Bids Are invited for Ml For Cable In Trenches Or Xlpe Electric Lt Cable With Stranded Aluminium For 1100 Volts Grade Cross Sectional Area 16 Sqmm 4Core - Ml For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Galvanised Steel Stri
Tender Overview
Project Description
Bids Are invited for Ml For Cable In Trenches Or Xlpe Electric Lt Cable With Stranded Aluminium For 1100 Volts Grade Cross Sectional Area 16 Sqmm 4Core - Ml For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 16 Sqmm 4 Core Including Cable Gland And Lugs Including Taking Down Old Unserviceable Cable Complete All As Specified And Directed. , Ml For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 25 Sqmm 3.5 Core - Ml For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 25 Sqmm 3.5 Core Including Cable Gland And Lugs Including Taking Down Old Unserviceable Cable Complete All As Specified And Directed. , Ml For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty 1100 Volts Grade Cross Sectional Area 35 Sqmm 3.5 Core - Ml For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 35 Sqmm 3.5 Core Including Cable Gland And Lugs Including Taking Down Old Unserviceable Cable Complete All As Specified And Directed. , Ml For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty 1100 Volts Grade Cross Sectional Area 95 Sqmm 3.5 Core - Ml For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 95 Sqmm 3.5 Core Including Cable Gland And Lugs Including Taking Down Old Unserviceable Cable Complete All As Specified And Directed. , Excavating In Trenches Not Exc. 1.50 Mtr Wide And Not Exc. 1.50 Mtr In Depth Getting Out In Soft Loose Soil Complete All As Specified And As Directed. - Excavating In Trenches Not Exc. 1.50 Mtr Wide And Not Exc. 1.50 Mtr In Depth Getting Out In Soft Loose Soil Complete All As Specified And As Directed. , Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exc. 250Mm In Soft Loose Soil Complete All As Specified And As Directed - Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exc. 250Mm In Softloose Soil Complete All As Specified And As Directed. , Removing Excavated Materials Soil Not Exc. 50.00 Mtr And Depositing Where Directed At A Level Not Exc. 1.50 Mtr As Specified As Directed - Removing Excavated Materials Not Exc. 50.00 Mtr And Depositing Where Directed At A Level Not Exc. 1.50 Mtr Above The Starting Point In Soil Complete All As Specified And As Directed. , Ml Sand Cushioning In Trenches For Of Ug Cables And In Of 230Mm Spread Thickness And Punned Upto 180Mm Thicknesscomplete All As Specified And As Directed - M L Sand Cushioning In Trenches For Protection Of Ug Cables Below Above And Around The Ug Cable Laid In Trenches Of 230Mm Spread Thickness And Consolidated Upto 180Mm Thickness Complete All As Specified And As Directed. Note For The Purpose Of Paymentpunned Thickness Of Sand Cushioning Only Shall Be Measured And Paid , Ml For Fly Ash Bricks Locally Available Laid Dry Width Wise Across The Line Of Cable In Trenches For Protection Of Ug Cable As Specified As Directed - Ml For Fly Ash Bricks Locally Available Laid Dry Width Wise Across The Line Of Cable In Trenches For Protection Of Ug Cable Complete All As Specified And As Directed. , Sf Galvanised Iron Pipe 80Mm Bore Dia Light Grade For Protection Of Ug Cable As Pecified As Directed - Sf Galvanised Iron Pipe 80Mm Bore Dia Light Grade For Protection Of Ug Cable Laid In Floors Road Crossing Fixing To Pole With Mild Steel Clamps Nuts Bolts Etc. Complete All As Specified And As Directed. , Sf Galvanised Iron Pipe 50Mm Bore Dia Light Grade For Protection Of Ug Cable Inmild Steel Clamps Nuts Bolts As Specified As Directed - Sf Galvanised Iron Pipe 50Mm Bore Dia Light Grade For Protection Of Ug Cable Laid In Floors Road Crossing Fixing To Pole With Mild Steel Clamps Nuts Bolts Etc. Complete All As Specified And As Directed. , S F Hdpe Dwc Double Walled Corrugated Of Diameter 40 Mm As Specified As Directed - S F Hdpe Dwc Double Walled Corrugated Of Diameter 40 Mm With Coupler Including Disconnection And Connection Of Cable Near Paneloh For Pipe Fixing Including Joints Complete All As Directed. , S F Hdpe Dwc Double Walled Corrugated Of Diameter 63 Mm With Including Disconnection As Specified As Directed - S F Hdpe Dwc Double Walled Corrugated Of Diameter 63 Mm With Including Disconnection And Connection Of Cable Near Paneloh For Pipe Fixing Including Joints Complete All As Directed. , Ml For Horizontal Boring For Passing Protection Pipe Up To 80Mm Bore Under Road Foot Path Not Exc. 10.00 Mtr In A Single Length As Specified As Directed - Ml For Horizontal Boring For Passing Protection Pipe Up To 80Mm Bore Dia Under Road Foot Path Not Exc. 10.00 Mtr In A Single Length Complete All As Specified And As Directed. Note Pipe To Be Measured Separately. , Ml For Earthing Ms Galvanized Plate Of Size 60Cmx60cmx6mm Buried Directly In Ground Earth Pit Not Less Than 2.25 Mtrs Deep Below Ground Level - Ml For Earthing Complete With Ms Galvanized Plate Of Size 60Cmx60cmx6mm As Earth Electrode Buried Directly In Ground Earth Pit Not Less Than 2.25 Mtrs Deep Below Ground Level With Top Edge Of The Plate Not Less Than 1.5 Mtrs Below Normal Ground Level Connected To Galvanised Iron Strip 25X4mm As Earthing Lead By Means Of Bolts Nuts Check Nuts And Washers Of Galvanised Ironwelding Or Steel All Work Pcc Pit With 50Mm Thick Rcc Coverci Ms Cover Having Suitable Handle 10Mm Ms Rod 20Mm Dia Gi Medium Gi Funnel With Wire Mesh 40Mm Bore Gi Pipe Medium Grade Isi Marked For Protection Of Earth Lead Conductor And Testing On Completion Complete All As Specified And As Directed By Engineerincharge.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | ML for cable in trenches or XLPE electric LT cable with stranded aluminium for 1100 volts grade cross sectional area 16 sqmm 4core | ML for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 16 sqmm 4 core including cable gland and lugs including taking down old unserviceable cable complete all as specified and directed. |
| 2 | ML for cable in trenches or passing through pipe XLPE insulated heavy duty aluminium conductor for 1100 volts grade cross sectional area 25 sqmm 3.5 core | ML for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 25 sqmm 3.5 core including cable gland and lugs including taking down old unserviceable cable complete all as specified and directed. |
| 3 | ML for cable in trenches or passing through pipe XLPE insulated heavy duty 1100 volts grade cross sectional area 35 sqmm 3.5 core | ML for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 35 sqmm 3.5 core including cable gland and lugs including taking down old unserviceable cable complete all as specified and directed. |
| 4 | ML for cable in trenches or passing through pipe XLPE insulated heavy duty 1100 volts grade cross sectional area 95 sqmm 3.5 core | ML for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 95 sqmm 3.5 core including cable gland and lugs including taking down old unserviceable cable complete all as specified and directed. |
| 5 | Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth getting out in Soft Loose Soil complete all as specified and as directed. | Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth getting out in Soft Loose Soil complete all as specified and as directed. |
| 6 | Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in Soft Loose Soil complete all as specified and as directed | Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in SoftLoose Soil complete all as specified and as directed. |
| 7 | Removing excavated Materials Soil not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr as specified as directed | Removing excavated Materials not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil complete all as specified and as directed. |
| 8 | ML Sand Cushioning in Trenches for of UG Cables and in of 230mm Spread thickness and punned upto 180mm thicknesscomplete all as specified and as directed | M L Sand Cushioning in Trenches for protection of UG Cables below above and around the UG Cable laid in Trenches of 230mm Spread thickness and consolidated upto 180mm thickness complete all as specified and as directed. Note For the purpose of PaymentPunned thickness of Sand Cushioning only shall be Measured and Paid |
| 9 | ML for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable as specified as directed | ML for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed. |
| 10 | SF Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable as pecified as directed | SF Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts etc. complete all as specified and as directed. |
| 11 | SF Galvanised Iron Pipe 50mm Bore dia Light Grade for protection of UG Cable inMild Steel Clamps Nuts Bolts as specified as directed | SF Galvanised Iron Pipe 50mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts etc. complete all as specified and as directed. |
| 12 | S F HDPE DWC Double Walled Corrugated of Diameter 40 mm as specified as directed | S F HDPE DWC Double Walled Corrugated of Diameter 40 mm with coupler including disconnection and connection of cable near panelOH for pipe fixing including joints complete all as directed. |
| 13 | S F HDPE DWC Double Walled Corrugated of Diameter 63 mm with including disconnection as specified as directed | S F HDPE DWC Double Walled Corrugated of Diameter 63 mm with including disconnection and connection of cable near panelOH for pipe fixing including joints complete all as directed. |
| 14 | ML for Horizontal Boring for Passing Protection Pipe up to 80mm Bore under Road Foot Path not exc. 10.00 mtr in a Single Length as specified as directed | ML for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road Foot Path not exc. 10.00 mtr in a Single Length complete all as specified and as directed. Note Pipe to be measured separately. |
| 15 | ML for earthing MS galvanized plate of size 60cmx60cmx6mm buried directly in ground earth pit not less than 2.25 mtrs deep below ground level | ML for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs deep below ground level with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised iron strip 25x4mm as earthing lead by means of bolts nuts check nuts and washers of galvanised ironwelding or steel all work PCC pit with 50mm thick RCC coverCI MS cover having suitable handle 10mm MS Rod 20mm dia GI medium GI funnel with wire mesh 40mm bore GI pipe medium grade ISI marked for protection of earth lead conductor and testing on completion complete all as specified and as directed by EngineerinCharge. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender