Tender For Provn Of 1X Underground Living Bunker At 9 Jat At Uri Under Ge 969 Ews.
Tender Value
24.30 Lakhs
Estimated cost
Bid Submission
08 Dec 2026
16 days left
EMD
48600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baramulla → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Provn Of 1X Underground Living Bunker At 9 Jat At Uri Under Ge 969 Ews.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches n.exc 1.5m wide and 1.5m depth for foundation etc or for shaft well, cesspits etc n.exc on plan and n.exc 1.5m depth and getting out in hard/dense soil, complete all as specified and as directed. |
| 2 | M&L for PCC 1:3:6, Type C-2 (40mm graded crushed stone aggregate) as in foundations, filling and mass concrete etc, complete all as specified and as directed. |
| 3 | M & L for walling of random rubble uncoursed well bonded solidly hearted built in CM 1:4 etc, complete all as specified and as directed. |
| 4 | M&L for providing cement concrete 1:2:4, Type B-1 (20mm graded crushed stone aggregate) as in coping etc, complete all as specified and as directed. |
| 5 | M&L for rendering 15mm thick in cement mortar 1:4 on on stone masonary surfaces or surface other than fair face of brick-work or on one side of lathing including finishing to surfaces even and smooth without using extra cement etc, complete all as specified and as directed. |
| 6 | M&L for extra stone walling for hammer dressing in faces stones of random rubble walling uncoursed fro granite or trap stone etc, complete all as specified and as directed. |
| 7 | M&L for cement concrete type C2, 1:3:6 (40mm graded crushed stone aggregate) as in surface channel and drains, complete all as specified and as directed. |
| 8 | Returning filling in incl spreading leveling, watering and well ramming in layers n exc 25 cm, complete all as specified and as directed. |
| 9 | Removing of excavated soil not exc 50m and depositing where directed at a level not exc 1.5 M above the starting point, complete all as specified and as directed. |
| 10 | Extra for forming fair finished drain channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and as directed. |
| 11 | M&L for providing precast cement concrete type B-1, 1:2:4 (20mm graded crushed stone aggregate) and set in cement mortar 1:6 in landings, cover slabs (for manholes/ drain cover), complete all as specified and as directed. |
| 12 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and as directed. |
| 13 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed, complete all as specified and as directed. |
| 14 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) in all kinds of soil including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified and as directed. |
| 15 | All as per Ser No 14 above but 1.5 m to 3 m deep., complete all as specified and as directed. |
| 16 | All as per Ser No 14 above but over 3 m deep, complete all as specified and as directed. |
| 17 | M&L for Cement concrete Type C-2 1:3:6 (Using 40 mm graded aggregate) in foundations, filling and mass concrete, complete all as specified and as directed. |
| 18 | M&L for RCC Design Mix M-30 as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed. |
| 19 | M&L for RCC Design Mix M-30 as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses, complete all as specified and as directed. |
| 20 | M&L for RCC Design Mix M-30 as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed. |
| 21 | M&L for RCC Design Mix M-30 as in Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed. |
| 22 | M&L for RCC Design Mix M-30 as in Columns, pillars, piers, posts and struts, complete all as specified and as directed. |
| 23 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and as directed. |
| 24 | Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter, complete all as specified and as directed. |
| 25 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; exceeding 200mm thick (Horizontal or sloping), complete all as specified and as directed. |
| 26 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified and as directed. |
| 27 | S&F for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed. |
| 28 | S&F for Mild steel TMT bars 5 to 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed. |
| 29 | M&L for Roof treatment to concrete surfaces by using minimum 1.52mm thick EPDM (Ethylene Propylene Diene Monomer) sheet by applying bonding adhesive to the substrate using a roller at 0.25-0.30mm thickness suitable as per manufacturer instruction, complete all as specified and as directed. |
| 30 | Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5m high from base, complete all as specified and as directed. |
| 31 | M&L for 40 mm thick Cement concrete type B-1, 1:2:4 (20mm graded crushed stone aggregate), complete all as specified and as directed. |
| 32 | M&L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, complete all as specified and as directed. |
| 33 | M&L for rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces in ceiling, complete all as specified and as directed. |
| 34 | M&L for 03 coats of whitewash on newly plastered surfaces of wall incl preparation, complete all as specified and as directed. |
| 35 | M&L for 03 coats of whitewash on newly plastered surfaces of ceiling incl preparation, complete all as specified and as directed. |
| 36 | Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed, complete all as specified and as directed. |
| 37 | S&F Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors or fixed to walls, complete all as specified and as directed. |
| 38 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed. |
| 39 | S&F for Plates (plain or chequered) channels or MS Sheets, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, complete all as specified and as directed. |
| 40 | M&L for 100 mm thick cement concrete type C-2, 1:3:6 as in plinth protection, complete all as specified and as directed. |
| 41 | M & L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed. |
| 42 | M&L for 75mm thick cement concrete type C-2, 1:3:6 (40mm graded crushe stone aggregate) as in sub base of floors, finished even and fair over well/rammed/compacted earth, complete all as specified and as directed. |
| 43 | M & L cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and as directed. |
| 44 | M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory ompaction by using plate vibrator, filling he joints with fine sand and cutting of paver block as per required size and attern, finishing and sweeping extra sand, complete all as specified and as directed. |
| 45 | Excavation in post holes (or similar holes) in hard/dense soil each n.exc 0.5cum getting out, returing, filling in and raming earth/broken rubble mixed with earth around, in layers n.exc 25cm, watering and removing surplus soil to a distance n.exc 50m and making good surface in soft/loose soil, complete all as specified and as directed. |
| 46 | M&L Plain Cement concrete Type B-2, 1:2:4 (40mm graded aggregate), in foundation, filling and mass concrete, complete all as specified and as directed. |
| 47 | M & L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as etc, complete all as specified and as directed. |
| 48 | Framed brackets of angles or tees, rafter purlins with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165, complete all as specified and as directed. |
| 49 | S&F mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat ections) including distance pieces, cleats etc complete all as specified. Fe 410 Gde -250, complete all as specified and as directed. |
| 50 | M&L for preperaring surfaces of newly or previously untreated steel or iron surfaces of any description over 10 cm in width or girth not otherwise described and apply two coats of sythetic enamel paint over a coat of red oxide primer, complete all as specified and as directed. |
| 51 | M&L for Point wiring using proper colour coding complete with 1100 Volts grade 1.5 Sq.mm, single core, PVC insulated, unsheathed cable with multistranded copper conductor with ISI mark FRLS grade, conforming to IS-694 in and including PVCmedium grade conduit not less than 25mm dia. ISI marked with all accessories concealed in wall/ceiling/ floor /roof etc,with sunk pressed steel/GI terminals boxes having 1.6 mm thick suitable for housing of modular type switches/sockets/fan regulators, including 1.5 Sq.mm PVC insulated, unsheathed, multistranded copper conductor, FRLS 1100 volts grade (green colour) as earth wire, connected to common earth dolly for :- |
| 52 | (a) One light point/fan point/Ex fan point controlled by one 5 Amps switch one way |
| 53 | (b) One 3 pin 5 Amp switch socket outlet on independent board |
| 54 | (c) One 3 pin 5 Amp switch socket outlet on same board with accessories |
| 55 | M&L for Point wiring using proper colour coding complete with 1100 Volts grade 2.5 Sq.mm, single core, PVC insulated, unsheathed cable with multistranded copper conductor with ISI mark FRLS grade, conforming to IS-694 in and including PVC medium grade conduit not less than 25mm dia. ISI marked with all accessories concealed in wall/ceiling/ floor /roof etc,with sunk pressed steel/GI terminals boxes having 1.6 mm thick suitable for housing of modular type switches/sockets/fan regulators, including 2.5 Sq.mm PVC insulated, unsheathed, multistranded copper conductor, FRLS 1100 volts grade (green colour) as earth wire, connected to common earth dolly for switch socket combination, 3 pin, 15 Amps on independent board, complete all as specified and as directed. |
| 56 | S&F switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and as directed |
| 57 | S&F switch piano Flush type, single pole, 15 amp 240 volts, complete all as specified and as directed. |
| 58 | S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type, complete all as specified and as directed. |
| 59 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type, complete all as specified and as directed. |
| 60 | Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body, complete all as specified and as directed. |
| 61 | S&F in repairs Distribution Board, SPN 8 Way, Double door complete all as specified and as directed |
| 62 | S & F in repairs MCB,DP 40 Amps 240 Volts B curve, complete all as specified and as directed |
| 63 | S & F MCB Single pole 6-32A Amps 240 Volts B Curve, complete all as specified and as directed. |
| 64 | Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed. |
| 65 | S&F XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volt grade, cross sectional area of size 10 Sqmm, 2 core, complete all as specified and as directed. |
| 66 | S&F building security light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with- 25 Nos IP 65/66 protection, complete all as specified and directed. |
| 67 | Provisional Sum: - Provide a provisional sum of Rs 1,00,000.00 for misc items like half brick work (outer protective wall, dump proof treatment, rendering 15mm thick wall EPDM and upward fascia) flat brick etc as per developed drgs complete all as specified and as directed.Note: - The work under provisional sum shall be priced at SSR 2020 ( Part-II) rates adjusted by contractor's percentage derived from Quoted amount against this item. The work under Provisional sum shall be carried out to any extend as ordered by GE Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysDec 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender