Bids Are invited for S And F For Fibre Reinforced Plastic Smooth White Weather Resistant With Anti Uv 30 Feet Long Roman Pillar Min Dia 4 X 4 Ft Incl Insignia Of Indian Army And Corps Hq With Lighting - S And F For Fibre Reinforced Plastic Smooth Whi
Tender Overview
Project Description
Bids Are invited for S And F For Fibre Reinforced Plastic Smooth White Weather Resistant With Anti Uv 30 Feet Long Roman Pillar Min Dia 4 X 4 Ft Incl Insignia Of Indian Army And Corps Hq With Lighting - S And F For Fibre Reinforced Plastic Smooth White Weather Resistant With Anti Uv Coating Designer 30 Feet Long Roman Pillar With Min Dia 4 X 4 Ft Incl Drilled Top Sections Or Mounting Arms Insignia Of Indian Army And Corps Hq With Lighting , Supply Only Mettalic Body Air Circulator 600 Mm Sweep Pedastal 230 Volt Single Phase 1440 Rpm Minimum Air Delivery 125 Cmm 90 Degree Oscillotion - Supply Only Mettalic Body Air Circulator 600 Mm Sweep Pedastal 230 Volt Single Phase 1440 Rpm Minimum Air Delivery 125 Cmm 90 Degree Oscillotion Including Motor Protection Thermal Overlod Protection Device , Surface Dressing N.Exc Not Exceeding 15 Cm Deep And Getting Out Softloose Soil Complete All As Spd And Directed. , Excavation In Trenches Not Exc 1.5M Wide And Not Exc 1.5M Deep 10 Sqm On Plan And N.Exc 1.5M In Depth Soil Complete All As Specified And Directed. - Excavation In Trenches Not Exc 1.5M Wide And Not Exc 1.5M Deep For Foundation Etc Or For Shafts N.Exc 10 Sqm On Plan And N.Exc 1.5M In Depth And Getting Out In Softloose Soil Complete All As Specified And Directed. , Ml For Kankar Or Mix Of Fly Ash Clinke 1 3 6 I.E. 10 Fly Ash30 Clinker 60 Stone Dust Laying In Layers N.Exc 100Mm Complete All As Directed By Enggincharge . - Ml For Kankar Or Lateritewith Mix Of Fly Ash Clinker Stone Dust In The Proportion Of 136 I.E. 10% Fly Ash30% Clinker 60% Stone Dust Laying In Layers N.Exc 100Mm Thick Watering Ramming And Compacted Complete All As Directed By Engg-In-Charge . , Ml For Broken Stone Or Boulders Hard Core Gauge N.Exc 63Mm Deposited Spred And Levelled In Layers N.Exc 15Cm Thick Watered And Rammed To A True Surfaces Complete All As Specified And Directed , Ml For Pcc 1 8 Type D2 Using 40Mm Graded Stone Aggregates As In Bed Concrete For Foundation Filling Mass Concrete Complete All As Specified And Directed - Ml For Pcc 148 Type D-2 Using 40Mm Graded Stone Aggregates As In Bed Concrete For Foundation Filling Mass Concrete Complete All As Specified And Directed , M L For Reinforced Cement Concrete Design Mix M25 20Mm Graded Stone Aggregate Bases For Columns Etc. Concrete Etc Complete All As Directed. - M L For Reinforced Cement Concrete Design Mix M 25 20Mm Graded Stone Aggregate Foundations Including Rafts Footings Foundation Beams Plinth Beams Bases For Columns Etc. And Mass Concrete Etc Complete All As Directed. , M L For Reinforced Cement Concrete Design Mix M25 20Mm Graded Stone Aggregate In Columns Pillars Piers Etc Complete All As Specified And Directed , M L For Tmt Bars 10Mm Dia And Over Cut To Length Bent To Shape Required Including Cranking Bending Spirally For Complete All As Specified And Directed - M L For Tmt Bars 10Mm Dia And Over Cut To Length Bent To Shape Required Including Cranking Bending Spirally For Hooping For Columns Hooking Ends And Binding With The Including Mild Steel Wire Annealed Not Less Than 0.9Mm Dia Or Securing With Clips Complete All As Specified And Directed , Ditto But 5Mm Dia And Over Upto And Including 10Mm Dia In Stirrups Spacers And Binders Complete All As Specified And Directed , M L For Formwork To Sides Of Concrete Foundations Footings Bases Of Columns Raft And Raft Beams Sides Surfaces Of Concrete Complete All As Specified And Directed - M L For Formwork To Sides Of Concrete Foundations Footings Bases Of Columns Raft And Raft Beams Sides And Soffits If Any Of Foundation And Plinth Beams And Similar Work Vertical Or To Batter For Rough Finished Surfaces Of Concrete Complete All As Specified And Directed , M L For Formwork For Rough Finished Surface Of Concrete Flat Surface To Sides Of Surfaces Of Concrete Complete All As Specified And Directed - M L For Formwork For Rough Finished Surface Of Concrete Flat Surface To Sides Of Pillars Posts Struts Piers Columns And Stanchions For Fair Finished Surfaces Of Concrete Complete All As Specified And Directed , Ml For Old Size Brickwork With Fly Ash Bricks Straight Or Curved On Plan To Any Radius Built In Cm 1 6 Complete All As Specified And Directed - Ml For Old Size Brickwork With Fly Ash Bricks Straight Or Curved On Plan To Any Radius Built In Cm 16 Complete All As Specified And Directed , Removing Surplus Soil To A Distance Not Exceeding 50 Mtr And Depositing Where Directed At A Level Not Exceeding 1.5 Mtr Above The Starting Point Complete All As Specified And Directed , Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exc 25 Cm In Softloose Complete All As Specified And Directed , Sf For Frp Fiber Plastic Display Panel Boards Size 14 7Minimum 30Mm50mm Weather Resistant With Antiuve Complete All As Spd And Directed. - Sf For Frp Fiber Reinforced Plastic Size 14 7 Minimum 30Mm 50Mm Thickness With Smooth White Weather Resistant With Anti Uv Complete All As Spd And Directed. , Sf For Frp Fiber Reinforced Plastic Designer 10 Ft Roman Pillar With Minimum Dia 4060Cm Thick - Sf For Frp Fiber Reinforced Plastic Designer 10 Ft Roman Pillar With Minimum Dia 40-60Cm Thick Includes Drilled Top Sections Or Mounting Arms And Hot-Dip Galvanized Ms Mild Steel Or Frp-Coated Base Plates Secured With Heavy-Duty Anchor Bolts With Smooth White Weather Resistant With Anti-Uv Coating Complete All As Spd And Directed. Noted It Should Be 100% Water Prooffing Anti Aging And Rust- Proof.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | S and F for fibre reinforced plastic smooth white weather resistant with anti UV 30 feet long Roman pillar min dia 4 x 4 ft incl insignia of Indian Army and Corps HQ with lighting | S and F for fibre reinforced plastic smooth white weather resistant with anti UV coating designer 30 feet long Roman pillar with min dia 4 x 4 ft incl drilled top sections or mounting arms insignia of Indian Army and Corps HQ with lighting |
| 2 | Supply only mettalic body Air circulator 600 mm sweep pedastal 230 volt single phase 1440 RPM minimum air delivery 125 cmm 90 degree oscillotion | Supply only mettalic body Air circulator 600 mm sweep pedastal 230 volt single phase 1440 RPM minimum air delivery 125 cmm 90 degree oscillotion including motor protection thermal overlod protection device |
| 3 | Surface dressing n.exc Not exceeding 15 cm deep and getting out softloose soil complete all as spd and directed. | Surface dressing n.exc Not exceeding 15 cm deep and getting out softloose soil complete all as spd and directed. |
| 4 | Excavation in trenches not exc 1.5m wide and not exc 1.5m deep 10 Sqm on plan and n.exc 1.5m in depth soil complete all as specified and directed. | Excavation in trenches not exc 1.5m wide and not exc 1.5m deep for foundation etc or for shafts n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in softloose soil complete all as specified and directed. |
| 5 | ML for Kankar or mix of fly ash clinke 1 3 6 i.e. 10 fly ash30 clinker 60 stone dust laying in layers n.exc 100mm complete all as directed by Enggincharge . | ML for Kankar or lateritewith mix of fly ash clinker stone dust in the proportion of 136 i.e. 10% fly ash30% clinker 60% stone dust laying in layers n.exc 100mm thick watering ramming and compacted complete all as directed by Engg-in-charge . |
| 6 | ML for broken stone or boulders hard core gauge n.exc 63mm deposited spred and levelled in layers n.exc 15cm thick watered and rammed to a true surfaces complete all as specified and directed | ML for broken stone or boulders hard core gauge n.exc 63mm deposited spred and levelled in layers n.exc 15cm thick watered and rammed to a true surfaces complete all as specified and directed |
| 7 | ML for PCC 1 8 type D2 using 40mm graded stone aggregates as in bed concrete for foundation filling mass concrete complete all as specified and directed | ML for PCC 148 type D-2 using 40mm graded stone aggregates as in bed concrete for foundation filling mass concrete complete all as specified and directed |
| 8 | M L for reinforced cement concrete Design Mix M25 20mm graded stone aggregate bases for columns etc. concrete etc complete all as directed. | M L for reinforced cement concrete Design Mix M 25 20mm graded stone aggregate foundations including rafts footings foundation beams plinth beams bases for columns etc. and mass concrete etc complete all as directed. |
| 9 | M L for reinforced cement concrete Design Mix M25 20mm graded stone aggregate in columns pillars piers etc complete all as specified and directed | M L for reinforced cement concrete Design Mix M25 20mm graded stone aggregate in columns pillars piers etc complete all as specified and directed |
| 10 | M L for TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for complete all as specified and directed | M L for TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with the including mild steel wire annealed not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 11 | Ditto but 5mm dia and over upto and including 10mm dia in stirrups spacers and binders complete all as specified and directed | Ditto but 5mm dia and over upto and including 10mm dia in stirrups spacers and binders complete all as specified and directed |
| 12 | M L for formwork to sides of concrete foundations footings bases of columns raft and raft beams sides surfaces of concrete complete all as specified and directed | M L for formwork to sides of concrete foundations footings bases of columns raft and raft beams sides and soffits if any of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete complete all as specified and directed |
| 13 | M L for formwork for rough finished surface of concrete flat surface to sides of surfaces of concrete complete all as specified and directed | M L for formwork for rough finished surface of concrete flat surface to sides of pillars posts struts piers columns and stanchions for fair finished surfaces of concrete complete all as specified and directed |
| 14 | ML for old size brickwork with fly ash bricks straight or curved on plan to any radius built in CM 1 6 complete all as specified and directed | ML for old size brickwork with fly ash bricks straight or curved on plan to any radius built in CM 16 complete all as specified and directed |
| 15 | Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed | Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed |
| 16 | Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm in softloose complete all as specified and directed | Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm in softloose complete all as specified and directed |
| 17 | SF for FRP Fiber Plastic display panel boards Size 14 7minimum 30mm50mm weather resistant with antiUVe complete all as spd and directed. | SF for FRP Fiber Reinforced Plastic Size 14 7 minimum 30mm 50mm thickness with smooth white weather resistant with anti UV complete all as spd and directed. |
| 18 | SF for FRP Fiber Reinforced Plastic designer 10 ft Roman pillar with minimum dia 4060cm thick | SF for FRP Fiber Reinforced Plastic designer 10 ft Roman pillar with minimum dia 40-60cm thick Includes drilled top sections or mounting arms and hot-dip galvanized MS Mild Steel or FRP-coated base plates secured with heavy-duty anchor bolts with smooth white weather resistant with anti-UV coating complete all as spd and directed. Noted It should be 100% water prooffing anti aging and rust- proof. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender