed. | M L for brick in CM 14 rendering using sub class B bricks straight or curved on plan exceeding 6 Mtr mean radius including dismantling old structure all as specified and directed. |
| 45 | M L for 15mm thick in cm 14 rendering on fair face of brick work finished even fair complete all as specified directed. | M L for 15mm thick in cm 14 rendering on fair face of brick work finished even fair complete all as specified directed. |
| 46 | M L for Hardcore of gauge n exc. 63 mm deposited spread and levelled in layers n exc. 15 cm thick watered and rammed to a true surface as specified and directed. | M L for Hardcore of gauge n exc. 63 mm deposited spread and levelled in layers n exc. 15 cm thick watered and rammed to a true surface as specified and directed. |
| 47 | SF Al Busbar rating as required Amps including making Holes for connections and colour coding as per existing busbar including taking down | SF Al Busbar rating as required Amps including making Holes for connections and colour coding as per existing busbar including taking down old unserviceable one complete all as specified and directed |
| 48 | SF in wiring Single core stranded copper conductor FRLS of size 16 sqmm including copper lugs at both ends complete all as specified and directed | SF in wiring Single core stranded copper conductor FRLS of size 16 sqmm including copper lugs at both ends complete all as specified and directed |
| 49 | SF in wiring Single core stranded copper conductor FRLS of size 10 sqmm including copper lugs at both ends complete all as specified and directed | SF in wiring Single core stranded copper conductor FRLS of size 10 sqmm including copper lugs at both ends complete all as specified and directed |
| 50 | Taking downdismantling of unserviceable LT panels complete all as specified and directed by EngineerinCharge | Taking downdismantling of unserviceable LT panels complete all as specified and directed by EngineerinCharge |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender