Bids Are invited for Supply Laying And Testing Cable Xlpe Insulatedbedded Galvanized Steel Strip Or Wire Heavy Duty With Stranded Aluminium 11100 Volts Grade Of Size 185 Sq Mm 3 Core - Supply Laying And Testing Cable Xlpe Insulated Screened Pvc Bedde
Tender Overview
Project Description
Bids Are invited for Supply Laying And Testing Cable Xlpe Insulatedbedded Galvanized Steel Strip Or Wire Heavy Duty With Stranded Aluminium 11100 Volts Grade Of Size 185 Sq Mm 3 Core - Supply Laying And Testing Cable Xlpe Insulated Screened Pvc Bedded Galvanized Steel Strip Or Wire Armoured Electric Power Cables Heavy Duty With Stranded Aluminium Conductor 11100 Volts Grade Of Size 185 Sq Mm 3 Core , Supply Laying And Testing Cable Xlpe Insulated Screened Pvc Bedded Galvanized Steel Strip 11100 Volts Grade Of Size 150 Sq Mm 3 Core - Supply Laying And Testing Cable Xlpe Insulated Screened Pvc Bedded Galvanized Steel Strip Or Wire Armoured Electric Power Cables Heavy Duty With Stranded Aluminium Conductor 11100 Volts Grade Of Size 150 Sq Mm 3 Core , Supply Laying And Testing Cable Xlpe Insulated Screened Pvc Steel Strip Or Wire Armoured Electric Heavy Duty With Stranded Conductor 11100 Volts Grade Of Size 120 Sq Mm 3 Core - Supply Laying And Testing Cable Xlpe Insulated Screened Pvc Bedded Galvanized Steel Strip Or Wire Armoured Electric Power Cables Heavy Duty With Stranded Aluminium Conductor 11100 Volts Grade Of Size 120 Sq Mm 3 Core , Excavation In Trenches Not Exceeding 1.5 M Width And Not Exc 1.5M In Depth Getting Out In Soft Loose Soil , Excavation In Trenches Not Exceeding 1.5 M Width And Exc 1.5M In Depth Getting Out In Soft Loose Soil , Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exceeding 25 Cm In Thick Using Excavated Soft Loose Soil , Removal Of Surplus Soil To A Distance Not Exceeding 50 M And Depositing , Supply And Lay Of Pcc Cable Cover Class Hv Type 1 Flat Size 300Mmx180mmx40mm , Supply And Lay For Dry Clean Of 8Cm Deep Before Laying And 15Cm Covering Above The Top Edge Of Cable After Laying And Punned Down To Required Height - Supply And Lay For Dry Clean Dirtless River Sand Filling For Cable Protection With A Layer Of 8Cm Deep Before Laying And 15Cm Covering Above The Top Edge Of Cable After Laying And Punned Down To Required Height , M And L For Double Wall Corrugated Dwc High Density Polyethylene Pipes Hdpe Of 90Mm Dia Laid In Trenches For Cable Protection , M And L For Fixing Gi Tubing 80Mm Dia Light Grade Use For The Protection Of Cable , M And L For Manual Boring Under Road Crossing And Laying Pipe Across The Road For Laying Cables Complete , S And F Pcc Cable Route Marker Of Size 900 300 70Mm Embossed With Ht Ug Cable 11Kv And 40Cm Depth Grouted In And Including Pcc 1 2 4 Type B2 Using 20Mm Graded Stone Aggregate - S And F Pcc Cable Route Marker Of Size 900X300x70mm Embossed With Ht Ug Cable 11Kv And Excavation Of 40Cm Depth Grouted In And Including Pcc 124 Type B2 Using 20Mm Graded Stone Aggregate , Material And Labour For Steel Tubular Poles Complete With Cast Iron Base Palate Final Taper Plug Bolts Naliminium Paint Over A Coat Of Red Oxide Zinc Chrome Primer - Material And Labour For Steel Tubular Poles Complete With Cast Iron Base Palate Final Taper Plug Bolts Nuts And Screws As Specified Type 410 Sp55 11 Meter Long Including Painting All External Exposed Steel Surfaces With Two Coats Of Aliminium Paint Over A Coat Of Red Oxide Zinc Chrome Primer , M And L For Switch Air Break Gang Operated Triple Pole Out Door Type Unit On Ht 11 Kv 50 Cycle Ac Suitable For Current Rating Upto 400 Amps - M And L For Switch Air Break Gang Operated Triple Pole Out Door Type Unit On Ht 11 Kv 50 Cycle Ac Suitable For Current Rating Upto 400 Amps Mechanically Operated Mounted On Porcelain Polymer Insulators 9 Insulators And Frame With Operating Mechanism , M And L For 11 Kv 200 Amps Outdoor Type Horn Gap Fuse Set Conforming To Is 9385 Parti Is Standards Gi Channel Angle Mounting Structure - M And L For 11 Kv 200 Amps Outdoor Type Horn Gap Fuse Set Conforming To Is 9385 Parti & Ii Relevant Latest Is Standards Complete With Galvanized Steel Horn Assembly Suitable Fuse Element Heavy Duty Porcelain Polymer Insulators Gi Channel Angle Mounting Structure Connectors Clamps Nuts , M And L For Cross Arms Bracing Supports Clamps And Back Plates Fabricated From Structuralcold Or Hot And Complete All As Specified And As Directed - M And L For Cross Arms Bracing Supports Clamps And Back Plates Fabricated From Structural Steel Sections Including Nuts Bolts Washers Welding Bending Cold Or Hot Drilling Holes For Bolts In Any Shape Or Size As Directed Inclusive Of 2 Coats Of Aluminium Paint Over A Coat Of Red Oxide Primer After Dismantling Old Unserviceable Cross Arms And Complete All As Specified And As Directed , M And L For Pin Type Porcelain Or Polymer Vitreous Brown Insulator Of Size 150Mm Height 150Mm Dia 11000 Volts Grade Including One And One Galvanized Iron Nut - M And L For Pin Type Porcelain Or Polymer Vitreous Brown Insulator Of Size 150Mm Height 150Mm Dia 11000 Volts Grade Including One Galvanized Mild Steel Spindle With Two Galvanized Iron Washers And One Galvanized Iron Nut , M And L For Disc Type Porcelain Polymer Insulator Vitreous 145 Mm Height And 255 Mm Diameter Ball And Socket Type Suitable For 11000 Volts Grade - M And L For Disc Type Porcelain Polymer Insulator Vitreous 145 Mm Height And 255 Mm Diameter Ball And Socket Type Suitable For 11000 Volts Grade Complete With One Galvanized Mild Steel Spindle Two Galvanized Iron Washers , M And L For Lightning Arrestersurge Protector 11 Kv Grade Heavy Duty Single Pole Self Supporting Station Expulsion Type Class 65 Ka Capacity - M And L For Lightning Arrestersurge Protector 11 Kv Grade Heavy Duty Single Pole Self Supporting Station Expulsion Type Class 65 Ka Capacity With All Fittings Complete All With Taking Down Old Unserviceable , S And F Danger Notice Plate Of 1.6Mm Thick Mild Steel Sheet Vitreous Enamelled White With Letters Figures And M.S. Clamps Bolts And Nuts Of Approved Size For Ht - S And F Danger Notice Plate Of 1.6Mm Thick Mild Steel Sheet Vitreous Enamelled White With Letters Figures And Conventional Skull And Bones In Signal Red Colour And Fixed With M.S. Clamps Bolts And Nuts Of Approved Size For Ht , M And L For Cement Concrete In Foundations Filling And Mass Concrete Type D2 1 4 8 Using 40Mm Grade Aggregate - M And L For Cement Concrete In Foundations Filling And Mass Concrete Type D2 148 Using 40Mm Grade Aggregate , M And L For Pcc 1 3 6 Type C2 Using 40Mm Grade Aggregate As In Foundation For Pole Etc Complete - M And L For Pcc 136 Type C2 Using 40Mm Grade Aggregate As In Foundation For Pole Etc Complete , M And L For Pcc 1 2 4 Type B1 Using 20Mm Grade Aggregate As In Coping For Pole Inclduing Form Work And Finishing The Surfaces Even And Smooth - M And L For Pcc 124 Type B1 Using 20Mm Grade Aggregate As In Coping For Pole Inclduing Form Work And Finishing The Surfaces Even And Smooth , M And L For Earthing Complete With Galvanised Steel Earth Plate Electrode 60 60Cm 6Mm Thick Buried Directly In Ground Earth Pit Not Less Than 2.25 Metres - M And L For Earthing Complete With Galvanised Steel Earth Plate Electrode 60 60Cm 6Mm Thick Buried Directly In Ground Earth Pit Not Less Than 2.25 Metres Deep Below Ground Level With Top Edge Of The Plate Not Less Than 1.5 Metres Below Normal Ground Level Connected To Galvanised Iron , M And L For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Etc As Required 32 6 Mm - M And L For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit Pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc As Required 32 6 Mm Galvanised Iron Strip Complete , Dismantling Concrete Poles Struts Any Size , Dismantling Cross Arms Of M S Channel Or Angle Sections Etc Complete And Setting Aside For Reuse With In 50M , Dismantling Insulators La Any Type Any Size
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Supply laying and testing cable XLPE insulatedbedded galvanized steel strip or wire heavy duty with stranded aluminium 11100 volts grade of size 185 sq mm 3 core | Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables heavy duty with stranded aluminium conductor 11100 volts grade of size 185 sq mm 3 core |
| 2 | Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip 11100 volts grade of size 150 sq mm 3 core | Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables heavy duty with stranded aluminium conductor 11100 volts grade of size 150 sq mm 3 core |
| 3 | Supply laying and testing cable XLPE insulated screened PVC steel strip or wire armoured electric heavy duty with stranded conductor 11100 volts grade of size 120 sq mm 3 core | Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables heavy duty with stranded aluminium conductor 11100 volts grade of size 120 sq mm 3 core |
| 4 | Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in soft loose soil | Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in soft loose soil |
| 5 | Excavation in trenches not exceeding 1.5 m width and exc 1.5m in depth getting out in soft loose soil | Excavation in trenches not exceeding 1.5 m width and exc 1.5m in depth getting out in soft loose soil |
| 6 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated soft loose soil | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated soft loose soil |
| 7 | Removal of surplus soil to a distance not exceeding 50 m and depositing | Removal of surplus soil to a distance not exceeding 50 m and depositing |
| 8 | Supply and lay of PCC cable cover class HV type 1 flat size 300mmx180mmx40mm | Supply and lay of PCC cable cover class HV type 1 flat size 300mmx180mmx40mm |
| 9 | Supply and lay for dry clean of 8cm deep before laying and 15cm covering above the top edge of cable after laying and punned down to required height | Supply and lay for dry clean dirtless river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying and punned down to required height |
| 10 | M and L for Double Wall Corrugated DWC High density polyethylene pipes HDPE of 90mm dia laid in trenches for cable protection | M and L for Double Wall Corrugated DWC High density polyethylene pipes HDPE of 90mm dia laid in trenches for cable protection |
| 11 | M and L for fixing GI tubing 80mm dia light grade use for the protection of cable | M and L for fixing GI tubing 80mm dia light grade use for the protection of cable |
| 12 | M and L for manual boring under road crossing and laying pipe across the road for laying cables complete | M and L for manual boring under road crossing and laying pipe across the road for laying cables complete |
| 13 | S and F PCC cable route marker of size 900 300 70mm embossed with HT UG cable 11kV and 40cm depth grouted in and including PCC 1 2 4 type B2 using 20mm graded stone aggregate | S and F PCC cable route marker of size 900x300x70mm embossed with HT UG cable 11kV and excavation of 40cm depth grouted in and including PCC 124 type B2 using 20mm graded stone aggregate |
| 14 | Material and labour for steel tubular poles complete with cast iron base palate final taper plug bolts naliminium paint over a coat of red oxide zinc chrome primer | Material and labour for steel tubular poles complete with cast iron base palate final taper plug bolts nuts and screws as specified type 410 SP55 11 meter long including painting all external exposed steel surfaces with two coats of aliminium paint over a coat of red oxide zinc chrome primer |
| 15 | M and L for switch air break gang operated triple pole out door type unit on HT 11 KV 50 cycle AC suitable for current rating upto 400 Amps | M and L for switch air break gang operated triple pole out door type unit on HT 11 KV 50 cycle AC suitable for current rating upto 400 Amps mechanically operated mounted on porcelain polymer insulators 9 insulators and frame with operating mechanism |
| 16 | M and L for 11 kV 200 Amps outdoor type Horn Gap Fuse set conforming to IS 9385 PartI IS standards GI channel angle mounting structure | M and L for 11 kV 200 Amps outdoor type Horn Gap Fuse set conforming to IS 9385 PartI & II relevant latest IS standards complete with galvanized steel horn assembly suitable fuse element heavy duty porcelain polymer insulators GI channel angle mounting structure connectors clamps nuts |
| 17 | M and L for cross arms bracing supports clamps and back plates fabricated from structuralcold or hot and complete all as specified and as directed | M and L for cross arms bracing supports clamps and back plates fabricated from structural steel sections including nuts bolts washers welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer after dismantling old unserviceable cross arms and complete all as specified and as directed |
| 18 | M and L for pin type porcelain or polymer vitreous brown insulator of size 150mm height 150mm dia 11000 volts grade including one and one galvanized iron nut | M and L for pin type porcelain or polymer vitreous brown insulator of size 150mm height 150mm dia 11000 volts grade including one galvanized mild steel spindle with two galvanized iron washers and one galvanized iron nut |
| 19 | M and L for disc type porcelain polymer insulator vitreous 145 mm height and 255 mm diameter ball and socket type suitable for 11000 volts grade | M and L for disc type porcelain polymer insulator vitreous 145 mm height and 255 mm diameter ball and socket type suitable for 11000 volts grade complete with one galvanized mild steel spindle two galvanized iron washers |
| 20 | M and L for lightning arrestersurge protector 11 KV grade heavy duty single pole self supporting station expulsion type class 65 KA capacity | M and L for lightning arrestersurge protector 11 KV grade heavy duty single pole self supporting station expulsion type class 65 KA capacity with all fittings complete all with taking down old unserviceable |
| 21 | S and F Danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white with letters figures and M.S. clamps bolts and nuts of approved size for HT | S and F Danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with M.S. clamps bolts and nuts of approved size for HT |
| 22 | M and L for Cement concrete in foundations filling and mass concrete type D2 1 4 8 using 40mm grade aggregate | M and L for Cement concrete in foundations filling and mass concrete type D2 148 using 40mm grade aggregate |
| 23 | M and L for PCC 1 3 6 type C2 using 40mm grade aggregate as in foundation for pole etc complete | M and L for PCC 136 type C2 using 40mm grade aggregate as in foundation for pole etc complete |
| 24 | M and L for PCC 1 2 4 type B1 using 20mm grade aggregate as in coping for pole inclduing form work and finishing the surfaces even and smooth | M and L for PCC 124 type B1 using 20mm grade aggregate as in coping for pole inclduing form work and finishing the surfaces even and smooth |
| 25 | M and L for Earthing complete with galvanised steel earth plate electrode 60 60cm 6mm thick buried directly in ground earth pit not less than 2.25 metres | M and L for Earthing complete with galvanised steel earth plate electrode 60 60cm 6mm thick buried directly in ground earth pit not less than 2.25 metres deep below ground level with top edge of the plate not less than 1.5 metres below normal ground level connected to galvanised iron |
| 26 | M and L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in etc as required 32 6 mm | M and L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32 6 mm galvanised iron strip complete |
| 27 | Dismantling concrete poles struts any size | Dismantling concrete poles struts any size |
| 28 | Dismantling cross arms of M S channel or angle sections etc complete and setting aside for reuse with in 50m | Dismantling cross arms of M S channel or angle sections etc complete and setting aside for reuse with in 50m |
| 29 | Dismantling insulators LA any type any size | Dismantling insulators LA any type any size |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender